Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sleep Breath ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662312

RESUMO

PURPOSE: Polysomnography (PSG) may be completed in the home environment (unattended), and when self-applied, allow the collection of data with minimal healthcare worker intervention. Self-applied, unattended PSG in the home environment using Somte PSG V2 (Somte) has not been validated in pregnant women in early to mid-gestation. We undertook a study to evaluate the accuracy of Somte compared to attended PSG. The agreement between apnoea hypopnea index (AHI) and respiratory disturbance index (RDI) scores in Somte and PSG in early to mid-gestation were assessed. METHODS: Pregnant women (≤ 24 weeks gestation) were scheduled for PSG and Somte within a 7-day window, in any order. Somte were self-applied and completed in the home. Somte were scored blinded to PSG result. AHI was the primary outcome of interest, though an AHI ≥ 5 or RDI ≥ 5 on PSG was considered diagnostic of Obstructive Sleep Apnoea (OSA). AHI, RDI, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) was calculated and receiver operating characteristic (ROC) curves were produced. Bland-Altman plots were used to determine agreement. Technical issues occurring during tests were explored. RESULTS: Twenty-four participants successfully completed both tests between March 2021 and January 2023. PSG were completed at around 14.1 weeks' gestation (IQR 13.4, 15.7). The time interval between Somte and PSG was a median of 4 days (IQR 2, 7 (range 1-12)). Five (20.8%) women had OSA on PSG at AHI ≥ 5 and 10 (41.6%) women had OSA on PSG at RDI ≥ 5. Somte and PSG did not differ in the measurement of AHI ((1.8, 1.6, p = 0.09) or RDI (3.3, 3.5), p = 0.73). At AHI ≥ 5, diagnostic test accuracy (area under the ROC curve) of Somte was 0.94, sensitivity 80.0%, specificity 94.7%, PPV and NPV were 80.0% and 94.7% respectively. At RDI ≥ 5, diagnostic test accuracy (area under the ROC curve) was 0.95, sensitivity 60.0%, specificity 93.0% and PPV and NPV were 85.7% and 76.4% respectively. The confidence limits of Bland-Altman plots were 6.37 to - 8.89 at cut off AHI ≥ 5 and 8.89 to - 10.43 at cut off RDI ≥ 5. Somte failed to start in four tests. Technical issues were reported in both Somte (n = 13, 54.2%) and PSG (n = 6, 25.0%). CONCLUSION: Self-applied, unattended Somte may provide an acceptable substitute to attended PSG in the identification of OSA in pregnant women in early to mid-gestation in this small sample but may fail to detect cases of OSA, particularly when using RDI as the diagnostic marker.

2.
Sleep Breath ; 28(3): 1207-1216, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38294625

RESUMO

PURPOSE: The detection of obstructive sleep apnoea (OSA) in pregnant women in early-mid gestation is logistically difficult. Accurate alternates to polysomnography (PSG) in early pregnancy are not well identified. We compared the agreement between Apnealink Air (AL) and existing screening questionnaires to PSG in pregnant women ≤ 24-week gestation. METHODS: Pregnant women (≤ 24-week gestation) underwent AL at home plus attended PSG in any order, completed within 7 days where practicable. AL was manually scored (AL(M)) and automatically scored (AL(A)). An apnoea-hypopnea index (AHI) ≥ 5 was considered diagnostic of OSA and an AHI ≥ 15 considered at least moderate OSA. Diagnostic analysis was undertaken (sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV)) by generating receiver operating characteristic (ROC) curves and an area under the curve (AUC) (95% CI). Bland-Altman plots were used to plot agreement. Screening questionnaires (Epworth sleepiness score (ESS), STOP-BANG, calculated pregnancy-specific screening tool) were compared to PSG. RESULTS: A total of 49 participants successfully completed both tests at around 14-weeks gestation (IQR 12.9, 17.1). The time interval between AL and PSG was a median of 2 days (IQR 1, 5 (range 1-11)). A total of 14 (29%) participants had OSA. The median AHI of AL(A) (3.1(IQR 0.85,4.6)) and AL(M) (IQR2.4(0.65,4.8)) did not differ from PSG (1.7(IQR1.0,6.1)). AL(A) and AL(M) compared to PSG demonstrated diagnostic test accuracy (area under curve (ROC)) of 0.94(95% CI 0.87-1.0) and 0.92(95% CI 0.85-1.0) respectively. Apnealink Air outperformed screening questionnaires tested. CONCLUSION: The findings suggest that Apnealink may provide a substitute to attended PSG identification of OSA in pregnant women in early-mid gestation using both manual and auto-scoring methods.


Assuntos
Polissonografia , Complicações na Gravidez , Apneia Obstrutiva do Sono , Humanos , Feminino , Gravidez , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Complicações na Gravidez/diagnóstico , Inquéritos e Questionários , Segundo Trimestre da Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...