Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Lab Med ; 39(4): 388-395, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30809985

RESUMO

BACKGROUND: It is very important to accurately enumerate CD34-positive (CD34+) cells for successful hematopoietic stem cell transplantation (HSCT). We evaluated the ability of the newly developed image based-immunofluorescence cell counter ADAMII (NanoEntek, Seoul, Korea) to enumerate CD34+ cells, which was improved through simultaneous CD45 analysis. METHODS: We enumerated CD34+ cells with ADAMII using 19 peripheral blood (PB) and 91 leukapheresis samples from HSCT donors. Analytical performance, including precision and linearity, was analyzed, and sample stability during storage was evaluated. Viable CD34+ cell count (vCD34) and viable CD45+ cell count (vCD45) and the percentage of viable CD34+ cells among viable CD45+ cells (CD34/CD45) as measured by ADAMII were compared with the corresponding values from two flow cytometry assays, using regression analysis. RESULTS: ADAMII demonstrated acceptable precision, as CV values of vCD34 from six samples with different counts were all <10% (range: 3.49-9.51%). CV values of the vCD45 and CD34/45 ranged from 4.03% to 9.67% and from 2.48% to 10.07%, respectively. The linearity of vCD34 showed an excellent R² value (0.99) when analyzed using the intended count and flow cytometry data. The ADAMII and two flow cytometry-based assays generated very similar data for the PB and leukapheresis samples. CONCLUSIONS: ADAMII demonstrated excellent performance for use as a routine clinical assay in terms of CD34+ cell enumeration from PB and leukapheresis samples. Moreover, it could be used as a point-of-care-test for determining mobilization time and predicting an adequate apheresis stem cell product.


Assuntos
Antígenos CD34/metabolismo , Citometria de Fluxo/métodos , Células-Tronco Hematopoéticas/citologia , Células-Tronco Hematopoéticas/metabolismo , Humanos , Antígenos Comuns de Leucócito/metabolismo , Testes Imediatos , Kit de Reagentes para Diagnóstico , Análise de Regressão
2.
Technol Health Care ; 26(5): 867-871, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30040773

RESUMO

BACKGROUND: Although AIDS-related mortality has declined since the introduction of antiretroviral therapy (ART), HIV/ AIDS patients are predominantly present in developing countries that lack high-cost diagnostic devices and human expertise. OBJECTIVE: New methods for counting CD4+ cells cost-effectively are needed to replace conventional flow cytometry-based diagnosis. METHODS: We developed a CD4+ cell analyzer, ADAMII, which is a benchtop fluorescence image-based CD3+/4+ cell counting analyzer. It bears a three-channel light source and performs CD3+/4+ counting assays. The automatic 3D stage captures a maximum of 136 images that are subsequently processed and analyzed using a software integrated into the system. RESULTS: Results obtained using ADAMII were compared with data obtained by conventional methods using a FACSCalibur flow cytometer and the point-of-care PIMA CD4 analyzer. Both comparisons between ADAMII vs. FACS and ADAMII vs. PIMA data yielded a strong correlation with an R2 value of 0.98, which ensures the feasibility of CD4 test by ADAMII. CONCLUSIONS: The proposed method using ADAMII can be easily employed in resource-limited areas to replace conventional flow cytometers, which are expensive and require highly trained staff.


Assuntos
Contagem de Linfócito CD4/instrumentação , Linfócitos T CD4-Positivos/citologia , Citometria de Fluxo/instrumentação , Fluorescência , Infecções por HIV/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Contagem de Linfócito CD4/economia , Países em Desenvolvimento , Humanos
3.
Clin Hemorheol Microcirc ; 56(1): 67-74, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23364023

RESUMO

Since Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.


Assuntos
Aglutinação/fisiologia , Eritrócitos/citologia , Microfluídica/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Microfluídica/métodos , Microscopia
4.
Clin Chem Lab Med ; 52(5): 715-23, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24323891

RESUMO

BACKGROUND: We evaluated the analytical performance of a new one-step rapid quantitative sandwich immunoassay for total prostate-specific antigen (tPSA), the FREND™ PSA Plus (FREND PSA) (NanoEnTek Inc., Seoul, Korea). METHODS: The imprecision, linearity, hook effect, detection limit (LoD), and interference were evaluated and trueness verification and matrix validation were performed. For method comparison, 79 patient specimens were analyzed with FREND PSA and two comparative tPSA assays (Architect® total PSA and cobas® total PSA assay). RESULTS: Total CVs of the imprecision for low (0.208 ng/mL), medium (4.051 ng/mL), and high PSA levels (5.469 ng/mL) were 15.9%, 6.4%, and 9.1%, respectively. Linearity was observed from 1.01 to 19.15 ng/mL and the hook phenomenon was absent up to 171.48 ng/mL. The LoD was 0.094 ng/mL. The regression equations between FREND (y) and Architect or cobas were as follows: y=0.0133+1.054x (r=0.973), y=-0.2144+1.066x (r=0.977), respectively. Differences between FREND PSA and the comparative methods at a medical decision level of 4.0 ng/mL were less than the optimum specification bias (9.3%). The percentage biases from the trueness verification and interference test were less than the desirable specifications for bias (18.7%). The plasma tPSA level measured with lithium heparin or K2EDTA was comparable to that in the serum. CONCLUSIONS: The FREND PSA provided reliable analytical performance and test results in comparison to two widely used tPSA assays. It is a simple and rapid test for tPSA and can be applied in point-of-care testing.


Assuntos
Imunoensaio , Antígeno Prostático Específico/sangue , Ácido Edético/química , Heparina/química , Humanos , Lítio/química , Masculino , Neoplasias da Próstata/diagnóstico , Kit de Reagentes para Diagnóstico
5.
Artigo em Inglês | MEDLINE | ID: mdl-24110525

RESUMO

Single cell gel electrophoresis, also known as comet assay, has been widely used for assessing the effect of genotoxicity and detecting DNA damage of individual eukaryotic cells. There exist established imaging techniques for cometassay analysis, but these platforms have limitations such as required user interventions, low throughput, and weakness to noise caused by incomplete dyeing of fluorescent materials and other experimental errors. To resolve these, we propose a novel procedure for analyzing comet assay images, which considers various DNA damage patterns and classifies them in a robust manner. We tested our approach with twenty golden data sets containing over 300 comets and achieved satisfactory classification accuracy.


Assuntos
Ensaio Cometa/métodos , Dano ao DNA , Processamento de Imagem Assistida por Computador/métodos , Apoptose , Humanos , Software
6.
J Clin Lab Anal ; 25(2): 90-4, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21437999

RESUMO

The cell viability test is an essential tool in any laboratory, performing cell-based studies and clinical laboratory tests. The trypan blue exclusion method is the most popular assay for its simple concept among various diagnostic tools. However, several disadvantages include time-consuming and labor-intensive steps with low precision. In this study, we evaluated a new technique for the automatic cell viability measurement with microscopic cell counter and microchip. Upon blood draw from 11 healthy volunteers, Mononuclear cells were separated immediately from the heparinized whole blood, and the viable cells were diluted from 100 to 1%. The cell viability tests were performed simultaneously with following three methods: the conventional manual trypan blue exclusion method; the flow cytometry measurement with propidium iodide stain; and the newly developed microscopic cell counter with microchip. Linearities, precisions, and correlations from three methods were analyzed and compared. The correlations data from the microscopic cell counter were in good agreement with both the conventional trypan blue method (r=0.99, P<0.05) and the flow cytometry (r=0.99, P<0.05), respectively. The precision (2.0-6.2%) and linearity from the microscopic cell counter method with microchip were superior in comparison with the conventional method. The microscopic cell counter with microchip performed well with high precision, linearity, and efficient running time than both the manual trypan blue and the flow cytometry methods.


Assuntos
Citometria de Fluxo/métodos , Dispositivos Lab-On-A-Chip , Permeabilidade da Membrana Celular , Sobrevivência Celular , Humanos , Contagem de Leucócitos/instrumentação , Contagem de Leucócitos/métodos , Leucócitos Mononucleares/citologia , Microscopia de Fluorescência , Reprodutibilidade dos Testes , Azul Tripano/análise , Azul Tripano/metabolismo
7.
Bioanalysis ; 2(10): 1755-65, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21083327

RESUMO

Image cytometry is a method for quantitative cellular analysis using images generally captured on slides or microfabricated chips. The flowless nature of data acquisition in image cytometry allows the use of value components, such as light-emitting diode excitation sources or low-cost charge-coupled device detectors. Unlike flow cytometry, the stationary cellular samples can be exposed to lower-intensity light and utilize less sensitive detectors with higher exposure times. Images are acquired and data is processed using recognition software to identify, count and analyze cells. Current image cytometers cannot replicate the quality of the data from flow cytometers or fluorescence microscopes with full functionality and performance components. Yet, the production of inexpensive image cytometers for use in small laboratories and clinics has made a compelling argument. The addition of fluorescence detection to the new generation of image cytometers has opened the field to a broader range of applications. This article will review the technical aspects and application of image cytometers, the recent progress in the field and available commercial devices.


Assuntos
Citometria por Imagem/métodos , Animais , Células/citologia , Humanos , Citometria por Imagem/instrumentação , Citometria de Varredura a Laser , Lentes , Luz , Técnicas Analíticas Microfluídicas
8.
Lab Chip ; 10(23): 3243-54, 2010 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-20941407

RESUMO

A portable flow cytometer has been recognized as an important tool for many clinical applications such as HIV/AIDS screening in developing countries and regions with limited medical facilities and resources. Conventional flow cytometers typically require multiple detectors for simultaneous identification of multiple subsets of immune cell. To minimize the number of detectors toward portable flow cytometry or to analyze multi-parametric cellular information with minimum number of detectors in conventional flow cytometers, we propose a versatile multiplexed cell-counting method using functional silica nanoparticles (SiNPs). FITC-doped SiNPs, which are 100 times brighter than the FITC molecules itself, were used as new intensity-based fluorescent dye complexes to simultaneously measure two subsets of leukocytes using a single detector. CD45(+)CD4(+) cells tagged with these FITC-doped SiNPs were 50 times brighter than CD45(+)CD4(-) cells tagged only with FITC. To make the overall system compact, a disposable microchip flow cytometer that does not require sheath flow was developed. Combining these dye-doped SiNPs based detection schemes and the sheathless microchip flow cytometer scheme, we successfully identified and counted two subsets of leukocytes simultaneously (R(2) = 0.876). These approaches can be the building blocks for a truly portable and disposable flow cytometer for various clinical cytometry applications.


Assuntos
Contagem de Células , Citometria de Fluxo/métodos , Corantes Fluorescentes/química , Dispositivos Lab-On-A-Chip , Leucócitos/citologia , Nanopartículas/química , Dióxido de Silício/química , Anticorpos Monoclonais/química , Linfócitos T CD4-Positivos/citologia , Diferenciação Celular , Humanos , Citometria por Imagem/métodos , Imunoglobulina G/química , Antígenos Comuns de Leucócito/biossíntese , Nanopartículas Metálicas/química
9.
Cytometry B Clin Cytom ; 76(5): 345-53, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19130482

RESUMO

We have designed and evaluated the performance of a simple, rapid, and affordable method for counting CD4(+) T-cells with the use of plastic microchips. This new system is an adaptation of a "no-lyse, no-wash," volumetric single platform assay, and absolute CD4(+) counts are determined with the use of a microscopic scanning cell counter. To assess the CD4(+) count test precision and linearity of the system, measured CD4(+) counts were compared with two other reference assays (single and dual platform flow cytometry) with the use of 123 clinical samples including samples obtained from 35 HIV-infected patients, and artificially diluted samples. A correlation between the results from the use of the new method and from the use of the two other reference assays was r = 0.98 for the clinical samples. A dilution test of the new method demonstrated a linearity of r >or= 0.99, with coefficients of variation

Assuntos
Linfócitos T CD4-Positivos/patologia , Citometria de Fluxo/instrumentação , Procedimentos Analíticos em Microchip , Contagem de Linfócito CD4 , Citometria de Fluxo/métodos , Infecções por HIV/sangue , Infecções por HIV/imunologia , Humanos , Reprodutibilidade dos Testes
10.
Biosens Bioelectron ; 23(9): 1353-60, 2008 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18242073

RESUMO

Electroporation is widely used to achieve gene transfection. A common problem in electroporation is that it has a lower viability than any other transfection method. In this study, we developed a novel electroporation device using a capillary tip and a pipette that was effective on a wide range of mammalian cells, including cell lines, primary cells, and stem cells. The capillary electroporation system considerably reduced cell death during electroporation because of its wire-type electrode, which has a small surface area. The experimental results also indicated that the cell viability was dependent on the change in pH induced by electrolysis during electroporation. Additionally, the use of a long and narrow capillary tube combined with simple pipetting shortened the overall time of the electroporation process by up to 15 min, even under different conditions with 24 samples. These results were supported by comparison with a conventional electroporation system. The transfection rate and the cell viability were enhanced by the use of the capillary system, which had a high transfection rate of more than 80% in general cell lines such as HeLa and COS-7, and more than 50% in hard-to-transfect cells such as stem or primary cells. The viability was approximately 70-80% in all cell types used in this study.


Assuntos
Eletrodos , Eletroporação/métodos , Animais , Linhagem Celular , Sobrevivência Celular , Eletroporação/instrumentação , Humanos , Concentração de Íons de Hidrogênio , Metais/química , Transfecção
12.
Biosens Bioelectron ; 22(12): 3273-7, 2007 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-17395450

RESUMO

We developed a multi-channel electroporation microchip made of polydimethylsiloxane (PDMS) and glass for gene transfer in mammalian cells. This chip produces multiple electric field gradients in a single microchip by varying the lengths of the microchannels from 2 to 4 cm. Electric fields of 0.65, 0.57, 0.49, 0.41, and 0.33 kV/cm were simultaneously produced in a single chip when the voltage of 1.3 kV was applied. We transferred enhanced green fluorescent protein genes (pEGFP) into HEK-293 and CHO cells, which were cultured within the microchannels. The feasibility of our device was demonstrated because it was able to produce five different transfection rates and survival rates at different electric fields produced in a single microchip. This system is expected to optimize the experimental conditions in gene transfection research more easily and faster than conventional electroporation methods.


Assuntos
Eletroporação/instrumentação , Dispositivos Lab-On-A-Chip , Transfecção/instrumentação , Animais , Células CHO , Cricetinae , Cricetulus , Proteínas de Fluorescência Verde/genética , Humanos , Plasmídeos
13.
Lab Chip ; 7(4): 516-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17389970

RESUMO

This paper presents a novel method for an on-chip erythrocyte deformability test under optical pressure, especially to enhance the level of sensitivity with respect to the detection of cancerous diseases. To demonstrate the performance and sensitivity of the combined method, we introduce the concept of transit velocity, a modified elongation index, and shape recovery time of individual erythrocytes in a strictly confined region (2 microm deep, 4 microm wide, and 100 microm long). Finally, we investigate a synergy or convergence effect due to the combination of these parameters for in situ detection of cancerous diseases under optical pressure.


Assuntos
Deformação Eritrocítica , Eritrócitos/citologia , Adulto , Elasticidade , Agregação Eritrocítica , Humanos , Neoplasias/sangue , Neoplasias/diagnóstico , Óptica e Fotônica , Pressão , Sensibilidade e Especificidade , Fatores de Tempo
14.
Lab Chip ; 6(10): 1381-3, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17102853

RESUMO

This paper presents a novel way of designing a flow focusing channel for microchip flow cytometers. With this method we increased throughput and sensitivity of particle detection at the same time. Generally, to increase the detection throughput of a flow cytometer, the speed of the flow inside the focusing channel needs to be increased, hence reducing the time of exposure to laser beam. With the shorter exposure time, both the fluorescence and scatter signal from the target particles become dimmer. To increase the sensitivity of signal detection, however, the speed of the flow should be decreased so as to decrease throughput of detection. To overcome this dilemmatic problem, we integrated an expansion channel inside a focusing channel. Signals from particles in an expansion channel were about 10 times brighter than those in a normal channel. With this enhanced sensitivity, we could also speed up the inlet flow, which in turn increases the overall throughput of detection.


Assuntos
Citometria de Fluxo , Técnicas Analíticas Microfluídicas , Microesferas , Sensibilidade e Especificidade
15.
Biotechnol Lett ; 27(6): 443-8, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15834811

RESUMO

Expression of hsp 27 in human umbilical vein endothelial cells exposed to a shear stress was investigated. Using immunostaining, it was concluded that shear stress results in perinuclear translocation of hsp 27. Polymerization of actin microfilaments plays an important role in this process.


Assuntos
Núcleo Celular/metabolismo , Endotélio Vascular/metabolismo , Proteínas de Choque Térmico HSP70/metabolismo , Estresse Mecânico , Citoesqueleto de Actina/metabolismo , Actinas/metabolismo , Células Cultivadas , Células Endoteliais/metabolismo , Endotélio Vascular/citologia , Humanos , Transporte Proteico , Veias Umbilicais/citologia
16.
Anal Chem ; 76(23): 7045-52, 2004 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-15571358

RESUMO

Transfection of DNA molecules into mammalian cells with electric pulsations, which is so-called electroporation, is a powerful and widely used method that can be directly applied to gene therapy. However, very little is known about the basic mechanisms of DNA transfer and cell response to the electric pulse. We developed a microelectroporation chip with poly(dimethylsiloxane) (PDMS) to investigate the mechanism of electroporation as a first step of DNA transfer and to introduce the benefits of miniaturization into the genetic manipulation. The microelectroporation chip has a microchannel with a height of 20 microm and a length of 2 cm. Owing to the transparency of PDMS, we could in situ observe the uptake process of propidium iodide (PI) into SK-OV-3 cells, which shows promise in visualization of gene delivery in living cells. We also noticed the geometric effect on the degree of electroporation in microchannels with diverse channel width. This experimental result shows that the geometry can be another parameter to be considered for the electroporation when it is performed in microchannels with an exponential decaying pulse generator. Cell culturing is possible within the microelectroporation chip, and we also successfully transfected SK-OV-3 cells with enhanced green fluorescent protein genes, which demonstrates the feasibility of the microelectroporation chip in genetic manipulation.


Assuntos
Eletroporação/métodos , Técnicas Analíticas Microfluídicas/métodos , Transfecção/métodos , Animais , Linhagem Celular Tumoral , Permeabilidade da Membrana Celular/fisiologia , Dimetilpolisiloxanos , Eletroporação/instrumentação , Desenho de Equipamento , Regulação da Expressão Gênica , Proteínas de Fluorescência Verde/química , Proteínas de Fluorescência Verde/genética , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Cifozoários/química , Sensibilidade e Especificidade , Silicones , Propriedades de Superfície , Fatores de Tempo , Células Tumorais Cultivadas
17.
J Chromatogr A ; 1013(1-2): 111-22, 2003 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-14604113

RESUMO

Several anomalies, e.g., in peak shape, migration time, and baseline drift, all due to pressure-driven backflow, were previously reported to occur during serial injection on capillary electrophoresis (CE) chips. Since these anomalies were worse for polydimethylsiloxane (PDMS) microchips than for glass microchips, reproducible data on PDMS microchips were difficult to obtain. In this paper, we found that these problems were affected by the hydrophilic or hydrophobic properties of the reservoirs on the microchip and demonstrated that these anomalies were reduced by converting the hydrophobic properties of the reservoirs on the PDMS microchip into hydrophilic ones. Thus, compared with hydrophobic reservoirs, hydrophilic reservoirs were suitable for the formation of a stable plug. Several chip designs were suggested to reduce these pressure-driven backflows.


Assuntos
Eletroforese Capilar/métodos , Miniaturização , Dimetilpolisiloxanos/química , Silicones/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...