Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Heart Rhythm ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810922

RESUMO

BACKGROUND: Pulsed field ablation (PFA) and very-high power short-duration(vHPSD) radiofrequency ablation are the most recently introduced technologies for atrial fibrillation (AF) ablation. The procedural performance, safety, and effectiveness of PFA versus vHPSD is currently unknown. OBJECTIVE: To compare PFA with vHPSD for the treatment of paroxysmal/persistent AF. METHODS: We conducted an observational, multicenter study enrolling 534 consecutive patients (63±9years, 36% female) with paroxysmal (n=368,69%) or persistent (n=166,31%) AF undergoing ablation using either PFA (Farawave; n=192) or vHPSD (90W/4sec; QDOT Micro; n=342) between 2020 and 2023. Atrial tachyarrhythmia (AT) recurrence after a 1-month blanking period was the primary efficacy endpoint and was assessed both overall and in propensity score-matched patients. The primary safety endpoint was a composite of procedure-related complications. RESULTS: Successful PVI was achieved in all patients, with shorter procedure duration (PFA,70 min; vHPSD,100 min; p<0.001), but with longer fluoroscopy time (PFA,15 min; vHPSD,7 min; p<0.001) in PFA group. PFA was associated with more frequent use of general anesthesia (p<0.001). Primary safety outcome events occurred in 19 patients(3.5%), with similar prevalence in both groups (PFA,4%; vHPSD,3%; p=0.745). After a median follow-up of 12(9-12) months, survival free from recurrent AT was similar between the PFA and vHPSD groups, both overall (12-month estimate: PFA,75%; vHPSD,76%; log-rank p=0.73) and in propensity score-matched patients (n=342; 12-month estimate: PFA,75%; vHPSD,77%; log-rank p=0.980). CONCLUSION: In a large, multicenter experience, PFA was associated with more common use of general anesthesia, shorter procedural times, and longer fluoroscopy exposure compared to vHPSD ablation, with both techniques displaying superimposable safety/efficacy.

2.
J Clin Med ; 13(7)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38610635

RESUMO

There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68-98) and 98 in the athletes group (IQR 92-99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93-99) and 98 (IQR 87-99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

4.
J Clin Med ; 13(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38592178

RESUMO

Although mitral valve prolapse (MVP) is the most prevalent valvular abnormality in Western countries and generally carries a good prognosis, a small subset of patients is exposed to a significant risk of malignant ventricular arrhythmias (VAs) and sudden cardiac death (SCD), the so-called arrhythmic MVP (AMVP) syndrome. Recent work has emphasized phenotypical risk features of severe AMVP and clarified its pathophysiology. However, the appropriate assessment and risk stratification of patients with suspected AMVP remains a clinical conundrum, with the possibility of both overestimating and underestimating the risk of malignant VAs, with the inappropriate use of advanced imaging and invasive electrophysiology study on one hand, and the catastrophic occurrence of SCD on the other. Furthermore, the sports eligibility assessment of athletes with AMVP remains ill defined, especially in the grey zone of intermediate arrhythmic risk. The definition, epidemiology, pathophysiology, risk stratification, and treatment of AMVP are covered in the present review. Considering recent guidelines and expert consensus statements, we propose a comprehensive pathway to facilitate appropriate counseling concerning the practice of competitive/leisure-time sports, envisioning shared decision making and the multidisciplinary "sports heart team" evaluation of borderline cases. Our final aim is to encourage an active lifestyle without compromising patients' safety.

6.
J Interv Card Electrophysiol ; 67(3): 549-557, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37584862

RESUMO

BACKGROUND: The clinical performance of high-power, short-duration (HPSD) pulmonary vein isolation (PVI) with the novel flexible tip TactiFlex™ (TFSE) catheter, as compared to standard-power, long-duration (SPLD) PVI using the TactiCath™ (TCSE) catheter among patients undergoing catheter ablation (CA) of atrial fibrillation (AF) is currently unknown. METHODS: We conducted a prospective, observational, single-centre study including 40 consecutive patients undergoing PVI for paroxysmal/persistent AF, using HPSD ablation with the novel TFSE catheter (HPSD/TFSE group). Based on propensity score-matching, forty patients undergoing SPLD PVI with the TCSE catheter were identified (SPLD/TCSE group). In the HPSD/TFSE group, RF lesions were performed by delivering 40-50 W for 10-20 s, while in the SPLD/TCSE group, RF power was 30-35 W, targeting a lesion size index (LSI) of 4.0-5.5. The co-primary study outcomes were time required to complete PVI and first pass isolation (FPI). RESULTS: PVI was achieved in 100% of patients in both groups, and no major adverse events were observed. Remarkably, PVI time was shorter in the HPSD/TFSE, compared to the SPLD/TCSE group(9 [7-9] min vs. 50 [37-54] min; p < 0.001), while FPI rate was non-significantly higher in the former group(91% [146/160] vs 83% [134/160]; p = 0.063). Shorter procedural (108 [91-120] min vs. 173 [139-187] min, p < 0.001), total RF (9 [7-11] min vs. 43 [32-53] min, p < 0.001), fluoroscopy times(15 [10-19] min vs. 18 [13-26] min, p = 0.014), and lower DAP (1461 [860-2181] vs. 7200 [3400-20,800], p < 0.001) were recorded in the HPSD/TFSE group. A higher average impedance drop was obtained with HPSD/TFSE CA(17[17-18]Ω vs. 16 [15-17] Ω, p < 0.001). CONCLUSIONS: In our initial clinical experience, HPSD PVI with the TFSE catheter proved faster than SPLD PVI with the TCSE catheter, at least equally effective in terms of FPI, and it was associated with greater impedance drop.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Ablação por Cateter/efeitos adversos , Catéteres , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
Can J Cardiol ; 40(3): 372-384, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37923125

RESUMO

BACKGROUND: Cardiac amyloidoses (CAs) are an increasingly recognised group of infiltrative cardiomyopathies associated with high risk of adverse cardiac events. We sought to characterise the characteristics and clinical value of right ventricular (RV) electroanatomic voltage mapping (EVM) in CA. METHODS: Fifteen consecutive patients undergoing endomyocardial biopsy (EMB) for suspected CA (median age 75 years, 1st-3rd quartiles 64-78 years], 67% male) were enrolled in an observational prospective study. Each patient underwent RV high-density EVM using a multipolar catheter and EMB. The primary outcome was death or heart failure hospitalisation at 1-year follow-up. We recorded electrographic features at EMB sampling sites and electroanatomic data in the overall RV, and explored their correlations with histopathologic findings and primary outcomes events. RESULTS: A final EMB-proven diagnosis of immunoglobulin light chain or transthyretin CA was formulated in 6 and 9 patients, respectively. Electrogram amplitudes in the bipolar and unipolar configurations averaged 1.55 ± 0.44 mV and 5.14 ± 1.50 mV, respectively, in the overall RV, with lower values in AL CA patients. We found a significant inverse correlation between both bipolar and unipolar electrogram amplitude and amyloid burden according to EMB (P = 0.001 and P = 0.025, respectively). At 1-year follow-up, 7 patients (47%) experienced a primary outcome event; the extent of bipolar dense scar area at RV EVM was an independent predictor of primary outcome events at multivariable analysis (odds ratio 2.40; P = 0.037). CONCLUSIONS: In CA, electrogram amplitudes are around the lower limit of normal yet disproportionately low compared with the increased wall thickness. Out data suggest that RV electrogram amplitude may be a quantitative marker of amyloid burden, and that RV EVM may have prognostic value.


Assuntos
Amiloidose , Displasia Arritmogênica Ventricular Direita , Humanos , Masculino , Idoso , Feminino , Displasia Arritmogênica Ventricular Direita/complicações , Estudos Prospectivos , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração , Amiloidose/complicações
8.
Artigo em Inglês | MEDLINE | ID: mdl-38087147

RESUMO

BACKGROUND: Several novel technologies allowing catheter ablation (CA) with a favorable safety/efficacy profile have been recently developed, but not yet extensively clinically tested in the setting of ventricular tachycardia CA. METHODS: In this technical report, we overview technical aspects and preclinical/clinical information concerning the application of three novel CA technologies in the ventricular milieu: a pulsed field ablation (PFA) generator (CENTAURI™, Galaxy Medical) to be used with linear, contact force-sensing radiofrequency ablation catheters; a contact force-sensing radiofrequency ablation catheter equipped with six thermocouples and three microelectrodes (QDOT Micro™, Biosense-Webster), allowing high-resolution mapping and temperature-controlled CA; and a flexible and mesh-shaped irrigation tip, contact force-sensing radiofrequency ablation catheter (Tactiflex, Abbott). We also report three challenging VT cases in which CA was performed using these technologies. RESULTS: The CENTAURI system was used with the Tacticath™ (Abbott) ablation catheter to perform ventricular PFA in a patient with advanced heart failure, electrical storm, and a deep intramural septal substrate. Microelectrode mapping using QDOT Micro™ helped to refine substrate assessment in a VT patient with congenitally corrected transposition of the great arteries, and allowed the identification of the critical components of the VT circuit, which were successfully ablated. Tactiflex™ was used in two challenging CA cases (one endocardial and one epicardial), allowing acute and mid-term control of VT episodes without adverse events. CONCLUSION: The ideation and development of novel technologies initially intended to treat atrial arrhythmias and successfully implemented in the ventricular milieu is contributing to the progressive improvement in the clinical benefits derived from VT CA, making this procedure key for successful management of increasingly complex patients.

9.
Artigo em Inglês | MEDLINE | ID: mdl-37985538

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly employed in atrial fibrillation (AF) ablation procedures, with the potential to enhance procedural efficacy. Nevertheless, there is currently a lack of evidence assessing the impact of ICE on the efficiency, effectiveness, and safety outcomes in the context of novel pulsed-field ablation (PFA) for AF. PURPOSE: We aimed to assess whether the use of ICE could improve procedural parameters in a large population undergoing AF ablation with FARAPULSE™ catheter. METHODS: Consecutive patients who had undergone PFA of AF from nine Italian centers were included. In procedures where the ICE catheter was employed for guidance (ICE-guided group), it was used to maneuver the PFA catheter within the left atrium to achieve optimal contact with atrial structures. RESULTS: We analyzed 556 patients: 357 (66%) with paroxysmal AF, 499 (89.7%) de novo PVI. ICE-guided procedures (n = 138) were propensity matched with patients with a standard approach (n = 138), and their outcomes were compared. During ICE-guided procedures, no improvement in procedural metrics was recorded (ICE vs Standard, 23 ± 6 min vs 18.5 ± 9 min for time to PVI, p < 0.0001; 38.8 ± 7 vs 32.5 ± 5 number of PFA deliveries to achieve PVI, p < 0.0001; 68.8 ± 19 min vs 71.8 ± 29 min for primary operator time, p = 0.5301; 16.1 ± 8 min vs 18.2 ± 10 min for fluoroscopy time, p = 0.5476) except for support time (76.8 ± 26 min vs 91.4 ± 37 min, p = 0.0046). No major procedure-related adverse events were reported. CONCLUSION: Our findings confirmed that PFA could be consistently performed in a rapid, safe, and efficacious manner. The use of ICE to guide PFA was not associated with an improvement in procedural metrics.

10.
Eur Heart J Suppl ; 25(Suppl C): C258-C260, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125284

RESUMO

Ablation targets of persistent atrial fibrillation remain poorly understood nowadays: due to structural alterations of the left atrium, isolation of the pulmonary veins alone has proved ineffective. New ablation targets such as the posterior wall, coronary sinus, and left atrial appendage were then sought. A new catheter (QDOT Micro™) has recently been released, which has the potential to increase the safety and efficacy of the procedure: it is connected to a new radiofrequency generator that allows for temperature-controlled ablation by reducing power and increasing irrigation with the increase in tissue temperature and allows to deliver power up to 90 W for few seconds (very high-power short-duration).

11.
J Cardiovasc Electrophysiol ; 34(5): 1216-1227, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37087672

RESUMO

INTRODUCTION: The assessment of the ventricular myocardial substrate critically depends on the size of mapping electrodes, their orientation with respect to wavefront propagation, and interelectrode distance. We conducted a dual-center study to evaluate the impact of microelectrode mapping in patients undergoing catheter ablation (CA) of ventricular tachycardia (VT). METHODS: We included 21 consecutive patients (median age, 68 [12], 95% male) with structural heart disease undergoing CA for electrical storm (n = 14) or recurrent VT (n = 7) using the QDOT Micro catheter and a multipolar catheter (PentaRay, n = 9). The associations of peak-to-peak maximum standard bipolar (BVc ) and minibipolar (PentaRay, BVp ) with microbipolar (BVµMax ) voltages were respectively tested in sinus rhythm with mixed effect models. Furthermore, we compared the features of standard bipolar (BE) and microbipolar (µBE) electrograms in sinus rhythm at sites of termination with radiofrequency energy. RESULTS: BVµMax was moderately associated with both BVc (ß = .85, p < .01) and BVp (ß = .56, p < .01). BVµMax was 0.98 (95% CI: 0.93-1.04, p < .01) mV larger than corresponding BVc , and 0.27 (95% CI: 0.16-0.37, p < .01) mV larger than matching BVp in sinus rhythm, with higher percentage differences in low voltage regions, leading to smaller endocardial dense scar (2.3 [2.7] vs. 12.1 [17] cm2 , p < .01) and border zone (3.2 [7.4] vs. 4.8 [20.1] cm2 , p = .03) regions in microbipolar maps compared to standard bipolar maps. Late potentials areas were nonsignificantly greater in microelectrode maps, compared to standard electrode maps. At sites of VT termination (n = 14), µBE were of higher amplitude (0.9 [0.8] vs. 0.4 [0.2] mV, p < .01), longer duration (117 [66] vs. 74 [38] ms, p < .01), and with greater number of peaks (4 [2] vs. 2 [1], p < .01) in sinus rhythm compared to BE. CONCLUSION: microelectrode mapping is more sensitive than standard bipolar mapping in the identification of viable myocytes in SR, and may facilitate recognition of targets for CA.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Idoso , Feminino , Microeletrodos , Resultado do Tratamento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/complicações , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz
12.
Card Electrophysiol Clin ; 14(3): 401-409, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36153122

RESUMO

Nowadays, the pathophysiology mechanism of initiation and maintenance of reentrant arrhythmias, including atrial flutter, is well characterized. However, the anatomic and functional elements of the macro reentrant arrhythmias are not always well defined. In this article, we illustrate the anatomic structures that delineate the typical atrial flutter circuit, both clockwise and counterclockwise, paying attention to the inferior vena cava-tricuspid isthmus (CTI) and crista terminalis crucial role. Finally, we describe the left atrial role during typical atrial flutter, electrophysiologically a by-stander but essential in the phenotypic electrocardiogram (ECG).


Assuntos
Apêndice Atrial , Flutter Atrial , Ablação por Cateter , Eletrocardiografia , Átrios do Coração , Humanos
13.
Card Electrophysiol Clin ; 14(3): 517-532, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36153131

RESUMO

"Despite being one of the best understood cardiac arrhythmias, the clinical meaning of atrial flutter varies according to the specific context, and its optimal treatment may be limited by both the suboptimal response to rate/rhythm control drugs and by the complexity of the underlying substrate. In this article, we present a state-of-the-art overview of mechanisms, prognostic impact, and medical/interventional management options for atrial flutter in several specific patient populations, including heart failure, cardiomyopathies, muscular dystrophies, posttransplant patients, patients with respiratory disorders, athletes, and subjects with preexcitation, aiming to stimulate further research in this challenging field and facilitate appropriate patient care."


Assuntos
Fibrilação Atrial , Flutter Atrial , Cardiomiopatias , Ablação por Cateter , Fibrilação Atrial/cirurgia , Humanos
14.
Front Cardiovasc Med ; 9: 870001, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36072869

RESUMO

Catheter ablation (CA) is a fundamental therapeutic option for the treatment of recurrent ventricular arrhythmias. Notwithstanding the tremendous improvements in the available technology and the increasing amount of evidence in support of CA, in some patients the procedure fails, or is absolutely contraindicated due to technical or clinical issues. In these cases, the clinical management of patients is highly challenging, and mainly involves antiarrhythmic drugs escalation. Over the last 5 years, stereotactic arrhythmia radioablation (STAR) has been introduced into clinical practice, with several small studies reporting favorable arrhythmia-free outcomes, without severe side effects at a short to mid-term follow-up. In the present systematic review, we provide an overview of the available studies on stereotactic arrhythmia radioablation, by describing the potential indications and technical aspects of this promising therapy.

15.
J Clin Med ; 11(7)2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35407408

RESUMO

A radiofrequency energy lesion transmurality marker incorporating power, contact force, and time (Ablation Index, AI) was shown to be associated with outcomes of catheter ablation (CA) of multiple arrhythmias, but was never systematically assessed in the CA of focal atrial tachycardias (AT). We aimed to evaluate the role of AI as a predictor of outcomes in focal AT CA, and therefore, retrospectively included 45 consecutive patients undergoing CA for focal AT in four referral electrophysiology laboratories. Clinical and procedural information were collected. For each patient, maximum and mean (by averaging maximum AI values for each radiofrequency ablation lesion) AI were measured. The primary outcome was focal AT-free survival, and was systematically assessed with periodical Holter monitors or cardiac implantable electronic devices. CA was acutely effective in each case; however, 20% (n = 9) of the study population experienced a focal AT recurrence over a median follow-up of 288 days. Both maximum and mean AI values were significantly higher among patients without AT recurrences (maximum AI = 568 ± 91, mean AI = 426 ± 105) than in patients with AT relapses (maximum AI = 447 ± 142, mean AI = 352 ± 76, p = 0.036, and p = 0.028, respectively). The optimal cutoffs associated with freedom from recurrences were 461 for maximum AI (sensitivity, 0.89; specificity, 0.56) and 301 for mean AI (sensitivity, 0.97; specificity, 0.44). In a time-to-event analysis, maximum AI was significantly associated with survival free from AT recurrence (p = 0.001), whereas mean AI was not (p = 0.08). In summary, maximum AI is the best procedural parameter associated with the outcomes of CA for focal AT, and may help standardize the procedural approach.

16.
J Clin Med ; 11(5)2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35268267

RESUMO

Cardiovascular diseases (CVD) have a lower prevalence in women than men; although, a higher mortality rate and a poorer prognosis are more common in women. However, there is a misperception of CVD female risk since women have commonly been considered more protected so that the real threat is vastly underestimated. Consequently, female patients are more likely to be treated less aggressively, and a lower rate of diagnostic and interventional procedures is performed in women than in men. In addition, there are substantial sex differences in CVD, so different strategies are needed. This review aims to evaluate the main gender-specific approaches in CVD.

17.
Minerva Cardiol Angiol ; 70(5): 628-638, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35212506

RESUMO

Over the last 20 years, catheter ablation of atrial fibrillation (AF) has evolved from a research tool into a fundamental therapeutic measure, with the potential to improve symptoms, quality of life, and even risk of major adverse cardiac events (among patients with heart failure and a reduced ejection fraction). Notwithstanding the tremendous evolution in techniques and tools, risk of AF recurrences postablation is not negligible, and a comprehensive structured follow-up is highly needed to deliver optimal patient care. In this follow-up process, monitoring of heart rhythm is quintessential to detect recurrences, and may be accomplished by means of symptoms-triggered, intermittent, or continuous monitors. In recent years, the development and widespread adoption of implantable cardiac monitors, by allowing continuous long-term rhythm assessment, has surged to become the gold-standard strategy, both in research settings and in clinical practice. In this review, we both summarize the present state-of-the art on the detection of postablation AF recurrences and provide future perspectives on this emerging yet often neglected topic, aiming to give practical hints for evidence-based, personalized patient care.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Eletrocardiografia , Humanos , Qualidade de Vida , Recidiva
18.
J Cardiovasc Echogr ; 32(4): 222-224, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36994119

RESUMO

Papillary fibroelastomas (PFs) are small and pedunculated left side valves associated mass, that frequently causing cerebral embolization. We present the case of a 69-year-old male with a history of multiple ischemic strokes and a small pedunculated mass in the left ventricle outflow tract, highly suggestive of a rare case of PF in an atypical localization. Due to the clinical history and the echocardiographic aspect of the mass, he underwent surgical excision and Bentall intervention for concomitant aortic root and ascending aorta aneurysm. The pathological analysis of the surgical specimen confirmed the diagnosis of PF.

19.
J Clin Med ; 10(15)2021 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-34361996

RESUMO

The therapeutic dilemma between rhythm and rate control in the management of atrial fibrillation (AF) is still unresolved and electrical or pharmacological cardioversion (CV) frequently represents a useful strategy. The most recent guidelines recommend anticoagulation according to individual thromboembolic risk. Vitamin K antagonists (VKAs) have been routinely used to prevent thromboembolic events. Non-vitamin K antagonist oral anticoagulants (NOACs) represent a significant advance due to their more predictable therapeutic effect and more favorable hemorrhagic risk profile. In hemodynamically unstable patients, an emergency electrical cardioversion (ECV) must be performed. In this situation, intravenous heparin or low molecular weight heparin (LMWH) should be administered before CV. In patients with AF occurring within less than 48 h, synchronized direct ECV should be the elective procedure, as it restores sinus rhythm quicker and more successfully than pharmacological cardioversion (PCV) and is associated with shorter length of hospitalization. Patients with acute onset AF were traditionally considered at lower risk of thromboembolic events due to the shorter time for atrial thrombus formation. In patients with hemodynamic stability and AF for more than 48 h, an ECV should be planned after at least 3 weeks of anticoagulation therapy. Alternatively, transesophageal echocardiography (TEE) to rule out left atrial appendage thrombus (LAAT) should be performed, followed by ECV and anticoagulation for at least 4 weeks. Theoretically, the standardized use of TEE before CV allows a better stratification of thromboembolic risk, although data available to date are not univocal.

20.
J Cardiovasc Med (Hagerstown) ; 22(8): 618-623, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34009837

RESUMO

AIMS: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is mainly reserved for patients with drug-refractory or drug-intolerant symptomatic atrial fibrillation. We evaluated a large cohort of patients treated in a real-world setting and examined the safety and efficacy profile of CBA when applied as a first-line treatment for atrial fibrillation. METHODS: In total, 249 patients (23% women; 56 ±â€Š13 years; mean left atrial diameter 41 ±â€Š7 mm; 73.5% paroxysmal atrial fibrillation; and 26.5% persistent atrial fibrillation) underwent an index PVI by CBA. Data were collected prospectively in the framework of the 1STOP ClinicalService project, involving 26 Italian cardiology centers. RESULTS: Median procedure and fluoroscopy times were 90.0 and 21.0 min, respectively. Acute procedural success was 99.8%. Acute/periprocedural complications were observed in seven patients (2.8%), including: four transient diaphragmatic paralyses, one pericardial effusion (not requiring any intervention), one transient ischemic attack, and one minor vascular complication. The Kaplan--Meier freedom from atrial fibrillation recurrence was 86.3% at 12 months and 76% at 24 months. Seventeen patients (6.8%) had a repeat catheter ablation procedure during the follow-up period. At last follow-up, 10% of patients were on an anticoagulation therapy, whereas 6.8% were on an antiarrhythmic drug. CONCLUSION: In our multicenter real-world experience, PVI by CBA in a first-line atrial fibrillation patient population was well tolerated, effective, and promising. CBA with a PVI strategy can be used to treat patients with paroxysmal and persistent atrial fibrillation with good acute procedural success, short procedure times, and acceptable safety. CLINICAL TRIAL REGISTRATION: clinicaltrials.gov (NCT01007474).


Assuntos
Fibrilação Atrial , Criocirurgia , Complicações Pós-Operatórias , Prevenção Secundária/estatística & dados numéricos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Segurança do Paciente , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Saúde Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...