Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
3.
Surg Gynecol Obstet ; 162(3): 277-8, 1986 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3952622

RESUMO

An improved subclavian cannulation technique using a 3 milliliter syringe attached to a No. 16 gauge needle and a guide wire is presented. Major complications, such as air embolism, vein laceration and retained catheter fragments, are eliminated by using this method of catheterization.


Assuntos
Cateterismo/métodos , Veia Subclávia , Cateterismo/instrumentação , Humanos
4.
Angiology ; 36(9): 656-61, 1985 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-4051257

RESUMO

Most major intra-abdominal fistulas result from trauma or surgery. Spontaneous fistulas are rare with less than 100 reported cases since 1831. From a review of hospital records, five such spontaneous fistulas were identified among 215 cases of abdominal aortic aneurysm between 1975 and 1983. These cases are presented and supplemented by 73 similar cases collected from a literature review for discussion of the salient features of clinical presentation and management of spontaneous major fistulas. Major intra-abdominal arteriovenous fistulas usually present with a machinery bruit over a pulsatile mass, but may present more subtly with pain and otherwise unexplained hematuria. Because these fistulas lead to refractory heart failure, surgery should be expeditious. Closure should be performed from within the aneurysm with arterial and pulmonary artery pressure monitoring. Care must be taken to prevent pulmonary embolization.


Assuntos
Aneurisma Aórtico/complicações , Fístula Arteriovenosa/etiologia , Idoso , Aorta Abdominal , Aneurisma Aórtico/cirurgia , Fístula Arteriovenosa/cirurgia , Hematúria/etiologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Estudos Retrospectivos
7.
JAMA ; 243(13): 1350-5, 1980 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-7359697

RESUMO

To reduce operative mortality in elderly patients, a system of preoperative staging, based on invasive monitoring, was developed. All of the 148 consecutive patients studied had been cleared for surgery by standard assessment, but only 13.5% had normal measured, hemodynamic, respiratory, and oxygen transport function. Mild physiologic aberrations, not requiring a delay in surgery, or more severe abnormalities, indicative of high operative risk, were found in 63.5% of the patients. Advanced and incorrigible functional defects found in the remaining 23% made them unacceptable risks for major surgery under general anesthesia, and all who underwent the planned operation in spite of the warning died. Invasive preoperative assessment of elderly patients discloses a high percentage of serious physiologic abnormalities requiring a delay in some and cancellation of the operation in others.


Assuntos
Idoso , Monitorização Fisiológica/métodos , Cuidados Pré-Operatórios , Procedimentos Cirúrgicos Operatórios/mortalidade , Hemodinâmica , Humanos , Complicações Pós-Operatórias/prevenção & controle , Risco
8.
Ann Thorac Surg ; 28(5): 445-50, 1979 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-496497

RESUMO

Over a 7-year period, follow-up data were available on 163 patients who underwent 209 pacemaker-related operations for initial insertion or revision of previously implanted units. During the follow-up period, 16 pacemaker generator units were remoaved from 16 pacemaker generator units were removed from 12 patients solely because of the development of local skin erosion. This represents a 7.7% incidence of pacemaker generator erosion. Tree units were removed within a 3-month interval following pacemaker implantation and were associated with positive bacterial cultures, theraby indicating an infectious cause. Findings at removal of the remaining 13 pacemaker generators included extensive fibrosis with chronic inflammation, fibroblastic proliferation, and granulation tissue, which was most prominent at the site of insertion of the pacemaker lead into the pacemaker generator unit. Granulation tissue frequently led from this area to the area of skin attenuation and erythema. Inspection of the pacemaker generator units and electrodes demonstrated fluid ingress and tissue ingrowth toward the electrode due to inadequate seal mechanisms. Inadequate seal design of the pacemaker generator and electrode junction leads to tissue ingrowth with fibroblastic proliferatiog chronic inflammation, and eventual pacemaker erosion.


Assuntos
Marca-Passo Artificial/efeitos adversos , Úlcera Cutânea/etiologia , Infecções Estafilocócicas/etiologia , Doenças Torácicas/etiologia , Idoso , Eletrodos/efeitos adversos , Eletrodos/normas , Seguimentos , Tecido de Granulação/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/normas , Pele/patologia , Úlcera Cutânea/microbiologia , Úlcera Cutânea/patologia , Infecções Estafilocócicas/patologia , Doenças Torácicas/microbiologia , Doenças Torácicas/patologia , Fatores de Tempo
10.
Crit Care Med ; 7(2): 54-8, 1979 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-455999

RESUMO

Estimation of intrapulmonary blood shunt fraction requires accurate evaluation of pulmonary capillary, arterial, and mixed venous oxygen contents. The presence of carboxyhemoglobin, as well as methemoglobin and sulfhemoglobin, may lead to large errors in the calculated intrapulmonary blood shunt fraction. The errors are most pronounced at low values of carboxyhemoglobin and low values of true intrapulmonary shunt fraction.


Assuntos
Carboxihemoglobina/metabolismo , Hemoglobinas/metabolismo , Pulmão/metabolismo , Relação Ventilação-Perfusão , Humanos , Manometria , Consumo de Oxigênio
11.
Intensive Care Med ; 4(2): 93-7, 1978 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-348736

RESUMO

Indocyanine green dye dilution curves with abnormal contours have been recorded in four patients with acute and critical illnesses using standardized recording methods. The abnormal curves are characterized by a high and prolonged concentration of dye occurring after the peak concentration. This altered contour can be detected by use of routine mathematical processing since the derived hemodynamic parameters are affected by the altered contour. A physiologic basis for the altered curve contour is proposed.


Assuntos
Técnica de Diluição de Corante , Sistema Vasomotor , Doença Aguda , Adolescente , Adulto , Circulação Sanguínea , Débito Cardíaco , Feminino , Hemodinâmica , Humanos , Verde de Indocianina , Sistema Vasomotor/fisiopatologia
12.
Crit Care Med ; 6(1): 32-5, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-639529

RESUMO

Two cases of flow-directed, balloon-tipped catheterizations of the right heart via a persistent left superior vena cava are presented. In both cases, the monitoring catheters assumed similar, atypical configurations on plain chest roentgenograms. Recognition of the characteristic configuration of the course of transvenous catheters through the persistent left superior vena cava allows for plain film diagnosis of this anomaly.


Assuntos
Cateterismo , Veia Cava Superior/anormalidades , Adulto , Anormalidades Congênitas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Radiografia
13.
Am J Surg ; 135(1): 70-5, 1978 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-623375

RESUMO

A modification of the Berggren pulmonary shunt equation was derived for use in estimating the splenic component of portal hypertension. It was used in nine patients, six of whom had sufficient decreases in portal flow and pressure after splenic artery and coronary vein ligation. The average decrease in portal flow was 52%.


Assuntos
Hipertensão Portal/cirurgia , Artéria Esplênica/cirurgia , Pressão Venosa , Adulto , Idoso , Determinação da Pressão Arterial/métodos , Vasos Coronários/cirurgia , Humanos , Matemática , Pessoa de Meia-Idade , Oxigênio/sangue , Consumo de Oxigênio , Sistema Porta/cirurgia
14.
JACEP ; 6(11): 479-85, 1977 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-916477

RESUMO

An automated system has been developed for measuring hemodynamic, oxygen transport and tissue utilization functions. Rapid measurement and data analysis of physiologic profiles by paramedical personnel allow prompt evaluation of altered cardiovascular function. Evaluation of physiologic function allows therapeutic interventions to be instituted on a timely basis, appropriately directed toward improvement of the measured cardiovascular abnormalities. Physiologic profile studies were performed on 1016 occasions in 580 patients during a three-year period and form the basis of this report. Although utilized on hospitalized patients, there are implications for use in evaluating and treating all critically ill patients.


Assuntos
Sistema Cardiovascular/fisiopatologia , Cuidados Críticos , Monitorização Fisiológica/métodos , Transporte Biológico Ativo , Circulação Sanguínea , Cateterismo Cardíaco , Hemodinâmica , Humanos , Consumo de Oxigênio , Respiração
15.
Med Instrum ; 11(5): 311-4, 1977.
Artigo em Inglês | MEDLINE | ID: mdl-916927

RESUMO

A relatively simple and inexpensive data management system is described with which comprehensive physiologic and cardiovascular profiles are produced. The system is comprised of a desk-top programmable calculator interfaced with an acoustic digitizer input, and an X-Y plotter, with alphanumeric printing output capability. Numerical clinical data such as intracardiac pressures and blood gas values are entered into the calculator via the keyboard, and graphical data such as dye-dilution curves or ventricular contours are digitized with a pen stylus on the acoustic tablet. The data are processed in the calculator and the results charted in familiar and readily interpreted bar-graph format on preprinted charts on the X-Y plotter. The entire system is inexpensive and compact enough to be applicable to small- and medium-size community hospitals.


Assuntos
Fenômenos Fisiológicos Cardiovasculares , Processamento Eletrônico de Dados/instrumentação , Monitorização Fisiológica/instrumentação , Custos e Análise de Custo , Humanos , Monitorização Fisiológica/economia
17.
Am J Surg ; 132(5): 668-9, 1976 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-790987

RESUMO

Effective median sternotomy closure requires approximation of the sterum under appropriate tension in an expeditious manner. An instrument has been developed to provide tightening of applied sternal wires, allowing proper tension to be established. After tightening, the twisted wire is automatically trimmed by the instrument. The ease and reproducibility of this wire closure technic has allowed the method to be performed on a routine basis.


Assuntos
Esterno/cirurgia , Técnicas de Sutura/instrumentação , Aço Inoxidável , Instrumentos Cirúrgicos
18.
Med Instrum ; 10(5): 242-7, 1976.
Artigo em Inglês | MEDLINE | ID: mdl-967073

RESUMO

Measurements of hemodynamic, oxygen transport, and tissue utilization functions were incorporated into a physiologic profile assessment system in order to evaluate patients who are candidates for mechanical support of the failing heart. Circulatory function was assessed in patients with acute myocardial infarction associated with diminished peripheral perfusion and compared to an age-matched, normal patient group. Serial studies performed prior to and during intra-aortic balloon counterpulsation provide a means to assess circulatory status accurately and document the efficacy of therapeutic interventions.


Assuntos
Circulação Assistida/métodos , Hemodinâmica , Consumo de Oxigênio , Oxigênio/sangue , Doença Aguda , Idoso , Fenômenos Fisiológicos Cardiovasculares , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...