Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Brain Sci ; 10(5)2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32397275

RESUMO

While we are still learning more about COVID-19, caused by the novel SARS-CoV-2 virus, finding alternative and already available methods to reduce the risk and severity of the disease is paramount. One such option is vitamin D, in the form of vitamin D3 (cholecalciferol) supplementation, due to its potential antiviral properties. It has become apparent that older individuals have a greater risk of developing severe COVID-19, and compared to younger adults, the elderly have lower levels of vitamin D due to a variety of biological and behavioral factors. Older adults are also more likely to be diagnosed with Parkinson's disease (PD), with advanced age being the single greatest risk factor. In addition to its immune-system-modulating effects, it has been suggested that vitamin D supplementation plays a role in slowing PD progression and improving PD-related quality of life. We completed a review of the literature to determine the relationship between vitamin D, PD, and COVID-19. We concluded that the daily supplementation of 2000-5000 IU/day of vitamin D3 in older adults with PD has the potential to slow the progression of PD while also potentially offering additional protection against COVID-19.

2.
Anal Chem ; 74(9): 2190-7, 2002 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-12033326

RESUMO

Current strategies for cell-based screening generally focus on the development of highly specific assays, which require an understanding of the nature of the signaling molecules and cellular pathways involved. In contrast, changes in temperature of cells provides a measure of altered cellular metabolism that is not stimulus specific and hence could have widespread applications in cell-based screening of receptor agonists and antagonists, as well as in the assessment of toxicity of new lead compounds. Consequently, we have developed a micromachined nanocalorimetric biological sensor using a small number of isolated living cells integrated within a subnanoliter format, which is capable of detecting 13 nW of generated power from the cells, upon exposure to a chemical or pharmaceutical stimulus. The sensor comprises a 10-junction gold and nickel thermopile, integrated on a silicon chip which was back-etched to span a 800-nm-thick membrane of silicon nitride. The thin-film membrane, which supported the sensing junctions of the thermoelectric transducer, gave the system a temperature resolution of 0.125 mK, a low heat capacity of 1.2 nJ mK(-1), and a rapid (unfiltered) response time of 12 ms. The application of the system in ultra-low-volume cell-based assays could provide a rapid endogenous screen. It offers important additional advantages over existing methods in that it is generic in nature, it does not require the use of recombinant cell lines or of detailed assay development, and finally, it can enable the use of primary cell lines or tissue biopsies.


Assuntos
Varredura Diferencial de Calorimetria/instrumentação , Metabolismo , Adipócitos/metabolismo , Animais , Varredura Diferencial de Calorimetria/métodos , Desenho de Equipamento , Temperatura Alta , Masculino , Camundongos , Microquímica/instrumentação , Mitocôndrias Hepáticas/metabolismo , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Ratos , Transdutores
3.
Anal Chem ; 74(4): 908-14, 2002 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-11866072

RESUMO

The fabrication of microelectrodes integrated within ultra-low-volume microtiter chambers for the amperometric determination of metabolites continues to be of interest in the subject of single-cell and high-throughput screening. The microsystem described in this paper consists of a two-microelectrode sensor with a microfluidic dispensation technology, which is able to deliver both very low titers (6.5 pL) and single heart cells into a low-volume microphotoelectrochemical cell. Devices were fabricated using photolithography and liftoff giving reproducible sensors integrated within high aspect ratio titer chambers (with a volume of 360 pL), made of the photoepoxy SU8. In this paper, the determination of lactate was optimized using an enzyme-linked assay based upon lactate oxidase, involving the amperometric determination of hydrogen peroxide at +640 mV versus an internal Ag/AgCl pseudoreference. The microsystem (including the microfluidic dispensers and structures as well as the microsensor) was subsequently used to measure the lactate content of single heart cells. Dynamic electrochemical measurements of lactate during cell permeabilization are presented. We also show the use of respiratory uncouplers to simulate ischemia in the single myocyte and show that, as expected, the rate of lactate production from the hypoxic heart cell is greater than that within the normoxic healthy myocyte.


Assuntos
Ácido Láctico/análise , Miocárdio/química , Miocárdio/citologia , Indicadores e Reagentes , Lipoxigenase/química , Metais/química , Microeletrodos , Nanotecnologia
4.
IEEE Trans Nanobioscience ; 1(1): 29-36, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16689219

RESUMO

A nanocalorimetric suspended membrane sensor for pL volumes of aqueous media was fabricated by bulk silicon micromachining using anisotropic wet etching and photo and electron beam lithographic techniques. A high-temperature sensitivity of 125 microK and a rapid unfiltered time constant of 12 ms have been achieved by integrating a miniaturized reaction vessel of 0.7-nL volume on a 800-nm-thick and 300 x 300- microm2-large silicon nitride membrane, thermally insulated from the surrounding bulk silicon. The combination of a ten-junction gold and nickel thermoelectric sensor with an integrated ultralow noise preamplifier has enabled the resolution of 15-nW power in a single measurement, a result confirmed by electrical calibration. The combination of a high sensitivity and rapid response time is a consequence of miniaturization. The choice of gold and nickel as sensor material provided the maximum thermal sensitivity in the context of ease of fabrication and cost. The nanocalorimetric sensor has the potential for integration in an ultralow-volume high-density array format for the characterization of processes in which there is an exchange of heat.


Assuntos
Técnicas Biossensoriais/instrumentação , Calorimetria/instrumentação , Membranas Artificiais , Microquímica/instrumentação , Microfluídica/instrumentação , Nanotecnologia/instrumentação , Termografia/instrumentação , Técnicas Biossensoriais/métodos , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Microfluídica/métodos , Termografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...