Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Cancers (Basel) ; 16(13)2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-39001374

RESUMO

The initial favorable efficacy and safety profile for Alpha DaRT have been demonstrated (NCT04377360); however, the longer-term safety and durability of the treatment are unknown. This pooled analysis of four prospective trials evaluated the long-term safety and efficacy of Alpha DaRT for the treatment of head and neck or skin tumors. A total of 81 lesions in 71 patients were treated across six international institutions, with a median follow-up of 14.1 months (range: 2-51 months). Alpha DaRT sources were delivered via a percutaneous interstitial technique and placed to irradiate the tumor volume with the margin. The sources were removed two to three weeks following implantation. A complete response was observed in 89% of treated lesions (n = 72) and a partial response in 10% (n = 8). The two-year actuarial local recurrence-free survival was 77% [95% CI 63-87]. Variables, including recurrent versus non-recurrent lesions, baseline tumor size, or histology, did not impact long-term outcomes. Twenty-seven percent of patients developed related acute grade 2 or higher toxicities, which resolved with conservative measures. No grade 2 or higher late toxicities were observed. These data support the favorable safety profile of Alpha DaRT, which is currently being explored in a pivotal US trial.

2.
Med Phys ; 51(6): 3822-3849, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38648857

RESUMO

Use of magnetic resonance (MR) imaging in radiation therapy has increased substantially in recent years as more radiotherapy centers are having MR simulators installed, requesting more time on clinical diagnostic MR systems, or even treating with combination MR linear accelerator (MR-linac) systems. With this increased use, to ensure the most accurate integration of images into radiotherapy (RT), RT immobilization devices and accessories must be able to be used safely in the MR environment and produce minimal perturbations. The determination of the safety profile and considerations often falls to the medical physicist or other support staff members who at a minimum should be a Level 2 personnel as per the ACR. The purpose of this guidance document will be to help guide the user in making determinations on MR Safety labeling (i.e., MR Safe, Conditional, or Unsafe) including standard testing, and verification of image quality, when using RT immobilization devices and accessories in an MR environment.


Assuntos
Imobilização , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/instrumentação , Humanos , Imobilização/instrumentação , Radioterapia Guiada por Imagem/instrumentação
3.
Med Phys ; 51(3): 2263-2276, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37878762

RESUMO

BACKGROUND: Diffusing alpha-emitters Radiation Therapy ("DaRT") is a promising new modality for the treatment of solid tumors. Interstitial sources containing 224 Ra are inserted into the tumor, producing alpha particles via the decay of 224 Ra and its daughters. The alpha particles are able to produce a "kill region" of several mm due to the diffusion of the alpha-emitting atoms. The Diffusion-Leakage (D-L) model has been proposed to describe the movement of the alpha-emitters used in DaRT in tumor tissue. PURPOSE: To date, estimating the dose delivered under the D-L model has been accomplished with numerical solutions based on finite difference methods, namely DART1D and DART2D, as well as with asymptotic expressions for the long time limit. The aim of this work is to develop a flexible method of finite elements for solving the D-L model and to validate prior solutions of the D-L model. METHODS: We develop a two-dimensional finite element solution to the D-L model implemented using the FEniCS software library. Our approach solves the variational formulation of the D-L equations on an unstructured mesh of triangular Lagrangian elements. We calculate the local dose in the mid- and axial planes of the source and validate our results against the one- and two-dimensional solutions obtained using the previously proposed numerical scheme, DART1D and DART2D. We use our model to estimate the change in dose in the source midplane as a function of the physical parameters used in the D-L model. RESULTS: The local dose at the end of a 30 day treatment period estimated by our numerical method differs from DART1D and DART2D by less than 1% in the source midplane and less than 3% along the source axis over clinically relevant distances, with the largest discrepancies in high gradient areas where the Finite Element Method (FEM) mesh has a higher element density. We find that within current experimentally estimated ranges for D-L model parameters, the dose in the source midplane at a distance of 2 mm can vary by over a factor of 3. CONCLUSIONS: The 2D finite element model reproduces the calculated dose obtained with DART1D and DART2D under the assumptions D-L model. The variation in predicted dose within current experimental ranges for model parameters suggests the necessity of further studies to better determine their statistical distributions. Finally, the FEM model can be used to calculate dose from DaRT in a variety of realistic 2D geometries beyond the D-L model.


Assuntos
Braquiterapia , Neoplasias , Humanos , Análise de Elementos Finitos , Partículas alfa/uso terapêutico , Software , Braquiterapia/métodos
4.
JAMA Netw Open ; 6(5): e2312824, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37166798

RESUMO

Importance: Patients with recurrent or unresectable skin cancers have limited treatment options. Diffusing alpha-emitter radiation therapy (DaRT), a novel solid tumor management strategy using alpha-particle interstitial brachytherapy, may address this challenge. Objective: To evaluate the feasibility and safety of using DaRT to manage recurrent or unresectable skin cancers. Design, Setting, and Participants: This prospective cohort study of patients who received a 2-week to 3-week treatment course and were followed up for 24 weeks after treatment during 2021 and 2022 at 2 sites in the US. Patients with malignant skin tumors or soft tissue tumors were recruited if they had limited treatment options for tumors recurrent after prior surgery or external beam radiotherapy or unresectable tumors. Intervention: Patients underwent DaRT to deliver a physical dose of 10 Gy (equivalent weighted dose of 200 CGE) to the tumor. Main Outcomes and Measures: Feasibility of the DaRT procedure was evaluated based on the ability of investigators to successfully deliver radiation to the tumor. Patients were followed up for adverse events (AEs) for 24 weeks and for tumor response by physicians' physical examination and imaging 12 weeks after device removal. Results: This study included 10 participants with recurrent or unresectable skin cancer (median [IQR] age, 72 [68-75] years; 6 males [60%]; 4 females [40%]). Six patients (60%) had recurrent disease, and 4 (40%) had tumors that were deemed unresectable. Tumors were located on the nose, chin, eyelid, scalp, neck, trunk, and extremities. Median (range) tumor volume before treatment was 2.1 cm3 (0.65-12.65 cm3). The mean (SD) prescription dose coverage of the gross tumor volume was 91% (2.8%) with all tumors having coverage of 85% or more. No device-related grade 3 AEs were noted. Common AEs were grade 1 to 2 erythema, edema, and pruritus. At 12 weeks following treatment, there was a 100% complete response rate. Nine of 10 complete responses (90%) were confirmed by CT imaging. Conclusions and Relevance: This cohort study suggests the feasibility and preliminary safety of DaRT in the management of recurrent or unresectable skin cancers. The favorable safety profile and high response rates are promising. A US trial for marketing approval based on this pilot study is under way. Trial Registration: ClinicalTrials.gov Identifier: NCT04377360.


Assuntos
Braquiterapia , Neoplasias Cutâneas , Masculino , Feminino , Humanos , Idoso , Braquiterapia/efeitos adversos , Estudos de Coortes , Estudos Prospectivos , Projetos Piloto , Estudos de Viabilidade , Neoplasias Cutâneas/radioterapia
5.
J Appl Clin Med Phys ; 24(3): e13829, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36808798

RESUMO

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and professional practice of medical physics. The AAPM has more than 8000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines (MPPGs) will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: (1) Must and must not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. (2) Should and should not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee April 28, 2022.


Assuntos
Braquiterapia , Radioterapia (Especialidade) , Humanos , Estados Unidos , Física Médica/educação , Sociedades
6.
Int J Radiat Oncol Biol Phys ; 116(3): 544-550, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586493

RESUMO

PURPOSE: Keratinocyte carcinomas are amenable to many treatments, including radiation therapy (RT). Electronic skin surface brachytherapy (ESSB) enables the precise delivery of radiation without radioisotopes. In this prospective multicenter clinical trial, we characterized early outcomes of ESSB prospectively through both patient- and clinician-reported measures. To corroborate the cosmesis observations, we also assessed patient-reported quality of life (QoL) and adverse events. METHODS AND MATERIALS: Patients ≥60 years old with stage T1N0M0 keratinocyte carcinoma were treated with ESSB. At 2-, 6-, and 12-weeks post-treatment, cosmesis from ESSB was assessed by both the patient and a clinician study investigator as either "good," "fair," or "bad." The Skindex-16 and the Skin Cancer Index (SCI) were used to assess patient QoL before and after treatment. Adverse events were assessed using the Common Toxicity Criteria for Adverse Events, version 4.0. RESULTS: Cosmesis and QoL were collected at 97% (99/102) of possible patient follow-up times. By 12 weeks post-treatment, 93.9% (31/33) of patient-reported and 96.9% (31/32) of clinician-reported cosmesis outcomes were "good." Compared with baseline, total Skindex-16 score significantly deteriorated at 2 weeks post-treatment (10.5 vs 24.5, P <.001), but significantly improved at 6 weeks (10.5 vs 4.7, P = .014) and 12 weeks (10.5 vs 2.1, P = .001) post-treatment. The total SCI score significantly improved from baseline to 6 weeks (78.4 vs 89.0, P = .001) post-treatment. The most frequent adverse events were radiation dermatitis, skin pain, and pruritus. All adverse events resolved to Grade ≤1 by 12 weeks post-treatment. CONCLUSIONS: This prospective, multicenter study demonstrated that ESSB is associated with a high rate of "good" early patient-reported cosmesis and increasing QoL and satisfaction with time. Validated assessments demonstrated a significant improvement in quality of life and resolution of moderate early adverse events by 6 to 12 weeks after treatment and corroborate the observation of favorable cosmesis.


Assuntos
Braquiterapia , Neoplasias da Mama , Carcinoma , Neoplasias Cutâneas , Humanos , Pessoa de Meia-Idade , Feminino , Qualidade de Vida , Estudos Prospectivos , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Neoplasias Cutâneas/radioterapia , Neoplasias da Mama/etiologia
8.
J Appl Clin Med Phys ; 23(10): e13776, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36109179

RESUMO

OBJECTIVE: Cesium-131 brachytherapy is an adjunct for brain tumor treatment, offering potential clinical and radiation protection advantages over other isotopes including iodine-125. We present evidence-based radiation safety recommendations from an initial experience with Cs-131 brachytherapy in the resection cavities of recurrent, previously irradiated brain metastases. METHODS: Twenty-two recurrent brain metastases in 18 patients were resected and treated with permanent Cs-131 brachytherapy implantation using commercially procured seed-impregnated collagen tiles (GammaTile, GT Medical Technologies). Exposure to intraoperative staff was monitored with NVLAP-accredited ring dosimeters. For patient release considerations, NCRP guidelines were used to develop an algorithm for modeling lifetime exposure to family and ancillary staff caring for patients based on measured dose rates. RESULTS: A median of 16 Cs-131 seeds were implanted (range 6-46) with median cumulative strength of 58.72U (20.64-150.42). Resulting dose rates were 1.19 mSv/h (0.28-3.3) on contact, 0.08 mSv/h (0.01-0.35) at 30 cm, and 0.01 mSv/h (0.001-0.03) at 100 cm from the patient. Modeled total caregiver exposure was 0.91 mSv (0.16-3.26), and occupational exposure was 0.06 mSv (0.02-0.23) accounting for patient self-shielding via skull and soft tissue attenuation. Real-time dose rate measurements were grouped into brackets to provide close contact precautions for caregivers ranging from 1-3 weeks for adults and longer for pregnant women and children, including cases with multiple implantations. CONCLUSIONS: Radiological protection precautions were developed based on patient-specific emissions and accounted for multiple implantations of Cs-131, to maintain exposure to staff and the public in accordance with relevant regulatory dose constraints.


Assuntos
Neoplasias Encefálicas , Proteção Radiológica , Gravidez , Adulto , Criança , Humanos , Feminino , Proteção Radiológica/métodos , Radioisótopos de Césio/uso terapêutico , Radioisótopos de Césio/efeitos adversos , Neoplasias Encefálicas/radioterapia , Encéfalo , Colágeno
10.
J Neurooncol ; 159(3): 609-618, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35896906

RESUMO

BACKGROUND: Salvage of recurrent previously irradiated brain metastases (rBrM) is a significant challenge. Resection without adjuvant re-irradiation is associated with a high local failure rate, while reirradiation only partially reduces failure but is associated with greater radiation necrosis risk. Salvage resection plus Cs131 brachytherapy may offer dosimetric and biologic advantages including improved local control versus observation, with reduced normal brain dose versus re-irradiation, however data are limited. METHODS: A prospective registry of consecutive patients with post-stereotactic radiosurgery (SRS) rBrM undergoing resection plus implantation of collagen-matrix embedded Cs131 seeds (GammaTile, GT Medical Technologies) prescribed to 60 Gy at 5 mm from the cavity was analyzed. RESULTS: Twenty patients underwent 24 operations with Cs131 implantation in 25 tumor cavities. Median maximum preoperative diameter was 3.0 cm (range 1.1-6.3). Gross- or near-total resection was achieved in 80% of lesions. A median of 16 Cs131 seeds (range 6-30), with a median air-kerma strength of 3.5 U/seed were implanted. There was one postoperative wound dehiscence. With median follow-up of 1.6 years for survivors, two tumors recurred (one in-field, one marginal) resulting in 8.4% 1-year progression incidence (95%CI = 0.0-19.9). Radiographic seed settling was identified in 7/25 cavities (28%) 1.9-11.7 months post-implantation, with 1 case of distant migration (4%), without clinical sequelae. There were 8 cases of radiation necrosis, of which 4 were symptomatic. CONCLUSIONS: With > 1.5 years of follow-up, intraoperative brachytherapy with commercially available Cs131 implants was associated with favorable local control and toxicity profiles. Weak correlation between preoperative tumor geometry and implanted tiles highlights a need to optimize planning criteria.


Assuntos
Produtos Biológicos , Braquiterapia , Neoplasias Encefálicas , Lesões por Radiação , Radiocirurgia , Braquiterapia/métodos , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Radioisótopos de Césio , Colágeno , Humanos , Necrose , Recidiva Local de Neoplasia/complicações , Recidiva Local de Neoplasia/radioterapia , Recidiva Local de Neoplasia/cirurgia , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento
11.
Med Phys ; 49(8): e983-e1023, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35662032

RESUMO

The task group (TG) on magnetic resonance imaging (MRI) implementation in high-dose-rate (HDR) brachytherapy (BT)-Considerations from simulation to treatment, TG 303, was constituted by the American Association of Physicists in Medicine's (AAPM's) Science Council under the direction of the Therapy Physics Committee, the Brachytherapy Subcommittee, and the Working Group on Brachytherapy Clinical Applications. The TG was charged with developing recommendations for commissioning, clinical implementation, and on-going quality assurance (QA). Additionally, the TG was charged with describing HDR BT workflows and evaluating practical consideration that arise when implementing MR imaging. For brevity, the report is focused on the treatment of gynecologic and prostate cancer. The TG report provides an introduction and rationale for MRI implementation in BT, a review of previous publications on topics including available applicators, clinical trials, previously published BT-related TG reports, and new image-guided recommendations beyond CT-based practices. The report describes MRI protocols and methodologies, including recommendations for the clinical implementation and logical considerations for MR imaging for HDR BT. Given the evolution from prescriptive to risk-based QA, an example of a risk-based analysis using MRI-based, prostate HDR BT is presented. In summary, the TG report is intended to provide clear and comprehensive guidelines and recommendations for commissioning, clinical implementation, and QA for MRI-based HDR BT that may be utilized by the medical physics community to streamline this process. This report is endorsed by the American Brachytherapy Society.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Estados Unidos
12.
Brachytherapy ; 21(5): 599-604, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35725549

RESUMO

PURPOSE/OBJECTIVE: To compare toxicity profiles of low-dose rate (LDR) and high-dose rate (HDR) brachytherapy boost combined with ultra-hypofractionated external beam radiation therapy (UH-EBRT). MATERIALS/METHODS: 99 patients with intermediate-risk prostate cancer underwent an HDR (n = 59) or LDR (n = 40) boost combined with UH-EBRT (5 Gy x 5) . HDR (Ir-192) was delivered a single dose (15 Gy) and LDR (Pd-103) prescription dose was 100 Gy. Median baseline IPSS was 5 for both cohorts. Median follow-up was 29.3mos. Cumulative incidences were calculated for toxicity. Fisher exact tests were used to evaluate associations. RESULTS: Overall incidence of grade 2 genitourinary toxicity for the entire cohort at 12 and 24 months was 21% and 29%, respectively. The incidence of grade 2 genitourinary toxicity at 12 and 24 months was higher for LDR cohort compared with HDR cohort (45% vs 5.1% and 55% vs 11%; p<0.001). On MVA, only treatment regimen (LDR versus HDR) was associated with grade 2+ genitourinary toxicity (p<0.001). Two patients experienced grade 2 rectal toxicity in each cohort. No grade > 3 toxicities were observed. CONCLUSIONS: Both LDR and HDR brachytherapy combined with UH-EBRT had favorable toxicity profiles, but significantly less grade 2+ genitourinary toxicity was observed in patients receiving HDR.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Masculino , Paládio/uso terapêutico , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/radioterapia , Radioisótopos/uso terapêutico , Dosagem Radioterapêutica
13.
Brachytherapy ; 21(1): 120-127, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34706854

RESUMO

PURPOSE: This is a multi-institutional report on inter-observer and inter-instrument variation in the calibration of the absorbed dose rate for a planar 32P beta emitting brachytherapy source. Measurement accuracy is essential since the dose profile is steep and the source is used for the treatment of tumors that are located in close proximity to healthy nervous system structures. METHODS AND MATERIALS: An RIC-100 32P source was calibrated by three institutions using their own equipment and following their standard procedures. The first institution calibrated the source with an electron diode and EBT3 film. The second institution used an electron diode. The third institution used HD810 film. Additionally, each institution was asked to calibrate the source using an electron diode and procedure that was shared among all institutions and shipped along with the radiation source. The dose rate was reported in units of cGy*min-1 at a water equivalent depth of 1 mm. RESULTS: Close agreement was observed in the measurements from different users and equipment. The variation across all diode detectors and institutions had a standard deviation of 1.8% and maximum difference of 4.6%. The observed variation among two different diode systems used within the same institution had a mean difference of 1.6% and a maximum variation of 1.8%. The variations among film and diode systems used within the same institution had a mean difference of 2.9% and a maximum variation of 4.3% CONCLUSIONS: The absorbed dose rate measurement protocol of the planar beta-emitting 32P source permits consistent dosimetry across three institutions and five different electron diode and radiochromic film systems. The methodologies presented herein should enable measurement consistency among other clinical users, which will help ensure high quality patient treatments and outcomes analysis.


Assuntos
Braquiterapia , Braquiterapia/métodos , Calibragem , Dosimetria Fotográfica , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Água
14.
BJU Int ; 129(3): 337-344, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34388295

RESUMO

OBJECTIVE: To determine the influence of rectal hydrogel spacer placement (HSP) on late rectal toxicity outcomes in prostate cancer patients treated with low-dose-rate (LDR) brachytherapy, with or without supplemental external beam radiotherapy (EBRT). PATIENTS AND METHODS: A total of 224 patients underwent LDR brachytherapy with HSP, as monotherapy or combined with EBRT, between January 2016 and December 2019. Dosimetric variables reflecting the extent of rectal sparing and late rectal toxicity outcomes were evaluated. This spacer cohort was retrospectively compared to a similar patient group (n = 139) in whom HSP was not used. RESULTS: Hydrogel spacer placement was associated with significantly reduced rectal doses for all dosimetric variables; the median percentage rectal dose to 1 cc of rectum and rectal dose to 2 cc of rectum of the spacer cohort were all significantly lower compared to the non-spacer cohort. The incidence rates of overall (any grade) and grade ≥2 rectal toxicity were lower in patients with HSP compared to patients who did not undergo HSP: 12% and 1.8% vs 31% and 5.8%, respectively. The 3-year cumulative incidence of overall rectal toxicity was significantly lower with HSP than without (15% vs 33%; P < 0.001), corresponding to an overall rectal toxicity reduction on univariable analysis (hazard ratio 0.45, 95% confidence interval 0.28-0.73; P = 0.001). In this patient cohort treated with prostate brachytherapy, none of the urethral dosimetric variables or the presence or absence of HSP was associated with late urinary toxicity. CONCLUSION: Hydrogel rectal spacer placement is a safe procedure, associated with significantly reduced rectal dose. HSP translates to a decrease in overall late rectal toxicity in patients receiving dose-escalated brachytherapy-based procedures.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/efeitos adversos , Braquiterapia/métodos , Humanos , Hidrogéis/efeitos adversos , Masculino , Próstata , Neoplasias da Próstata/etiologia , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Reto , Estudos Retrospectivos
15.
Brachytherapy ; 20(6): 1099-1106, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34588146

RESUMO

PURPOSE: This study evaluated outcomes associated with a high-dose-rate (HDR) brachytherapy boost combined with stereotactic body radiation therapy (SBRT) for patients with higher-risk localized prostate cancer. MATERIALS AND METHODS: We identified 101 patients with National Comprehensive Cancer Network high-risk, unfavorable intermediate-risk, or favorable intermediate-risk with probable extra-prostatic extension treated with HDR brachytherapy (15 Gy x 1 fraction) followed by SBRT (5 Gy x 5 daily fractions to the prostate and/or seminal vesicles and/or pelvic lymph nodes). Androgen deprivation therapy was used in 55.4% of all patients (90% of high-risk, 33% of intermediate-risk). Toxicities according to Common Terminology Criteria for Adverse Events (CTCAE) v4.0 and International Prostate Symptom Scores were prospectively documented at each followup visit. Biochemical relapse was defined as PSA nadir +2ng/mL. RESULTS: The median follow-up time after SBRT was 24.1 months. No grade ≥3 toxicities were observed. The incidence of acute and late grade 2 gastrointestinal toxicities was both 0.99%. Acute and late grade 2 genitourinary (GU) toxicities were observed in 5.9% and 9.9%, respectively. Median time to a grade 2 GU toxicity was 6 months with a 14% 2-year actuarial rate of grade 2 GU toxicity. Median International Prostate Symptom Scores at 24 months was not significantly different than baseline (6 vs. 5; p = 0.24). Inclusion of pelvic lymph nodes and absence of a rectal spacer were significantly associated with more frequent grade ≥1 GU toxicity, but not grade ≥2 GU or gastrointestinal toxicity. The 2-year biochemical relapse free survival was 97%. CONCLUSIONS: HDR brachytherapy combined with SBRT was associated with a favorable early toxicity profile and encouraging cancer control outcomes.


Assuntos
Braquiterapia , Neoplasias da Próstata , Antagonistas de Androgênios , Braquiterapia/métodos , Humanos , Masculino , Antígeno Prostático Específico , Neoplasias da Próstata/radioterapia , Hipofracionamento da Dose de Radiação
16.
Brachytherapy ; 20(5): 1062-1069, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34193362

RESUMO

PURPOSE: To quantitatively evaluate through automated simulations the clinical significance of potential high-dose rate (HDR) prostate brachytherapy (HDRPB) physics errors selected from our internal failure-modes and effect analysis (FMEA). METHODS AND MATERIALS: A list of failure modes was compiled and scored independently by 8 brachytherapy physicists on a one-to-ten scale for severity (S), occurrence (O), and detectability (D), with risk priority number (RPN) = SxOxD. Variability of RPNs across observers (standard deviation/average) was calculated. Six idealized HDRPB plans were generated, and error simulations were performed: single (N = 1722) and systematic (N = 126) catheter shifts (craniocaudal; -1cm:1 cm); single catheter digitization errors (tip and connector needle-tips displaced independently in random directions; 0.1 cm:0.5 cm; N = 44,318); and swaps (two catheters swapped during digitization or connection; N = 528). The deviations due to each error in prostate D90%, urethra D20%, and rectum D1cm3 were analyzed using two thresholds: 5-20% (possible clinical impact) and >20% (potentially reportable events). RESULTS: Twenty-nine relevant failure modes were described. Overall, RPNs ranged from 6 to 108 (average ± 1 standard deviation, 46 ± 23), with responder variability ranging from 19% to 184% (average 75% ± 30%). Potentially reportable events were observed in the simulations for systematic shifts >0.4 cm for prostate and digitization errors >0.3 cm for the urethra and >0.4 cm for rectum. Possible clinical impact was observed for catheter swaps (all organs), systematic shifts >0.2 cm for prostate and >0.4 cm for rectum, and digitization errors >0.2 cm for prostate and >0.1 cm for urethra and rectum. CONCLUSIONS: A high variability in RPN scores was observed. Systematic simulations can provide insight in the severity scoring of multiple failure modes, supplementing typical FMEA approaches.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Masculino , Física , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
17.
J Am Acad Dermatol ; 84(6): 1575-1584, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32827607

RESUMO

BACKGROUND: Radiation therapy (RT) is a treatment option for select skin cancers. The histologic effects of RT on normal skin or skin cancers are not well characterized. Dermoscopy, high-frequency ultrasonography (HFUS), and reflectance confocal microscopy (RCM) are noninvasive imaging modalities that may help characterize RT response. OBJECTIVES: To describe changes in the tumor and surrounding skin of patients with basal cell carcinoma (BCC) treated with RT. METHODS: The study was conducted between 2014 and 2018. Patients with biopsy-proven BCCs were treated with 42 Gy in 6 fractions using a commercially available brachytherapy device. Dermoscopy, HFUS, and RCM were performed before treatment and at 6 weeks, 3 months, and 12 months after RT. RESULTS: A total of 137 imaging assessments (RCM + dermoscopy + HFUS) were performed in 12 patients. BCC-specific features were present in 81.8%, 91%, and 17% of patients imaged with dermoscopy, RCM, and HFUS at baseline, respectively, before treatment. After treatment, the resolution of these features was noted in 33.4%, 91.7%, and 100% of patients imaged with the respective modalities. No recurrences were seen after a mean of 31.7 months of follow-up. LIMITATIONS: Small sample size and no histopathologic correlation. CONCLUSION: Dermoscopy and HFUS were not as reliable as RCM at characterizing BCC RT response.


Assuntos
Carcinoma Basocelular/radioterapia , Fracionamento da Dose de Radiação , Recidiva Local de Neoplasia/diagnóstico , Neoplasias Cutâneas/radioterapia , Pele/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma Basocelular/diagnóstico , Dermoscopia/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Microscopia Confocal/estatística & dados numéricos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/prevenção & controle , Estudos Prospectivos , Reprodutibilidade dos Testes , Pele/efeitos da radiação , Neoplasias Cutâneas/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia/estatística & dados numéricos
18.
Brachytherapy ; 19(6): 762-766, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32952055

RESUMO

PURPOSE: Safe delivery of brachytherapy and establishing a safety culture are critical in high-quality brachytherapy. The American Brachytherapy Society (ABS) Quality and Safety Committee surveyed members regarding brachytherapy services offered, safety practices during treatment, quality assurance procedures, and needs to develop safety and training materials. METHODS AND MATERIALS: A 22-item survey was sent to ABS membership in early 2019 to physicians, physicists, therapists, nurses, and administrators. Participation was voluntary. Responses were summarized with descriptive statistics and relative frequency distributions. RESULTS: There were 103 unique responses. Approximately one in three was attending physicians and one in three attending physicists. Most were in practice >10 years. A total of 94% and 50% performed gynecologic and prostate brachytherapy, respectively. Ninety-one percent performed two-identification patient verification before treatment. Eighty-six percent performed a time-out. Ninety-five percent had an incident reporting or learning system, but only 71% regularly reviewed incidents. Half reviewed safety practices within the last year. Twenty percent reported they were somewhat or not satisfied with department safety culture, but 92% of respondents were interested in improving safety culture. Most reported time, communication, and staffing as barriers to improving safety. Most respondents desired safety-oriented webinars, self-assessment modules, learning modules, or checklists endorsed by the ABS to improve safety practice. CONCLUSIONS: Most but not all practices use standards and quality assurance procedures in line with society recommendations. There is a need to heighten safety culture at many departments and to shift resources (e.g., time or staffing) to improve safety practice. There is a desire for society guidance to improve brachytherapy safety practices. This is the first survey to assess safety practice patterns among a national sample of radiation oncologists with expertise in brachytherapy.


Assuntos
Braquiterapia/estatística & dados numéricos , Neoplasias dos Genitais Femininos/radioterapia , Segurança do Paciente , Neoplasias da Próstata/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Radioterapia (Especialidade)/organização & administração , Braquiterapia/efeitos adversos , Braquiterapia/normas , Lista de Checagem , Comunicação , Feminino , Humanos , Masculino , Cultura Organizacional , Sistemas de Identificação de Pacientes/estatística & dados numéricos , Admissão e Escalonamento de Pessoal , Melhoria de Qualidade , Gestão de Riscos/estatística & dados numéricos , Inquéritos e Questionários , Fatores de Tempo
19.
Int J Radiat Oncol Biol Phys ; 108(4): 905-913, 2020 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-32505609

RESUMO

PURPOSE: To report early toxicity and tumor control outcomes of Pd-103 brachytherapy with ultrahypofractionated stereotactic radiation therapy (RT) for intermediate-risk prostate cancer. METHODS AND MATERIALS: This prospective trial included 40 patients with intermediate-risk prostate cancer who underwent low-dose-rate (Pd-103) brachytherapy (prescription dose, 100 Gy), followed 1 month later with ultrahypofractionated stereotactic RT (25 Gy in 5 fractions) to the prostate and seminal vesicles. The primary endpoint was the rate of grade 2+ genitourinary toxicity at 12 months using Common Terminology Criteria for Adverse Events v 4.0. Secondary endpoints included patient-reported quality-of-life metrics (International Prostate Scoring System [IPSS], International Index of Erectile Function, and Expanded Prostate Cancer Index Composite-bowel). Biochemical failure was defined as prostate-specific antigen nadir +2 ng/mL. Posttreatment biopsies were performed at between 24 and 36 months; median follow-up was 36 months. RESULTS: The rate of grade 2 urinary toxicity at 12 months was 25% with no grade 3 urinary toxicity noted. Mean IPSS at baseline and 12 and 24 months was 5, 10, and 6.2, respectively. Mean change in IPSS from baseline at 12 months was +5.5 (interquartile range, 1-9.75) and +1.05 (interquartile range, -3 to 3.25) at 24 months. Grade 2 bowel toxicity was 5% at 12 months with no grade 3 bowel toxicity noted. Mean Expanded Prostate Cancer Index Composite-bowel domain scores at baseline and 12 months were 92.8 and 90.3, respectively. Of patients who were potent (International Index of Erectile Function ≥21) at baseline, 75% remained potent at 12 months. Of 40 patients, 28 underwent posttreatment prostate biopsy (PPB), which was negative (n = 20) or demonstrated severe treatment effect (n = 8). No patient had a positive PPB or developed biochemical failure during the follow-up period. One patient without a PPB developed osseous metastases at 18 months posttreatment in the absence of biochemical failure. CONCLUSION: Low-dose-rate brachytherapy in combination with ultrahypofractionated stereotactic RT was safe and effective for intermediate-risk prostate cancer in early results of this trial.


Assuntos
Braquiterapia/métodos , Paládio/uso terapêutico , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Hipofracionamento da Dose de Radiação , Radioisótopos/uso terapêutico , Idoso , Braquiterapia/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Órgãos em Risco , Ereção Peniana/efeitos da radiação , Estudos Prospectivos , Próstata/patologia , Próstata/efeitos da radiação , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Qualidade de Vida , Lesões por Radiação/patologia , Reto/efeitos da radiação , Glândulas Seminais/efeitos da radiação , Transtornos Urinários/etiologia
20.
Brachytherapy ; 19(4): 415-426, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32409128

RESUMO

PURPOSE: Keratinocyte carcinoma (KC, previously nonmelanoma skin cancer) represents the most common cancer worldwide. While surgical treatment is commonly utilized, various radiation therapy techniques are available including external beam and brachytherapy. As such, the American Brachytherapy Society has created an updated consensus statement regarding the use of brachytherapy in the treatment of KCs. METHODS: Physicians and physicists with expertise in skin cancer and brachytherapy created a consensus statement for appropriate patient selection, data, dosimetry, and utilization of skin brachytherapy and techniques based on a literature search and clinical experience. RESULTS: Guidelines for patient selection, evaluation, and dose/fractionation schedules to optimize outcomes for patients with KC undergoing brachytherapy are presented. Studies of electronic brachytherapy are emerging, although limited long-term data or comparative data are available. Radionuclide-based brachytherapy represents an appropriate option for patients with small KCs with multiple techniques available. CONCLUSIONS: Skin brachytherapy represents a standard of care option for appropriately selected patients with KC. Radionuclide-based brachytherapy represents a well-established technique; however, the current recommendation is that electronic brachytherapy be used for KC on prospective clinical trial or registry because of a paucity of mature data.


Assuntos
Braquiterapia/normas , Carcinoma Basocelular/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Cutâneas/radioterapia , Braquiterapia/métodos , Consenso , Fracionamento da Dose de Radiação , Humanos , Seleção de Pacientes , Radioisótopos/uso terapêutico , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...