Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Physiol Funct Imaging ; 44(3): 228-239, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38014525

RESUMO

INTRODUCTION: Brachial cuff-based methods are increasingly used to estimate aortic systolic blood pressure (aoSBP). However, there are several unresolved issues. AIMS: to determine to what extent the scheme used to calibrate brachial records (1) can affect noninvasive obtained aoSBP levels, and consequently, the level of agreement with the aoSBP recorded invasively, and (2) how different ways of calibrating ultimately impact the relationship between aoSBP and cardiac properties. METHODS: brachial and aortic blood pressure (BP) was simultaneously obtained by invasive (catheterisation) and noninvasive (brachial oscillometric-device) methods (89 subjects). aoSBP was noninvasive obtained using three calibration schemes: 'SD': diastolic and systolic brachial BP, 'C': diastolic and calculated brachial mean BP (bMBP), 'Osc': diastolic and oscillometry-derived bMBP. Agreement between invasive and noninvasive aoSBP, and associations between BP and echocardiographic-derived parameters were analysed. CONCLUSIONS: 'C' and 'SD' schemes generated aoSBP levels lower than those recorded invasively (mean errors: 6.9 and 10.1 mmHg); the opposite was found when considering 'Osc'(mean error: -11.4 mmHg). As individuals had higher invasive aoSBP, the three calibration schemes increasingly underestimated aoSBP levels; and viceversa. The 'range' of invasive aoSBP in which the calibration schemes reach the lowest error level (-5-5 mmHg) is different: 'C': 103-131 mmHg; 'Osc': 159-201 mmHg; 'SD':101-124 mmHg. The calibration methods allowed reaching levels of association between aoSBP and cardiac characteristics, somewhat lower, but very similar to those obtained when considering invasive aoSBP. There is no evidence of a clear superiority of one calibration method over another when considering the association between aoSBP and cardiac characteristics.


Assuntos
Pressão Arterial , Determinação da Pressão Arterial , Humanos , Calibragem , Pressão Sanguínea/fisiologia , Pressão Arterial/fisiologia , Aorta , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiologia
2.
Front Cardiovasc Med ; 10: 1207069, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37560119

RESUMO

Background: Recently it has been proposed a new approach to estimate aortic systolic blood pressure (aoSBP) without the need for specific devices, operator-dependent techniques and/or complex wave propagation models/algorithms. The approach proposes aoSBP can be quantified from brachial diastolic and mean blood pressure (bDBP, bMBP) as: aoSBP = bMBP2/bDBP. It remains to be assessed to what extent the method and/or equation used to obtain the bMBP levels considered in aoSBP calculation may affect the estimated aoSBP, and consequently the agreement with aoSBP invasively recorded. Methods: Brachial and aortic pressure were simultaneously obtained invasively (catheterization) and non-invasively (brachial oscillometry) in 89 subjects. aoSBP was quantified in seven different ways, using measured (oscillometry-derived) and calculated (six equations) mean blood pressure (MBP) levels. The agreement between invasive and estimated aoSBP was analyzed (Concordance correlation coefficient; Bland-Altman Test). Conclusions: The ability of the equation "aoSBP = MBP2/DBP" to (accurately) estimate (error <5 mmHg) invasive aoSBP depends on the method and equation considered to determine bMBP, and on the aoSBP levels (proportional error). Oscillometric bMBP and/or approaches that consider adjustments for heart rate or a form factor ∼40% (instead of the usual 33%) would be the best way to obtain the bMBP levels to be used to calculate aoSBP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...