Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Coll Radiol ; 14(2): 224-230, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27927592

RESUMO

PURPOSE: Quantification of the frequency, understanding the motivation, and documentation of the changes made by CT technologists at scan time are important components of monitoring a quality CT workflow. METHODS: CT scan acquisition data were collected from one CT scanner for a period of 1 year. The data included all relevant acquisition parameters needed to define the technical side of a CT protocol. An algorithm was created to sort these data in groups of irradiation events with the same combinations of scan acquisition parameters. For scans modified at scan time, it was hypothesized that these examinations would show up only once in the organized data. A classification scheme was developed to place each "one-off" examination into a category related to what motivated the scan-time change. RESULTS: A total of 132,707 irradiation events were organized into 434 groups of unique scan acquisition parameters. One hundred forty-four irradiation events had acquisition parameters that showed up only once in the data. These "one-offs" were classified as follows: 25% represented rarely used protocols, 17% were due to service scans, 16% were changed for unknown and therefore undesired reasons, 15% were changed by technologists trying to adapt protocol to patient size, 12% were allowable scan-time changes, 8% of scans had tube current maxed out, and 6% of scans were changed to a higher dose mode as requested by radiologists. CONCLUSIONS: The outcome of this study suggests many areas of needed technologist training and chances for optimizing this institution's CT protocols.


Assuntos
Fidelidade a Diretrizes/estatística & dados numéricos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Exposição à Radiação/prevenção & controle , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Tomografia Computadorizada por Raios X/normas , Padrões de Prática Médica/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/normas , Exposição à Radiação/estatística & dados numéricos , Wisconsin
3.
Radiol Manage ; 37(6): 25-9; quiz 30-1, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26710573

RESUMO

At the University of Wisconsin Madison Department of Radiology, CT protocol management requires maintenance of thousands of parameters for each scanner. Managing CT protocols is further complicated by the unique configurability of each scanner. Due to recent Joint Commission requirements, now all CT protocol changes must be documented and reviewed by a site's CT protocol optimization team. The difficulty of managing the CT protocols was not in assembling the protocols, but in managing and implementing changes. This is why a wiki based solution for protocol management was implemented. A wiki inherently keeps track of all changes, logging who made the changes and when, allowing for editing and viewing permissions to be controlled, as well as allowing protocol changes to be instantly relayed to all scanner locations.


Assuntos
Protocolos Clínicos , Internet , Informática Médica , Tomografia Computadorizada por Raios X , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...