Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 12(1): 21336, 2022 12 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494470

RESUMO

We present a flyscan compatible acquisition scheme for three-modal X-Ray Computed Tomography (CT) with two-dimensional phase sensitivity. Our approach is demonstrated using a "beam tracking" setup, through which a sample's attenuation, phase (refraction) and scattering properties can be measured from a single frame, providing three complementary contrast channels. Up to now, such setups required the sample to be stepped at each rotation angle to sample signals at an adequate rate, to prevent resolution losses, anisotropic resolution, and under-sampling artefacts. However, the need for stepping necessitated a step-and-shoot implementation, which is affected by motors' overheads and increases the total scan time. By contrast, our proposed scheme, by which continuous horizontal and vertical translations of the sample are integrated with its rotation (leading to a "cycloidal-spiral" trajectory), is fully compatible with continuous scanning (flyscans). This leads to greatly reduced scan times while largely preserving image quality and isotropic resolution.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Raios X , Tomografia Computadorizada por Raios X/métodos , Artefatos , Imagens de Fantasmas
3.
Sci Rep ; 9(1): 3249, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30824838

RESUMO

Laser-wakefield accelerators (LWFAs) are high acceleration-gradient plasma-based particle accelerators capable of producing ultra-relativistic electron beams. Within the strong focusing fields of the wakefield, accelerated electrons undergo betatron oscillations, emitting a bright pulse of X-rays with a micrometer-scale source size that may be used for imaging applications. Non-destructive X-ray phase contrast imaging and tomography of heterogeneous materials can provide insight into their processing, structure, and performance. To demonstrate the imaging capability of X-rays from an LWFA we have examined an irregular eutectic in the aluminum-silicon (Al-Si) system. The lamellar spacing of the Al-Si eutectic microstructure is on the order of a few micrometers, thus requiring high spatial resolution. We present comparisons between the sharpness and spatial resolution in phase contrast images of this eutectic alloy obtained via X-ray phase contrast imaging at the Swiss Light Source (SLS) synchrotron and X-ray projection microscopy via an LWFA source. An upper bound on the resolving power of 2.7 ± 0.3 µm of the LWFA source in this experiment was measured. These results indicate that betatron X-rays from laser wakefield acceleration can provide an alternative to conventional synchrotron sources for high resolution imaging of eutectics and, more broadly, complex microstructures.

4.
Sci Rep ; 7(1): 2399, 2017 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-28546551

RESUMO

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1-100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from "noise", arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr-1, and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm-1, exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr-1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

5.
Sci Rep ; 7: 43910, 2017 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-28281679

RESUMO

Laser-wakefield accelerators are compact devices capable of delivering ultra-short electron bunches with pC-level charge and MeV-GeV energy by exploiting the ultra-high electric fields arising from the interaction of intense laser pulses with plasma. We show experimentally and through numerical simulations that a high-energy electron beam is produced simultaneously with two stable lower-energy beams that are ejected in oblique and counter-propagating directions, typically carrying off 5-10% of the initial laser energy. A MeV, 10s nC oblique beam is ejected in a 30°-60° hollow cone, which is filled with more energetic electrons determined by the injection dynamics. A nC-level, 100s keV backward-directed beam is mainly produced at the leading edge of the plasma column. We discuss the apportioning of absorbed laser energy amongst the three beams. Knowledge of the distribution of laser energy and electron beam charge, which determine the overall efficiency, is important for various applications of laser-wakefield accelerators, including the development of staged high-energy accelerators.

6.
Phys Med Biol ; 59(19): 5811-29, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25207591

RESUMO

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10(-5) neutrons cm(-2) per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.


Assuntos
Simulação por Computador , Elétrons , Dosimetria Fotográfica/métodos , Método de Monte Carlo , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria/instrumentação , Calibragem , Dosimetria Fotográfica/instrumentação , Humanos , Nêutrons , Fótons/uso terapêutico , Prótons , Radiometria/métodos , Dosagem Radioterapêutica
7.
Rev Sci Instrum ; 84(11): 113302, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24289391

RESUMO

Compton side-scattering has been used to simultaneously downshift the energy of keV to MeV energy range photons while attenuating their flux to enable single-shot, spectrally resolved, measurements of high flux X-ray sources to be undertaken. To demonstrate the technique a 1 mm thick pixelated cadmium telluride detector has been used to measure spectra of Compton side-scattered radiation from a Cobalt-60 laboratory source and a high flux, high peak brilliance X-ray source of betatron radiation from a laser-plasma wakefield accelerator.

8.
Med Phys ; 39(6Part17): 3813-3814, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28517464

RESUMO

PURPOSE: Progress in the development of compact high-energy pulsed laser- plasma wakefield accelerators is opening up the potential for using Very High Energy Electron (VHEEs) beams in the range of 150 - 250 MeV for biomedical studies. Initial experiments using VHEE for this purpose have been carried out using the ALPHA-X laser-plasma wakefield accelerator beam line at the University of Strathclyde, Glasgow, UK. The purpose of this investigation is to use Monte Carlo simulations to plan experiments and compare with characterization of the interaction of the VHEE beam using a dosimeter. METHODS: An experiment using the VHEE beam to irradiate a muscle-equivalent BANG polymer gel dosimeter has been carried out. Simulations have been used to prepare for the experiments. These were undertaken using the expected average energy for a pulse set and an energy spread approximated by Gaussian distribution. The model was implemented in FLUKA Monte Carlo code with follow up modeling using the Geant4 toolkit. The results have been compared with 1mm̂3 voxel laser CT based measurements of the dose deposited in the BANG dosimeter and with measurement of the induced radioactivity. RESULTS: The results of the measured dose from induced radioactivity have been compared with data from the FLUKA simulations. The beam model based on an average energy of particles in irradiation gives an acceptable estimate of the induced radioactivity and the dose deposited in the BANG dosimeter. Comparison with the dosimeter scanned profiles shows that the structure of the spectra of VHEE beams in the experiment and secondary scattered particles in the beam line should be accounted for in any model. Such model description of the VHEE beam for the ALPHA-X beam line has been developed. CONCLUSIONS: Monte Carlo simulations using the FLUKA code is an efficient way to plan a VHEE experiment and analyze data from measurements.

9.
Phys Rev Lett ; 105(21): 215007, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-21231315

RESUMO

Progress in laser wakefield accelerators indicates their suitability as a driver of compact free-electron lasers (FELs). High brightness is defined by the normalized transverse emittance, which should be less than 1π mm mrad for an x-ray FEL. We report high-resolution measurements of the emittance of 125 MeV, monoenergetic beams from a wakefield accelerator. An emittance as low as 1.1±0.1π mm mrad is measured using a pepper-pot mask. This sets an upper limit on the emittance, which is comparable with conventional linear accelerators. A peak transverse brightness of 5×10¹5 A m⁻¹ rad⁻¹ makes it suitable for compact XUV FELs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...