Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
Eur Radiol ; 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656711

RESUMO

Breast cancer is the most frequently diagnosed cancer in women accounting for about 30% of all new cancer cases and the incidence is constantly increasing. Implementation of mammographic screening has contributed to a reduction in breast cancer mortality of at least 20% over the last 30 years. Screening programs usually include all women irrespective of their risk of developing breast cancer and with age being the only determining factor. This approach has some recognized limitations, including underdiagnosis, false positive cases, and overdiagnosis. Indeed, breast cancer remains a major cause of cancer-related deaths in women undergoing cancer screening. Supplemental imaging modalities, including digital breast tomosynthesis, ultrasound, breast MRI, and, more recently, contrast-enhanced mammography, are available and have already shown potential to further increase the diagnostic performances. Use of breast MRI is recommended in high-risk women and women with extremely dense breasts. Artificial intelligence has also shown promising results to support risk categorization and interval cancer reduction. The implementation of a risk-stratified approach instead of a "one-size-fits-all" approach may help to improve the benefit-to-harm ratio as well as the cost-effectiveness of breast cancer screening. KEY POINTS: Regular mammography should still be considered the mainstay of the breast cancer screening. High-risk women and women with extremely dense breast tissue should use MRI for supplemental screening or US if MRI is not available. Women need to participate actively in the decision to undergo personalized screening. KEY RECOMMENDATIONS: Mammography is an effective imaging tool to diagnose breast cancer in an early stage and to reduce breast cancer mortality (evidence level I). Until more evidence is available to move to a personalized approach, regular mammography should be considered the mainstay of the breast cancer screening. High-risk women should start screening earlier; first with yearly breast MRI which can be supplemented by yearly or biennial mammography starting at 35-40 years old (evidence level I). Breast MRI screening should be also offered to women with extremely dense breasts (evidence level I). If MRI is not available, ultrasound can be performed as an alternative, although the added value of supplemental ultrasound regarding cancer detection remains limited. Individual screening recommendations should be made through a shared decision-making process between women and physicians.

2.
Insights Imaging ; 15(1): 92, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38530547

RESUMO

OBJECTIVES: To collect real-world data about the knowledge and self-perception of young radiologists concerning the use of contrast media (CM) and the management of adverse drug reactions (ADR). METHODS: A survey (29 questions) was distributed to residents and board-certified radiologists younger than 40 years to investigate the current international situation in young radiology community regarding CM and ADRs. Descriptive statistics analysis was performed. RESULTS: Out of 454 respondents from 48 countries (mean age: 31.7 ± 4 years, range 25-39), 271 (59.7%) were radiology residents and 183 (40.3%) were board-certified radiologists. The majority (349, 76.5%) felt they were adequately informed regarding the use of CM. However, only 141 (31.1%) received specific training on the use of CM and 82 (18.1%) about management ADR during their residency. Although 266 (58.6%) knew safety protocols for handling ADR, 69.6% (316) lacked confidence in their ability to manage CM-induced ADRs and 95.8% (435) expressed a desire to enhance their understanding of CM use and handling of CM-induced ADRs. Nearly 300 respondents (297; 65.4%) were aware of the benefits of contrast-enhanced ultrasound, but 249 (54.8%) of participants did not perform it. The preferred CM injection strategy in CT parenchymal examination and CT angiography examination was based on patient's lean body weight in 318 (70.0%) and 160 (35.2%), a predeterminate fixed amount in 79 (17.4%) and 116 (25.6%), iodine delivery rate in 26 (5.7%) and 122 (26.9%), and scan time in 31 (6.8%) and 56 (12.3%), respectively. CONCLUSION: Training in CM use and management ADR should be implemented in the training of radiology residents. CRITICAL RELEVANCE STATEMENT: We highlight the need for improvement in the education of young radiologists regarding contrast media; more attention from residency programs and scientific societies should be focused on training about contrast media use and the management of adverse drug reactions. KEY POINTS: • This survey investigated training of young radiologists about use of contrast media and management adverse reactions. • Most young radiologists claimed they did not receive dedicated training. • An extreme heterogeneity of responses was observed about contrast media indications/contraindications and injection strategy.

3.
Magn Reson Imaging ; 110: 1-6, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38479541

RESUMO

PURPOSE: This pilot-study aims to assess, whether quantitatively assessed enhancing breast tissue as a percentage of the entire breast volume can serve as an indicator of breast cancer at breast MRI and whether the contrast-agent employed affects diagnostic efficacy. MATERIALS: This retrospective IRB-approved study, included 39 consecutive patients, that underwent two subsequent breast MRI exams for suspicious findings at conventional imaging with 0.1 mmol/kg gadobenic and gadoteric acid. Two independent readers, blinded to the histopathological outcome, assessed unenhanced and early post-contrast images using computer-assisted software (Brevis, Siemens Healthcare). Diagnostic performance was statistically determined for percentage of ipsilateral voxel volume enhancement and for percentage of contralateral enhancing voxel volume subtracted from ipsilateral enhancing voxel volume after crosstabulation with the dichotomized histological outcome (benign/malignant). RESULTS: Ipsilateral enhancing voxel volume versus histopathological outcome resulted in an AUC of 0.707 and 0.687 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.778 and 0.773 for gadoteric acid, reader 1 and 2, respectively. Accounting for background parenchymal enhancement by subtracting contralateral enhancing volume from ipsilateral enhancing voxel volume versus histolopathological outcome resulted in an AUC of 0.793 and 0.843 for gadobenic acid, reader 1 and 2, respectively and in an AUC of 0.692 and 0.662 for gadoteric acid, reader 1 and 2, respectively. Pairwise testing yielded no statistically significant difference both between readers and between contrast agents employed (p > 0.05). CONCLUSION: Our proposed CAD algorithm, which quantitatively assesses enhancing breast tissue as a percentage of the entire breast volume, allows indicating the presence of breast cancer.


Assuntos
Neoplasias da Mama , Mama , Meios de Contraste , Imageamento por Ressonância Magnética , Compostos Organometálicos , Humanos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Projetos Piloto , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Idoso , Mama/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Meglumina/análogos & derivados , Reprodutibilidade dos Testes , Algoritmos , Sensibilidade e Especificidade
4.
Curr Med Imaging ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38415477

RESUMO

In the world, breast cancer is the most commonly diagnosed cancer among women. Currently, MRI is the most sensitive breast imaging method for detecting breast cancer, although false positive rates are still an issue. To date, the accuracy of breast MRI is widely recognized across various clinical scenarios, in particular, staging of known cancer, screening for breast cancer in high-risk women, and evaluation of response to neoadjuvant chemotherapy. Since technical development and further clinical indications have expanded over recent years, dedicated breast radiologists need to constantly update their knowledge and expertise to remain confident and maintain high levels of diagnostic performance in breast MRI. This review aims to detail current and future applications of breast MRI, from technological requirements and advances to new multiparametric and abbreviated protocols, and ultrafast imaging, as well as current and future indications.

5.
Br J Radiol ; 97(1155): 560-566, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38265303

RESUMO

OBJECTIVES: Quality assurance of breast imaging has a long history of using test objects to optimize and follow up imaging devices. In particular, the evaluation of new techniques benefits from suitable test objects. The applicability of a phantom consisting of spiculated masses to assess image quality and its dependence on dose in flat field digital mammography (FFDM) and digital breast tomosynthesis systems (DBT) is investigated. METHODS: Two spiculated masses in five different sizes each were created from a database of clinical tumour models. The masses were produced using 3D printing and embedded into a cuboid phantom. Image quality is determined by the number of spicules identified by human observers. RESULTS: The results suggest that the effect of dose on spicule detection is limited especially in cases with smaller objects and probably hidden by the inter-reader variability. Here, an average relative inter-reader variation of the counted number of 31% was found (maximum 83%). The mean relative intra-reader variability was found to be 17%. In DBT, sufficiently good results were obtained only for the largest masses. CONCLUSIONS: It is possible to integrate spiculated masses into a cuboid phantom. It is easy to print and should allow a direct and prompt evaluation of the quality status of the device by counting visible spicules. Human readout presented the major uncertainty in this study, indicating that automated readout may improve the reproducibility and consistency of the results considerably. ADVANCES IN KNOWLEDGE: A cuboid phantom including clinical objects as spiculated lesion models for visual assessing the image quality in FFDM and DBT was developed and is introduced in this work. The evaluation of image quality works best with the two larger masses with 21 spicules.


Assuntos
Neoplasias da Mama , Mamografia , Humanos , Feminino , Reprodutibilidade dos Testes , Mamografia/métodos , Mama/diagnóstico por imagem , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Neoplasias da Mama/diagnóstico por imagem
6.
Eur Radiol ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227202

RESUMO

OBJECTIVES: To perform a survey among members of the European Society of Breast Imaging (EUSOBI) regarding the use of contrast-enhanced mammography (CEM). METHODS: A panel of nine board-certified radiologists developed a 29-item online questionnaire, distributed to all EUSOBI members (inside and outside Europe) from January 25 to March 10, 2023. CEM implementation, examination protocols, reporting strategies, and current and future CEM indications were investigated. Replies were exploratively analyzed with descriptive and non-parametric statistics. RESULTS: Among 434 respondents (74.9% from Europe), 50% (217/434) declared to use CEM, 155/217 (71.4%) seeing less than 200 CEMs per year. CEM use was associated with academic settings and high breast imaging workload (p < 0.001). The lack of CEM adoption was most commonly due to the perceived absence of a clinical need (65.0%) and the lack of resources to acquire CEM-capable systems (37.3%). CEM protocols varied widely, but most respondents (61.3%) had already adopted the 2022 ACR CEM BI-RADS® lexicon. CEM use in patients with contraindications to MRI was the most common current indication (80.6%), followed by preoperative staging (68.7%). Patients with MRI contraindications also represented the most commonly foreseen CEM indication (88.0%), followed by the work-up of inconclusive findings at non-contrast examinations (61.5%) and supplemental imaging in dense breasts (53.0%). Respondents declaring CEM use and higher CEM experience gave significantly more current (p = 0.004) and future indications (p < 0.001). CONCLUSIONS: Despite a trend towards academic high-workload settings and its prevalent use in patients with MRI contraindications, CEM use and progressive experience were associated with increased confidence in the technique. CLINICAL RELEVANCE STATEMENT: In this first survey on contrast-enhanced mammography (CEM) use and perspectives among the European Society of Breast Imaging (EUSOBI) members, the perceived absence of a clinical need chiefly drove the 50% CEM adoption rate. CEM adoption and progressive experience were associated with more extended current and future indications. KEY POINTS: • Among the 434 members of the European Society of Breast Imaging who completed this survey, 50% declared to use contrast-enhanced mammography in clinical practice. • Due to the perceived absence of a clinical need, contrast-enhanced mammography (CEM) is still prevalently used as a replacement for MRI in patients with MRI contraindications. • The number of current and future CEM indications marked by respondents was associated with their degree of CEM experience.

7.
NMR Biomed ; 37(2): e5054, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37794648

RESUMO

The aim of the current study was to compare the performance of fully automated software with human expert interpretation of single-voxel proton magnetic resonance spectroscopy (1H-MRS) spectra in the assessment of breast lesions. Breast magnetic resonance imaging (MRI) (including contrast-enhanced T1-weighted, T2-weighted, and diffusion-weighted imaging) and 1H-MRS images of 74 consecutive patients were acquired on a 3-T positron emission tomography-MRI scanner then automatically imported into and analyzed by SpecTec-ULR 1.1 software (LifeTec Solutions GmbH). All ensuing 117 spectra were additionally independently analyzed and interpreted by two blinded radiologists. Histopathology of at least 24 months of imaging follow-up served as the reference standard. Nonparametric Spearman's correlation coefficients for all measured parameters (signal-to-noise ratio [SNR] and integral of total choline [tCho]), Passing and Bablok regression, and receiver operating characteristic analysis, were calculated to assess test diagnostic performance, as well as to compare automated with manual reading. Based on 117 spectra of 74 patients, the area under the curve for tCho SNR and integrals ranged from 0.768 to 0.814 and from 0.721 to 0.784 to distinguish benign from malignant tissue, respectively. Neither method displayed significant differences between measurements (automated vs. human expert readers, p > 0.05), in line with the results from the univariate Spearman's rank correlation coefficients, as well as the Passing and Bablok regression analysis. It was concluded that this pilot study demonstrates that 1H-MRS data from breast MRI can be automatically exported and interpreted by SpecTec-ULR 1.1 software. The diagnostic performance of this software was not inferior to human expert readers.


Assuntos
Neoplasias da Mama , Colina , Humanos , Feminino , Espectroscopia de Prótons por Ressonância Magnética , Colina/análise , Projetos Piloto , Sensibilidade e Especificidade , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
8.
Eur J Radiol ; 169: 111185, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37939606

RESUMO

PURPOSE: We investigated the added value of two internationally used clinical decision rules in the management of enhancing lesions on breast MRI. METHODS: This retrospective, institutional review board approved study included consecutive patients from two different populations. Patients received breast MRI according to the recommendations of the European Society of Breast Imaging (EUSOBI). Initially, all examinations were assessed by expert readers without using clinical decision rules. All lesions rated as category 4 or 5 according to the Breast Imaging Reporting and Data System were histologically confirmed. These lesions were re-evaluated by an expert reader blinded to the histology. He assigned each lesion a Göttingen score (GS) and a Kaiser score (KS) on different occasions. To provide an estimate on inter-reader agreement, a second fellowship-trained reader assessed a subset of these lesions. Subgroup analyses based on lesion type (mass vs. non-mass), size (>1 cm vs. ≤ 1 cm), menopausal status, and significant background parenchymal enhancement were conducted. The areas under the ROC curves (AUCs) for the GS and KS were compared, and the potential to avoid unnecessary biopsies was determined according to previously established cutoffs (KS > 4, GS > 3) RESULTS: 527 lesions in 506 patients were included (mean age: 51.8 years, inter-quartile-range: 43.0-61.0 years). 131/527 lesions were malignant (24.9 %; 95 %-confidence-interval: 21.3-28.8). In all subgroups, the AUCs of the KS (median = 0.91) were higher than those of the GS (median = 0.83). Except for "premenopausal patients" (p = 0.057), these differences were statistically significant (p ≤ 0.01). Kappa agreement was higher for the KS (0.922) than for the GS (0.358). CONCLUSION: Both the KS and the GS provided added value for the management of enhancing lesions on breast MRI. The KS was superior to the GS in terms of avoiding unnecessary biopsies and showed superior inter-reader agreement; therefore, it may be regarded as the clinical decision rule of choice.


Assuntos
Neoplasias da Mama , Regras de Decisão Clínica , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Mama/patologia , Biópsia Guiada por Imagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Sensibilidade e Especificidade
9.
Eur Radiol ; 2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999727

RESUMO

OBJECTIVES: To investigate the influence of preoperative breast MRI on mastectomy and reoperation rates in patients with pure ductal carcinoma in situ (DCIS). METHODS: The MIPA observational study database (7245 patients) was searched for patients aged 18-80 years with pure unilateral DCIS diagnosed at core needle or vacuum-assisted biopsy (CNB/VAB) and planned for primary surgery. Patients who underwent preoperative MRI (MRI group) were matched (1:1) to those who did not receive MRI (noMRI group) according to 8 confounding covariates that drive referral to MRI (age; hormonal status; familial risk; posterior-to-nipple diameter; BI-RADS category; lesion diameter; lesion presentation; surgical planning at conventional imaging). Surgical outcomes were compared between the matched groups with nonparametric statistics after calculating odds ratios (ORs). RESULTS: Of 1005 women with pure unilateral DCIS at CNB/VAB (507 MRI group, 498 noMRI group), 309 remained in each group after matching. First-line mastectomy rate in the MRI group was 20.1% (62/309 patients, OR 2.03) compared to 11.0% in the noMRI group (34/309 patients, p = 0.003). The reoperation rate was 10.0% in the MRI group (31/309, OR for reoperation 0.40) and 22.0% in the noMRI group (68/309, p < 0.001), with a 2.53 OR of avoiding reoperation in the MRI group. The overall mastectomy rate was 23.3% in the MRI group (72/309, OR 1.40) and 17.8% in the noMRI group (55/309, p = 0.111). CONCLUSIONS: Compared to those going directly to surgery, patients with pure DCIS at CNB/VAB who underwent preoperative MRI had a higher OR for first-line mastectomy but a substantially lower OR for reoperation. CLINICAL RELEVANCE STATEMENT: When confounding factors behind MRI referral are accounted for in the comparison of patients with CNB/VAB-diagnosed pure unilateral DCIS, preoperative MRI yields a reduction of reoperations that is more than twice as high as the increase in overall mastectomies. KEY POINTS: • Confounding factors cause imbalance when investigating the influence of preoperative MRI on surgical outcomes of pure DCIS. • When patient matching is applied to women with pure unilateral DCIS, reoperation rates are significantly reduced in women who underwent preoperative MRI. • The reduction of reoperations brought about by preoperative MRI is more than double the increase in overall mastectomies.

10.
Eur Radiol ; 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-38008743

RESUMO

OBJECTIVES: To compare image quality of diffusion-weighted imaging (DWI) and contrast-enhanced breast MRI (DCE-T1) stratified by the amount of fibroglandular tissue (FGT) as a measure of breast density. METHODS: Retrospective, multi-reader, bicentric visual grading analysis study on breast density (A-D) and overall image and fat suppression quality of DWI and DCE-T1, scored on a standard 5-point Likert scale. Cross tabulations and visual grading characteristic (VGC) curves were calculated for fatty breasts (A/B) versus dense breasts (C/D). RESULTS: Image quality of DWI was higher in the case of increased breast density, with good scores (score 3-5) in 85.9% (D) and 88.4% (C), compared to 61.6% (B) and 53.5% (A). Overall image quality of DWI was in favor of dense breasts (C/D), with an area under the VGC curve of 0.659 (p < 0.001). Quality of DWI and DCE-T1 fat suppression increased with higher breast density, with good scores (score 3-5) for 86.9% and 45.7% of density D, and 90.2% and 42.9% of density C cases, compared to 76.0% and 33.6% for density B and 54.7% and 29.6% for density A (DWI and DCE-T1 respectively). CONCLUSIONS: Dense breasts show excellent fat suppression and substantially higher image quality in DWI images compared with non-dense breasts. These results support the setup of studies exploring DWI-based MR imaging without IV contrast for additional screening of women with dense breasts. CLINICAL RELEVANCE STATEMENT: Our findings demonstrate that image quality of DWI is robust in women with an increased amount of fibroglandular tissue, technically supporting the feasibility of exploring applications such as screening of women with mammographically dense breasts. KEY POINTS: • Image and fat suppression quality of diffusion-weighted imaging are dependent on the amount of fibroglandular tissue (FGT) which is closely connected to breast density. • Fat suppression quality in diffusion-weighted imaging of the breast is best in women with a high amount of fibroglandular tissue. • High image quality of diffusion-weighted imaging in women with a high amount of FGT in MRI supports that the technical feasibility of DWI can be explored in the additional screening of women with mammographically dense breasts.

11.
Cancers (Basel) ; 15(20)2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37894455

RESUMO

In this prospective study, 117 female patients (mean age = 53 years) with 127 histologically proven breast cancer lesions (lymph node (LN) positive = 85, LN negative = 42) underwent simultaneous 18F-FDG PET/MRI of the breast. Quantitative parameters were calculated from dynamic contrast-enhanced (DCE) imaging (tumor Mean Transit Time, Volume Distribution, Plasma Flow), diffusion-weighted imaging (DWI) (tumor ADCmean), and PET (tumor SUVmax, mean and minimum, SUVmean of ipsilateral breast parenchyma). Manual whole-lesion segmentation was also performed on DCE, T2-weighted, DWI, and PET images, and radiomic features were extracted. The dataset was divided into a training (70%) and a test set (30%). Multi-step feature selection was performed, and a support vector machine classifier was trained and tested for predicting axillary LN status. 13 radiomic features from DCE, DWI, T2-weighted, and PET images were selected for model building. The classifier obtained an accuracy of 79.8 (AUC = 0.798) in the training set and 78.6% (AUC = 0.839), with sensitivity and specificity of 67.9% and 100%, respectively, in the test set. A machine learning-based radiomics model comprising 18F-FDG PET/MRI radiomic features extracted from the primary breast cancer lesions allows high accuracy in non-invasive identification of axillary LN metastasis.

12.
Eur Radiol ; 33(11): 8103-8111, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37481690

RESUMO

OBJECTIVES: Quality assurance (QA) of image interpretation plays a key role in screening and diagnostic mammography, maintaining minimum standards and supporting continuous improvement in interpreting images. However, the QA structure across Europe shows considerable variation. The European Society of Breast Imaging (EUSOBI) conducted a survey among the members to collect information on radiologists' preferences regarding QA measures in mammography. MATERIALS AND METHODS: An anonymous online survey consisting of 25 questions was distributed to all EUSOBI members and national breast radiology bodies in Europe. The questions were designed to collect demographic characteristics, information on responders' mammography workload and data about QA measures currently used in their country. Data was analysed using descriptive statistical analysis, the χ2 test, linear regression, and Durbin-Watson statistic test. RESULTS: In total, 251 breast radiologists from 34 countries completed the survey. Most respondents were providing both screening and symptomatic services (137/251, 54.6%), working in an academic hospital (85/251, 33.9%) and reading 1000-4999 cases per year (109/251, 43.4%). More than half of them (133/251, 53%) had established QA measures in their workplace. Although less than one-third (71/251, 28.3%) had to participate in regular performance testing, the vast majority (190/251, 75.7%) agreed that a mandatory test would be helpful to improve their skills. CONCLUSION: QA measures were in place for more than half of the respondents working in screening and diagnostic mammography to evaluate their breast imaging performance. Although there were substantial differences between countries, the importance of having QA in the workplace and implemented was widely acknowledged by radiologists. CLINICAL RELEVANCE STATEMENT: Although several quality assurance (QA) measures of image interpretation are recommended by European bodies or national organisations, the QA in mammography is quite heterogenous between countries and reporting settings, and not always actively implemented across Europe. KEY POINTS: The first survey that presents radiologists' preferences regarding QA measures of image interpretation in mammography. Quality assurance measures in the workplace are better-established for breast screening compared to diagnostic mammography. Radiologists consider that performance tests would help to improve their mammography interpretation skills.


Assuntos
Neoplasias da Mama , Radiologistas , Humanos , Feminino , Mamografia/métodos , Mama , Inquéritos e Questionários , Europa (Continente) , Neoplasias da Mama/diagnóstico por imagem , Programas de Rastreamento
13.
Insights Imaging ; 14(1): 126, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37466753

RESUMO

Axillary lymphadenopathy is a common side effect of COVID-19 vaccination, leading to increased imaging-detected asymptomatic and symptomatic unilateral axillary lymphadenopathy. This has threatened to negatively impact the workflow of breast imaging services, leading to the release of ten recommendations by the European Society of Breast Imaging (EUSOBI) in August 2021. Considering the rapidly changing scenario and data scarcity, these initial recommendations kept a highly conservative approach. As of 2023, according to newly acquired evidence, EUSOBI proposes the following updates, in order to reduce unnecessary examinations and avoid delaying necessary examinations. First, recommendation n. 3 has been revised to state that breast examinations should not be delayed or rescheduled because of COVID-19 vaccination, as evidence from the first pandemic waves highlights how delayed or missed screening tests have a negative effect on breast cancer morbidity and mortality, and that there is a near-zero risk of subsequent malignant findings in asymptomatic patients who have unilateral lymphadenopathy and no suspicious breast findings. Second, recommendation n. 7 has been revised to simplify follow-up strategies: in patients without breast cancer history and no imaging findings suspicious for cancer, symptomatic and asymptomatic imaging-detected unilateral lymphadenopathy on the same side of recent COVID-19 vaccination (within 12 weeks) should be classified as a benign finding (BI-RADS 2) and no further work-up should be pursued. All other recommendations issued by EUSOBI in 2021 remain valid.

14.
Radiol Med ; 128(6): 689-698, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37221356

RESUMO

PURPOSE: To assess 18F-Fluoroethylcholine (18F-FEC) as a PET/MRI tracer in the evaluation of breast lesions, breast cancer aggressiveness, and prediction of lymph node status. MATERIALS AND METHODS: This prospective, monocentric study was approved by the ethics committee and patients gave written, informed consent. This clinical trial was registered in the EudraCT database (Number 2017-003089-29). Women who presented with suspicious breast lesions were included. Histopathology was used as reference standard. Simultaneous 18F-FEC PET/MRI of the breast was performed in a prone position with a dedicated breast coil. MRI was performed using a standard protocol before and after contrast agent administration. A simultaneous read by nuclear medicine physicians and radiologists collected the imaging data of MRI-detected lesions, including the maximum standardized 18F-FEC-uptake value of breast lesions (SUVmaxT) and axillary lymph nodes (SUVmaxLN). Differences in SUVmax were evaluated with the Mann-Whitney U test. To calculate diagnostic performance, the area under the receiver operating characteristics curve (ROC) was used. RESULTS: There were 101 patients (mean age 52.3 years, standard deviation 12.0) with 117 breast lesions included (30 benign, 7 ductal carcinomas in situ, 80 invasive carcinomas). 18F-FEC was well tolerated by all patients. The ROC to distinguish benign from malignant breast lesions was 0.846. SUVmaxT was higher if lesions were malignant (p < 0.001), had a higher proliferation rate (p = 0.011), and were HER2-positive (p = 0.041). SUVmaxLN was higher in metastatic lymph nodes, with an ROC of 0.761 for SUVmaxT and of 0.793 for SUVmaxLN. CONCLUSION: Simultaneous 18F-FEC PET/MRI is safe and has the potential to be used for the evaluation of breast cancer aggressiveness, and prediction of lymph node status.


Assuntos
Neoplasias da Mama , Fluordesoxiglucose F18 , Humanos , Feminino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia
15.
Eur Radiol ; 33(8): 5400-5410, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37166495

RESUMO

OBJECTIVES: To develop an intuitive and generally applicable system for the reporting, assessment, and documentation of ADC to complement standard BI-RADS criteria. METHODS: This was a multicentric, retrospective analysis of 11 independently conducted institutional review board-approved studies from seven institutions performed between 2007 and 2019. Breast Apparent Diffusion coefficient (ADC-B) categories comprised ADC-B0 (ADC non-diagnostic), ADC-B1 (no enhancing lesion), and ADC-B2-5. The latter was defined by plotting ADC versus cumulative malignancy rates. Statistics comprised ANOVA with post hoc testing and ROC analysis. p values ≤ 0.05 were considered statistically significant. RESULTS: A total of 1625 patients (age: 55.9 years (± 13.8)) with 1736 pathologically verified breast lesions were included. The mean ADC (× 10-3 mm2/s) differed significantly between benign (1.45, SD .40) and malignant lesions (.95, SD .39), and between invasive (.92, SD .22) and in situ carcinomas (1.18, SD .30) (p < .001). The following ADC-B categories were identified: ADC-B0-ADC cannot be assessed; ADC-B1-no contrast-enhancing lesion; ADC-B2-ADC ≥ 1.9 (cumulative malignancy rate < 0.1%); ADC-B3-ADC 1.5 to < 1.9 (0.1-1.7%); ADC-B4-ADC 1.0 to < 1.5 (10-24.5%); and ADC-B5-ADC < 1.0 (> 24.5%). At the latter threshold, a positive predictive value of 95.8% (95% CI 0.94-0.97) for invasive versus non-invasive breast carcinomas was reached. CONCLUSIONS: The breast apparent diffusion coefficient system (ADC-B) provides a simple and widely applicable categorization scheme for assessment, documentation, and reporting of apparent diffusion coefficient values in contrast-enhancing breast lesions on MRI. CLINICAL RELEVANCE STATEMENT: The ADC-B system, based on diverse MRI examinations, is clinically relevant for stratifying breast cancer risk via apparent diffusion coefficient measurements, and complements BI-RADS for improved clinical decision-making and patient outcomes. KEY POINTS: • The breast apparent diffusion coefficient category system (ADC-B) is a simple tool for the assessment, documentation, and reporting of ADC values in contrast-enhancing breast lesions on MRI. • The categories comprise ADC-B0 for non-diagnostic examinations, ADC-B1 for examinations without an enhancing lesion, and ADC-B2-5 for enhancing lesions with an increasing malignancy rate. • The breast apparent diffusion coefficient category system may be used to complement BI-RADS in clinical decision-making.


Assuntos
Neoplasias da Mama , Meios de Contraste , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Diagnóstico Diferencial , Mama/diagnóstico por imagem , Mama/patologia , Imagem de Difusão por Ressonância Magnética , Imageamento por Ressonância Magnética , Neoplasias da Mama/patologia , Sensibilidade e Especificidade
16.
Eur Radiol ; 33(9): 6213-6225, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37138190

RESUMO

OBJECTIVES: To report mastectomy and reoperation rates in women who had breast MRI for screening (S-MRI subgroup) or diagnostic (D-MRI subgroup) purposes, using multivariable analysis for investigating the role of MRI referral/nonreferral and other covariates in driving surgical outcomes. METHODS: The MIPA observational study enrolled women aged 18-80 years with newly diagnosed breast cancer destined to have surgery as the primary treatment, in 27 centres worldwide. Mastectomy and reoperation rates were compared using non-parametric tests and multivariable analysis. RESULTS: A total of 5828 patients entered analysis, 2763 (47.4%) did not undergo MRI (noMRI subgroup) and 3065 underwent MRI (52.6%); of the latter, 2441/3065 (79.7%) underwent MRI with preoperative intent (P-MRI subgroup), 510/3065 (16.6%) D-MRI, and 114/3065 S-MRI (3.7%). The reoperation rate was 10.5% for S-MRI, 8.2% for D-MRI, and 8.5% for P-MRI, while it was 11.7% for noMRI (p ≤ 0.023 for comparisons with D-MRI and P-MRI). The overall mastectomy rate (first-line mastectomy plus conversions from conserving surgery to mastectomy) was 39.5% for S-MRI, 36.2% for P-MRI, 24.1% for D-MRI, and 18.0% for noMRI. At multivariable analysis, using noMRI as reference, the odds ratios for overall mastectomy were 2.4 (p < 0.001) for S-MRI, 1.0 (p = 0.957) for D-MRI, and 1.9 (p < 0.001) for P-MRI. CONCLUSIONS: Patients from the D-MRI subgroup had the lowest overall mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). This analysis offers an insight into how the initial indication for MRI affects the subsequent surgical treatment of breast cancer. KEY POINTS: • Of 3065 breast MRI examinations, 79.7% were performed with preoperative intent (P-MRI), 16.6% were diagnostic (D-MRI), and 3.7% were screening (S-MRI) examinations. • The D-MRI subgroup had the lowest mastectomy rate (24.1%) among MRI subgroups and the lowest reoperation rate (8.2%) together with P-MRI (8.5%). • The S-MRI subgroup had the highest mastectomy rate (39.5%) which aligns with higher-than-average risk in this subgroup, with a reoperation rate (10.5%) not significantly different to that of all other subgroups.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia , Mastectomia Segmentar , Mama , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios
17.
Invest Radiol ; 58(11): 799-810, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37227137

RESUMO

BACKGROUND: Breast cancer, the most common malignant cancer in women worldwide, is typically diagnosed by x-ray mammography, which is an unpleasant procedure, has low sensitivity in women with dense breasts, and involves ionizing radiation. Breast magnetic resonance imaging (MRI) is the most sensitive imaging modality and works without ionizing radiation, but is currently constrained to the prone imaging position due to suboptimal hardware, therefore hampering the clinical workflow. OBJECTIVES: The aim of this work is to improve image quality in breast MRI, to simplify the clinical workflow, shorten measurement time, and achieve consistency in breast shape with other procedures such as ultrasound, surgery, and radiation therapy. MATERIALS AND METHODS: To this end, we propose "panoramic breast MRI"-an approach combining a wearable radiofrequency coil for 3 T breast MRI (the "BraCoil"), acquisition in the supine position, and a panoramic visualization of the images. We demonstrate the potential of panoramic breast MRI in a pilot study on 12 healthy volunteers and 1 patient, and compare it to the state of the art. RESULTS: With the BraCoil, we demonstrate up to 3-fold signal-to-noise ratio compared with clinical standard coils and acceleration factors up to 6 × 4. Panoramic visualization of supine breast images reduces the number of slices to be viewed by a factor of 2-4. CONCLUSIONS: Panoramic breast MRI allows for high-quality diagnostic imaging and facilitated correlation to other diagnostic and interventional procedures. The developed wearable radiofrequency coil in combination with dedicated image processing has the potential to improve patient comfort while enabling more time-efficient breast MRI compared with clinical coils.


Assuntos
Neoplasias da Mama , Dispositivos Eletrônicos Vestíveis , Feminino , Humanos , Projetos Piloto , Mama/diagnóstico por imagem , Mama/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
18.
Cancers (Basel) ; 15(7)2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37046791

RESUMO

Targeted axillary dissection (TAD) is an axillary staging technique after NACT that involves the removal of biopsy-proven metastatic lymph nodes in addition to sentinel lymph node biopsy (SLNB). This technique avoids the morbidity of traditional axillary lymph node dissection and has shown a lower false-negative rate than SLNB alone. Therefore, marking positive axillary lymph nodes before NACT is critical in order to locate and remove them in the subsequent surgery. Current localization methods include clip placement with intraoperative ultrasound, carbon-suspension liquids, localization wires, radioactive tracer-based localizers, magnetic seeds, radar reflectors, and radiofrequency identification devices. The aim of this paper is to illustrate the management of axillary lymph nodes based on current guidelines and explain the features of axillary lymph node markers, with relative advantages and disadvantages.

19.
BMC Cancer ; 23(1): 281, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36978031

RESUMO

BACKGROUND: Residual fibroglandular breast tissue (RFGT) following a mastectomy has been claimed to be associated with the occurrence of an in-breast local recurrence (IBLR) or new primary tumor (NP). Yet, scientific evidence proving this assumption is lacking. The primary aim of the study was to verify whether RFGT following a mastectomy is a risk factor for an IBLR or NP. METHODS: This retrospective analysis included all patients that underwent a mastectomy and were followed up at the Department of Obstetrics and Gynecology of the Medical University of Vienna between 01.01.2015 and 26.02.2020. RFGT volume (assessed on magnetic resonance imaging) was correlated with the prevalence of an IBLR and a NP. RESULTS: A total of 105 patients (126 breasts) following a therapeutic mastectomy were included. After a mean follow-up of 46.0 months an IBLR had occurred in 17 breasts and a NP in 1 breast. A significant difference in RFGT volume was observed between the disease-free cohort and the subgroup with an IBLR or NP (p = .017). A RFGT volume of ≥ 1153 mm3 increased the risk by the factor 3.57 [95%CI 1.27; 10.03]. CONCLUSIONS: RFGT volume is associated with an increased risk for an IBLR or NP.


Assuntos
Neoplasias da Mama , Mastectomia , Humanos , Feminino , Mastectomia/efeitos adversos , Mastectomia/métodos , Neoplasias da Mama/cirurgia , Estudos Retrospectivos , Mama/diagnóstico por imagem , Mama/cirurgia , Fatores de Risco , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/cirurgia
20.
Diagnostics (Basel) ; 13(4)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36832242

RESUMO

There is limited information about whether the level of enhancement on contrast-enhanced mammography (CEM) can be used to predict malignancy. The purpose of this study was to correlate the level of enhancement with the presence of malignancy and breast cancer (BC) aggressiveness on CEM. This IRB-approved, cross-sectional, retrospective study included consecutive patients examined with CEM for unclear or suspicious findings on mammography or ultrasound. Excluded were examinations performed after biopsy or during neoadjuvant treatment for BC. Three breast radiologists who were blinded to patient data evaluated the images. The enhancement intensity was rated from 0 (no enhancement) to 3 (distinct enhancement). ROC analysis was performed. Sensitivity and negative likelihood ratio (LR-) were calculated after dichotomizing enhancement intensity as negative (0) versus positive (1-3). A total of 156 lesions (93 malignant, 63 benign) in 145 patients (mean age 59 ± 11.6 years) were included. The mean ROC curve was 0.827. Mean sensitivity was 95.4%. Mean LR- was 0.12%. Invasive cancer presented predominantly (61.8%) with distinct enhancement. A lack of enhancement was mainly observed for ductal carcinoma in situ. Stronger enhancement intensity was positively correlated with cancer aggressiveness, but the absence of enhancement should not be used to downgrade suspicious calcifications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...