Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Semin Pediatr Surg ; 33(4): 151441, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38986242

RESUMO

Surgical repair of the diaphragm is essential for survival in congenital diaphragmatic hernia (CDH). There are many considerations surrounding the operation - why the operation matters, optimal timing of repair and its relation to extracorporeal life support (ECLS) use, minimally invasive versus open approaches, and strategies for reconstruction. Surgery is both affected by, and affects, the physiology of these infants and is an important factor in determining long-term outcomes. Here we discuss the evidence and provide insight surrounding this complex decision making, technical pearls, and outcomes in repair of CDH.

2.
J Pediatr Surg ; 59(8): 1515-1525, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38350773

RESUMO

BACKGROUND: Pulmonary hypertension remains difficult to manage in congenital diaphragmatic hernia (CDH). Prenatal therapy may ameliorate postnatal pulmonary hypertension. We hypothesized that intra-amniotic (IA) injection of either sildenafil, a phosphodiesterase 5 inhibitor, or rosiglitazone, a PPAR-γ agonist, or both late in gestation would decrease the detrimental pulmonary vascular remodeling seen in CDH and improve peripheral pulmonary blood flow. METHODS: Pregnant rats were gavaged with nitrogen on embryonic day (E) 9.5 to induce fetal CDH. Sildenafil and/or rosiglitazone were administered to each fetus via an intra-amniotic injection after laparotomy on the pregnant dam at E19.5, and fetuses delivered at E21.5. Efficacy measures were gross necropsy, histology, peripheral blood flow assessment using intra-cardiac injection of a vascular tracer after delivery, and protein expression analysis. RESULTS: Intra-amniotic injections did not affect fetal survival, the incidence of CDH, or lung weight-to-body weight ratio in CDH fetuses. IA sildenafil injection decreased pulmonary vascular muscularization, and rosiglitazone produced an increase in peripheral pulmonary blood flow distribution. The combination of sildenafil and rosiglitazone decreased pulmonary artery smooth muscle cell proliferation. These intra-amniotic treatments did not show any negative effects in either CDH fetuses or control fetuses. CONCLUSION: IA injection of sildenafil and rosiglitazone late in gestation ameliorates the pulmonary hypertensive phenotype of CDH and may have utility in clinical translation. LEVEL OF EVIDENCE: Not applicable.


Assuntos
Hérnias Diafragmáticas Congênitas , Hipertensão Pulmonar , Ratos Sprague-Dawley , Rosiglitazona , Citrato de Sildenafila , Citrato de Sildenafila/administração & dosagem , Citrato de Sildenafila/uso terapêutico , Citrato de Sildenafila/farmacologia , Animais , Rosiglitazona/administração & dosagem , Rosiglitazona/farmacologia , Rosiglitazona/uso terapêutico , Hérnias Diafragmáticas Congênitas/complicações , Feminino , Gravidez , Ratos , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/etiologia , Modelos Animais de Doenças , Fenótipo , Inibidores da Fosfodiesterase 5/administração & dosagem , Inibidores da Fosfodiesterase 5/uso terapêutico , Inibidores da Fosfodiesterase 5/farmacologia , Remodelação Vascular/efeitos dos fármacos , Terapias Fetais/métodos , Tiazolidinedionas/administração & dosagem , Tiazolidinedionas/uso terapêutico , Circulação Pulmonar/efeitos dos fármacos
3.
J Pediatr Surg ; 59(3): 451-458, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37865575

RESUMO

BACKGROUND: Infants with congenital diaphragmatic hernia (CDH) experience high morbidity and mortality due to pulmonary arterial hypertension and hypoplasia. Mechanical ventilation is a central component of CDH management. Our objective was to evaluate the impact of a standardized clinical practice guideline (implemented in January 2012) on ventilator management for infants with CDH, and associate management changes with short-term outcomes, specifically extracorporeal membrane oxygenation (ECMO) utilization and survival to discharge. METHODS: We conducted a retrospective pre-post study of 103 CDH infants admitted from January 2007-July 2021, divided pre- (n = 40) and post-guideline (n = 63). Clinical outcomes, ventilator settings, and blood gas values in the first 7 days of mechanical ventilation were compared between the pre- and post-guideline cohorts. RESULTS: Post-guideline, ECMO utilization decreased (11% vs 38%, p = 0.001) and survival to discharge improved (92% vs 68%, p = 0.001). More post-guideline patients remained on conventional mechanical ventilation without need for escalation to high-frequency ventilation or ECMO, and had higher pressures and PaCO2 with lower FiO2 and PaO2 (p < 0.05). CONCLUSIONS: Standardized ventilator management optimizing pressures for adequate lung expansion and minimizing oxygen toxicity improves outcomes for infants with CDH. LEVEL OF EVIDENCE: III.


Assuntos
Hérnias Diafragmáticas Congênitas , Humanos , Hérnias Diafragmáticas Congênitas/terapia , Estudos Retrospectivos , Pulmão/anormalidades , Respiração Artificial , Ventiladores Mecânicos
5.
Pediatr Res ; 89(3): 622-627, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32357365

RESUMO

BACKGROUND: Bubble continuous positive airway pressure is an established therapy for infants in respiratory distress. In resource-limited settings, few treatment options exist for infants requiring further respiratory support. A bubble bilevel device has been developed to provide nonelectric, time-cycled, pressure-limited respiratory support. We compared the efficacy of bubble bilevel ventilation with conventional mechanical ventilation in sedated rabbits. METHODS: Six adult rabbits under inhaled isoflurane general anesthesia were ventilated by alternating intervals of conventional and bubble bilevel ventilation for three 10-15-min periods. During each period, interval arterial blood gas (ABG) measurements were obtained after at least 10 min on the respective mode of ventilation. RESULTS: The bubble bilevel system was able to deliver the following pressures: 20/7, 15/5, 12/5, 8/5 cm H2O. The estimated differences in arterial blood gas values on bubble bilevel vs. ventilator were as follows (normalized values): pH 7.41 vs. 7.40, pCO2 37.7 vs. 40, pO2 97.6 vs. 80. In addition, the bubble bilevel ventilation delivered consistent pressure waveforms without interruption for over 60 min on two rabbits. CONCLUSION: This study demonstrates promising in vivo results on the efficacy of a novel bubble bilevel device, which may prove useful for infants in respiratory distress. IMPACT: Given the lack of personnel, funds or infrastructure to provide neonatal mechanical ventilation in resource-limited settings, additional low-cost, low-tech treatments are necessary to save infant lives. Bubble bilevel ventilation reliably delivers two levels of airway pressure to anesthetized rabbits resulting in normalization of blood gases comparable to those achieved on a traditional ventilator. If proven effective, simple technologies like this device have the potential to significantly impact neonatal mortality due to respiratory distress globally.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Gases , Respiração Artificial/métodos , Anestesia , Animais , Gasometria , Desenho de Equipamento , Coelhos , Respiração
6.
J Surg Res ; 256: 433-438, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32795706

RESUMO

BACKGROUND: Severe congenital chylothorax (SCC) may result in respiratory failure, malnutrition, immunodeficiency, and sepsis. Although typically managed with bowel rest, parenteral nutrition, and octreotide, persistent chylothoraces require surgical management. At our institution, a pleurectomy, unilateral or bilateral, in combination with mechanical pleurodesis and thoracic duct ligation is performed for SCC, and we describe our approach and outcomes. MATERIALS AND METHODS: We reviewed over 15-year period neonatal patients with SCC managed surgically with pleurectomy after medical therapy was unsuccessful. Patients were divided into two groups: those who underwent pleurectomy within 28 d of diagnosis (early group) and those who underwent pleurectomy after 28 d (late group). Resolution of chylothorax was defined by the absence of clinical symptoms as well as absent or minimal pleural effusion on chest X-ray. RESULTS: Of 40 patients diagnosed with SCC over the study period, 15 underwent pleurectomy, eight early [mean time to operation = 20 (IQR 17, 23) d] and 7 late [59 (42, 75) d, P = 0.001]. Overall survival was 67% (10 of 15). Seven of 8 (88%) neonates who underwent early pleurectomy survived versus 3 of 7 (43%) who underwent late pleurectomy (P = 0.07). Length of stay was lower in the early group than the late group [73 (57, 79) versus 102 (109, 213) d, P = 0.05]. All patients who survived to discharge had resolution of their chylothorax. CONCLUSIONS: Pleurectomy with mechanical pleurodesis and thoracic duct ligation is effective in the management of severe congenital chylothorax. When performed earlier, pleurectomy for severe congenital chylothorax may be associated with improved survival and shorter hospital length of stay.


Assuntos
Quilotórax/congênito , Pleura/cirurgia , Pleurodese/métodos , Ducto Torácico/cirurgia , Tempo para o Tratamento , Tubos Torácicos , Quilotórax/diagnóstico , Quilotórax/mortalidade , Quilotórax/cirurgia , Terapia Combinada/instrumentação , Terapia Combinada/métodos , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Tempo de Internação/estatística & dados numéricos , Ligadura , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
8.
ASAIO J ; 66(7): 753-759, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31453833

RESUMO

Preservation of a donor heart for transplantation is limited to 6-8 hours. Based on our demonstration of 12 hour perfusion with plasma cross circulation, this study aimed to evaluate ex vivo heart perfusion (EVHP) for up to 72 hours using cross plasma circulation (XC-plasma) from a live, awake paracorporeal sheep (PCS). Six ovine hearts were perfused for 72 hours using plasma cross circulation at a rate of 1 L/min with a live, awake PCS. Controls were seven perfused hearts without cross circulation. Experiments were electively ended at 72 hours, and epinephrine (0.1 mg) was delivered to demonstrate hormonal responsiveness. All controls failed at 6-10 hours. All six hearts perfused for 72 hours maintained normal heart function, metabolism, and responsiveness to epinephrine. Blood gases, electrolytes, and lactate levels were normal and stable throughout the study. All hearts appeared suitable for transplantation. We have demonstrated successful normothermic EVHP for 72 hours.


Assuntos
Circulação Cruzada/métodos , Transplante de Coração , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Circulação Extracorpórea/métodos , Ovinos
9.
J Pediatr Surg ; 54(6): 1147-1152, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30902457

RESUMO

INTRODUCTION: The purpose of this study is to evaluate splenic effects during artificial placenta (AP) support. METHODS: AP lambs (118-121 d, n = 14) were delivered and placed on the AP support for a goal of 10-14 days. Cannulation used right jugular drainage and umbilical vein reinfusion. Early (ETC; 115-120 d; n = 7) and late (LTC; 125-131 d; n = 7) tissue controls were delivered and immediately sacrificed. Spleens were formalin fixed, H&E stained, and graded for injury, response to inflammation, and extramedullary hematopoiesis (EMH). CD68 and CD163 stains were used to assess for macrophage activation and density. Clinical variables were correlated with splenic scores. Groups were compared using Fisher's Exact Test and descriptive statistics. p < 0.05 indicated significance. RESULTS: Mean survival for AP lambs was 12 ±â€¯5 d. There was no necrosis found in any of the groups. Vascular congestion and sinusoidal histiocytosis did not significantly differ between AP and control groups (p = 0.72; p = 0.311). There were significantly more pigmented macrophages (p = 0.008), CD163 (p = <0.001), and CD68 (p = <0.001) stained cells in the AP group. ETC and LTC demonstrated more EMH than AP spleens (p = <0.001). CONCLUSIONS: During AP support, spleens appear to develop normally and exhibit an appropriate inflammatory response. After initiation of AP support, EMH transitions away from the spleen. STUDY TYPE: Research Paper/Therapeutic Potential. LEVEL OF EVIDENCE: N/A.


Assuntos
Órgãos Artificiais , Placenta/fisiologia , Nascimento Prematuro , Carneiro Doméstico/crescimento & desenvolvimento , Baço , Animais , Feminino , Gravidez , Nascimento Prematuro/mortalidade , Nascimento Prematuro/veterinária , Ovinos , Baço/crescimento & desenvolvimento , Baço/imunologia , Baço/fisiologia
11.
Am J Perinatol ; 36(7): 742-750, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30372770

RESUMO

PURPOSE: We hypothesized that surgical energy could be used to create hysterotomies in open fetal surgery. STUDY DESIGN: Initial studies compared the LigaSure Impact and Harmonic ACE + 7 Shears in the efficiency of hysterotomy and thermal damage. Pregnant ewes at an estimated gestational age (EGA) of 116 to 120 days (term = 145; n = 7) underwent hysterotomy using either device. Hysterotomy edges were resected, and thermal injury extent was determined by histopathological assessment. Upon determining a superior device, subsequent studies compared this to the AutoSuture Premium Poly CS*-57 Stapler in uterine healing. Pregnant ewes (n = 6) at an EGA of 87 to 93 days underwent 6-cm hysterotomy in each gravid horn with either the stapler (n = 5) or Harmonic (n = 5) followed by closure and animal recovery. After 37 to 42 days, uterine healing was assessed by evaluating tensile strength and histopathology. RESULTS: Thermal damage was more extensive with the LigaSure (n = 11 hysterotomies) than with the Harmonic (n = 11; 5.6 ± 1 vs. 3.1 ± 0.6 mm; p < 0.0001);therefore, the Harmonic was selected for healing studies. Gross scar appearance and tensile strength were the same between the Harmonic and stapler. The stapler caused more fibrosis (4/7 samples with "moderate" fibrosis vs. 0/8 with the Harmonic; p = 0.02). CONCLUSION: The Harmonic ACE + 7 caused less thermal injury than the LigaSure Impact and performed similar to the CS*-57 Stapler in uterine healing with continued gestation.


Assuntos
Eletrocirurgia/instrumentação , Terapias Fetais/métodos , Feto/cirurgia , Histerotomia/métodos , Grampeamento Cirúrgico , Animais , Cicatriz/etiologia , Desenho de Equipamento , Feminino , Histerotomia/efeitos adversos , Histerotomia/instrumentação , Modelos Animais , Ovinos , Útero/patologia
12.
ASAIO J ; 65(7): 690-697, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30585874

RESUMO

An artificial placenta (AP) utilizing extracorporeal life support (ECLS) could protect premature lungs from injury and promote continued development. Preterm lambs at estimated gestational age (EGA) 114-128 days (term = 145) were delivered by Caesarian section and managed in one of three groups: AP, mechanical ventilation (MV), or tissue control (TC). Artificial placenta lambs (114 days EGA, n = 3; 121 days, n = 5) underwent venovenous (VV)-ECLS with jugular drainage and umbilical vein reinfusion for 7 days, with a fluid-filled, occluded airway. Mechanical ventilation lambs (121 days, n = 5; 128 days, n = 5) underwent conventional MV until failure or maximum 48 hours. Tissue control lambs (114 days, n = 3; 121 days, n = 5; 128 days, n = 5) were sacrificed at delivery. At the conclusion of each experiment, lungs were procured and sectioned. Hematoxylin and eosin (H&E) slides were scored 0-4 in seven injury categories, which were summed for a total injury score. Slides were also immunostained for platelet-derived growth factor receptor (PDGFR)-α and α-actin; lung development was quantified by the area fraction of double-positive tips of secondary alveolar septa. Support duration of AP lambs was 163 ± 9 (mean ± SD) hours, 4 ± 3 for early MV lambs, and 40 ± 6 for late MV lambs. Total injury scores at 121 days were 1.7 ± 2.1 for AP vs. 5.5 ± 1.6 for MV (p = 0.02). Using immunofluorescence, double-positive tip area fraction at 121 days was 0.017 ± 0.011 in AP lungs compared with 0.003 ± 0.003 in MV lungs (p < 0.001) and 0.009 ± 0.005 in TC lungs. At 128 days, double-positive tip area fraction was 0.012 ± 0.007 in AP lungs compared with 0.004 ± 0.004 in MV lungs (p < 0.001) and 0.016 ± 0.009 in TC lungs. The AP is protective against lung injury and promotes lung development compared with mechanical ventilation in premature lambs.


Assuntos
Órgãos Artificiais , Lesão Pulmonar/prevenção & controle , Pulmão/crescimento & desenvolvimento , Placenta/fisiologia , Nascimento Prematuro/fisiopatologia , Animais , Animais Recém-Nascidos , Oxigenação por Membrana Extracorpórea , Feminino , Gravidez , Respiração Artificial , Ovinos
13.
J Surg Res ; 231: 361-365, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30278954

RESUMO

BACKGROUND: Congenital chylothorax (CC) can have devastating consequences for neonates. We sought to determine the outcomes of cases treated at our institution and evaluate the role of fetal intervention. MATERIALS AND METHODS: With Institutional Review Board approval, patients treated at our institution 09/2006-04/2016 with CC were reviewed. History and outcomes were compared between patients undergoing fetal intervention (fetal group) and patients who did not (control group). RESULTS: Twenty-three patients were identified. Mean gestational age at birth was 35 wk. Overall mortality was 30% (7 patients). Nineteen patients (83%) were prenatally diagnosed, and 10 patients (43%) underwent fetal intervention. Birth weight was significantly lower in the fetal group compared to the control group (median interquartile range [IQR]; 2.5 [2.3-3.0] versus 3.3 [2.6-3.7] kg, P = 0.02). Apgar scores were significantly higher in the fetal group than the control group at 1 and 5 min (median [IQR]; 6 [4-8] versus 1 [1-2], P = 0.005 and 8 [7-9] versus 2 [2-6], P = 0.008, respectively). For those patients with prenatal diagnosis of CC and hydrops fetalis, thrombosis and lymphopenia were both improved in the fetal group (thrombosis 0% versus 40%, P = 0.03; lymphocyte nadir [median {IQR}] 1.5 [0.6-2.9] versus 0.1 [0.05-0.2], P = 0.02). Duration of support with mechanical ventilation was significantly shorter in the fetal group (median [IQR]; 1 [0-40] versus 41 [29-75] d, P = 0.04). CONCLUSIONS: Fetal intervention for CC is associated with improved Apgar scores and decreased ventilator days and complications in patients with hydrops fetalis. Fetuses with chylothorax, especially those with hydrops, should be referred to a fetal center for evaluation.


Assuntos
Quilotórax/congênito , Terapias Fetais , Índice de Apgar , Quilotórax/complicações , Quilotórax/diagnóstico , Quilotórax/mortalidade , Quilotórax/terapia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Gravidez , Diagnóstico Pré-Natal , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
14.
J Pediatr Surg ; 53(10): 1896-1903, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29960740

RESUMO

PURPOSE: An artificial placenta (AP) utilizing extracorporeal life support (ECLS) could avoid the harm of mechanical ventilation (MV) while allowing the lungs to develop. METHODS: AP lambs (n = 5) were delivered at 118 days gestational age (GA; term = 145 days) and placed on venovenous ECLS (VV-ECLS) with jugular drainage and umbilical vein reinfusion. Lungs remained fluid-filled. After 10 days, lambs were ventilated. MV control lambs were delivered at 118 ("early MV"; n = 5) or 128 days ("late MV"; n = 5), and ventilated. Compliance and oxygenation index (OI) were calculated. After sacrifice, lungs were procured and H&E-stained slides scored for lung injury. Slides were also immunostained for PDGFR-α and α-actin; alveolar development was quantified by the area fraction of alveolar septal tips staining double-positive for both markers. RESULTS: Compliance of AP lambs was 2.79 ±â€¯0.81 Cdyn compared to 0.83 ±â€¯0.19 and 3.04 ±â€¯0.99 for early and late MV, respectively. OI in AP lambs was lower than early MV lambs (6.20 ±â€¯2.10 vs. 36.8 ±â€¯16.8) and lung injury lower as well (1.8 ±â€¯1.6 vs. 6.0 ±â€¯1.2). Double-positive area fractions were higher in AP lambs (0.012 ±â€¯0.003) than early (0.003 ±â€¯0.0005) and late (0.004 ±â€¯0.002) MV controls. CONCLUSIONS: Lung development continues and lungs are protected from injury during AP support relative to mechanical ventilation. LEVEL OF EVIDENCE: n/a (basic/translational science).


Assuntos
Órgãos Artificiais , Oxigenação por Membrana Extracorpórea , Pulmão/crescimento & desenvolvimento , Nascimento Prematuro/terapia , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Feminino , Idade Gestacional , Pulmão/fisiologia , Placenta/fisiologia , Gravidez , Ovinos
15.
J Pediatr Surg ; 53(6): 1234-1239, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29605267

RESUMO

PURPOSE: We evaluated whether brain development continues and brain injury is prevented during Artificial Placenta (AP) support utilizing extracorporeal life support (ECLS). METHODS: Lambs at EGA 118days (term=145; n=4) were placed on AP support (venovenous ECLS with jugular drainage and umbilical vein reinfusion) for 7days and sacrificed. Early (EGA 118; n=4) and late (EGA 127; n=4) mechanical ventilation (MV) lambs underwent conventional MV for up to 48h and were sacrificed, and early (n=5) and late (n=5) tissue control (TC) lambs were sacrificed at delivery. Brains were harvested, formalin-fixed, rehydrated, and studied by magnetic resonance imaging (MRI). The gyrification index (GI), a measure of cerebral folding complexity, was calculated for each brain. Diffusion-weighted imaging was used to determine fractional anisotropy (FA) and apparent diffusion coefficient (ADC) in multiple structures to assess white matter (WM) integrity. RESULTS: No intracranial hemorrhage was observed. GI was similar between AP and TC groups. ADC and FA did not differ between AP and late TC groups in any structure. Compared to late MV brains, AP brains demonstrated significantly higher ADC (0.45±0.08 vs. 0.27±0.11, p=0.02) and FA (0.61±0.04 vs. 0.44±0.05; p=0.006) in the cerebral peduncles. CONCLUSIONS: After 7days of AP support, WM integrity is preserved relative to mechanical ventilation. TYPE OF STUDY: Research study.


Assuntos
Órgãos Artificiais , Lesões Encefálicas/prevenção & controle , Encéfalo/crescimento & desenvolvimento , Oxigenação por Membrana Extracorpórea/métodos , Recém-Nascido Prematuro/fisiologia , Placenta , Animais , Anisotropia , Encéfalo/diagnóstico por imagem , Lesões Encefálicas/diagnóstico por imagem , Modelos Animais de Doenças , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , Respiração Artificial , Ovinos
16.
J Pediatr Surg ; 53(6): 1240-1245, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29605266

RESUMO

BACKGROUND: An Artificial Placenta (AP) utilizing extracorporeal life support (ECLS) could revolutionize care of extremely premature newborns, but its effects on gastrointestinal morphology and injury need investigation. METHODS: Lambs (116-121days GA, term=145; n=5) were delivered by C-section, cannulated for ECLS, had total parenteral nutrition (TPN) provided, and were supported for 7days before euthanasia. Early and Late Tissue Controls (ETC, n=5 and LTC, n=5) delivered at 115-121days and 125-131days, respectively, were immediately sacrificed. Standardized jejunal samples were formalin-fixed for histology. Crypt depth (CD), villus height (VH), and VH:CD ratios were measured. Measurements also included enterocyte proliferation (Ki-67), Paneth cell count (Lysozyme), and injury scores (H&E). ANOVA and Chi Square were used with p<0.05 considered significant. RESULTS: CD, VH, and VH:CD were similar between groups (p>0.05). AP demonstrated more enterocyte proliferation (95.7±21.8) than ETC (49.4±23.4; p=0.003) and LTC (66.1+11.8; p=0.04), and more Paneth cells (81.7±17.5) than ETC (41.6±7.0; p=0.0005) and LTC (40.7±8.2, p=0.0004). Presence of epithelial injury and congestion in the bowel of all groups were not statistically different. No villus atrophy or inflammation was present in any group. CONCLUSIONS: This suggests preserved small bowel mucosal architecture, high cellular turnover, and minimal evidence of injury. STUDY TYPE: Research paper/therapeutic potential. LEVEL OF EVIDENCE: N/A.


Assuntos
Órgãos Artificiais , Oxigenação por Membrana Extracorpórea/métodos , Mucosa Gástrica/crescimento & desenvolvimento , Mucosa Intestinal/crescimento & desenvolvimento , Placenta , Animais , Contagem de Células , Proliferação de Células , Enterócitos/citologia , Feminino , Mucosa Gástrica/patologia , Humanos , Mucosa Intestinal/patologia , Jejuno/crescimento & desenvolvimento , Jejuno/patologia , Celulas de Paneth/citologia , Nutrição Parenteral Total , Gravidez , Nascimento Prematuro , Ovinos
17.
J Pediatr Surg ; 53(6): 1087-1091, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29580786

RESUMO

PURPOSE: Survivors of congenital diaphragmatic hernia (CDH) face high morbidity. We studied the neurodevelopmental outcomes of CDH survivors at a single institution. METHODS: CDH survivors born July 2006-March 2016 at a free-standing children's hospital were reviewed. Neurodevelopment was assessed using the Peabody Developmental Motor Scales (PDMS-2) broken into gross, fine, and total motor quotients. Data collected included prenatal variables (liver herniation, defect laterality, observed:expected total fetal lung volume (o:eTFLV) on MRI), birth demographics (sex, race, estimated gestational age (EGA), birth weight (BtWt), 5 min APGAR, associated anomalies), and therapies/hospital course (HFOV/HFJV, ECMO, timing of repair, pulmonary hypertension (PHTN) severity, length of stay, ventilator days). Variables were analyzed using mixed linear modeling. RESULTS: Sixty-eight children were included. Most patients had left-sided CDH (55/68, 81%) without liver herniation (42/68, 62%). ECMO utilization was 25/68 (37%). The mean [95% confidence interval] gross motor quotient for the entire cohort was 87 [84-91], fine motor quotient was 92 [88-96], and total motor quotient was 88 [84-93], representing below average, average, and below average functioning, respectively. o:eTFLV predicted fine motor quotient among prenatal variables. Associated anomalies and ECMO use predicted all quotients in the final model. CONCLUSIONS: Associated anomalies and ECMO use predict neurodevelopmental delay in CDH survivors. TYPE OF STUDY: Retrospective observational study; Prognostic. LEVEL OF EVIDENCE: II.


Assuntos
Hérnias Diafragmáticas Congênitas/complicações , Transtornos do Neurodesenvolvimento/etiologia , Criança , Pré-Escolar , Terapia Combinada , Oxigenação por Membrana Extracorpórea , Feminino , Seguimentos , Hérnias Diafragmáticas Congênitas/diagnóstico , Hérnias Diafragmáticas Congênitas/terapia , Herniorrafia , Humanos , Lactente , Recém-Nascido , Masculino , Transtornos do Neurodesenvolvimento/diagnóstico , Transtornos do Neurodesenvolvimento/epidemiologia , Prognóstico , Estudos Retrospectivos
18.
Neonatology ; 113(4): 313-321, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29478055

RESUMO

BACKGROUND: Extremely premature neonates suffer high morbidity and mortality. An artificial placenta (AP) using extracorporeal life support (ECLS) is a promising therapy. OBJECTIVES: We hypothesized that intratracheal perfluorocarbon (PFC) instillation during AP support would reduce lung injury and promote lung development relative to intratracheal amniotic fluid or crystalloid. METHODS: Lambs at an estimated gestational age (EGA) 116-121 days (term 145 days) were placed on venovenous ECLS with jugular drainage and umbilical vein reinfusion and intubated. Airways were managed by the instillation of amniotic fluid and tracheal occlusion (TO; n = 4), or lactated Ringer's (LR; n = 4) or perfluorodecalin (a PFC) without occlusion (n = 4). After 7 days, the animals were sacrificed. Early (EGA 116-121 days) and late (EGA 125-131 days) tissue control lambs were delivered and sacrificed. Lungs were formalin-inflated to 30 cm H2O and sectioned for histology. Injury was scored by an unbiased pathologist. Slides were immunostained for PDGFR-α and α-actin; development was quantified by the area fraction of double-positive tips. Surfactant protein-C (SP-C) concentration in bronchoalveolar lavage fluid was quantified using ELISA. RESULTS: Total injury scores were lower in PFC lungs (1.8 ± 1.7) than in TO (6.5 ± 2.1; p = 0.01) and LR lungs (5.5 ± 2.4; p = 0.01). The area fraction of double-positive alveolar tips appeared higher in PFC lungs than in TO lungs (0.18 ± 0.007 vs. 0.008 ± 0.004; p = 0.07). SP-C concentration was higher in PFC lungs than in TO lungs (37.9 ± 7.6 vs. 20.0 ± 5.4 pg/mL; p = 0.005), and both early (12.4 ± 1.7 g/mL; p = 0.007) and late tissue control lungs (15.1 ± 5.0 pg/mL; p = 0.0008). CONCLUSION: During AP support, intratracheal PFC prevents lung injury and promotes normal lung development better than crystalloid or amniotic fluid with TO.


Assuntos
Animais Recém-Nascidos , Órgãos Artificiais , Oxigenação por Membrana Extracorpórea , Fluorocarbonos/administração & dosagem , Lesão Pulmonar/prevenção & controle , Animais , Feminino , Pulmão/crescimento & desenvolvimento , Placenta/fisiologia , Gravidez , Ovinos
19.
ASAIO J ; 64(4): 552-556, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28937410

RESUMO

An artificial placenta (AP) using venovenous extracorporeal life support (VV-ECLS) could represent a paradigm shift in the treatment of extremely premature infants. However, AP support could potentially alter cerebral oxygen delivery. We assessed cerebral perfusion in fetal lambs on AP support using near-infrared spectroscopy (NIRS) and carotid arterial flow (CAF). Fourteen premature lambs at estimated gestational age (EGA) 130 days (term = 145) underwent cannulation of the right jugular vein and umbilical vein with initiation of VV-ECLS. An ultrasonic flow probe was placed around the right carotid artery (CA), and a NIRS sensor was placed on the scalp. Lambs were not ventilated. CAF, percentage of regional oxygen saturation (rSO2) as measured by NIRS, hemodynamic data, and blood gases were collected at baseline (native placental support) and regularly during AP support. Fetal lambs were maintained on AP support for a mean of 55 ± 27 hours. Baseline rSO2 on native placental support was 40% ± 3%, compared with a mean rSO2 during AP support of 50% ± 11% (p = 0.027). Baseline CAF was 27.4 ± 5.4 ml/kg/min compared with an average CAF of 23.7 ± 7.7 ml/kg/min during AP support. Cerebral fractional tissue oxygen extraction (FTOE) correlated negatively with CAF (r = -0.382; p < 0.001) and mean arterial pressure (r = -0.425; p < 0.001). FTOE weakly correlated with systemic O2 saturation (r = 0.091; p = 0.017). Cerebral oxygenation and blood flow in premature lambs are maintained during support with an AP. Cerebral O2 extraction is inversely related to carotid flow and is weakly correlated with systemic O2 saturation.


Assuntos
Órgãos Artificiais , Circulação Cerebrovascular/fisiologia , Placenta , Animais , Feminino , Feto , Humanos , Masculino , Gravidez , Carneiro Doméstico
20.
J Laparoendosc Adv Surg Tech A ; 28(2): 223-228, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29261090

RESUMO

INTRODUCTION: Interestingly, the pediatric and adult surgeons perform vastly different operations in similar patient populations. Little is known about long-term recurrence and quality of life (QOL) in adolescents and young adults undergoing inguinal hernia repair. We evaluated long-term patient-centered outcomes in this population to determine the optimal operative approach. METHODS: The medical records of patients 12-25 years old at the time of a primary inguinal hernia repair at our institution from 2000 to 2016 were retrospectively reviewed. Patients then completed a phone survey of their postoperative courses and QOL. Outcomes of high ligation performed by pediatric surgeons were compared to those of mesh repairs by adult general surgeons. The primary outcome was recurrence. Secondary outcomes included time to recurrence, postoperative complications, and patient-centered outcomes. A Cox regression analysis was used to determine associations for recurrence. RESULTS: Of 213 patients identified, 143 (67.1%) were repaired by adult surgeons and 70 (32.9%) repaired by pediatric surgeons. Overall recurrence rate for the entire cohort was 5.7% with a median time to recurrence of 3.5 years (interquartile range 120-2155 days). High ligation and mesh repairs had similar rates of recurrence (6.3 versus 5.8, P = .57) and postoperative complications (17% versus 16%, P = .45). 101/213 (47%) patients completed the phone survey. Of those surveyed, 20% reported postoperative pain, 10% had residual numbness and tingling, and 10% of patients complained of intermittent bulging. Overall, a survey comparison showed no differences among subgroups. CONCLUSIONS: In adolescents and young adults, the long-term recurrence rate after inguinal hernia repair is ∼6% with time to recurrence approaching 4 years. Outcomes of high ligation and mesh repair are similar, highlighting the need for individualized approaches for this unique population.


Assuntos
Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Ligadura/métodos , Telas Cirúrgicas/efeitos adversos , Adolescente , Adulto , Criança , Feminino , Herniorrafia/efeitos adversos , Humanos , Ligadura/efeitos adversos , Masculino , Avaliação de Resultados da Assistência ao Paciente , Complicações Pós-Operatórias/epidemiologia , Qualidade de Vida , Recidiva , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...