Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Hellenic J Cardiol ; 57(1): 33-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26856199

RESUMO

INTRODUCTION: Cardiac rhythm management devices (CRMDs) have proven their clinical effectiveness for patients with heart rhythm disorders. Little is known about safety and complication rates during the implantation of these devices. This study demonstrated the complication rates related to CRMD implantation, and estimated the additional hospital stay and cost associated with the management of complications. METHODS: During a period of one year, a total of 464 consecutive recipients underwent CRMD implantation and were followed for 2 years. Finally, data were analyzed for 398 patients who completed the two-year follow up, resulting in a total of 796 patient-years. RESULTS: Of the 201 patients with initial pacemaker (PM) implantations, 6 (2.99%) had seven complications (5 patients had lead dislodgement, 1 of them twice), and 1 patient developed pocket infection. Of the 117 PM replacements, 1 (0.85%) patient developed a complication (pocket erosion). Two patients with complications (1 with an initial PM and 1 with a replacement) died before completing the follow up for reasons unrelated to cardiac causes. There were no complications in either initial implantations (69 patients) or replacements (11 patients) of implantable cardioverter-defibrillators. The average prolongation of the hospital stay was 7 days, ranging from 1 to 35 days, resulting in 17,411 of total additional direct hospital costs. CONCLUSION: This study found relatively low rates of complications in patients undergoing CRMD implantation, initial or replacement, in our center, compared with other studies. The additional hospitalization days and costs attributable to these complications depend on the nature of the complication.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Tempo de Internação/economia , Marca-Passo Artificial/efeitos adversos , Arritmias Cardíacas/economia , Efeitos Psicossociais da Doença , Desfibriladores Implantáveis/economia , Feminino , Humanos , Masculino , Marca-Passo Artificial/economia , Complicações Pós-Operatórias , Estudos Prospectivos , Inquéritos e Questionários , Resultado do Tratamento
2.
Europace ; 17(10): 1563-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25851726

RESUMO

AIM: Long-term right ventricular apical (RVA) pacing may lead to left ventricular (LV) remodelling and heart failure. This study assessed changes in the expression of genes regulating LV contractile function and hypertrophy, after permanent RVA pacing and investigated whether such changes proceed or even predict LV remodelling. METHODS AND RESULTS: We enrolled 52 consecutive patients (age 79.1 ± 7.7 years, 34 males) who underwent pacemaker implantation for bradycardic indications: Group A, 24 individuals with atrioventricular conduction disturbances and group B, 28 patients with sinus node disease. In group A, peripheral blood mRNA levels of gene sarcoplasmic reticulum calcium ATPase decreased at 3, 6, and 12 months' follow-up, while α-myosin heavy chain (MHC) decreased and ß-MHC increased until 6 months follow-up. In this group, 25% of patients demonstrated significant LV remodelling. At 4 years, LV end-systolic diameter increased from 29.67 ± 3.39 mm at baseline to 35.38 ± 4.22 mm, LV end-diastolic diameter increased from 50 ± 4.95 to 56.71 ± 5.52 mm, and ejection fraction declined from 63.04 ± 10.22 to 52.83 ± 10.81%. Early alterations in gene expression were associated with a deterioration in LV function and geometry that became apparent months later. In group B, echocardiographic indexes and mRNA levels of the evaluated genes demonstrated no statistically significant changes. CONCLUSIONS: Permanent RVA pacing in patients with preserved ejection fraction is associated with alterations in the expression of genes regulating LV contractile function and hypertrophy, measured in the peripheral blood. These alterations are traceable at an early stage, before echocardiographic changes are apparent and are associated with LV remodelling that becomes evident in the long term.


Assuntos
Miosinas Cardíacas/sangue , Ventrículos do Coração/fisiopatologia , Cadeias Pesadas de Miosina/sangue , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático/sangue , Síndrome do Nó Sinusal/complicações , Função Ventricular Esquerda/genética , Remodelação Ventricular/genética , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Ecocardiografia , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Marca-Passo Artificial , Estudos Prospectivos , Volume Sistólico
3.
Europace ; 15(3): 366-75, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23148117

RESUMO

AIMS: The aim of the present study is to estimate the procedure (implantation) cost, the total hospitalization cost and annual follow-up cost, in patients subjected to pacemaker (PM) and implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS: A single-center, prospective, cost-of-illness study was conducted between August 2008 and July 2009. In total, 464 consecutive patients were recruited (370 were subjected to PM implantation and 94 to ICD implantation). Resource data were assessed at patients' enrolment in the study and at 6th and 12th months of patients' follow-up. Then, the procedure cost, the total hospitalization cost as well as the annual patients' follow up costs were calculated using a bottom-up approach. The mean (95% confidence interval) procedure cost of PM and ICD implantation (including the costs of devices, electrodes, other supplies, and personnel's time) was calculated to be €1803 (€1758-€1858) and €13,521 (€13,153-€13,892), respectively. The mean total hospitalization cost (including procedure cost, hospitalization cost, cost of laboratory and imaging diagnostic examinations and the indirect cost attributed to productivity lost due to patient's hospitalization) was €3926 (€3711-€4167) for PM and €17,764 (€16,852-€18,692) for ICD. The mean annual cost (direct and indirect) was €1816 (€1433-€2421) for PM and €2819 (€2115-€3703) for ICD. No difference was detected in the annual cost between patients with initial implantation and replacement. CONCLUSION: These data revealed that although these devices are associated with a relatively high upfront cost, the annual societal cost following the implantation is low. Therefore, implantation of such devices should be encouraged since these devices reduce the morbidity and mortality without a high economic burden to society.


Assuntos
Arritmias Cardíacas/economia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/economia , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Custos Hospitalares , Marca-Passo Artificial/economia , Centros de Atenção Terciária/economia , Absenteísmo , Idoso , Idoso de 80 Anos ou mais , Assistência Ambulatorial/economia , Distribuição de Qui-Quadrado , Continuidade da Assistência ao Paciente/economia , Redução de Custos , Efeitos Psicossociais da Doença , Análise Custo-Benefício , Diagnóstico por Imagem/economia , Custos de Medicamentos , Cardioversão Elétrica/instrumentação , Feminino , Grécia , Hospitais Universitários/economia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Econômicos , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Hellenic J Cardiol ; 51(4): 368-73, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20650837

RESUMO

Bifurcation lesions of native coronary arteries are common in daily practice and different strategies for percutaneous coronary intervention have been suggested for their treatment. The "crush" technique, with the use of drug-eluting stents in both the main and the side branch, is a relatively simple procedure that ensures complete lesion coverage, even for bifurcations that have extensive disease within the side branch. We present the case of a bifurcation lesion in a Y-shaped saphenous venous graft in a patient who had previously undergone coronary artery bypass graft surgery. The literature lacks reports regarding the management of such patients. Implementation of the "crush" technique in the specific case resulted in a satisfactory angiographic and long-term clinical outcome.


Assuntos
Angioplastia Coronária com Balão , Prótese Vascular/efeitos adversos , Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Oclusão de Enxerto Vascular/cirurgia , Veia Safena/transplante , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Masculino , Radiografia , Recidiva
6.
Sleep Med ; 11(2): 149-53, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20083431

RESUMO

BACKGROUND: Little is known about sleep quality in patients with acute coronary syndromes (ACS) admitted to the coronary care unit (CCU). The aim of this study was to assess nocturnal sleep in these patients, away from the CCU environment, and to evaluate potential connections with the disease process. METHODS: Twenty-two patients with first ever ACS, who were not on sedation or inotropes, underwent a full-night polysomnography (PSG) in our sleep disorders unit within 3 days of the ACS and follow-up PSGs 1 and 6 months later. RESULTS: PSG parameters showed a progressive improvement over the study period. There was a statistically significant increase in total sleep time (TST), sleep efficiency, slow wave sleep (SWS), and rapid eye movement (REM) sleep, while arousal index, wake after sleep onset (WASO) and sleep latency decreased. Six months after the acute event, sleep architecture was within the normal range. CONCLUSIONS: Patients with ACS have marked alterations in sleep macro- and micro-architecture, which have a negative influence on sleep quality. The changes tend to disappear over time, suggesting a relationship with the acute phase of the underlying disease.


Assuntos
Síndrome Coronariana Aguda/fisiopatologia , Sono/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Síndromes da Apneia do Sono/fisiopatologia , Fases do Sono/fisiologia , Transtornos do Sono-Vigília/fisiopatologia , Sono REM/fisiologia , Volume Sistólico/fisiologia
7.
Europace ; 11 Suppl 5: v77-81, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19861395

RESUMO

Right ventricular apical (RVA) stimulation, although beneficial in the treatment of symptomatic bradycardia, has proven detrimental in a substantial percentage of pacemaker recipients, leading to iatrogenic deterioration of left ventricular structure and function. Alternative right ventricular pacing sites appeared advantageous but their superiority has not been proven. Biventricular stimulation is effective in reducing ventricular dyssynchrony in subgroups of heart failure patients, improving their functional capacity, morbidity, and mortality. Therefore, it seems logical that this pacing strategy, by eliminating ventricular dyssynchrony, could play an important role in preventing the deleterious effects of chronic RVA stimulation in patients with normal hearts who undergo cardiac pacing for bradycardia indications. Preliminary investigations have yielded encouraging results, but further studies with harder endpoints such as quality of life, morbidity, and mortality are necessary to clarify the potentially advantageous effect of biventricular stimulation in paced patients with normal hearts.


Assuntos
Estimulação Cardíaca Artificial/métodos , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Fascículo Atrioventricular/fisiologia , Sistema de Condução Cardíaco/fisiologia , Humanos , Contração Miocárdica/fisiologia
8.
Hellenic J Cardiol ; 50(2): 144-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19329417

RESUMO

We describe the case of a patient with hypertrophic cardiomyopathy who had recurrent syncopal episodes, the cause of which remained unexplained despite a thorough evaluation. Two years after his first evaluation, an implantable loop recorder revealed asymptomatic episodes of advanced second degree atrioventricular block while the patient was awake. Although a permanent pacemaker was implanted, the patient continued to suffer syncopal episodes, during which the pacemaker recorded episodes of ventricular tachycardia. Accordingly, the device was upgraded to an implantable cardioverter-defibrillator.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Frequência Cardíaca/fisiologia , Monitorização Fisiológica/métodos , Síncope/diagnóstico , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/terapia , Desfibriladores Implantáveis , Diagnóstico Diferencial , Ecocardiografia , Cardioversão Elétrica/métodos , Eletrocardiografia Ambulatorial , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Síncope/etiologia , Síncope/terapia , Fatores de Tempo
9.
Cardiovasc Drugs Ther ; 21(5): 357-65, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17909956

RESUMO

BACKGROUND: Using a goat animal model, we tested the hypothesis that angiotensin-II inhibition reduces fibrotic degeneration of both the atrial and ventricular myocardium as well as AF induction susceptibility. METHODS: We studied three groups of five goats over a 6-month period. The study animals in the first two groups were implanted with a pacemaker capable of maintaining AF with burst pacing. Additionally, in one group, goats were administered candesartan (AF+candesartan group). The third group (SR group) of animals served as control. Animals were tested for AF induction on day 0, 1, 30, 90 and 180. A "Vulnerability Index" (VI) for AF induction was calculated, defined as the ratio of total time in AF per number of bursts needed to induce sustained AF, in each session. At the end of the study, all four heart chambers were examined and fibrosis quantified. RESULTS: Both AF goat groups developed cardiomegaly due to tachy-cardiomyopathy. Although, the VI was significantly increased in AF group over time (28.8+/-43 to 284.7+/-291, p=0.045), this was not the case for AF+candesartan group (30.3+/-40 to 170.8+/-243, p=0.23). Histology revealed a significant increase of fibrous tissue in goats with induced AF, noticeable in all four heart chambers, compared to controls. However, the degree of fibrosis was significantly lower in AF animals on candesartan. CONCLUSIONS: Our study demonstrated a beneficial effect of angiotensin II inhibition on tachyarrhythmia-induced ventricular fibrosis. It is also consistent with previous studies indicating a reduction in burst-induced AF susceptibility in goats and confirms the favorable effects in atrial structural remodeling.


Assuntos
Fibrilação Atrial/etiologia , Benzimidazóis/administração & dosagem , Fibrose/patologia , Miocárdio/patologia , Receptor Tipo 1 de Angiotensina/efeitos dos fármacos , Taquicardia/complicações , Tetrazóis/administração & dosagem , Animais , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/patologia , Benzimidazóis/farmacologia , Compostos de Bifenilo , Estimulação Cardíaca Artificial , Modelos Animais de Doenças , Feminino , Fibrose/etiologia , Fibrose/prevenção & controle , Cabras , Masculino , Tetrazóis/farmacologia , Remodelação Ventricular/efeitos dos fármacos
10.
Hellenic J Cardiol ; 47(1): 13-20, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16532711

RESUMO

INTRODUCTION: Sleep apnoea, which constitutes a major social problem because of its high prevalence and its emerging association with cardiovascular morbidity and mortality, is known to affect autonomic nervous system activity. We assessed the hypothesis that treatment of sleep apnoea patients with continuous positive airway pressure (CPAP) alters the indices of heart rate variability (HRV) that reflect sympathetic and parasympathetic autonomic nervous system activity. METHODS: We studied 26 patients (18 men, aged 49.2 +/- 7.6 years) with obstructive sleep apnoea-hypopnoea syndrome. In all patients, a 24-hour Holter recording was obtained one week before initiation of CPAP treatment and another one two months later. From these recordings we assessed the time domain indices of HRV (pNN50, rMSSD, SDNN, SDANN, SD) during the day (08:00-23:00) and during the night hours (23:00-08:00) as well as their post-treatment changes. The same HRV indices were also assessed in a group of 19 age and sex matched controls, without sleep apnoea. RESULTS: No significant differences in the HRV indices were observed during the daytime hours, while during the night both pNN50 and rMSSD were significantly higher in patients compared to controls (19.5 +/- 12.5 vs. 13.8 +/- 9.7, p=0.001, for pNN50 and 54.7 +/- 23.1 vs. 44.0 +/- 15.9, p=0.001, for rMSSD, for patients and controls respectively). No such differences were observed in any of the monitored indices following CPAP treatment. CONCLUSIONS: The indices that reflect parasympathetic activity are increased during the night in patients with obstructive sleep apnoea syndrome. CPAP treatment reduces the night time vagal indices of HRV to resemble those of normal controls. The reduction of parasympathetic activity may be one of the mechanisms responsible for the alleviation of bradyarrhythmic episodes following the initiation of CPAP therapy.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Frequência Cardíaca/fisiologia , Síndromes da Apneia do Sono/fisiopatologia , Síndromes da Apneia do Sono/terapia , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Nervo Vago/fisiopatologia , Adulto , Índice de Massa Corporal , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Prospectivos , Função Ventricular
11.
N Engl J Med ; 353(24): 2568-77, 2005 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-16354893

RESUMO

BACKGROUND: The role of atrial overdrive pacing (AOP) in sleep apnea remains uncertain. We prospectively evaluated the effect of AOP after 24 hours and after one month in patients with the obstructive sleep apnea-hypopnea syndrome and compared it with the use of nasal continuous positive airway pressure (n-CPAP). METHODS: We studied 16 patients with a moderate or severe case of the obstructive sleep apnea-hypopnea syndrome (baseline mean apnea-hypopnea index, 49) and normal left ventricular systolic function in whom a dual-chamber pacemaker had been implanted. After 48 hours, the patients were randomly assigned to AOP (pacing at 15 bpm above the spontaneous mean nocturnal heart rate) or backup atrial pacing (pacing at a heart rate below 40 bpm); the latter group began n-CPAP therapy one day later. After one month, the two groups switched therapies and were followed for an additional month. Polysomnographic studies were performed at baseline, on the first night after randomization, at crossover, and at the end of the study. RESULTS: During AOP, no significant changes were observed in any of the respiratory variables measured. The change in the apnea-hypopnea index at one month with AOP was +0.2 (95 percent confidence interval, -2.7 to +2.3; P=0.87). In contrast, all variables improved significantly after one month of n-CPAP (change in the apnea-hypopnea index, -46.3; 95 percent confidence interval, -56.2 to -36.5; P<0.001). CONCLUSIONS: Nasal continuous positive airway pressure therapy is highly effective for the treatment of the obstructive sleep apnea-hypopnea syndrome, whereas AOP has no significant effect.


Assuntos
Estimulação Cardíaca Artificial/métodos , Pressão Positiva Contínua nas Vias Aéreas , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Estudos Cross-Over , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Polissonografia , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/fisiopatologia , Resultado do Tratamento
12.
Hellenic J Cardiol ; 46(2): 158-60, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15847139

RESUMO

Ventricular septal defect (VSD) is the most frequent congenital heart disease in adults, with equal distribution in both sexes, and has an incidence of about 20% in children. In adults congenital VSDs represent about 10% of all cases and the mortality at age 60 is around 75%. For elderly patients >80 years old only one living case has been reported previously. Here we describe an 86-year-old patient, totally asymptomatic, with a muscular type of VSD that showed interesting, canal-like echocardiographic images.


Assuntos
Ecocardiografia Doppler/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Cardiopatias Congênitas/fisiopatologia , Comunicação Interventricular/fisiopatologia , Humanos , Masculino , Monitorização Fisiológica , Medição de Risco , Índice de Gravidade de Doença
13.
Pacing Clin Electrophysiol ; 27(10): 1371-7, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15511246

RESUMO

Spectral analysis of heart rate variability was used to compare the changes in autonomic function during tilting in young and older patients with vasovagal syncope. Twenty-four young (age 28 +/- 8 years) and 31 older (56 +/- 5 years) patients with unexplained syncope and a positive tilt test and 25 controls (age 48 +/- 12 years) were included in the study. Frequency-domain measurements of the low (LF) (0.06-0.15 Hz) and high (HF) (0.15-0.40 Hz) frequency bands and the ratio of LF to HF were computed from Holter recordings for 4-minute intervals before and immediately after tilting and just before the end in all groups. Syncopal patients showed a different pattern of response to tilting from controls in all spectral indexes. Young and older patients showed the same pattern of changes in all measurements, even though certain differences were observed. The LF after tilting reduced more in the older (-20 +/- 7% vs -14 +/- 5%, P < 0.001), while HF reduced more in young patients (-17 +/- 8% vs -8 +/- 3%, P < 0.001). Young patients showed mainly a cardioinhibitory type (71%) of response whereas a vasodepressor type response predominated (68%) in the older patients. The autonomic nervous system appears to play an important role in the pathophysiological mechanism of vasovagal syncope. This role is similar in young and in older patients and this should be taken into account in the therapeutic approach to the condition. Specific differences between age groups may be related to the type of vasovagal syncope.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Síncope Vasovagal/fisiopatologia , Adulto , Fatores Etários , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Teste da Mesa Inclinada
14.
Eur Heart J ; 25(12): 1070-6, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15191779

RESUMO

AIM: In this new era of insertable loop recorders, we studied obstructive sleep apnoea-hypopnoea syndrome (OSAHS) patients in order to evaluate their arrhythmias and the beneficial effect of Continuous Positive Airway Pressure treatment (CPAP), over a long-term period. METHODS AND RESULTS: We enrolled 23 patients (16 men, 50 +/- 11 years) with moderate and severe OSAHS. In all patients, an insertable loop recorder capable of monitoring the heart rhythm for 16 months was implanted. Cardiac pauses >3 s and bradycardic episodes <40 bpm during a 2-month period before, and for 14 months after, the CPAP application, were noted. In each period, the patients underwent two 24-h Holter recordings. Before treatment, 11 patients (47%) revealed severe cardiac rhythm disturbances, mostly nocturnal. Holter recordings showed disturbances in only 3 (13%) patients (P=0.039), those in whom the insertable loop device had recorded frequent episodes. Eight weeks after the initiation of treatment, the total number of the recorded episodes tended to decrease while, during the last 6 months of the follow-up, no episodes were recorded. CONCLUSION: Approximately half of OSAHS patients evidence severe cardiac rhythm disturbances, which are significantly reduced by CPAP. Holter recordings seem unable to precisely describe the incidence of severe brady-arrhythmias and the effect of treatment.


Assuntos
Bradicardia/etiologia , Respiração com Pressão Positiva/métodos , Síndromes da Apneia do Sono/complicações , Bradicardia/terapia , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Estudos Prospectivos , Síndromes da Apneia do Sono/terapia , Estatísticas não Paramétricas
15.
J Am Soc Echocardiogr ; 17(2): 139-45, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14752488

RESUMO

BACKGROUND: Early color M-mode Doppler flow propagation (Ep) through the left ventricle (LV) has been proposed as a useful noninvasive index for assessing LV relaxation, whereas data concerning late velocity propagation (Ap) is lacking. METHODS: We studied 51 patients with delayed relaxation (group I) and 50 with pseudonormal filling pattern (group II). Another 51 aged-matched healthy persons served as the control group. RESULTS: Patients showed increased left atrial dimensions, atrial wave of the pulmonary vein flow, and Ap, and reduced LV ejection fraction, Ep, and Ep/Ap ratio compared with the control group. Patients in group II revealed increased left atrial dimensions (P =.001), atrial wave of the pulmonary vein flow (P <.001), and Ep/Ap ratio (P <.001), and reduced LV ejection fraction and Ap (P <.001) compared with group I. Regression analysis showed that the strongest independent variable distinguishing normal from pseudonormal filling pattern was the Ep/Ap ratio. CONCLUSION: Ap evaluation offers a new diagnostic diastolic index, especially in the field of the pseudonormal pattern where the separation from normal is difficult.


Assuntos
Ecocardiografia Doppler em Cores , Insuficiência Cardíaca/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Diástole , Insuficiência Cardíaca/fisiopatologia , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
16.
Chest ; 124(1): 233-41, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12853528

RESUMO

STUDY OBJECTIVES: Asynchronous ventricular activation, as induced by ventricular pacing, is known to affect left ventricular (LV) systolic and diastolic function and myocardial blood flow. However, it is not clear whether the long-term disturbances it causes are reversible after the restoration of the normal ventricular activation sequence. DESIGN: In this study, we used the conductance catheter method and a Doppler guidewire to assess the changes in LV mechanics, and correspondingly in myocardial blood flow, after the restoration of the normal ventricular activation sequence in patients with long-term right ventricular apical pacing. PATIENTS: Sixteen patients (mean [+/- SD] age, 61 +/- 11 years; 9 men) with right ventricular apical stimulation and complete ventricular pacing capture for a very long period were studied. In eight patients, we analyzed pressure-volume loops before and immediately after the restoration of the normal ventricular activation sequence, and in the remaining eight patients the myocardial blood flow and flow reserve were analyzed. MEASUREMENTS AND RESULTS: End-systolic elastance (Ees) [5.503 +/- 0.6 vs 4.287 +/- 0.28 mm Hg/mL, respectively; p = 0.003] and its ratio to effective arterial elastance (1.63 +/- 0.51 vs 2.00 +/- 0.64, respectively; p = 0.009), which are indexes of systolic function and ventriculoarterial coupling, respectively, improved significantly after restoration of the normal ventricular activation sequence. Indexes of diastolic function and the predicted myocardial oxygen consumption (MO(2)) showed no clear change. Coronary flow in the dominant coronary artery increased significantly (46.55 +/- 14.12 vs 71.55 +/- 27.53 mL/min, respectively; p = 0.002), while the coronary flow reserve in the same artery decreased (3.5 +/- 1.0 vs 2.6 +/- 0.5, respectively; p = 0.008). CONCLUSIONS: The restoration of a normal activation sequence after long-term ventricular asynchrony enhances acutely contractile function without affecting MO(2). These changes in LV function do not appear to have causal relationships with myocardial blood flow changes.


Assuntos
Circulação Coronária/fisiologia , Sistema de Condução Cardíaco/fisiologia , Marca-Passo Artificial , Função Ventricular Esquerda/fisiologia , Estimulação Cardíaca Artificial/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Fatores de Tempo , Função Ventricular Direita/fisiologia
17.
Pacing Clin Electrophysiol ; 26(5): 1202-7, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12765447

RESUMO

The aim of this study was to investigate myocardial perfusion and adrenergic innervation in patients with intraventricular conduction disturbances and to detect any changes caused by alteration of the ventricular activation sequence as a result of right ventricular apical pacing. We studied 15 patients with right bundle branch block (RBBB) and left anterior fascicular block (LAFB), while 15 healthy individuals served as controls. All patients underwent planar and single-photon emission computed tomography (SPECT) myocardial imaging after intravenous infusion of 5mCi 123I-metaiodobenzylguanidine (123I-MIBG) and a SPECT thallium201 myocardial perfusion study before and 3 months after pacemaker implantation. The heart to mediastinum ratio was calculated during the 123I-MIBG study in order to assess the global cardiac sympathetic activity and was significantly smaller in patients than in controls (P < 0.001). Patients with RBBB and LAFB revealed regional adrenergic innervation defects, mostly in the inferior and posterior walls. After a medium-term pacing period, a redistribution of 123I-MIBG uptake was detected, with aggravation of adrenergic innervation defects in the apical and posterior walls and amelioration in septal and anterior walls. Five patients showed perfusion defects that remained unchanged after pacing. Two others displayed mild myocardial perfusion defects that did not exist before pacing. In conclusion, patients with RBBB and LAFB reveal global and regional disturbances of myocardial adrenergic innervation, which shows redistribution as a result of the altered propagation of the ventricular electrical activation. To a smaller degree these patients reveal myocardial perfusion disturbances in which pacing has a limited medium-term effect.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Circulação Coronária , Ventrículos do Coração/inervação , Marca-Passo Artificial , Idoso , Análise de Variância , Bloqueio de Ramo/fisiopatologia , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único
18.
Pacing Clin Electrophysiol ; 25(7): 1061-5, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12164447

RESUMO

This study evaluated the possibility of diagnosing chronic myocardial infarction in the presence of the pacing electrocardiogram. Forty-five patients with known myocardial infarction (anterior 23, inferior 22) and 26 healthy controls were studied. After coronary angiography, pacing was applied from the right ventricular apex, and the sensitivity, specificity, and average diagnostic accuracy of five criteria on the paced electrocardiogram were assessed: (1) Notching 0.04 second in duration in the ascending limb of the S wave of leads V3, V4, or V5 (Cabrera's sign); (2) Notching of the upstroke of the R wave in leads I, aVL, or V6 (Chapman's sign); (3) Q waves > 0.03 second in duration in leads I, aVL, or V6; (4) Notching of the first 0.04 second of the QRS complex in leads II, III, and aVF; (5) Q wave > 0.03 second in duration in leads II, III, and aVF. The most sensitive criteria, for anterior and inferior myocardial infarctions were Cabrera's and Chapman's (91.1 and 86.6%, respectively). All criteria had low specificity (range 42.3-69.2%). The combination of Cabrera's and Chapman's sign decreased the sensitivity to 77.7%, but increased specificity to 82.2%. The sensitivity and specificity of all the criteria were independent of the myocardial infarction site. In paced patients, the application of electrocardiographic criteria, and especially the combination of Cabrera and Chapman, provides useful clinical information in recognizing prior myocardial infarction but not in assigning the specific infarct site.


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia , Infarto do Miocárdio/diagnóstico , Estudos de Casos e Controles , Doença Crônica , Angiografia Coronária , Diagnóstico Diferencial , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
19.
Chest ; 121(6): 2063-6, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12065379

RESUMO

A case of congenital absence of the left pulmonary artery, in which perfusion of the affected lung was accomplished via an arterial shunt from the circumflex coronary artery, is discussed. Data from myocardial perfusion scintigraphy showed that myocardial perfusion was unaffected by the existence of the shunt, largely because the flow through the shunt occurred mainly during systole.


Assuntos
Anormalidades Múltiplas/fisiopatologia , Circulação Colateral , Circulação Coronária , Anomalias dos Vasos Coronários/fisiopatologia , Artéria Pulmonar/anormalidades , Artéria Pulmonar/fisiopatologia , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...