Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1091: 30-39, 2019 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-31679572

RESUMO

A screw-based portable and simple solid phase microextraction device was fabricated by a 3D printer and used in combination with the developed silver-incorporated porous polyaniline film pencil lead solid-phase microextraction fiber (Ag/PANI SPME). Scanning electron microscopy revealed a porous structure of the electrodeposited Ag/PANI film. The spectrum from energy dispersive x-ray spectroscopy (EDS) and the elemental map confirmed the presence of silver in the porous polymer film. It was used under stirring for the extraction of five phthalate esters: dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), benzyl butyl phthalate (BBP) and di-2-ethylhexyl phthalate (DEHP). The extracted solution was identified and quantified by gas chromatography using a flame ionization detector (GC-FID). Under the optimum conditions of the developed method, a good linearity was obtained in a concentration range of 5.0-1000 µg L-1 for all five phthalate esters with limits of detection (LODs) of 4.41 ±â€¯0.91 µg L-1, 3.98 ±â€¯0.92 µg L-1, 3.65 ±â€¯0.74 µg L-1, 4.91 ±â€¯0.52 µg L-1 and 4.25 ±â€¯0.66 µg L-1 for DMP, DEP, DBP, BBP and DEHP, respectively. The developed method provided good precision when tested with standard solutions (RSD < 5.5%, n = 6) and real samples (RSD < 3.4%, n = 6). Good fiber-to-fiber reproducibility was also confirmed by extraction with six newly prepared fibers; recoveries ranged from 81.09 ±â€¯0.54% to 92.92 ±â€¯0.46% with RSD <6.6%. The developed method was used to determine phthalate esters in 14 cosmeceutical samples. In rubbing alcohol samples, DEP and DEHP were detected at 7.03 ±â€¯0.76 µg L-1 and 5.89 ±â€¯0.53 µg L-1, respectively, while in contact lens cleaners, DEHP was found in a concentration range from 5.3 ±â€¯1.1 µg L-1 to 6.8 ±â€¯1.2 µg L-1. No phthalate esters contamination was detectable in saline solutions, eye cleaners and antibacterial disinfectant liquids. Recoveries in the range of 81.92 ±â€¯0.99% to 102.4 ±â€¯1.1% indicated the good accuracy of the developed method.


Assuntos
Compostos de Anilina/química , Cosmecêuticos/análise , Ésteres/análise , Grafite/química , Ácidos Ftálicos/análise , Prata/química , 2-Propanol/análise , Adsorção , Cromatografia Gasosa , Soluções para Lentes de Contato/análise , Desinfetantes/análise , Desenho de Equipamento , Limite de Detecção , Impressão Tridimensional , Solução Salina/análise , Microextração em Fase Sólida/instrumentação , Microextração em Fase Sólida/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...