Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38631000

RESUMO

BACKGROUND: Particle mini-beam therapy exhibits promise in sparing healthy tissue through spatial fractionation, particularly notable for heavy ions, further enhancing the already favorable differential biological effectiveness at both target and entrance regions. However, breathing-induced organ motion affects particle mini-beam irradiation schemes since the organ displacements exceed the mini-beam structure dimensions, decreasing the advantages of spatial fractionation. PURPOSE: In this study, the impact of breathing-induced organ motion on the dose distribution was examined at the target and organs at risk(OARs) during carbon ion mini-beam irradiation for pancreatic cancer. METHODS: As a first step, the carbon ion mini-beam pattern was characterized with Monte Carlo simulations. To analyze the impact of breathing-induced organ motion on the dose distribution of a virtual pancreas tumor as target and related OARs, the anthropomorphic Pancreas Phantom for Ion beam Therapy (PPIeT) was irradiated with carbon ions. A mini-beam collimator was used to deliver a spatially fractionated dose distribution. During irradiation, varying breathing motion amplitudes were induced, ranging from 5 to 15 mm. Post-irradiation, the 2D dose pattern was analyzed, focusing on the full width at half maximum (FWHM), center-to-center distance (ctc), and the peak-to-valley dose ratio (PVDR). RESULTS: The mini-beam pattern was visible within OARs, while in the virtual pancreas tumor a more homogeneous dose distribution was achieved. Applied motion affected the mini-beam pattern within the kidney, one of the OARs, reducing the PVDR from 3.78  ± $\pm$  0.12 to 1.478  ± $\pm$  0.070 for the 15 mm motion amplitude. In the immobile OARs including the spine and the skin at the back, the PVDR did not change within 3.4% comparing reference and motion conditions. CONCLUSIONS: This study provides an initial understanding of how breathing-induced organ motion affects spatial fractionation during carbon ion irradiation, using an anthropomorphic phantom. A decrease in the PVDR was observed in the right kidney when breathing-induced motion was applied, potentially increasing the risk of damage to OARs. Therefore, further studies are needed to explore the clinical viability of mini-beam radiotherapy with carbon ions when irradiating abdominal regions.

2.
Phys Med Biol ; 69(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-37995363

RESUMO

Objective.To study the secondary neutrons generated by primary oxygen beams for cancer treatment and compare the results to those from primary protons, helium, and carbon ions. This information can provide useful insight into the positioning of neutron detectors in phantom for future experimental dose assessments.Approach.Mono-energetic oxygen beams and spread-out Bragg peaks were simulated using the Monte Carlo particle transport codesFLUktuierende KAskade, tool for particle simulation, and Monte Carlo N-Particle, with energies within the therapeutic range. The energy and angular distribution of the secondary neutrons were quantified.Main results.The secondary neutron spectra generated by primary oxygen beams present the same qualitative trend as for other primary ions. The energy distributions resemble continuous spectra with one peak in the thermal/epithermal region, and one other peak in the fast/relativistic region, with the most probable energy ranging from 94 up to 277 MeV and maximum energies exceeding 500 MeV. The angular distribution of the secondary neutrons is mainly downstream-directed for the fast/relativistic energies, whereas the thermal/epithermal neutrons present a more isotropic propagation. When comparing the four different primary ions, there is a significant increase in the most probable energy as well as the number of secondary neutrons per primary particle when increasing the mass of the primaries.Significance.Most previous studies have only presented results of secondary neutrons generated by primary proton beams. In this work, secondary neutrons generated by primary oxygen beams are presented, and the obtained energy and angular spectra are added as supplementary material. Furthermore, a comparison of the secondary neutron generation by the different primary ions is given, which can be used as the starting point for future studies on treatment plan comparison and secondary neutron dose optimisation. The distal penumbra after the maximum dose deposition appears to be a suitable location for in-phantom dose assessments.


Assuntos
Nêutrons , Terapia com Prótons , Terapia com Prótons/métodos , Prótons , Dosagem Radioterapêutica , Método de Monte Carlo
3.
Phys Med Biol ; 68(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-37918022

RESUMO

Objective. Carbon ion radiotherapy is a promising radiation technique for malignancies like pancreatic cancer. However, organs' motion imposes challenges for achieving homogeneous dose delivery. In this study, an anthropomorphicPancreasPhantom forIon-beamTherapy (PPIeT) was developed to simulate breathing and gastrointestinal motion during radiotherapy.Approach. The developed phantom contains a pancreas, two kidneys, a duodenum, a spine and a spinal cord. The shell of the organs was 3D printed and filled with agarose-based mixtures. Hounsfield Units (HU) of PPIeTs' organs were measured by CT. The pancreas motion amplitude in cranial-caudal (CC) direction was evaluated from patients' 4D CT data. Motions within the obtained range were simulated and analyzed in PPIeT using MRI. Additionally, GI motion was mimicked by changing the volume of the duodenum and quantified by MRI. A patient-like treatment plan was calculated for carbon ions, and the phantom was irradiated in a static and moving condition. Dose measurements in the organs were performed using an ionization chamber and dosimetric films.Main results. PPIeT presented tissue equivalent HU and reproducible breathing-induced CC displacements of the pancreas between (3.98 ± 0.36) mm and a maximum of (18.19 ± 0.44) mm. The observed maximum change in distance of (14.28 ± 0.12) mm between pancreas and duodenum was consistent with findings in patients. Carbon ion irradiation revealed homogenous coverage of the virtual tumor at the pancreas in static condition with a 1% deviation from the treatment plan. Instead, the dose delivery during motion with the maximum amplitude yielded an underdosage of 21% at the target and an increased uncertainty by two orders of magnitude.Significance. A dedicated phantom was designed and developed for breathing motion assessment of dose deposition during carbon ion radiotherapy. PPIeT is a unique tool for dose verification in the pancreas and its organs at risk during end-to-end tests.


Assuntos
Radioterapia com Íons Pesados , Neoplasias Pancreáticas , Humanos , Movimentos dos Órgãos , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento (Física) , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Carbono , Imagens de Fantasmas , Dosagem Radioterapêutica
4.
Radiat Prot Dosimetry ; 199(15-16): 1790-1792, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37819303

RESUMO

The Paul Scherrer Institute (PSI) is the largest research institute for natural and engineering sciences in Switzerland. PSI develops, builds and operates complex large research facilities. Every year, >2400 scientists from Switzerland and around the world come to PSI to use the facilities and to carry out experiments. Many areas at PSI are radiation protection areas. Depending on the radiation protection area, the work carried out and the time the users spend in these areas, they have to carry a personal dosemeter. PSI runs an individual monitoring service in compliance with the Swiss legislation on radiological protection and approved by the Swiss Federal Nuclear Safety Inspectorate. The service provides about 35 000 dosemeters per year for the internal and external customers consisting of whole-body dosemeters for photons and neutrons as well as extremity dosemeters. This paper gives an overview on the employed personal dosimetry techniques by the individual monitoring service of PSI, the number of distributed dosemeters for internal and external customers and statistics about the measured doses at PSI over 30 years.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação , Monitoramento de Radiação/métodos , Doses de Radiação , Exposição Ocupacional/análise , Radiometria , Dosímetros de Radiação , Nêutrons , Sensibilidade e Especificidade
5.
Front Oncol ; 13: 1333039, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38510267

RESUMO

Purpose: To demonstrate the suitability of optically stimulated luminescence detectors (OSLDs) for accurate simultaneous measurement of the absolute point dose and dose-weighted linear energy transfer (LETD) in an anthropomorphic phantom for experimental validation of daily adaptive proton therapy. Methods: A clinically realistic intensity-modulated proton therapy (IMPT) treatment plan was created based on a CT of an anthropomorphic head-and-neck phantom made of tissue-equivalent material. The IMPT plan was optimized with three fields to deliver a uniform dose to the target volume covering the OSLDs. Different scenarios representing inter-fractional anatomical changes were created by modifying the phantom. An online adaptive proton therapy workflow was used to recover the daily dose distribution and account for the applied geometry changes. To validate the adaptive workflow, measurements were performed by irradiating Al2O3:C OSLDs inside the phantom. In addition to the measurements, retrospective Monte Carlo simulations were performed to compare the absolute dose and dose-averaged LET (LETD) delivered to the OSLDs. Results: The online adaptive proton therapy workflow was shown to recover significant degradation in dose conformity resulting from large anatomical and positioning deviations from the reference plan. The Monte Carlo simulations were in close agreement with the OSLD measurements, with an average relative error of 1.4% for doses and 3.2% for LETD. The use of OSLDs for LET determination allowed for a correction for the ionization quenched response. Conclusion: The OSLDs appear to be an excellent detector for simultaneously assessing dose and LET distributions in proton irradiation of an anthropomorphic phantom. The OSLDs can be cut to almost any size and shape, making them ideal for in-phantom measurements to probe the radiation quality and dose in a predefined region of interest. Although we have presented the results obtained in the experimental validation of an adaptive proton therapy workflow, the same approach can be generalized and used for a variety of clinical innovations and workflow developments that require accurate assessment of point dose and/or average LET.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...