Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vet Diagn Invest ; 29(5): 654-659, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28548572

RESUMO

Feline leukemia virus (FeLV) is an oncogenic retrovirus of cats. Immunoassays for the p27 core protein of FeLV aid in the detection of FeLV infections. Commercial microtiter-plate ELISAs have rapid protocols and visual result interpretation, limiting their usefulness in high-throughput situations. The purpose of our study was to validate the PetChek FeLV 15 ELISA, which is designed for the reference laboratory, and incorporates sequential, orthogonal screening and confirmatory protocols. A cutoff for the screening assay was established with 100% accuracy using 309 feline samples (244 negative, 65 positive) defined by the combined results of FeLV PCR and an independent reference p27 antigen ELISA. Precision of the screening assay was measured using a panel of 3 samples (negative, low-positive, and high-positive). The intra-assay coefficient of variation (CV) was 3.9-7.9%; the inter-assay CV was 6.0-8.6%. For the confirmatory assay, the intra-assay CV was 3.0-4.7%, and the inter-assay CV was 7.4-9.7%. The analytical sensitivity for p27 antigen was 3.7 ng/mL for inactivated whole FeLV and 1.2 ng/mL for purified recombinant FeLV p27. Analytical specificity was demonstrated based on the absence of cross-reactivity to related retroviruses. No interference was observed for samples containing added bilirubin, hemoglobin, or lipids. Based on these results, the new high-throughput design of the PetChek FeLV 15 ELISA makes it suitable for use in reference laboratory settings and maintains overall analytical performance.


Assuntos
Ensaio de Imunoadsorção Enzimática/veterinária , Vírus da Leucemia Felina/imunologia , Leucemia Felina/diagnóstico , Antígeno Nuclear de Célula em Proliferação/isolamento & purificação , Animais , Gatos , Vírus da Leucemia Felina/isolamento & purificação , Leucemia Felina/virologia , Reação em Cadeia da Polimerase/veterinária , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Vet Diagn Invest ; 27(4): 414-21, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26077545

RESUMO

The measurement of N-terminal pro-B-type natriuretic peptide (NT-proBNP), a biomarker for heart stress detectable in blood, has been shown to have clinical utility in cats with heart disease. A second-generation feline enzyme-linked immunosorbent assay (Cardiopet® proBNP, IDEXX Laboratories Inc., Westbrook, Maine) was developed to measure NT-proBNP in routine feline plasma or serum samples with improved analyte stability. Results of the analytical validation for the second-generation assay are presented. Analytic sensitivity was 10 pmol/l. Accuracy of 103.5% was determined via serial dilutions of 6 plasma samples. Coefficients of variation for intra-assay, interassay, and total precision were in the ranges of 1.6-6.3%, 4.3-8.8%, and 10.1-15.1%, respectively. Repeatability across 2 lots for both serum and plasma had an average coefficient of determination (r(2)) of 0.99 and slope of 1.11. Stability of the analyte was found to be high. In serum samples held at 4°C for 24-72 hr, the mean percent recovery from time zero was ≥99%. In serum samples held at 25°C for 24 hr, the mean percent recovery from time zero was 91.9%, and for 48 hr, 85.6%. A method comparison of the first- and second-generation assays with a clinically characterized population of cats revealed no difference in the tests' ability to differentiate levels of NT-proBNP between normal cats and cats with occult cardiomyopathy (P < 0.001). Results from our study validate that the second-generation feline Cardiopet proBNP assay can measure NT-proBNP in routine feline plasma and serum samples with accuracy and precision.


Assuntos
Biomarcadores/sangue , Gatos/sangue , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Animais , Doenças do Gato/sangue , Doenças do Gato/diagnóstico , Ensaio de Imunoadsorção Enzimática/veterinária , Cardiopatias/sangue , Cardiopatias/diagnóstico , Cardiopatias/veterinária , Valores de Referência , Reprodutibilidade dos Testes
3.
J Vet Diagn Invest ; 27(1): 61-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25525139

RESUMO

N-terminal pro-B-type natriuretic peptide (NT-proBNP) has been shown to have clinical utility as a biomarker in dogs with heart disease. There were several limitations associated with early diagnostic assay formats including a limited dynamic range and the need for protease inhibitors to maintain sample stability. A second-generation Cardiopet® proBNP enzyme-linked immunosorbent assay (IDEXX Laboratories Inc., Westbrook, Maine) was developed to address these limitations, and the present study reports the results of the analytical method validation for the second-generation assay. Coefficients of variation for intra-assay, interassay, and total precision based on 8 samples ranged from 3.9% to 8.9%, 2.0% to 5.0%, and 5.5% to 10.6%, respectively. Analytical sensitivity was established at 102 pmol/l. Accuracy averaged 102.0% based on the serial dilutions of 5 high-dose canine samples. Bilirubin, lipids, and hemoglobin had no effect on results. Reproducibility across 3 unique assay lots was excellent with an average coefficient of determination (r (2)) of 0.99 and slope of 1.03. Both ethylenediamine tetra-acetic acid plasma and serum gave equivalent results at time of blood draw (slope = 1.02, r (2) = 0.89; n = 51) but NT-proBNP was more stable in plasma at 25°C with median half-life measured at 244 hr and 136 hr for plasma and serum, respectively. Plasma is the preferred sample type and is considered stable up to 48 hr at room temperature whereas serum should be frozen or refrigerated when submitted for testing. Results of this study validate the second-generation canine Cardiopet proBNP assay for accurate and precise measurement of NT-proBNP in routine sample types from canine patients.


Assuntos
Doenças do Cão/diagnóstico , Ensaio de Imunoadsorção Enzimática/veterinária , Cardiopatias/veterinária , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Animais , Cães , Cardiopatias/diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J AOAC Int ; 85(2): 355-64, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11990019

RESUMO

An analytical system was developed for detection of antibiotic residues in bovine milk. The method is based on competitive fluorescent immunoassays in glass capillary tubes (U.S. Patent No. 5,624,850). The system consists of an assay cartridge containing 4 glass capillaries, a reagent tray with 4 wells of dried reagents, and a Parallux processor, which processes the assay, reads fluorescent output, and reports test results. Minimum sensitivity for detection of 6 beta-lactam antibiotics in bovine milk was determined to be penicillin-G, 3.2 ppb; ampicillin, 2.9 ppb; amoxicillin, 3.6 ppb; cloxacillin, 7.4 ppb; cephapirin, 16.3 ppb; and ceftiofur, 33.7 ppb. The assay system was also specific and sensitive for detection of incurred residues at U.S. Food and Drug Administration tolerance levels: penicillin-G, 5 ppb; ampicillin, 10 ppb; amoxicillin, 10 ppb; cloxacillin, 10 ppb; cephapirin, 20 ppb; and ceftiofur, 50 ppb. There was no interference in detection of minimum sensitivity levels of antibiotic by the presence of somatic cells at approximately 1 x 10(6) cells/mL. Milk containing 3 x 10(6) cells/mL bacteria commonly found in mastitic milk also showed no interference when tolerance levels of antibiotic were present. There was no detectable interference on results by a wide variety of non-beta-lactam drugs.


Assuntos
Antibacterianos/análise , Leite/química , Amoxicilina/análise , Ampicilina/análise , Animais , Bovinos , Cefalosporinas/análise , Cefapirina/análise , Cloxacilina/análise , Imunofluorescência , Penicilina G/análise , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...