Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38888577

RESUMO

Open surgical repair, often in the form of endarterectomy, is still the gold standard for steno-occlusive disease in the common femoral artery, despite the success of lower-risk endovascular alternatives in other peripheral arterial regions. Stenting in the common femoral artery is not widely adopted due to the proximity of the artery to the mobile hip joint, and the perceived risk this has on the stent structure due to kinking. The purpose of this review was to assess how hip movement contributes to the anatomical and biomechanical challenges proposed in the common femoral artery, and how these challenges impact the hemodynamics with both open surgical and endovascular stent treatments. The findings demonstrated that the common femoral artery is a fixed arterial segment which does not bend or twist as previously perceived. However, high degrees of bending and twisting are evident in the vessels directly proximal and distal to the common femoral artery. Mechanical testing suggests that the latest generation braided Nitinol stents could be well-suited to these challenges. Both endarterectomy and stenting provide good hemodynamic results regarding limb perfusion. However, other hemodynamic parameters, such as wall shear stress, may not be optimized with either modality, increasing the risk of chronic restenosis. As a high proportion of common femoral artery disease extends into the adjacent arterial segments, further research is warranted to ascertain the optimum hemodynamic stent configuration, as a lower-risk alternative to open surgery.

2.
Trials ; 25(1): 214, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528619

RESUMO

BACKGROUND: Endovascular repair of aortic aneurysmal disease is established due to perceived advantages in patient survival, reduced postoperative complications, and shorter hospital lengths of stay. High spatial and contrast resolution 3D CT angiography images are used to plan the procedures and inform device selection and manufacture, but in standard care, the surgery is performed using image-guidance from 2D X-ray fluoroscopy with injection of nephrotoxic contrast material to visualise the blood vessels. This study aims to assess the benefit to patients, practitioners, and the health service of a novel image fusion medical device (Cydar EV), which allows this high-resolution 3D information to be available to operators at the time of surgery. METHODS: The trial is a multi-centre, open label, two-armed randomised controlled clinical trial of 340 patient, randomised 1:1 to either standard treatment in endovascular aneurysm repair or treatment using Cydar EV, a CE-marked medical device comprising of cloud computing, augmented intelligence, and computer vision. The primary outcome is procedural time, with secondary outcomes of procedural efficiency, technical effectiveness, patient outcomes, and cost-effectiveness. Patients with a clinical diagnosis of AAA or TAAA suitable for endovascular repair and able to provide written informed consent will be invited to participate. DISCUSSION: This trial is the first randomised controlled trial evaluating advanced image fusion technology in endovascular aortic surgery and is well placed to evaluate the effect of this technology on patient outcomes and cost to the NHS. TRIAL REGISTRATION: ISRCTN13832085. Dec. 3, 2021.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Análise Custo-Benefício , Computação em Nuvem , Procedimentos Endovasculares/métodos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
3.
J Am Coll Radiol ; 20(5S): S265-S284, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37236748

RESUMO

As the incidence of thoracoabdominal aortic pathology (aneurysm and dissection) rises and the complexity of endovascular and surgical treatment options increases, imaging follow-up of patients remains crucial. Patients with thoracoabdominal aortic pathology without intervention should be monitored carefully for changes in aortic size or morphology that could portend rupture or other complication. Patients who are post endovascular or open surgical aortic repair should undergo follow-up imaging to evaluate for complications, endoleak, or recurrent pathology. Considering the quality of diagnostic data, CT angiography and MR angiography are the preferred imaging modalities for follow-up of thoracoabdominal aortic pathology for most patients. The extent of thoracoabdominal aortic pathology and its potential complications involve multiple regions of the body requiring imaging of the chest, abdomen, and pelvis in most patients. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Aneurisma da Aorta Toracoabdominal , Humanos , Estados Unidos , Seguimentos , Sociedades Médicas , Medicina Baseada em Evidências , Angiografia
4.
J Endovasc Ther ; 30(4): 592-599, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35471131

RESUMO

PURPOSE: Fenestrated endovascular aneurysm repair (fEVAR) is established for the treatment of juxtarenal, pararenal, and thoracoabdominal aortic aneurysms (TAAAs). Bridging stents are used to connect the main body of the stent graft to the aortic branch vessels. Complications related to the bridging stents compromise the durability of the repair and require urgent re-intervention. Here we present the midterm results of the BeGraft stent graft system used for fEVAR. MATERIALS AND METHOD: All consecutive patients treated with fEVAR and the current BeGraft Peripheral Stent Graft between November 2015 and September 2016 were included. RESULTS: Thirty-nine consecutive patients (38 men) were enrolled and 101 BeGraft second-generation stent grafts were implanted. The median aneurysm diameter was 60 mm (54.5-67.0 mm). Aneurysms were juxtarenal and pararenal (19/39, 48.1%), type 4 TAAA (3/39, 7.7%), type 1, 2, and 3 TAAA (7/39, 17.8%), type 5 TAAA (4/39, 10.2%), and 15.4% (6/39) had a type I endoleak following a previous EVAR. Fifty-five BeGrafts were implanted in mesenteric arteries (22 in coeliac trunks, 31 in the superior mesenteric artery, and 2 in a hepatic or splenic artery) and 46 into renal arteries (24 right and 22 left). The renal artery diameters were 5, 6, 7, and 8 mm in 9, 7, 26, and 4 patients, respectively. Mesenteric arteries were exclusively stented with 9 and 10 mm diameter devices. The median follow-up was 33 months (IQ25 17-IQ75 36). During follow-up, 11 patients died (28%) from non-aneurysm-related causes. The overall patency rates for bridging stents were 98% and 97% at 1 and 2 years, respectively, with a freedom from secondary procedure rate on BeGraft stent grafts of 96% (97/101). All events occurred on stents implanted in renal arteries. CONCLUSION: Early favorable outcomes are confirmed during longer term follow-up. Vigilant surveillance is required.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Prótese Vascular , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Resultado do Tratamento , Stents
5.
J Am Coll Radiol ; 19(11S): S364-S373, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36436963

RESUMO

Arterial claudication is a common manifestation of peripheral artery disease. This document focuses on necessary imaging before revascularization for claudication. Appropriate use of ultrasound, invasive arteriography, MR angiography, and CT angiography are discussed. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Doença Arterial Periférica , Sociedades Médicas , Humanos , Medicina Baseada em Evidências , Claudicação Intermitente/diagnóstico por imagem , Angiografia , Doença Arterial Periférica/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea
7.
Ann Vasc Surg ; 75: 86-93, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33823257

RESUMO

BACKGROUND: The benefits of imaging guidance using a new fully automated fusion process (CYDAR) have been demonstrated during endovascular aortic aneurysm repair, but little is known about its use during aorto-iliac occlusive disease endovascular revascularization. The aim of this study was to evaluate the influence of CYDAR image fusion guidance during endovascular treatment of symptomatic aorto-iliac occlusive lesions, compared with control patients treated using standard 2D fluoroscopy alone. METHODS: This is a single-center randomized controlled pilot study that recruited patients undergoing aorto-iliac endovascular revascularization. RESULTS: Between January 2019 and February 2020, 37 patients with symptomatic aorto-iliac lesions were enrolled: 18 were assigned to the fusion group and 19 to the control group. Patients and lesions characteristics were well balanced between both study groups. The technical success of the procedure was 100% in the Fusion group and 94% in the control group. All radiation-related parameters were lower in the fusion compared to the control group, including: median DAP 18.5 Gy.cm2 vs. 21.8 Gy.cm2; Air Kerma 0.10 Gy vs. 0.12 Gy; fluoroscopy dose 4.2 Gy.cm2 vs. 5.1 Gy.cm2; and number of DSA 7.5 vs. 8. The volume of iodinated contrast used was higher in the fusion group: 41 mL vs. 30 mL. The total procedure time was the same in both groups:60 min vs. 60 min. CONCLUSIONS: The results of this pilot study suggest the use of fusion imaging in endovascular treatment of aorto-iliac disease results in reduction in radiation-related measured parameters with no change in procedure time and higher doses of iodinated contrast used. These results need to be further investigated in a larger, adequately powered study.


Assuntos
Doenças da Aorta/terapia , Aortografia , Arteriopatias Oclusivas/terapia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Artéria Ilíaca/diagnóstico por imagem , Radiografia Intervencionista , Idoso , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Automação , Procedimentos Endovasculares/efeitos adversos , Feminino , França , Humanos , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Tempo , Resultado do Tratamento
12.
Eur J Vasc Endovasc Surg ; 57(5): 633-638, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30293887

RESUMO

OBJECTIVES: To evaluate, in patients with acute type B aortic dissection, the results of medical and endovascular treatment in a large single centre experience and to investigate the clinical and imaging features on presentation that relate to poor outcome. METHODS: This was a retrospective analysis of prospectively collected clinical and CT imaging data. Consecutive patients (136) with acute type B aortic dissection were included in the study over an 11 year period. The characteristics of patients receiving endovascular (complicated) or medical treatment (uncomplicated) were compared. Kaplan-Meier estimators were used to estimate cumulative overall survival and survival free of aortic events. Factors associated with overall and aortic event free survival were also explored using Cox proportional hazards models. RESULTS: The mean follow up was 51 months (1-132), during which time 33 deaths and 48 aortic events occurred. At one and five years, overall survival was 94.0% and 74.8%, respectively, and freedom from aortic events was 75.6% and 58.7%. There was no difference in all cause survival and aortic event free survival at one and five years between the patients treated endovascularly and those receiving medical treatment alone. Risk analysis for aortic events demonstrated the maximum size of the proximal entry tear, the maximum thoracic aortic diameter, and the thoracic aortic false lumen maximum diameter to have a significant effect on the incidence of aortic events. CONCLUSIONS: Active management of patients with type B aortic dissection results in good long-term survival even in the presence of features traditionally associated with adverse outcomes. All patients require close lifetime surveillance as aortic events continue to occur during follow up even after endografting.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/tratamento farmacológico , Dissecção Aórtica/patologia , Anti-Hipertensivos/uso terapêutico , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/tratamento farmacológico , Aneurisma da Aorta Torácica/patologia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Intervalo Livre de Progressão , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
14.
JACC Cardiovasc Imaging ; 11(6): 902-919, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29880113

RESUMO

In diagnosing and following patients with acute aortic syndromes and thoracic aortic aneurysms, high-quality imaging of the thoracic aorta is indispensable. Mainstay modalities for thoracic aortic imaging are echocardiography, computed tomographic angiography, and magnetic resonance angiography. For any given clinical scenario, the imaging modality and protocol chosen will have a significant impact on sensitivity and specificity for the aortic diagnosis of concern. Imaging can also provide important ancillary information regarding myocardial performance, aortic valve morphology and function, and end-organ perfusion. Surveillance of patients following thoracic aortic surgery with serial imaging studies can identify complications that may require reintervention, and imaging has played an integral role in development of new surgical and interventional methods. Emerging techniques in thoracic aortic imaging include positron emission tomography, which addresses vessel wall inflammation, and 4-dimensional magnetic resonance angiography, which illustrates flow dynamics.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Imagem Multimodal , Aorta Torácica/fisiopatologia , Doenças da Aorta/fisiopatologia , Doenças da Aorta/terapia , Hemodinâmica , Humanos , Valor Preditivo dos Testes , Prognóstico , Fluxo Sanguíneo Regional
15.
Magn Reson Imaging ; 49: 25-31, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29217492

RESUMO

Hemorrhage and lipid deposits contribute to instability in atherosclerotic plaques. Unstable carotid artery plaques can lead to cerebral ischemic events. While MRI studies have shown the ability to identify plaque components, the identification of hemorrhage and lipids has proven to be problematic. The purpose of this study was to quantitatively evaluate the potential of the MRI fat/water separation method known as iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL) to complement and improve existing methods for the identification of hemorrhage and lipids in carotid artery plaques. Fifteen asymptomatic subjects with 50-79% stenosis of at least one carotid artery were enrolled. Hemorrhage and lipid components within carotid plaques were identified using previously published criteria based on the multiple contrast-weighted (MCW) method (3D Time-of-Flight (3D-TOF), T1-Weighted (T1W) and T2-Weighted (T2W)). The hemorrhage:muscle, lipid:muscle and intra-plaque lipid:hemorrhage signal intensity ratios (SIR) and contrast to noise ratios (CNR) were measured on MCW and compared to IDEAL black-blood images. No differences were found between any of the MCW methods for any of the SIRs measured. The IDEAL Fat images had higher lipid:muscle and lipid/hemorrhage SIRs (p<0.001) compared to IDEAL Water and all MCW image sequence types. The mean values of IDEAL Fat hemorrhage:muscle SIR and CNR were nearly unity (1.1±0.6) and nearly zero (0.1±1.1), respectively. The IDEAL Water imaging was not significantly different than any of the MCW methods for any of the SIRs or for the hemorrhage:muscle CNR of 3D-TOF, while its CNRs were significantly higher than IDEAL Fat lipid:muscle (p<0.05) and lipid:hemorrhage (p<0.001) and all MCW methods (p<0.001). The addition of IDEAL Water and Fat imaging to the MCW method shows potential to improve the identification of hemorrhage and lipid structures in carotid artery plaques.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/metabolismo , Hemorragia/diagnóstico por imagem , Lipídeos/análise , Imageamento por Ressonância Magnética/métodos , Placa Aterosclerótica/diagnóstico por imagem , Idoso , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/metabolismo , Estenose das Carótidas/complicações , Feminino , Hemorragia/complicações , Humanos , Análise dos Mínimos Quadrados , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Placa Aterosclerótica/metabolismo
17.
J Endovasc Ther ; 24(5): 656-660, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28689484

RESUMO

PURPOSE: To report emergent transcatheter aortic valve implantation (TAVI) to treat acute severe aortic regurgitation caused by valve cusp dysfunction following proximal migration of an endograft implanted in the ascending aorta during endovascular arch repair. CASE REPORT: A 65-year-old man had been previously treated with thoracic and fenestrated endografts in a 2-stage procedure for a chronic type B dissection. At 2-year follow-up, aneurysmal evolution of the distal arch led to development of a proximal type Ia endoleak. The patient was deemed unfit for open repair because of severe nonrevascularizable coronary artery disease. A custom-made endograft was designed consisting of a double inner branch arch endograft with a proximal component to reline the ascending aorta to avoid iatrogenic type A dissection. The first component was successfully deployed. However, this device migrated toward the aortic valve when the delivery system of the branch device was advanced through the aortic valve. Aortography and transesophageal echography showed acute aortic regurgitation due to obstruction of the left coronary valve cusp. An emergency bailout TAVI procedure was performed to successfully treat the aortic regurgitation. CONCLUSION: TAVI can be used as a bailout procedure for acute aortic valve dysfunction during endovascular arch or ascending aorta repair.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/etiologia , Substituição da Valva Aórtica Transcateter , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Ecocardiografia Transesofagiana , Endoleak/diagnóstico por imagem , Endoleak/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/fisiopatologia , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
18.
J Endovasc Ther ; 24(4): 534-538, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28602115

RESUMO

PURPOSE: To report early experience with a new endovascular graft developed for aortic arch aneurysm repair in patients unfit for open surgery. CASE REPORT: Three consecutive men (62, 74, and 69 years old) at high risk for open repair were treated for postdissection aortic arch aneurysms using a custom-made 3 inner branched endovascular graft. The 2 proximal branches are antegrade and perfuse the innominate artery and the left common carotid artery; the third branch is retrograde and perfuses the left subclavian artery. The latter is preloaded with a catheter and wire to aid cannulation. Technical success was achieved in each case. The mean procedure time, fluoroscopy duration, and contrast volume were 180 minutes, 35 minutes, and 145 mL, respectively. The perioperative period was uneventful. All branches were patent on 6-month computed tomography and duplex ultrasound imaging. CONCLUSION: This new patient-specific device allows total endovascular revascularization of the supra-aortic trunks during arch repair. These encouraging results support its more widespread use.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Desenho de Prótese , Radiografia Intervencionista , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Grau de Desobstrução Vascular
19.
Ann Vasc Surg ; 44: 158-163, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28546044

RESUMO

BACKGROUND: Prophylactic open surgery is the standard practice in patients with connective tissue and thoracoabdominal aortic aneurysm (TAAA) and aortic arch disease. Branched and fenestrated devices offer a less invasive alternative but there are concerns regarding the durability of the repair and the effect of the stent graft on the fragile aortic wall. The aim of this study is to evaluate mid-term outcomes of fenestrated and/or branched endografting in patients with connective tissue disease. METHODS: All patients with connective tissue disease who underwent TAAA or arch aneurysm repair using a fenestrated and/or branched endograft in a single, high-volume center between 2004 and 2015 were included. Ruptured aneurysms and acute aortic dissections were excluded from this study, but not chronic aortic dissections. RESULTS: In total, 427 (403 pararenal and TAAAs, and 24 arch aneurysms) endovascular interventions were performed during the study period. Of these, 17 patients (4%) (16 TAAAs, 1 arch) had connective tissue disease. All patients were classified as unfit for open repair. The mean age was 51 ± 8 years. Thirteen patients with TAAA were treated with a fenestrated, 1 with a branched, and 2 with a combined fenestrated/branch device. A double inner branch device was used to treat the arch aneurysm. The technical success rate was 100% with no incidence of early mortality, spinal cord ischemia, stroke, or further dissection. Postoperative deterioration in renal function was seen in 3 patients (18.8%) and no hemodialysis was required. The mean follow-up was 3.4 years (0.3-7.4). Aneurysm sac shrinkage was seen in 35% of patients (6/17) and the sac diameter remained stable in 65% of patients (11/17). No sac or sealing zone enlargement was observed in any of the patients and there were no conversions to open repair. Reintervention was required in 1 patient at 2 years for bilateral renal artery occlusion (successful fibrinolysis). One type II endoleak (lumbar) is under surveillance and 1 type III (left renal stent) sealed spontaneously. One patient died at 2 years after the procedure from nonaortic causes (endocarditis). CONCLUSIONS: The favorable mid-term outcomes in this series that demonstrate fenestrated and/or branched endografting should be considered in patients with connective tissue and TAAA and aortic arch disease, which are considered unfit for open surgery. All patients require close lifetime surveillance at a center specializing in aortic surgery, with sufficient experience in both open and endovascular aortic surgery, so that if endovascular treatment failure occurs it can be recognized early and further treatment offered.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Doenças do Tecido Conjuntivo/complicações , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Idoso , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Doenças do Tecido Conjuntivo/diagnóstico , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , França , Hospitais com Alto Volume de Atendimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Cardiovasc Surg (Torino) ; 58(2): 270-277, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28045241

RESUMO

Acute aortic dissection is a challenging disease to manage. Type B aortic dissection has traditionally been divided temporally into acute and chronic cases but more recently this classification has been modified to include a sub-acute phase. Computed tomography is the imaging technique used most frequently in diagnosis and management. Active management of blood pressure is essential and should include beta-blockade unless contraindicated. In-hospital outcomes are generally acceptable in patients with medically managed acute uncomplicated type B aortic dissection, with up to 90% of patients surviving to hospital discharge but by 5 years up to 50% of patients are dead with a significant proportion dying from aortic rupture. The aim of endovascular repair is to treat the complications of the dissection, induce aortic remodeling and false lumen thrombosis and it has been shown to result in good long-term outcomes. Stent graft placement however is associated with an incidence of death, stroke, paraplegia and retrograde type A dissection. Some experts now advocate high intensity imaging in the first 14 days to detect development of complications early in the disease course, with planned elective treatment in the subacute phase.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aortografia/métodos , Doenças Assintomáticas , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Humanos , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...