1.
Comput Methods Programs Biomed ; 242: 107814, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37722311

RESUMO

BACKGROUND AND OBJECTIVE: The Oxford Classification for IgA nephropathy is the most successful example of an evidence-based nephropathology classification system. The aim of our study was to replicate the glomerular components of Oxford scoring with an end-to-end deep learning pipeline that involves automatic glomerular segmentation followed by classification for mesangial hypercellularity (M), endocapillary hypercellularity (E), segmental sclerosis (S) and active crescents (C). METHODS: A total number of 1056 periodic acid-Schiff (PAS) whole slide images (WSIs), coming from 386 kidney biopsies, were annotated. Several detection models for glomeruli, based on the Mask R-CNN architecture, were trained on 587 WSIs, validated on 161 WSIs, and tested on 127 WSIs. For the development of segmentation models, 20,529 glomeruli were annotated, of which 16,571 as training and 3958 as validation set. The test set of the segmentation module comprised of 2948 glomeruli. For the Oxford classification, 6206 expert-annotated glomeruli from 308 PAS WSIs were labelled for M, E, S, C and split into a training set of 4298 glomeruli from 207 WSIs, and a test set of 1908 glomeruli. We chose the best-performing models to construct an end-to-end pipeline, which we named MESCnn (MESC classification by neural network), for the glomerular Oxford classification of WSIs. RESULTS: Instance segmentation yielded excellent results with an AP50 ranging between 78.2-80.1 % (79.4 ± 0.7 %) on the validation and 75.1-77.7 % (76.5 ± 0.9 %) on the test set. The aggregated Jaccard Index was between 73.4-75.9 % (75.0 ± 0.8 %) on the validation and 69.1-73.4 % (72.2 ± 1.4 %) on the test set. At granular glomerular level, Oxford Classification was best replicated for M with EfficientNetV2-L with a mean ROC-AUC of 90.2 % and a mean precision/recall area under the curve (PR-AUC) of 81.8 %, best for E with MobileNetV2 (ROC-AUC 94.7 %) and ResNet50 (PR-AUC 75.8 %), best for S with EfficientNetV2-M (mean ROC-AUC 92.7 %, mean PR-AUC 87.7 %), best for C with EfficientNetV2-L (ROC-AUC 92.3 %) and EfficientNetV2-S (PR-AUC 54.7 %). At biopsy-level, correlation between expert and deep learning labels fulfilled the demands of the Oxford Classification. CONCLUSION: We designed an end-to-end pipeline for glomerular Oxford Classification on both a granular glomerular and an entire biopsy level. Both the glomerular segmentation and the classification modules are freely available for further development to the renal medicine community.


Assuntos
Aprendizado Profundo , Glomerulonefrite por IGA , Humanos , Glomerulonefrite por IGA/diagnóstico , Glomerulonefrite por IGA/patologia , Taxa de Filtração Glomerular , Glomérulos Renais/patologia , Rim/diagnóstico por imagem
2.
J Gastroenterol ; 56(7): 659-672, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34117903

RESUMO

BACKGROUND: To screen and validate novel stool protein biomarkers of colorectal cancer (CRC). METHODS: A novel aptamer-based screen of 1317 proteins was used to uncover elevated proteins in the stool of patients with CRC, as compared to healthy controls (HCs) in a discovery cohort. Selected biomarker candidates from the discovery cohort were ELISA validated in three independent cross-sectional cohorts comprises 76 CRC patients, 15 adenoma patients, and 63 healthy controls, from two different ethnicities. The expression of the potential stool biomarkers within CRC tissue was evaluated using single-cell RNA-seq datasets. RESULTS: A total of 92 proteins were significantly elevated in CRC samples as compared to HCs in the discovery cohort. Among Caucasians, the 5 most discriminatory proteins among the 16 selected proteins, ordered by their ability to distinguish CRC from adenoma and healthy controls, were MMP9, haptoglobin, myeloperoxidase, fibrinogen, and adiponectin. Except myeloperoxidase, the others were significantly associated with depth of tumor invasion. The 8 stool proteins with the highest AUC values were also discriminatory in a second cohort of Indian CRC patients. Several of the stool biomarkers elevated in CRC were also expressed within CRC tissue, based on the single-cell RNA-seq analysis. CONCLUSIONS: Stool MMP9, fibrinogen, myeloperoxidase, and haptoglobin emerged as promising CRC stool biomarkers, outperforming stool Hemoglobin. Longitudinal studies are warranted to assess the clinical utility of these novel biomarkers in early diagnosis of CRC.


Assuntos
Aptâmeros de Nucleotídeos , Biomarcadores/análise , Neoplasias Colorretais/diagnóstico , Fezes , Área Sob a Curva , Estudos Transversais , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Curva ROC , Estatísticas não Paramétricas
3.
IEEE J Biomed Health Inform ; 25(2): 315-324, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33206612

RESUMO

The kidney biopsy based diagnosis of Lupus Nephritis (LN) is characterized by low inter-observer agreement, with misdiagnosis being associated with increased patient morbidity and mortality. Although various Computer Aided Diagnosis (CAD) systems have been developed for other nephrohistopathological applications, little has been done to accurately classify kidneys based on their kidney level Lupus Glomerulonephritis (LGN) scores. The successful implementation of CAD systems has also been hindered by the diagnosing physician's perceived classifier strengths and weaknesses, which has been shown to have a negative effect on patient outcomes. We propose an Uncertainty-Guided Bayesian Classification (UGBC) scheme that is designed to accurately classify control, class I/II, and class III/IV LGN (3 class) at both the glomerular-level classification task (26,634 segmented glomerulus images) and the kidney-level classification task (87 MRL/lpr mouse kidney sections). Data annotation was performed using a high throughput, bulk labeling scheme that is designed to take advantage of Deep Neural Network's (or DNNs) resistance to label noise. Our augmented UGBC scheme achieved a 94.5% weighted glomerular-level accuracy while achieving a weighted kidney-level accuracy of 96.6%, improving upon the standard Convolutional Neural Network (CNN) architecture by 11.8% and 3.5% respectively.


Assuntos
Nefrite Lúpica , Animais , Teorema de Bayes , Humanos , Rim/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos MRL lpr , Redes Neurais de Computação , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...