Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Pediatr Pulmonol ; 59(8): 2131-2140, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38593235

RESUMO

Children who require home mechanical ventilation (HMV) with an artificial airway or invasive mechanical ventilation (HMV) have a possibility of successful weaning due to the potential of compensatory lung growth. Internationally accepted guidelines on how to wean from HMV in children is not available, we summarize the weaning strategies from the literature reviews combined with our 27-year experience in the Pediatric Home Respiratory Care program at the tertiary care center in Thailand. The readiness to wean is considered in patients with hemodynamic stability, having effective cough measured by maximal inspiratory pressure, requiring a fraction of inspired oxygen (FiO2) < 40%, positive end expiratory pressure <5 cmH2O, and acceptable arterial blood gases. The strategies of weaning is start weaning during the daytime while the child is awake and close monitoring is feasible. Disconnect time is gradually increased through naps and sleeping hours. Weaning from the conventional mechanical ventilator to Bilevel PAP or CPAP are optional. Factors affected the successful weaning are mainly the underlying diseases, complications, growth and development, caregivers, and resources. Weaning should be stopped during acute illness or increased work of breathing. The readiness for decannulation could be determined by using the speaking devices, tracheostomy capping, and measurement of end-expiratory pressure. Polysomnography and airway evaluation by bronchoscopy are recommended before decannulation. Weaning when the child is ready is crucial because living with HMV can be challenging and stressful. Failure to remove a tracheostomy when indicated can result in delayed speech, social problems as well as risk for infection.


Assuntos
Respiração Artificial , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Criança , Respiração Artificial/métodos , Serviços de Assistência Domiciliar , Tailândia , Pré-Escolar , Lactente , Insuficiência Respiratória/terapia
2.
JAMA Netw Open ; 6(10): e2337810, 2023 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-37856126

RESUMO

Importance: Although nasal suctioning is the most frequently used supportive management for bronchiolitis, its benefit remains unknown. Objective: To evaluate the effectiveness of enhanced vs minimal nasal suctioning in treating infants with bronchiolitis after discharge from the emergency department (ED). Design, Setting, and Participants: This single-blind, parallel-group, randomized clinical trial was conducted from March 6, 2020, to December 15, 2022, at 4 tertiary-care Canadian pediatric EDs. Participants included otherwise healthy infants aged 1 to 11 months with a diagnosis of bronchiolitis who were discharged home from the ED. Interventions: Participants were randomized to minimal suctioning via bulb or enhanced suctioning via a battery-operated device before feeding for 72 hours. Main Outcomes and Measures: The primary outcome was additional resource use, a composite of unscheduled revisits for bronchiolitis or use of additional suctioning devices for feeding and/or breathing concerns. Secondary outcomes included health care utilization, feeding and sleeping adequacy, and satisfaction. Results: Of 884 screened patients, 352 were excluded for criteria, 79 declined participation, 81 were otherwise excluded, 372 were randomized (185 to the minimal suction group and 187 to the enhanced suction group), and 367 (median [IQR] age, 4 [2-6] months; 221 boys [60.2%]) completed the trial (184 in the minimal suction and 183 in the enhanced suction group). Additional resource use occurred for 68 of 184 minimal suction participants (37.0%) vs 48 of 183 enhanced suction participants (26.2%) (absolute risk difference, 0.11; 95% CI, 0.01 to 0.20; P = .03). Unscheduled revisits occurred for 47 of 184 minimal suction participants (25.5%) vs 40 of 183 enhanced suction participants (21.9%) (absolute risk difference, 0.04; 95% CI, -0.05 to 0.12; P = .46). A total of 33 of 184 parents in the minimal suction group (17.9%) used additional suctioning devices vs 11 of 183 parents in the enhanced suction group (6.0%) (absolute risk difference, 0.12; 95% CI, 0.05 to 0.19; P < .001). No significant between-group differences were observed for all bronchiolitis revisits (absolute risk difference, 0.07; 95% CI, -0.02 to 0.16; P = .15), ED revisits (absolute risk difference, 0.04; 95% CI, -0.03 to 0.12; P = .30), parental care satisfaction (absolute risk difference, -0.02; 95% CI, -0.10 to 0.06; P = .70), and changes from baseline to 72 hours in normal feeding (difference in differences, 0.03; 95% CI, -0.10 to 0.17; P = .62), normal sleeping (difference in differences, 0.05; 95% CI, -0.08 to 0.18; P = .47), or normal parental sleeping (difference in differences, 0.10; 95% CI, -0.02 to 0.23; P = .09). Parents in the minimal suction group were less satisfied with the assigned device (62 of 184 [33.7%]) than parents in the enhanced suction group (145 of 183 [79.2%]) (risk difference, 0.45; 95% CI, 0.36 to 0.54; P < .001). Conclusions and Relevance: Compared with minimal suctioning, enhanced suctioning after ED discharge with bronchiolitis did not alter the disease course because there were no group differences in revisits or feeding and sleeping adequacy. Minimal suctioning resulted in higher use of nonassigned suctioning devices and lower parental satisfaction with the assigned device. Trial Registration: ClinicalTrials.gov Identifier: NCT03361371.


Assuntos
Bronquiolite , Alta do Paciente , Humanos , Lactente , Masculino , Bronquiolite/terapia , Canadá , Serviço Hospitalar de Emergência , Método Simples-Cego , Sucção , Feminino
4.
Eur Respir J ; 62(4)2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37500112

RESUMO

This document updates the 2005 European Respiratory Society (ERS) and American Thoracic Society (ATS) technical standard for the measurement of lung volumes. The 2005 document integrated the recommendations of an ATS/ERS task force with those from an earlier National Heart, Lung, and Blood Institute workshop that led to the publication of background papers between 1995 and 1999 and a consensus workshop report with more in-depth descriptions and discussion. Advancements in hardware and software, new research and emerging approaches have necessitated an update to the 2005 technical standard to guide laboratory directors, physiologists, operators, pulmonologists and manufacturers. Key updates include standardisation of linked spirometry, new equipment quality control and validation recommendations, generalisation of the multiple breath washout concept beyond nitrogen, a new acceptability and grading system with addition of example tracings, and a brief review of imaging and other new techniques to measure lung volumes. Future directions and key research questions are also noted.


Assuntos
Pulmão , Sociedades Médicas , Humanos , Estados Unidos , Pulmão/diagnóstico por imagem , Testes de Função Respiratória/métodos , Espirometria , Medidas de Volume Pulmonar
6.
ERJ Open Res ; 8(1)2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35261912

RESUMO

Coronavirus disease 2019 (COVID-19) has negatively affected the delivery of respiratory diagnostic services across the world due to the potential risk of disease transmission during lung function testing. Community prevalence, reoccurrence of COVID-19 surges and the emergence of different variants of SARS-CoV-2 have impeded attempts to restore services. Finding consensus on how to deliver safe lung function services for both patients attending and for staff performing the tests are of paramount importance. This international statement presents the consensus opinion of 23 experts in the field of lung function and respiratory physiology balanced with evidence from the reviewed literature. It describes a robust roadmap for restoration and continuity of lung function testing services during the COVID-19 pandemic and beyond. Important strategies presented in this consensus statement relate to the patient journey when attending for lung function tests. We discuss appointment preparation, operational and environmental issues, testing room requirements including mitigation strategies for transmission risk, requirement for improved ventilation, maintaining physical distance and use of personal protection equipment. We also provide consensus opinion on precautions relating to specific tests, filters, management of special patient groups and alternative options to testing in hospitals. The pandemic has highlighted how vulnerable lung function services are and forces us to re-think how long-term mitigation strategies can protect our services during this and any possible future pandemic. This statement aspires to address the safety concerns that exist and provide strategies to make lung function tests and the testing environment safer when tests are required.

7.
JAMA Netw Open ; 4(7): e2117542, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34279646

RESUMO

Importance: Despite guidelines recommending administration of intravenous (IV) magnesium sulfate for refractory pediatric asthma, the number of asthma-related hospitalizations has remained stable, and IV magnesium therapy is independently associated with hospitalization. Objective: To examine the association between IV magnesium therapy administered in the emergency department (ED) and subsequent hospitalization among pediatric patients with refractory acute asthma after adjustment for patient-level variables. Design, Setting, and Participants: This post hoc secondary analysis of a double-blind randomized clinical trial of children with acute asthma treated from September 26, 2011, to November 19, 2019, at 7 Canadian tertiary care pediatric EDs was conducted between September and November 2020. In the randomized clinical trial, 816 otherwise healthy children aged 2 to 17 years with Pediatric Respiratory Assessment Measure (PRAM) scores of 5 points or higher after initial therapy with systemic corticosteroids and inhaled albuterol with ipratropium bromide were randomly assigned to 3 nebulized treatments of albuterol plus either magnesium sulfate or 5.5% saline placebo. Exposures: Intravenous magnesium sulfate therapy (40-75 mg/kg). Main Outcomes and Measures: The association between IV magnesium therapy in the ED and subsequent hospitalization for asthma was assessed using multivariable logistic regression analysis. Analyses were adjusted for year epoch at enrollment, receipt of IV magnesium, PRAM score after initial therapy and at ED disposition, age, sex, duration of respiratory distress, previous intensive care unit admission for asthma, hospitalizations for asthma within the past year, atopy, and receipt of oral corticosteroids within 48 hours before arrival in the ED, nebulized magnesium, and additional albuterol after inhaled magnesium or placebo, with site as a random effect. Results: Among the 816 participants, the median age was 5 years (interquartile range, 3-7 years), 517 (63.4%) were boys, and 364 (44.6%) were hospitalized. A total of 215 children (26.3%) received IV magnesium, and 190 (88.4%) of these children were hospitalized compared with 174 of 601 children (29.0%) who did not receive IV magnesium. Multivariable factors associated with hospitalization were IV magnesium receipt from 2011 to 2016 (odds ratio [OR], 22.67; 95% CI, 6.26-82.06; P < .001) and from 2017 to 2019 (OR, 4.19; 95% CI, 1.99-8.86; P < .001), use of additional albuterol (OR, 5.94; 95% CI, 3.52-10.01; P < .001), and increase in PRAM score at disposition (per 1-U increase: OR, 2.24; 95% CI, 1.89-2.65; P < .001). In children with a disposition PRAM score of 3 or lower, receipt of IV magnesium therapy was associated with hospitalization (OR, 8.52; 95% CI, 2.96-24.41; P < .001). Conclusions and Relevance: After adjustment for patient-level characteristics, receipt of IV magnesium therapy after initial asthma treatment in the ED was associated with subsequent hospitalization. This association also existed among children with mild asthma at ED disposition. Evidence of a benefit of IV magnesium regarding hospitalization may clarify its use in the treatment of refractory pediatric asthma. Trial registration: ClinicalTrials.gov: NCT01429415.


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Serviço Hospitalar de Emergência/estatística & dados numéricos , Hospitalização/estatística & dados numéricos , Sulfato de Magnésio/administração & dosagem , Doença Aguda , Administração por Inalação , Administração Intravenosa , Adolescente , Albuterol/administração & dosagem , Canadá , Criança , Pré-Escolar , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Humanos , Masculino , Resultado do Tratamento
8.
Front Bioeng Biotechnol ; 8: 589782, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33282850

RESUMO

Aerosol sizing is generally measured at ambient air but human airways have different temperature (37°C) and relative humidity (100%) which can affect particle size in airways and consequently deposition prediction. This work aimed to develop and evaluate a new method using cascade impactor to measure particle size at human physiological temperature and humidity (HPTH) taking into account ambient air conditions. A heated and humidified trachea was built and a cascade impactor was heated to 37°C and humidified inside. Four medical aerosols [jet nebulizer, mesh nebulizer, Presurized Metered Dose Inhaler (pMDI), and Dry Powder Inhaler (DPI)] under ambient conditions and at HPTH were tested. MMAD was lower at HPTH for the two nebulizers; it was similar at ambient conditions and HPTH for pMDI, and the mass of particles smaller than 5 µm decreased for DPI at HPTH (51.9 vs. 82.8 µg/puff). In conclusion, we developed a new method to measure particle size at HPTH affecting deposition prediction with relevance. In vivo studies are required to evaluate the interest of this new model to improve the precision of deposition prediction.

9.
JAMA ; 324(20): 2038-2047, 2020 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-33231663

RESUMO

Importance: While intravenous magnesium decreases hospitalizations in refractory pediatric acute asthma, it is variably used because of invasiveness and safety concerns. The benefit of nebulized magnesium to prevent hospitalization is unknown. Objective: To evaluate the effectiveness of nebulized magnesium in children with acute asthma remaining in moderate or severe respiratory distress after initial therapy. Design, Setting, and Participants: A randomized double-blind parallel-group clinical trial from September 26, 2011, to November 19, 2019, in 7 tertiary-care pediatric emergency departments in Canada. The participants were otherwise healthy children aged 2 to 17 years with moderate to severe asthma defined by a Pediatric Respiratory Assessment Measure (PRAM) score of 5 or greater (on a 12-point scale) after a 1-hour treatment with an oral corticosteroid and 3 inhaled albuterol and ipratropium treatments. Of 5846 screened patients, 4332 were excluded for criteria, 273 declined participation, 423 otherwise excluded, 818 randomized, and 816 analyzed. Interventions: Participants were randomized to 3 nebulized albuterol treatments with either magnesium sulfate (n = 410) or 5.5% saline placebo (n = 408). Main Outcomes and Measures: The primary outcome was hospitalization for asthma within 24 hours. Secondary outcomes included PRAM score; respiratory rate; oxygen saturation at 60, 120, 180, and 240 minutes; blood pressure at 20, 40, 60, 120, 180, and 240 minutes; and albuterol treatments within 240 minutes. Results: Among 818 randomized patients (median age, 5 years; 63% males), 816 completed the trial (409 received magnesium; 407, placebo). A total of 178 of the 409 children who received magnesium (43.5%) were hospitalized vs 194 of the 407 who received placebo (47.7%) (difference, -4.2%; absolute risk difference 95% [exact] CI, -11% to 2.8%]; P = .26). There were no significant between-group differences in changes from baseline to 240 minutes in PRAM score (difference of changes, 0.14 points [95% CI, -0.23 to 0.50]; P = .46); respiratory rate (0.17 breaths/min [95% CI, -1.32 to 1.67]; P = .82); oxygen saturation (-0.04% [95% CI, -0.53% to 0.46%]; P = .88); systolic blood pressure (0.78 mm Hg [95% CI, -1.48 to 3.03]; P = .50); or mean number of additional albuterol treatments (magnesium: 1.49, placebo: 1.59; risk ratio, 0.94 [95% CI, 0.79 to 1.11]; P = .47). Nausea/vomiting or sore throat/nose occurred in 17 of the 409 children who received magnesium (4%) and 5 of the 407 who received placebo (1%). Conclusions and Relevance: Among children with refractory acute asthma in the emergency department, nebulized magnesium with albuterol, compared with placebo with albuterol, did not significantly decrease the hospitalization rate for asthma within 24 hours. The findings do not support use of nebulized magnesium with albuterol among children with refractory acute asthma. Trial Registration: ClinicalTrials.gov Identifier: NCT01429415.


Assuntos
Albuterol/uso terapêutico , Asma/tratamento farmacológico , Broncodilatadores/uso terapêutico , Magnésio/uso terapêutico , Doença Aguda , Administração por Inalação , Adolescente , Corticosteroides/uso terapêutico , Criança , Pré-Escolar , Método Duplo-Cego , Quimioterapia Combinada , Serviço Hospitalar de Emergência , Feminino , Hospitalização , Humanos , Ipratrópio/uso terapêutico , Magnésio/efeitos adversos , Masculino , Nebulizadores e Vaporizadores , Falha de Tratamento
10.
Ther Adv Gastrointest Endosc ; 12: 2631774519843401, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31192315

RESUMO

BACKGROUND AND AIM: The BreathID ® Hp urea breath test provides several advantages over other 13C breath analyzers for the detection of Helicobacter pylori. We evaluated the sensitivity and specificity of a new BreathID ® Hp Lab System (Exalenz Bioscience Ltd, Israel), a 13C-urea breath test system using breath sampling bags that facilitates multiple testing in a multicenter international clinical study. METHODS: A total of 257 subjects with evaluable results for urea breath test, rapid urease test, and histology were enrolled into two study groups: 189 naïve subjects were included in the pre-therapy group, and 68 subjects comprised the post-eradication therapy group. Analytical studies were conducted to evaluate the stability, reproducibility, and repeatability of the 13C-urea breath test results using a delta over baseline cut-off value of 5. RESULTS: Among the pre-therapy subjects evaluated with the composite results from the rapid urease test and histology/immunohistochemistry, 176 results matched those of the urea breath test, resulting in an overall agreement of 98.3% with a sensitivity of 100% and specificity of 97.9%. In the post-eradication therapy cohort, the overall agreement between the urea breath test and the biopsy diagnosis was 98.5%; the sensitivity of the urea breath test in this cohort was 92.3% and the specificity was 100%. There was uniformly high overall reproducibility (99.48%) of the test results over different batches of breath sample bags, when analyzed on different days and under different storage conditions, showing stability of the breath samples in the breath collection bags. CONCLUSION: The BreathID ® Hp Lab System is a highly accurate and dependable method for the diagnosis of H. pylori infection.

12.
Eur Respir J ; 52(5)2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30361249

RESUMO

Recently, this international task force reported the general considerations for bronchial challenge testing and the performance of the methacholine challenge test, a "direct" airway challenge test. Here, the task force provides an updated description of the pathophysiology and the methods to conduct indirect challenge tests. Because indirect challenge tests trigger airway narrowing through the activation of endogenous pathways that are involved in asthma, indirect challenge tests tend to be specific for asthma and reveal much about the biology of asthma, but may be less sensitive than direct tests for the detection of airway hyperresponsiveness. We provide recommendations for the conduct and interpretation of hyperpnoea challenge tests such as dry air exercise challenge and eucapnic voluntary hyperpnoea that provide a single strong stimulus for airway narrowing. This technical standard expands the recommendations to additional indirect tests such as hypertonic saline, mannitol and adenosine challenge that are incremental tests, but still retain characteristics of other indirect challenges. Assessment of airway hyperresponsiveness, with direct and indirect tests, are valuable tools to understand and to monitor airway function and to characterise the underlying asthma phenotype to guide therapy. The tests should be interpreted within the context of the clinical features of asthma.


Assuntos
Asma/diagnóstico , Testes de Provocação Brônquica/métodos , Testes de Provocação Brônquica/normas , Adenosina , Comitês Consultivos , Europa (Continente) , Humanos , Manitol , Cloreto de Metacolina , Hipersensibilidade Respiratória/diagnóstico , Sociedades Médicas
14.
Chest ; 154(1): 77-83, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29684318

RESUMO

BACKGROUND: Tidal volumes standardized to predicted body weight are recommended for adult mechanical ventilation, but children are frequently ventilated by using measured body weight. The goal of this study was to examine the difference in FVC (in milliliters per kilogram [mL/kg]) by using measured body weight compared with predicted body weight in children. METHODS: This retrospective analysis included outpatient pulmonary function tests (PFTs) from two datasets. Dataset one included 6- to 19-year-old patients undergoing PFTs from the nationally representative Canadian Health Measures Survey. Dataset two included 6- to 20-year-old patients undergoing PFTs at a freestanding children's hospital. FVC mL/kg values were analyzed against BMI z scores to show changes in FVC vs BMI between measured and predicted weight. RESULTS: Dataset one included 5,394 PFTs from the Canadian survey. FVC from measured weight decreased as the BMI z score group increased. The median FVC from measured weight was 81.4 mL/kg in the lowest BMI z score group and 51.7 mL/kg in the highest BMI z score group. FVC from predicted weight increased slightly with increasing BMI z score group. Dataset two included 8,472 patient PFTs from clinical measurement. A decline in median FVC from measured weight (from 69.4 to 37.6 mL/kg) as BMI z score group increased was also seen. CONCLUSIONS: FVC differs significantly when standardizing to measured weight vs predicted weight. Obese children have lung volumes reflecting their predicted body weight from height. Children with low or normal BMI have lung volumes reflecting measured body weight. These findings suggest that targeting tidal volume by using the lower of measured and predicted body weights would be the most lung-protective strategy.


Assuntos
Índice de Massa Corporal , Volume Expiratório Forçado/fisiologia , Pulmão/fisiopatologia , Pacientes Ambulatoriais , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Volume de Ventilação Pulmonar/fisiologia , Adolescente , Criança , Feminino , Seguimentos , Humanos , Masculino , Insuficiência Respiratória/fisiopatologia , Estudos Retrospectivos , Espirometria , Capacidade Vital/fisiologia , Adulto Jovem
16.
Hum Gene Ther ; 29(6): 643-652, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29320887

RESUMO

A major challenge in developing gene-based therapies for airway diseases such as cystic fibrosis (CF) is sustaining therapeutic levels of transgene expression over time. This is largely due to airway epithelial cell turnover and the host immunogenicity to gene delivery vectors. Modern gene editing tools and delivery vehicles hold great potential for overcoming this challenge. There is currently not much known about how to deliver genes into airway stem cells, of which basal cells are the major type in human airways. In this study, helper-dependent adenoviral (HD-Ad) vectors were delivered to mouse and pig airways via intranasal delivery, and direct bronchoscopic instillation, respectively. Vector transduction was assessed by immunostaining of lung tissue sections, which revealed that airway basal cells of mice and pigs can be targeted in vivo. In addition, efficient transduction of primary human airway basal cells was verified with an HD-Ad vector expressing green fluorescent protein. Furthermore, we successfully delivered the human CFTR gene to airway basal cells from CF patients, and demonstrated restoration of CFTR channel activity following cell differentiation in air-liquid interface culture. Our results provide a strong rationale for utilizing HD-Ad vectors to target airway basal cells for permanent gene correction of genetic airway diseases.


Assuntos
Adenoviridae/genética , Terapia Genética , Vetores Genéticos/metabolismo , Vírus Auxiliares/genética , Pulmão/patologia , Transdução Genética , Animais , Células Cultivadas , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Feminino , Camundongos Endogâmicos C57BL , Células-Tronco/metabolismo , Suínos
17.
Am J Respir Crit Care Med ; 196(11): 1463-1472, 2017 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29192835

RESUMO

BACKGROUND: The American Thoracic Society committee on Proficiency Standards for Pulmonary Function Laboratories has recognized the need for a standardized reporting format for pulmonary function tests. Although prior documents have offered guidance on the reporting of test data, there is considerable variability in how these results are presented to end users, leading to potential confusion and miscommunication. METHODS: A project task force, consisting of the committee as a whole, was approved to develop a new Technical Standard on reporting pulmonary function test results. Three working groups addressed the presentation format, the reference data supporting interpretation of results, and a system for grading quality of test efforts. Each group reviewed relevant literature and wrote drafts that were merged into the final document. RESULTS: This document presents a reporting format in test-specific units for spirometry, lung volumes, and diffusing capacity that can be assembled into a report appropriate for a laboratory's practice. Recommended reference sources are updated with data for spirometry and diffusing capacity published since prior documents. A grading system is presented to encourage uniformity in the important function of test quality assessment. CONCLUSIONS: The committee believes that wide adoption of these formats and their underlying principles by equipment manufacturers and pulmonary function laboratories can improve the interpretation, communication, and understanding of test results.


Assuntos
Pulmão/fisiopatologia , Projetos de Pesquisa/normas , Testes de Função Respiratória/normas , Comitês Consultivos , Humanos , Sociedades Médicas , Estados Unidos
18.
Eur Respir J ; 49(5)2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28461290

RESUMO

This international task force report updates general considerations for bronchial challenge testing and the performance of the methacholine challenge test. There are notable changes from prior recommendations in order to accommodate newer delivery devices. Rather than basing the test result upon a methacholine concentration (provocative concentration (PC20) causing a 20% fall in forced expiratory volume in 1 s (FEV1)), the new recommendations base the result upon the delivered dose of methacholine causing a 20% fall in FEV1 (provocative dose (PD20)). This end-point allows comparable results from different devices or protocols, thus any suitable nebuliser or dosimeter may be used, so long as the delivery characteristics are known. Inhalation may be by tidal breathing using a breath-actuated or continuous nebuliser for 1 min (or more), or by a dosimeter with a suitable breath count. Tests requiring maximal inhalations to total lung capacity are not recommended because the bronchoprotective effect of a deep breath reduces the sensitivity of the test.


Assuntos
Testes de Provocação Brônquica/normas , Cloreto de Metacolina , Administração por Inalação , Asma/fisiopatologia , Hiper-Reatividade Brônquica/fisiopatologia , Testes de Provocação Brônquica/métodos , Relação Dose-Resposta a Droga , Europa (Continente) , Volume Expiratório Forçado/efeitos dos fármacos , Humanos , Nebulizadores e Vaporizadores , Guias de Prática Clínica como Assunto , Sociedades Médicas , Capacidade Pulmonar Total/efeitos dos fármacos
20.
Trials ; 17(1): 261, 2016 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-27220675

RESUMO

BACKGROUND: Up to 30 % of children with acute asthma are refractory to initial therapy, and 84 % of this subpopulation needs hospitalization. Finding safe, noninvasive, and effective strategies to treat this high-risk group would substantially decrease hospitalizations, healthcare costs, and the psycho-social burden of the disease. Whereas intravenous magnesium (Mg) is effective in severe refractory asthma, its use is sporadic due to safety concerns, with the main treatment goal being to prevent intensive care unit admission. In contrast, nebulized Mg is noninvasive, allows higher pulmonary drug concentrations, and has a much higher safety potential due to the lower rate of systemic delivery. Previous studies of inhaled Mg show disparate results due to the use of unknown/inefficient delivery methods and other methodological flaws. METHODS/DESIGN: The study is a randomized double-blind controlled trial in seven Canadian pediatric Emergency Departments (two-center pilot 2011 to 2014, Canada-wide November 2014 to December 2017). The trial will include 816 otherwise healthy children who are 2 to 17 years old, having had at least one previous wheezing episode, have received systemic corticosteroids, and have a Pediatric Respiratory Assessment Measure (PRAM) ≥ 5 points after three salbutamol and ipratropium treatments for a current acute asthma exacerbation. Eligible consenting children will receive three experimental treatments of nebulized salbutamol with either 600 mg of Mg sulfate or placebo 20 min apart, using an Aeroneb Go nebulizer, which has been shown to maximize pulmonary delivery while maintaining safety. The primary outcome is hospitalization within 24 h of the start of the experimental therapy for persistent respiratory distress or supplemental oxygen. Secondary outcomes include all-cause hospitalization within 24 h, PRAM, vital signs, number of bronchodilator treatments by 240 min, and the association between the difference in the primary outcome between the groups, age, gender, baseline PRAM, atopy, and "viral induced wheeze" phenotype (Fig. 1). DISCUSSION: If effective, inhaled Mg may represent an effective strategy to minimize morbidity in pediatric refractory acute asthma. Unlike previous works, this trial targets nonresponders to optimized initial therapy who are the most likely to benefit from inhaled Mg. Future dissemination of results will include knowledge translation, incorporation into a Cochrane Review, presentation at scientific meetings, and a peer-reviewed publication. TRIAL REGISTRATION: NCTO1429415 , registered 2 September 2011.


Assuntos
Asma/tratamento farmacológico , Protocolos Clínicos , Magnésio/administração & dosagem , Administração por Inalação , Adolescente , Criança , Pré-Escolar , Método Duplo-Cego , Humanos , Magnésio/efeitos adversos , Avaliação de Resultados em Cuidados de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...