Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(23)2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36501824

RESUMO

Investigation of the intrinsic magnetic field of austenitic biomaterial specimens after various heat-treatment processes and mechanical deformation is a matter in this study. Both heat-treatment and mechanical deformation influences are under investigation. A new approach incorporates innovative solutions with the goal to increase the resolution of gained signals in contrast to conventional methods. The proposed procedure was tested on real material specimens. A magnetic field sensor (fluxgate type) was used for this purpose. The presented results clearly show that gained signals can be increased when the appropriate probe instrumentation is used, and the characteristics are further mathematically processed.


Assuntos
Materiais Biocompatíveis , Aço Inoxidável , Campos Magnéticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...