Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Electrocardiol ; 83: 26-29, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38295539

RESUMO

BACKGROUND: Alcohol consumption is associated with a higher increased risk of atrial fibrillation (AF), but the acute effects on cardiac electrophysiology in humans remain poorly understood. The HOw ALcohol InDuces Atrial TachYarrhythmias (HOLIDAY) Trial revealed that alcohol shortened pulmonary vein atrial effective refractory periods, but more global electrophysiologic changes gleaned from the surface ECG have not yet been reported. METHODS: This was a secondary analysis of the HOLIDAY Trial. During AF ablation procedures, 100 adults were randomized to intravenous alcohol titrated to 0.08% blood alcohol concentration versus a volume and osmolarity-matched, masked, placebo. Intervals measured from 12­lead ECGs were compared between pre infusion and at infusion steady state (20 min). RESULTS: The average age was 60 years and 11% were female. No significant differences in the P-wave duration, PR, QRS or QT intervals, were present between alcohol and placebo arms. However, infusion of alcohol was associated with a statistically significant relative shortening of the JT interval (r: -14.73, p = 0.048) after multivariable adjustment. CONCLUSION: Acute exposure to alcohol was associated with a relative reduction in the JT interval, reflecting shortening of ventricular repolarization. These acute changes may reflect a more global shortening of refractoriness, suggesting immediate proarrhythmic effects pertinent to the atria and ventricles.


Assuntos
Fibrilação Atrial , Eletrocardiografia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Concentração Alcoólica no Sangue , Átrios do Coração , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
J Trauma Acute Care Surg ; 93(6): 838-845, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-35393381

RESUMO

BACKGROUND: Trauma-induced secondary cardiac injury has been associated with significant adverse cardiovascular events. Speckle tracking echocardiography is a novel technology that allows an accurate and reproducible cardiac structure and function assessment. We evaluated the left ventricle (LV) myocardial deformation by speckle tracking echocardiography in a hemorrhagic shock (HS) swine model. METHODS: Seven healthy male Landrace pigs were included in this study. Severe HS was reached through three sequentially blood withdraws of 20% of estimated blood volume, and it was maintained for 60 minutes. Volume resuscitation was performed using all precollected blood volume. A 1.8- to 4.2-MHz phased-array transducer was used to acquire the two-dimensional echocardiography images. Strain measurements were obtained semiautomatically by wall motion tracking software. Results are presented as medians and interquartile ranges and compared using Wilcoxon rank-sum test. A p value of <0.05 was considered statistically significant. RESULTS: The median weight was 32 (26.1-33) kg, and the median total blood volume withdrawn was 1,100 (1,080-1,190) mL. During the severe HS period, the median arterial systemic pressure was 39 (36-46) mm Hg, and the cardiac index was 1.7 (1.6-2.0) L/min/m 2 . There was statistically significant absolute decrease in the global longitudinal strain 2 hours postresuscitation comparing with the basal measurements (-9.6% [-10.7 to -8.0%] vs. -7.9% [-8.1 to -7.4%], p = 0.03). There were no statistically significant differences between the basal and 2 hours postresuscitation assessments in the invasive/noninvasive hemodynamic, other two-dimensional echocardiogram (LV ejection fraction, 49.2% [44-54.3%] vs. 53.2% [51.5-55%]; p = 0.09), and circumferential strain (-10.6% [-14.4 to -9.0%] vs. -8.5% [-8.6 to -5.2%], p = 0.06) parameters. CONCLUSION: In this experimental swine model of controlled HS, LV global longitudinal strain analysis accurately characterizes the timing and magnitude of subclinical cardiac dysfunction associated with trauma-induced secondary cardiac injury.


Assuntos
Ecocardiografia Tridimensional , Choque Hemorrágico , Masculino , Suínos , Animais , Ventrículos do Coração/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Choque Hemorrágico/diagnóstico por imagem , Reprodutibilidade dos Testes , Ecocardiografia/métodos
4.
Sci Rep ; 11(1): 22683, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34811411

RESUMO

Better models to identify individuals at low risk of ventricular arrhythmia (VA) are needed for implantable cardioverter-defibrillator (ICD) candidates to mitigate the risk of ICD-related complications. We designed the CERTAINTY study (CinE caRdiac magneTic resonAnce to predIct veNTricular arrhYthmia) with deep learning for VA risk prediction from cine cardiac magnetic resonance (CMR). Using a training cohort of primary prevention ICD recipients (n = 350, 97 women, median age 59 years, 178 ischemic cardiomyopathy) who underwent CMR immediately prior to ICD implantation, we developed two neural networks: Cine Fingerprint Extractor and Risk Predictor. The former extracts cardiac structure and function features from cine CMR in a form of cine fingerprint in a fully unsupervised fashion, and the latter takes in the cine fingerprint and outputs disease outcomes as a cine risk score. Patients with VA (n = 96) had a significantly higher cine risk score than those without VA. Multivariate analysis showed that the cine risk score was significantly associated with VA after adjusting for clinical characteristics, cardiac structure and function including CMR-derived scar extent. These findings indicate that non-contrast, cine CMR inherently contains features to improve VA risk prediction in primary prevention ICD candidates. We solicit participation from multiple centers for external validation.


Assuntos
Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Desfibriladores Implantáveis/efeitos adversos , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/terapia , Prevenção Primária/métodos , Idoso , Cicatriz/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Aprendizado Profundo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
5.
Acad Radiol ; 28(3): 356-363, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32279912

RESUMO

RATIONALE AND OBJECTIVES: Left Atrial (LA) adverse remodeling is an important predictor of morbidity and mortality in several cardiovascular (CV) diseases. Our goals were to quantify and provide reference ranges for LA structure and function using feature tracking cine cardiac magnetic resonance. MATERIALS AND METHODS: 2526 participants of the Multiethnic Study of Atherosclerosis study who had feature tracking cine cardiac magnetic resonance derived LA data and were free of atrial fibrillation/flutter and prior CV events at year five follow-up examination (2010-2012) were included in this study. LA phasic indexed volumes: maximum (LAVi max), minimum (LAVi min), and preatrial contraction (LAVi preA); LA empty fractions: total, passive, and active (LAtEF, LApEF, and LAaEF); LA longitudinal strain: maximum and preatrial contraction (S max and S preA); and LA longitudinal strain rate: systolic (SR max) and early/late diastolic (SR e and SR a) were measured. Age, gender, and race/ethnicity-specific reference ranges were identified. Also, reference values in a select subgroup of healthy participants free of traditional CV risk factors at the time of exam date were reported. RESULTS: The mean ± SD for LAVi max, LAVi min, LAVi preA, S max, SR e, and SR a were in the 45-65-year-old participants: (33.8 ± 10 mL/m2), (14.5 ± 6.4 mL/m2), (24.8 ± 8.2 mL/m2), (34.6 ± 13.8 %), (-1.4 ± 0.7 s-1), (-2.1 ± 1 s-1) and in the ≥ 65-year-old participants: (35 ± 11.5 mL/m2), (16.6 ± 8.3 mL/m2), (27.6 ± 9.9 mL/m2), (31.2 ± 14.3 %), (-1 ± 0.6 s-1), (-2.1 ± 1 s-1) respectively. Younger individuals had Powered by Editorial Manager and ProduXion Manager from Aries Systems Corporation smaller LA volumes and better LA function compared to their older counterparts. Similar findings were observed in Chinese-Americans as compared to Whites. CONCLUSION: This study provides reference values of LA structure and function parameters from a healthy multiethnic community-based population aged 53-94 years evaluated by FTMRI.


Assuntos
Aterosclerose , Fibrilação Atrial , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/diagnóstico por imagem , Função do Átrio Esquerdo , Etnicidade , Átrios do Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade
6.
J Cardiovasc Electrophysiol ; 31(7): 1719-1725, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32510679

RESUMO

INTRODUCTION: Advanced interatrial block (IAB) on a 12-lead electrocardiogram (ECG) is a predictor of stroke, incident atrial fibrillation (AF), and AF recurrence after catheter ablation. The objective of this study was to determine which features of IAB structural remodeling is associated with left atrium (LA) magnetic resonance imaging structure and function. METHODS/RESULTS: We included 152 consecutive patients (23% nonparoxysmal AF) who underwent preprocedural ECG and cardiac magnetic resonance (CMR) in sinus rhythm before catheter ablation of AF. IAB was defined as P-wave duration ≥120 ms, and was considered partial if P-wave was positive and advanced if P-wave had a biphasic morphology in inferior leads. From cine CMR and late gadolinium enhancement, we derived LA maximum and minimum volume indices, strain, LA fibrosis, and LA dyssynchrony. A total of 77 patients (50.7% paroxysmal) had normal P-wave, 52 (34.2%) partial IAB, and 23 (15.1%) advanced IAB. Patients with advanced IAB had significantly higher LA minimum volume index (25.7 vs 19.9 mL/m2 , P = .010), more LA fibrosis (21.9% vs 13.1%, P = .020), and lower LA maximum strain rate (0.99 vs 1.18, P = .007) than those without. Advanced IAB was independently associated with LA (minimum [P = .032] and fibrosis [P = .009]). P-wave duration was also independently associated with LA fibrosis (ß = .33; P = .049) and LA mechanical dyssynchrony (ß = 2.01; P = .007). CONCLUSION: Advanced IAB is associated with larger LA volumes, lower emptying fraction, and more fibrosis. Longer P-wave duration is also associated with more LA fibrosis and higher LA mechanical dyssynchrony.


Assuntos
Fibrilação Atrial , Bloqueio Interatrial , Idoso , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina , Fibrilação Atrial/diagnóstico por imagem , Meios de Contraste , Eletrocardiografia , Feminino , Fibrose , Gadolínio , Átrios do Coração/diagnóstico por imagem , Humanos , Bloqueio Interatrial/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
7.
J Am Soc Echocardiogr ; 33(7): 878-887.e3, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32336609

RESUMO

BACKGROUND: The relationship between long-term obesity and left atrial (LA) structure and function is not entirely understood. We examined the association of cumulative body mass index (cBMI) with LA remodeling using three-dimensional (3D) speckle-tracking echocardiography (STE). METHODS: The Coronary Artery Risk Development in Young Adults (CARDIA) study is a community-based cohort of black and white, men and women, ages 18-30 years at baseline in 1985-86 from four U.S. centers. This study included 2,144 participants who had satisfactory image quality and body mass index measurements during the entire follow-up period. The 3D STE-derived LA parameters were maximum, minimum, and pretrial contraction volumes; total, passive, and active emptying fraction; maximum systolic longitudinal strain; and early and late diastolic longitudinal strain rates. Multivariable linear regression analyses stratified by sex assessed the relationship between cBMI and 3D STE-derived LA parameters, adjusting for demographics and traditional cardiovascular. RESULTS: The mean age of the cohort was 55 ± 3.6 years; 54.8% were women, and 46.5% were black. There were statistically significant additive sex interactions for the association between cBMI and LA minimum contraction value, maximum systolic longitudinal strain, and early and late diastolic longitudinal strain rates. In the fully adjusted model, greater cBMI was associated with lower magnitude LA longitudinal deformation (maximum systolic longitudinal strain and early and late diastolic longitudinal strain rates) in men and with higher LA emptying fraction in women. In addition, greater cBMI was associated with higher LA phasic volumes indices in both men and women. CONCLUSIONS: This study showed that while greater cBMI from early adulthood throughout middle age was associated with higher LA volumes in both genders, differences were found for LA function, with lower longitudinal deformation in men and higher reservoir and active LA function in women.


Assuntos
Remodelamento Atrial , Ecocardiografia Tridimensional , Adolescente , Adulto , Índice de Massa Corporal , Vasos Coronários , Feminino , Humanos , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Caracteres Sexuais , Adulto Jovem
8.
Circ Cardiovasc Imaging ; 12(6): e008764, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31177816

RESUMO

Background Previous studies showed that the quantity of the left atrial (LA) periatrial fat tissue predicts recurrence after catheter ablation of atrial fibrillation (AF). We hypothesized that the quality of the LA periatrial fat tissue, measured by the mean computed tomography attenuation, predicts recurrence after AF ablation independent of the quantity of the LA periatrial fat tissue. Methods We included 143 consecutive patients with drug-refractory AF referred for the first catheter ablation of AF (62.2±10 years, 40% nonparoxysmal AF). All participants had a preablation cardiac computed tomography. We measured the quantity of the LA periatrial fat tissue by the area (millimeter square) and the quality by the mean computed tomography attenuation (Hounsfield units) in a standard 4-chamber view. Results Patients with AF recurrence after ablation (n=57) had a significantly larger fat area (167.6 [interquartile range, 124.1-255] versus 145.4 [95.6-229.3] mm2; P=0.018) and a higher fat attenuation (-92.0±9.8 versus -96.5±9.4 Hounsfield units; P=0.006) than those without recurrence (controls). LA fat attenuation was correlated with LA fat volume and LA bipolar voltage by invasive mapping and was associated with AF recurrence after adjusting for clinical risk factors, including body mass index, AF type, LA dimension, and fat area (hazard ratio, 2.65; P=0.001). Conclusions The quality of the LA periatrial fat tissue is an independent predictor of recurrence after the first AF ablation. Assessment of LA periatrial fat attenuation can improve AF ablation outcomes by refining patient selection.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Resultado do Tratamento
9.
Arq Bras Cardiol ; 112(4): 441-450, 2019 04.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30994724

RESUMO

BACKGROUND: Recent studies suggest that left atrial (LA) late gadolinium enhancement (LGE) can quantify the underlying tissue remodeling that harbors atrial fibrillation (AF). However, quantification of LA-LGE requires labor-intensive magnetic resonance imaging acquisition and postprocessing at experienced centers. LA intra-atrial dyssynchrony assessment is an emerging imaging technique that predicts AF recurrence after catheter ablation. We hypothesized that 1) LA intra-atrial dyssynchrony is associated with LA-LGE in patients with AF and 2) LA intra-atrial dyssynchrony is greater in patients with persistent AF than in those with paroxysmal AF. METHOD: We conducted a cross-sectional study comparing LA intra-atrial dyssynchrony and LA-LGE in 146 patients with a history of AF (60.0 ± 10.0 years, 30.1% nonparoxysmal AF) who underwent pre-AF ablation cardiac magnetic resonance (CMR) in sinus rhythm. Using tissue-tracking CMR, we measured the LA longitudinal strain in two- and four-chamber views. We defined intra-atrial dyssynchrony as the standard deviation (SD) of the time to peak longitudinal strain (SD-TPS, in %) and the SD of the time to the peak pre-atrial contraction strain corrected by the cycle length (SD-TPSpreA, in %). We used the image intensity ratio (IIR) to quantify LA-LGE. RESULTS: Intra-atrial dyssynchrony analysis took 5 ± 9 minutes per case. Multivariable analysis showed that LA intra-atrial dyssynchrony was independently associated with LA-LGE. In addition, LA intra-atrial dyssynchrony was significantly greater in patients with persistent AF than those with paroxysmal AF. In contrast, there was no significant difference in LA-LGE between patients with persistent and paroxysmal AF. LA intra-atrial dyssynchrony showed excellent reproducibility and its analysis was less time-consuming (5 ± 9 minutes) than the LA-LGE (60 ± 20 minutes). CONCLUSION: LA Intra-atrial dyssynchrony is a quick and reproducible index that is independently associated with LA-LGE to reflect the underlying tissue remodeling.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial/fisiologia , Imageamento por Ressonância Magnética/métodos , Idoso , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Estudos Transversais , Ecocardiografia/métodos , Eletrocardiografia/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia , Fatores de Tempo
10.
Arq. bras. cardiol ; 112(4): 441-450, Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001289

RESUMO

Abstract Background: Recent studies suggest that left atrial (LA) late gadolinium enhancement (LGE) can quantify the underlying tissue remodeling that harbors atrial fibrillation (AF). However, quantification of LA-LGE requires labor-intensive magnetic resonance imaging acquisition and postprocessing at experienced centers. LA intra-atrial dyssynchrony assessment is an emerging imaging technique that predicts AF recurrence after catheter ablation. We hypothesized that 1) LA intra-atrial dyssynchrony is associated with LA-LGE in patients with AF and 2) LA intra-atrial dyssynchrony is greater in patients with persistent AF than in those with paroxysmal AF. Method: We conducted a cross-sectional study comparing LA intra-atrial dyssynchrony and LA-LGE in 146 patients with a history of AF (60.0 ± 10.0 years, 30.1% nonparoxysmal AF) who underwent pre-AF ablation cardiac magnetic resonance (CMR) in sinus rhythm. Using tissue-tracking CMR, we measured the LA longitudinal strain in two- and four-chamber views. We defined intra-atrial dyssynchrony as the standard deviation (SD) of the time to peak longitudinal strain (SD-TPS, in %) and the SD of the time to the peak pre-atrial contraction strain corrected by the cycle length (SD-TPSpreA, in %). We used the image intensity ratio (IIR) to quantify LA-LGE. Results: Intra-atrial dyssynchrony analysis took 5 ± 9 minutes per case. Multivariable analysis showed that LA intra-atrial dyssynchrony was independently associated with LA-LGE. In addition, LA intra-atrial dyssynchrony was significantly greater in patients with persistent AF than those with paroxysmal AF. In contrast, there was no significant difference in LA-LGE between patients with persistent and paroxysmal AF. LA intra-atrial dyssynchrony showed excellent reproducibility and its analysis was less time-consuming (5 ± 9 minutes) than the LA-LGE (60 ± 20 minutes). Conclusion: LA Intra-atrial dyssynchrony is a quick and reproducible index that is independently associated with LA-LGE to reflect the underlying tissue remodeling.


Resumo Fundamento: Estudos recentes sugerem que o realce tardio com gadolínio (RTG) no átrio esquerdo (AE) pode quantificar a remodelação tecidual subjacente que abriga a fibrilação atrial (FA). No entanto, a quantificação do RTG-AE requer um trabalho intenso de aquisição por ressonância magnética e pós-processamento em centros experientes. A avaliação da dessincronia intra-atrial no AE é uma técnica de imagem emergente que prediz a recorrência da FA após ablação por cateter. Nós levantamos as hipóteses de que 1) a dessincronia intra-atrial está associada ao RTG-AE em pacientes com FA e 2) a dessincronia intra-atrial é maior em pacientes com FA persistente do que naqueles com FA paroxística. Método: Realizamos um estudo transversal comparando a dessincronia intra-atrial no AE e o RTG-AE em 146 pacientes com história de FA (60,0 ± 10,0 anos, 30,1% com FA não paroxística) submetidos à ressonância magnética cardíaca (RMC) durante ritmo sinusal antes da ablação da FA. Com utilização de RMC com tissue tracking, medimos o strain longitudinal do AE em cortes de duas e quatro câmaras. Definimos a dessincronia intra-atrial como o desvio padrão (DP) do tempo até o pico do strain longitudinal (DP-TPS, em %) e o DP do tempo até o pico do strain antes da contração atrial corrigido pela duração do ciclo (DP-TPSpreA, em %). Utilizamos a razão da intensidade da imagem (RIM) para quantificar o RTG-AE. Resultados: A análise da dessincronia intra-atrial levou 9 ± 5 minutos por caso. A análise multivariada mostrou que a dessincronia intra-atrial no AE esteve independentemente associada ao RTG-AE. Além disso, a dessincronia intra-atrial no AE foi significativamente maior em pacientes com FA persistente do que naqueles com FA paroxística. Por outro lado, não houve diferença significativa no RTG-AE entre pacientes com FA persistente e paroxística. A dessincronia intra-atrial no AE mostrou excelente reprodutibilidade e sua análise foi menos demorada (5 ± 9 minutos) do que o RTG-AE (60 ± 20 minutos). Conclusão: A dessincronia intra-atrial no AE é um índice rápido, reprodutível e independentemente associado ao RTG-AE para indicar remodelação tecidual subjacente. (Arq Bras Cardiol. 2019; 112(4):441-450)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Remodelamento Atrial/fisiologia , Fibrilação Atrial/terapia , Volume Sistólico/fisiologia , Fatores de Tempo , Ecocardiografia/métodos , Modelos Lineares , Variações Dependentes do Observador , Estudos Transversais , Reprodutibilidade dos Testes , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem
11.
JACC Cardiovasc Imaging ; 12(2): 310-319, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29361492

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the usefulness of intra-atrial dyssynchrony as a marker of underlying left atrial (LA) remodeling to predict recurrence after the first atrial fibrillation (AF) ablation. BACKGROUND: Catheter ablation for AF remains far from curative with relatively high recurrence rates. One of the causes of recurrence is poor patient selection out of a diverse patient population with different degrees of LA remodeling. METHODS: We included 208 patients with a history of AF (59.4 ± 10.0 years of age; 26.0% nonparoxysmal AF) referred for catheter ablation of AF who underwent pre-ablation cardiac magnetic resonance in sinus rhythm. Clinical follow-up was 20 ± 6 months. Using tissue tracking cardiac magnetic resonance, we measured the LA longitudinal strain in each of 12 equal-length segments in 2- and 4-chamber views. We defined intra-atrial dyssynchrony as the standard deviation of the time to the peak longitudinal strain corrected by the cycle length (SD-time to peak strain [TPS], %). RESULTS: Patients with AF recurrence after ablation (n = 101) had significantly higher SD-TPS than those without (n = 107; 3.9% vs. 2.2%; p < 0.001). Multivariable cox analysis showed that SD-TPS was associated with recurrence after adjusting for clinical risk factors, AF type, LA structure and function, and fibrosis (p < 0.001). Furthermore, receiver-operating characteristics analysis showed SD-TPS improved prediction of recurrence better than clinical risk factors, LA structure and function, and fibrosis. CONCLUSIONS: Intra-atrial dyssynchrony during sinus rhythm is an independent predictor of recurrence after the first catheter ablation of paroxysmal or persistent AF. Assessment of intra-atrial dyssynchrony may improve ablation outcomes by refining patient selection.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Imagem Cinética por Ressonância Magnética , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
JACC Clin Electrophysiol ; 4(12): 1519-1525, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30573114

RESUMO

OBJECTIVES: The aim of the current investigation is to examine whether use of high-frequency jet ventilation (HFJV) during pulmonary vein isolation (PVI) performed with force-sensing catheters is associated with improved outcomes. BACKGROUND: Catheter ablation is well established as therapy for symptomatic atrial fibrillation (AF). Reconnection following PVI is commonly observed during repeat ablation procedures. Technologies that may optimize catheter stability and lesion delivery include both force-sensing ablation catheters and HFJV. METHODS: Patients undergoing PVI at Johns Hopkins Hospital were prospectively enrolled in a registry. The study compared procedural characteristics, adverse event rates, and 1-year procedural outcomes in patients undergoing PVI supported either by standard ventilation or HFJV. Patient and procedural aspects were otherwise constant. RESULTS: Eighty-four HFJV patients and 84 matched control patients with 1-year outcome data were identified. Atrial arrhythmia recurrence occurred in 26 of 84 HFJV patients (31%) and 42 of 84 control patients (50%; p = 0.019). In patients with paroxysmal AF, arrhythmia recurrence in HFJV and control patients was 27.3% and 47.3%, respectively (p = 0.045). In patients with persistent AF, arrhythmia recurrence rates were not significantly different (37.9% in HFJV patients, 55.2% in control patients; p = 0.184). On multivariate analysis, HFJV was independently associated with improved freedom from arrhythmia recurrence. Vasopressor use during HFJV cases was significantly higher than during standard ventilation (79.7% vs. 22.4%; p = 0.001). Indices of catheter stability and contact force adequacy were significantly higher in the HFJV patients than in control patients. Complication rates in the 2 groups were similarly low. CONCLUSIONS: Use of HFJV in patients undergoing PVI with radiofrequency force-sensing catheters is associated with improved outcomes, without appreciable increase in adverse procedural events.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Ablação por Cateter/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
13.
Eur Heart J Cardiovasc Imaging ; 19(9): 977-984, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29982431

RESUMO

Aims: To evaluate the association of cumulative blood pressure (BP) from young adulthood to middle age with left atrial (LA) structure/function as assessed by three-dimensional echocardiography (3DE) in a large longitudinal bi-racial population study. Methods and results: We conducted a prospective post hoc analysis of individuals enrolled at the Coronary Artery Risk Development in Young Adults, which is a multi-centre bi-racial cohort with 30 years of follow-up. Cumulative systolic and diastolic BP levels were defined by summing the product of average millimetres of mercury and the years between each two consecutive clinic visits over 30 years of follow-up. Multivariable linear regression analyses were used to assess the relationship between cumulative systolic and diastolic BP with 3DE LA structure and function, adjusting for demographics and traditional cardiovascular risk factors. A total of 1033 participants were included, mean age was 55.4 ± 3.5 years, 55.2% women, 43.9% blacks. Cumulative systolic BP had stronger correlations than cumulative diastolic BP. Higher cumulative systolic BP was independently associated with higher 3D LA volumes: maximum (ß = 1.74, P = 0.004), pre-atrial contraction (ß = 1.87, P < 0.001), minimum (ß = 0.76, P = 0.04), total emptying (ß = 0.98, P = 0.006), active emptying (ß = 1.12, P < 0.001), and lower magnitude 3D LA early diastolic strain rate (ß = 0.05, P = 0.02). Higher cumulative diastolic BP was independently associated with higher 3D LA active emptying volume (ß = 0.66, P = 0.002), lower magnitude 3D LA early diastolic strain rate (ß = 0.05, P = 0.004), and higher magnitude 3D LA late diastolic strain rate (ß = -0.04, P = 0.05). Conclusion: Higher cumulative BP from early adulthood throughout middle age was associated with adverse LA remodelling evaluated by 3D echocardiography.


Assuntos
Pressão Sanguínea/fisiologia , Ecocardiografia Tridimensional/métodos , Hipertensão/diagnóstico por imagem , Adulto , Fatores Etários , Função do Átrio Esquerdo/fisiologia , Remodelamento Atrial/fisiologia , Determinação da Pressão Arterial/métodos , Doença da Artéria Coronariana/prevenção & controle , Feminino , Humanos , Hipertensão/fisiopatologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Sensibilidade e Especificidade , Fatores Sexuais , Sístole , Adulto Jovem
14.
Am J Cardiol ; 122(2): 242-247, 2018 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-29933926

RESUMO

The P-wave terminal force in lead V1 (PTFV1) on the 12-lead electrocardiogram (ECG) quantifies left atrial (LA) structural and electrophysiologic abnormalities. We aimed to evaluate the association between PTFV1 and cerebrovascular accident (CVA) as well as LA structure and function in patients with atrial fibrillation (AF). We conducted a cross-sectional study of 229 patients with AF (60 ± 10years, 72% men) with (n = 21) and without (n = 208) a history of CVA, who underwent preablation ECG and cardiac magnetic resonance in sinus rhythm. PTFV1 was defined as the duration (in milliseconds) of the downward deflection of the P wave in lead V1 multiplied by the absolute value of its amplitude (in microvolts) on ECG. PTFV1 is associated with LA minimum volume (Vmin) and left ventricular ejection fraction but not associated with the extent of LA fibrosis quantified by cardiac magnetic resonance late gadolinium enhancement. In addition, PTFV1 is associated with CVA independent of the CHA2DS2-VASc score and LA Vmin (odds ratio 1.23; 95% confidence interval 1.08 to 1.40; p = 0.002). Furthermore, PTFV1 has an incremental value over the CHA2DS2-VASc score as a marker of CVA (p <0.001). In conclusion, ECG-defined PTFV1 is independent marker of stroke in patients with AF and reflects the underlying LA remodeling. Our findings suggest that evaluation of PTFV1 can improve the current risk stratification of stroke.


Assuntos
Fibrilação Atrial/complicações , Função do Átrio Esquerdo/fisiologia , Remodelamento Atrial/fisiologia , Eletrocardiografia , Átrios do Coração/fisiopatologia , Medição de Risco , Acidente Vascular Cerebral/etiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos Transversais , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Humanos , Incidência , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Estados Unidos/epidemiologia
15.
JACC Clin Electrophysiol ; 4(1): 59-68, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29520376

RESUMO

Background: Bipolar voltage mapping, as part of atrial fibrillation (AF) ablation, is traditionally performed in a point-by-point (PBP) approach using single-tip ablation catheters. Alternative techniques for fibrosis-delineation include fast-anatomical mapping (FAM) with multi-electrode circular catheters, and late gadolinium-enhanced magnetic-resonance imaging (LGE-MRI). The correlation between PBP, FAM, and LGE-MRI fibrosis assessment is unknown. Objective: In this study, we examined AF substrate using different modalities (PBP, FAM, and LGE-MRI mapping) in patients presenting for an AF ablation. Methods: LGE-MRI was performed pre-ablation in 26 patients (73% males, age 63±8years). Local image-intensity ratio (IIR) was used to normalize myocardial intensities. PBP- and FAM-voltage maps were acquired, in sinus rhythm, prior to ablation and co-registered to LGE-MRI. Results: Mean bipolar voltage for all 19,087 FAM voltage points was 0.88±1.27mV and average IIR was 1.08±0.18. In an adjusted mixed-effects model, each unit increase in local IIR was associated with 57% decrease in bipolar voltage (p<0.0001). IIR of >0.74 corresponded to bipolar voltage <0.5 mV. A total of 1554 PBP-mapping points were matched to the nearest FAM-point. In an adjusted mixed-effects model, log-FAM bipolar voltage was significantly associated with log-PBP bipolar voltage (ß=0.36, p<0.0001). At low-voltages, FAM-mapping distribution was shifted to the left compared to PBP-mapping; at intermediate voltages, FAM and PBP voltages were overlapping; and at high voltages, FAM exceeded PBP-voltages. Conclusion: LGE-MRI, FAM and PBP-mapping show good correlation in delineating electro-anatomical AF substrate. Each approach has fundamental technical characteristics, the awareness of which allows proper assessment of atrial fibrosis.


Assuntos
Fibrilação Atrial , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estudos Prospectivos
16.
Eur Heart J Cardiovasc Imaging ; 19(4): 433-441, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29579200

RESUMO

Aims: We sought to evaluate the relationship between left atrial (LA) mechanical dyssynchrony and history of stroke or transient ischaemic attack (TIA) in patients with atrial fibrillation (AF). We hypothesized that mechanical dyssynchrony of the LA is associated with history of stroke/TIA independent of LA function and Cardiac failure, Hypertension, Age, Diabetes, Stroke/transient ischaemic attack (TIA), VAscular disease, and Sex category (CHA2DS2-VASc) score in patients with AF. Methods and results: We conducted a cross-sectional study of 246 patients with a history of AF (59 ± 10 years, 29% female, 26% non-paroxysmal AF) referred for catheter ablation to treat drug-refractory AF who underwent preablation cardiac magnetic resonance (CMR) in sinus rhythm. Using tissue-tracking CMR, we measured the LA longitudinal strain and strain rate in each of 12 equal-length segments in two- and four-chamber views. We defined indices of LA mechanical dyssynchrony, including the standard deviation of the time to the peak longitudinal strain (SD-TPS). Patients with a prior history of stroke or TIA (n = 23) had significantly higher SD-TPS than those without (n = 223) (39.9 vs. 23.4 ms, P < 0.001). Multivariable analysis showed that SD-TPS was associated with stroke/TIA after adjusting for the CHA2DS2-VASc score, LA minimum index volume, and the peak LA longitudinal strain (P < 0.001). The receiver-operating characteristics curve showed that SD-TPS identified patients with stroke/TIA more accurately than CHA2DS2-VASc score alone (c-statistics: 0.82 vs. 0.75, P < 0.001). Conclusion: Higher mechanical dyssynchrony of the LA during sinus rhythm is associated with a history of stroke/TIA in patients with AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Ataque Isquêmico Transitório/epidemiologia , Imagem Cinética por Ressonância Magnética/métodos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Idoso , Análise de Variância , Fibrilação Atrial/fisiopatologia , Comorbidade , Estudos Transversais , Bases de Dados Factuais , Ecocardiografia Doppler/métodos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Prospectivos , Curva ROC , Medição de Risco , Acidente Vascular Cerebral/fisiopatologia , Análise de Sobrevida
17.
PLoS One ; 12(7): e0179459, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28678805

RESUMO

Persistent atrial fibrillation (AF) can be viewed as disintegrated patterns of information transmission by action potential across the communication network consisting of nodes linked by functional connectivity. To test the hypothesis that ablation of persistent AF is associated with improvement in both local and global connectivity within the communication networks, we analyzed multi-electrode basket catheter electrograms of 22 consecutive patients (63.5 ± 9.7 years, 78% male) during persistent AF before and after the focal impulse and rotor modulation-guided ablation. Eight patients (36%) developed recurrence within 6 months after ablation. We defined communication networks of AF by nodes (cardiac tissue adjacent to each electrode) and edges (mutual information between pairs of nodes). To evaluate patient-specific parameters of communication, thresholds of mutual information were applied to preserve 10% to 30% of the strongest edges. There was no significant difference in network parameters between both atria at baseline. Ablation effectively rewired the communication network of persistent AF to improve the overall connectivity. In addition, successful ablation improved local connectivity by increasing the average clustering coefficient, and also improved global connectivity by decreasing the characteristic path length. As a result, successful ablation improved the efficiency and robustness of the communication network by increasing the small-world index. These changes were not observed in patients with AF recurrence. Furthermore, a significant increase in the small-world index after ablation was associated with synchronization of the rhythm by acute AF termination. In conclusion, successful ablation rewires communication networks during persistent AF, making it more robust, efficient, and easier to synchronize. Quantitative analysis of communication networks provides not only a mechanistic insight that AF may be sustained by spatially localized sources and global connectivity, but also patient-specific metrics that could serve as a valid endpoint for therapeutic interventions.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/cirurgia , Idoso , Algoritmos , Fibrilação Atrial/fisiopatologia , Feminino , Coração/fisiopatologia , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Recidiva , Resultado do Tratamento
18.
Med Phys ; 44(9): 4677-4686, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28639400

RESUMO

PURPOSE: This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise then degrades the accuracy of motion estimation. Moreover, even if the scan was performed during the sinus rhythm, the cardiac motion observed in CT images may not be cyclic with patients with atrial fibrillation. In this study, we propose to use two CT scan data, one for CT angiography at a quiescent phase at a standard dose and the other for CFA over the entire heart beat at a lower dose. METHODS: We have made the following four modifications to an image-based cardiac motion estimation method we have previously developed for a full-dose retrospectively gated coronary CT angiography: (a) a full-dose prospectively gated coronary CT angiography image acquired at the least motion phase was used as the reference image; (b) a three-dimensional median filter was applied to lower-dose retrospectively gated cardiac images acquired at 20 phases over one heartbeat in order to reduce image noise; (c) the strength of the temporal regularization term was made adaptive; and (d) a one-dimensional temporal filter was applied to the estimated motion vector field in order to decrease jaggy motion patterns. We describe the conventional method iME1 and the proposed method iME2 in this article. Five observers assessed the accuracy of the estimated motion vector field of iME2 and iME1 using a 4-point scale. The observers repeated the assessment with data presented in a new random order 1 week after the first assessment session. RESULTS: The study confirmed that the proposed iME2 was robust against the mismatch of noise levels, contrast enhancement levels, and shapes of the chambers. There was a statistically significant difference between iME2 and iME1 (accuracy score, 2.08 ± 0.81 versus 2.77 ± 0.98, P < 0.01) and the improvement by the score of + 0.69 seemed clinically relevant. Inter-observer concordance was good: The inter-class correlation coefficient was 0.63 and Kendall's rank correlation coefficients were in the range of 0.41-0.67 (P < 0.01), respectively. Intra-observer reproducibility between sessions was good with the inter-class correlation coefficient of 0.76. CONCLUSION: We have proposed iME2 method for CT-CFA with two CT scans. The observer study verified the robustness and accuracy of iME2 method and its improved performance over iME1 method.


Assuntos
Algoritmos , Angiografia Coronária , Tomografia Computadorizada por Raios X , Artefatos , Humanos , Movimento (Física) , Doses de Radiação , Reprodutibilidade dos Testes
19.
Magn Reson Imaging ; 42: 130-138, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28642098

RESUMO

PURPOSE: Left atrial (LA) structure and function are important markers of adverse cardiovascular outcomes. Tissue-tracking cardiovascular magnetic resonance (CMR) accurately quantifies LA volume, strain, and strain rate based on biplane long-axis imaging. We aimed to assess the accuracy of the LA indices quantification from single-plane tissue-tracking CMR. METHODS: We included 388 subjects (mean age 57±13, male 70%) whose cine CMR images in sinus rhythm were available in both four-chamber and two-chamber views: 162 patients from the Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD) Study, 208 patients from atrial fibrillation cohort, and 18 healthy volunteers. The group was divided into the training set (n=291) and the test set (n=97). In the training set, we compared the LA indices derived from biplane imaging and single-plane imaging (a four-chamber view), and developed regression equations. In the test set, we used the regression equations to estimate the LA indices from the single-plane imaging, and quantified the accuracy of the estimation against the LA indices from the biplane. RESULTS: In the training set, all the LA indices from the single-plane imaging tended to be systematically underestimated compared with those from the biplane imaging, however, the correlation coefficient was high (r2=0.73-0.90, p<0.001). In the test set, LA volumetric indices showed excellent reproducibility (intra-class correlation coefficient (ICC): 0.91-0.92) with relatively low variability (16.3-22.3%); For LA strain and strain rate indices, reproducibility was excellent (ICC: 0.81-0.93), however, the variability was slightly higher than that of volumetric indices (21.7-25.4%). CONCLUSIONS: LA volumetric indices measured from single-plane tissue-tracking CMR are highly accurate and reproducible with reference to those derived from the standard biplane imaging. The reproducibility of LA strain and strain rate indices from single-plane tissue-tracking CMR is excellent but the variability is higher than that of the volumetric indices.


Assuntos
Função do Átrio Esquerdo/fisiologia , Átrios do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Análise de Regressão , Reprodutibilidade dos Testes , Estresse Mecânico
20.
J Cardiovasc Electrophysiol ; 28(7): 796-805, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28429529

RESUMO

INTRODUCTION: Inappropriate implantable cardioverter-defibrillator (ICD) shocks, commonly caused by atrial fibrillation (AF), are associated with an increased mortality. Because impaired left atrial (LA) function predicts development of AF, we hypothesized that impaired LA function predicts inappropriate shocks beyond a history of AF. METHODS AND RESULTS: We prospectively analyzed the association between LA function and incident inappropriate shocks in primary prevention ICD candidates. In the Prospective Observational Study of ICD (PROSE-ICD), we assessed LA function using tissue-tracking cardiac magnetic resonance (CMR) prior to ICD implantation. A total of 162 patients (113 males, age 56 ± 15 years) were included. During the mean follow-up of 4.0 ± 2.9 years, 26 patients (16%) experienced inappropriate shocks due to AF (n = 19; 73%), supraventricular tachycardia (n = 5; 19%), and abnormal sensing (n = 2; 8%). In univariable analyses, inappropriate shocks were associated with AF history prior to ICD implantation, age below 70 years, QRS duration less than 120 milliseconds, larger LA minimum volume, lower LA stroke volume, lower LA emptying fraction, impaired LA maximum and preatrial contraction strains (Smax and SpreA ), and impaired LA strain rate during left ventricular systole and atrial contraction (SRs and SRa ). In multivariable analysis, impaired Smax (hazard ratio [HR]: 0.96, P = 0.044), SpreA (HR: 0.94, P = 0.030), and SRa (HR: 0.25, P < 0.001) were independently associated with inappropriate shocks. The receiver-operating characteristics curve showed that SRa improved the predictive value beyond the patient demographics including AF history (P = 0.033). CONCLUSION: Impaired LA function assessed by tissue-tracking CMR is an independent predictor of inappropriate shocks in primary prevention ICD candidates beyond AF history.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo/fisiologia , Desfibriladores Implantáveis/efeitos adversos , Prevenção Primária/métodos , Adulto , Idoso , Fibrilação Atrial/prevenção & controle , Desfibriladores Implantáveis/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevenção Primária/tendências , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...