Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Interv Card Electrophysiol ; 51(2): 169-181, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29356922

RESUMO

PURPOSE: This study was conducted with the purpose of determining whether or not the potential technical advantages of multi-electrode mapping catheters in catheter ablation (CA) of ventricular tachycardia (VT) result in any relevant clinical benefit for VT patients. METHODS: A single-center VT study, having taken place from 2012 to 2014 using a standard 3.5-mm catheter (Thermocool SF® group 1) and from 2014 to 2016 using a 1-mm multi-electrode-mapping catheter (PentaRay® group 2), was conducted. The endpoint was the complete elimination of late potentials (LPs), local abnormal ventricular activities (LAVA), and VT non-inducibility. Follow-up consisted of device interrogation to monitor for VT recurrence. RESULTS: Out of 74 VT patients aged 64.5 ± 12.0 years (66 male [89.2%], 56 with ICM [75.7%], and 18 with NICM [24.3%)]), 48 patients (64.9%) were investigated in group 1 and 26 (35.1%) in group 2. Using the multi-point acquisition approach, a tendency to require less mapping time (group 1 65.2 ± 37.6 min, group 2 55.6 ± 34.4 min, p ns) was determined. During 12-month follow-up, 57 patients had freedom from VT recurrences (79.2%). The result was insignificant between the groups (38 patients (79.2%) in group 1 and 19 patients (73.1%) in group 2). CONCLUSIONS: In a single-center observational study, both conventional and high-density mapping approaches in VT patients are comparable in terms of procedure duration and outcome. Mapping time when using a multi-electrode catheter seems to have the tendency of being shorter. We should be encouraged to recruit more patients comparing the benefit of different catheter types.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Cateteres Cardíacos , Ablação por Cateter/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Ablação por Cateter/instrumentação , Distribuição de Qui-Quadrado , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
3.
J Arrhythm ; 33(3): 192-200, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28607614

RESUMO

BACKGROUND: The dominant single-shot procedure for Pulmonary Vein Isolation (PVI) is the Cryoballoon Ablation (CBA) technique using a spiral catheter (Achieve™, AC) for mapping and monitoring purposes. We hypothesized that Basket Catheters, such as the High Density Mesh Mapper (HDMM), with its high-density mapping properties, could detect Pulmonary Vein Potentials (PVPs) that the octapolar AC would not be able to identify. METHODS: Twenty-four patients (average age 61.8±10 years) with either paroxysmal or persistent atrial fibrillation (AF) (Paroxysmal AF or Persistent AF) were enrolled in the study. While the patients were in sinus rhythm, all pulmonary veins (PVs) were prospectively mapped both prior and subsequent to CBA with a 32-pole HDMM and an 8-pole AC. PVPs were recorded using both catheters, and their location was allocated to one of four PV quadrants. Then, the quadrant findings of the mapping catheters were compared. RESULTS: Mapping using the HDMM allowed for more precise identification of PVPs both before and after CBA compared to AC mapping. We identified an average of 83.6±4.8 PVPs in all four PVs (this means 20.9±10.5 PVPs /per single PV per patient [HDMM], 14.5±1.3 PVPs/in all four PVs and 3.6±2.7 PVPs /per single PV per patient [AC]) before ablation, thereby leading to a significant difference in the identification of PVPs per PV quadrant. Of 384 PV quadrants/24 patients analyzed, the HDMM identified PVPs in 279 and AC in only 192 quadrants (P<0.05). CONCLUSION: High-density mapping with a Basket Catheter, such as the HDMM, detects PVPs that remain undetected when using the standard AC catheter in CBA procedures.

4.
Cardiol Res ; 8(6): 293-303, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29317972

RESUMO

BACKGROUND: High-density mapping of ventricular tachycardia (VT) with PentaRay® (Biosense-Webster) provides high resolution with discrimination of local abnormal electrograms and slow conducting channels. We evaluate the feasibility of PentaRay® to characterize the anatomical substrate and assume an influence of the outcome despite limitations. METHODS: Over a 24-month period, 26 endocardial and four epicardial maps were obtained of 26 VT patients (18 ischemic cardiomyopathy (ICM, 69.2%) and 8 non-ischemic cardiomyopathy (NICM, 30.8%), age 65 ± 9 years). Catheter ablation (CA) was performed with the aim of transecting the isthmus. The endpoint was non-inducibility of any VT. Manual review of the maps was performed and focused on evaluating scarring, bipolar electrograms, and procedure times. RESULTS: In 55.6 ± 34.4 min, 1,085.9 ± 726.2 points were created. The mean ablation time was 50.8 ± 30.1 min. The endpoint was achieved in 12 patients (46.2%). The mean dense scar area and the mean patchy scar area were 49.4 ± 51.8 cm2 (range 0 - 190 cm2) and 14.7 ± 14.9 cm2 (range 0 - 110 cm2), respectively. Analyzing the learning curve, we found a tendency in decreasing procedure times. During the course of follow-up treatment averaging a 14-month period, device interrogation showed that 17 patients (65.4%) had remained free of any arrhythmia recurrence. CONCLUSION: The high-density maps with PentaRay® were safely created in a short period of time. Our manual review of the maps reveals limitations of current annotation criteria; nevertheless, medium-term outcomes were encouraging. Further prospective studies are required to validate our findings in a larger cohort of patients.

5.
Int J Med Sci ; 13(9): 664-72, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27647995

RESUMO

BACKGROUND: Atrial fibrillation (AF) represents a turning point in hypertrophic cardiomyopathy (HCM). Pulmonary Vein Isolation (PVI) with Radiofrequency Catheter Ablation (RFCA) is accepted to be successful in restoring sinus rhythm (SR) in HCM patients. The efficacy of cryoballoon (CB) therapy in HCM patients has not been studied so far. METHODS: 166 patients with AF underwent PVI with CB technology in our single center between 1/2012 and 12/2015. To evaluate the efficacy of the CB therapy in HCM patients, we compared their clinical outcome with those in "Non-HCM" AF patients in a 3 and 6 months follow-up. RESULTS: Out of 166 AF patients (65.7% paroxysmal AF, PAF), 4 patients had HCM and PAF (young males < 50 years). During the blanking period, 26 patients (15.8%) suffered from AF recurrence (11.0% PAF), including all HCM patients. The 6 months follow up of "Non-HCM" AF patients showed acceptable results (80% stable SR), whereas the HCM patients remained AF. IN CONCLUSION: Even if the CB provides advantages, the single device cannot be recommended in HCM patients because of early AF recurrences. Anyway, because of the specific hemodynamic changes in HCM patients with AF, ablation should be sought in an early state of its occurrence, then, however, preferably with RFCA.


Assuntos
Fibrilação Atrial/fisiopatologia , Cardiomiopatia Hipertrófica/fisiopatologia , Criocirurgia/métodos , Insuficiência Cardíaca/fisiopatologia , Adulto , Angioplastia Coronária com Balão/métodos , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/métodos , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Resultado do Tratamento
6.
Crit Care Med ; 38(1): 152-60, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19770739

RESUMO

OBJECTIVE: Patients undergoing percutaneous coronary intervention (PCI) for acute myocardial infarction with cardiogenic shock (CS) are often treated with intra-aortic balloon pump counterpulsation (IABP), even though the evidence to support this is limited. We determined whether IABP as an addition to PCI-centered therapy ameliorates multiorgan dysfunction syndrome (MODS) in patients with acute myocardial infarction complicated by CS. DESIGN: A prospective, randomized, controlled, open-label clinical trial recruiting patients between March 2003 and June 2004 (ClinicalTrials.gov ID NCT00469248). SETTING: Tertiary care university hospital. PATIENTS AND INTERVENTIONS: Forty-five consecutive patients with AMI and CS undergoing PCI were randomized to treatment with or without IABP. MEASUREMENTS AND MAIN RESULTS: Acute Physiology and Chronic Health Evaluation (APACHE) II scores (primary outcome measure), hemodynamic values, inflammatory markers, and plasma brain natriuretic peptide (BNP) levels (secondary outcomes) were collected over 4 days from randomization. The prospective hypothesis was that adding IABP therapy to "standard care" would improve CS-triggered MODS. The addition of IABP to standard therapy did not result in a significant improvement in MODS (measured by serial APACHE II scoring over 4 days). IABP use had no significant effect on cardiac index or systemic inflammatory activation, although BNP levels were significantly lower in IABP-treated patients. Initial and serial APACHE II scoring correlated with mortality better than cardiac index, systemic inflammatory state, and BNP levels in this group of patients. Nonsurvivors had significantly higher initial APACHE II scores (29.9 +/- 2.88) than survivors (18.1 +/- 1.66, p < .05). Nevertheless, discrepancies among patients within the groups cannot be ruled out and might interfere with our results. CONCLUSIONS: In this randomized trial addressing addition of IABP in CS patients, mechanical support was associated only with modest effects on reduction of APACHE II score as a marker of severity of disease, improvement of cardiac index, reduction of inflammatory state, or reduction of BNP biomarker status compared with medical therapy alone. However, the limitations of our present trial preclude any definitive conclusion, but request for a larger prospective, randomized, multicentered trial with mortality as primary end point.


Assuntos
Balão Intra-Aórtico/métodos , Insuficiência de Múltiplos Órgãos/prevenção & controle , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/cirurgia , APACHE , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Angiografia Coronária , Contrapulsação/métodos , Estado Terminal/mortalidade , Estado Terminal/terapia , Eletrocardiografia , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Probabilidade , Estudos Prospectivos , Medição de Risco , Fatores Sexuais , Choque Cardiogênico/complicações , Choque Cardiogênico/diagnóstico , Análise de Sobrevida , Resultado do Tratamento
7.
Aging Male ; 12(4): 113-8, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19909203

RESUMO

INTRODUCTION: The effects of testosterone have been extensively characterized, but little attention has been given to the timetable of occurrence of the various effects of testosterone. METHODS: The timetables of effects on sexual and psychological variables in 40 hypogonadal men receiving treatment with either parenteral testosterone enanthate (TE) or undecanoate (TU). RESULTS: Sexual thoughts/fantasies and sexual interest/desire/spontaneous morning erections emerged quickly and plateaued after 3 weeks. Total erections rose to a maximum over 9 weeks and then plateaued. Ejaculations per week/satisfaction with sex life rose over the first 3 weeks, increasing steadily to a plateau at 12 weeks. Depression scores decreased to reach a plateau after 6 weeks. Aggressiveness did not change. Scores of concentration improved and reached a plateau after 3 weeks in the group treated with TE and after 9 weeks in the group treated with TU. Good mood improved after 6-9 weeks. Positive effects on self-confidence appeared between 3-6 weeks and on fatigue after 9-12 weeks. CONCLUSION: Insight into the emergence of effects may be useful information for the patient and for the attending physician in monitoring clinical effects of testosterone treatment of hypogonadal men.


Assuntos
Afeto/efeitos dos fármacos , Androgênios/administração & dosagem , Hipogonadismo/tratamento farmacológico , Sexualidade/efeitos dos fármacos , Testosterona/administração & dosagem , Androgênios/metabolismo , Androgênios/uso terapêutico , Humanos , Masculino , Estudos Prospectivos , Inquéritos e Questionários , Testosterona/metabolismo , Testosterona/uso terapêutico , Fatores de Tempo
8.
Acute Card Care ; 10(1): 49-57, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17924229

RESUMO

OBJECTIVE: To investigate the haemodynamic effects of levosimendan in patients with cardiogenic shock (CS) complicating acute myocardial infarction in comparison to the effects of intra-aortic balloon counterpulsation (IABP). METHODS: 10 patients with intractable CS under standard therapy (including the use of PCI, inotropes, and vasopressors) received i.v. infusion of levosimendan (bolus 12 microg/kg i.v., followed by continuous infusion 0.1 microg/kg/min for 24 h). Haemodynamic effects were compared to the effects of IABP-placement added to standard care in 12 patients with CS. RESULTS: Within 24 h, both levosimendan and IABP produced a significant increase in cardiac index (CI) and cardiac power index and a decrease in systemic vascular resistance (SVR) (CI [l/min/m2] baseline 1.97+/-0.15, at 24 h 2.82+/-0.22 for levosimendan; baseline 1.98+/-0.17, at 24 h 2.66+/-0.08 for IABP; SVR [dyn*s*cm-5] baseline 1353+/-106, at 24 h 846+/-69 for levosimendan; baseline 1311+/-214, at 24 h 853+/-63 for IABP, respectively). After 3 h of treatment, CI and SVR had significantly improved in patients treated with levosimendan but not in the IABP-group (CI [l/min/m2] at 3 h 2.72+/-0.28 (+38%) for levosimendan versus 2.18+/-0.15 (+10%) for IABP). CONCLUSION: Infusion of levosimendan in acute CS results in early and sustained haemodynamic improvement. Short-term haemodynamic effects compare favourably with those seen after invasive IABP placement.


Assuntos
Cardiotônicos/farmacologia , Hemodinâmica/efeitos dos fármacos , Hidrazonas/farmacologia , Infarto do Miocárdio/complicações , Piridazinas/farmacologia , Choque Cardiogênico/terapia , Idoso , Angioplastia Coronária com Balão , Feminino , Humanos , Balão Intra-Aórtico , Masculino , Contração Miocárdica/efeitos dos fármacos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Artéria Pulmonar/fisiopatologia , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Simendana , Fatores de Tempo , Resistência Vascular/efeitos dos fármacos
9.
Crit Care Med ; 35(12): 2732-9, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17893627

RESUMO

OBJECTIVES: Levosimendan, a novel inodilator, has been shown to improve hemodynamic function in patients with acute exacerbation of congestive heart failure. We wanted to determine the hemodynamic effects of levosimendan following ineffective conventional therapy (with catecholamines) in patients with cardiogenic shock following myocardial infarction. DESIGN: Observational hemodynamic study. SETTING: Tertiary care center university hospital. PATIENTS: Fifty-six patients with cardiogenic shock secondary to myocardial infarction were treated with percutaneous revascularization (intra-aortic balloon pump where appropriate) and commenced on conventional inotropic therapy. INTERVENTIONS: Patients with persisting cardiogenic shock 24 hrs after revascularization were additionally treated with levosimendan (rapid bolus of 12 microg/kg for 10 mins, then 0.05-0.2 mug/kg/min for 24 hrs) (n = 25). MEASUREMENTS AND MAIN RESULTS: With conventional catecholamine therapy (norepinephrine and dobutamine), we observed only marginal improvement in mean arterial pressure or cardiac index. In contrast, the addition of levosimendan produced a significant increase in cardiac index (2.1 +/- 0.56 to 3.0 +/- 1.11 L/min/m2, p < .01) and cardiac power index (0.32 +/- 0.08 to 0.44 +/- 0.18 W, p < .01), whereas systemic vascular resistance decreased significantly (1208 +/- 333 to 858 +/- 299 dyne.sec.cm(-5), p < .01). There was no significant change in blood pressure during levosimendan treatment. Hemodynamic improvement was sustained after levosimendan infusion was stopped. CONCLUSIONS: Levosimendan infusion in cardiogenic shock following acute myocardial infarction improved cardiovascular hemodynamics without leading to hypotension.


Assuntos
Cardiotônicos/farmacologia , Hemodinâmica/efeitos dos fármacos , Hidrazonas/farmacologia , Piridazinas/farmacologia , Choque Cardiogênico/tratamento farmacológico , Angioplastia Coronária com Balão , Cardiotônicos/efeitos adversos , Cardiotônicos/uso terapêutico , Catecolaminas/farmacologia , Catecolaminas/uso terapêutico , Dobutamina/farmacologia , Dobutamina/uso terapêutico , Feminino , Humanos , Hidrazonas/efeitos adversos , Hidrazonas/uso terapêutico , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Piridazinas/efeitos adversos , Piridazinas/uso terapêutico , Choque Cardiogênico/terapia , Simendana
10.
Europace ; 9(9): 744-50, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17496288

RESUMO

AIMS: Optimizing cardiac resynchronization therapy (CRT) devices has become more complex since modification of both atrioventricular (AV) and interventricular (VV) stimulation intervals has become possible. The current paper presents data from the routine use of impedance cardiography (IC)-based cardiac output (CO) measurements to guide the optimization of AV- and VV-interval timing of CRT devices. METHODS AND RESULTS: Forty-six patients with heart failure (left ventricular ejection fraction <35%, New York Heart Association (NYHA) III-IV) and left bundle branch block (>130 ms) in sinus rhythm were evaluated 3-5 days after implantation of a CRT device by means of IC. CO was measured without pacing and with biventricular pacing using a standard protocol of VV- and AV-interval modification from -60 to +60 ms and 80 to 140 ms, respectively, in 20 ms steps. Mean CO without pacing was 3.66 +/- 0.85 L/min and significantly increased to 4.40 +/- 1.1 L/min (P<0.05) with simultaneous biventricular pacing and an AV interval of 120 ms. 'Optimizing' both VV and AV intervals further increased CO to 4.86 +/- 1.1 L/min (P<0.05). Maximum CO was measured in most patients with left ventricular pre-excitation. The proportion of 'non-responders' to CRT was reduced by 56% following AV- and VV-interval modification using IC guidance. CONCLUSION: Modification of both AV and VV intervals in patients with a CRT device significantly improves CO compared with standard simultaneous biventricular pacing and no pacing. IC is a useful non-invasive technique for guiding this modification. Marked variability of optimal AV and VV intervals between patients requires optimization of these intervals for each patient individually.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiografia de Impedância/métodos , Desfibriladores Implantáveis , Ecocardiografia Doppler , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Idoso , Débito Cardíaco/fisiologia , Cardiografia de Impedância/instrumentação , Cardiologia/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...