1.
Med Phys ; 45(1): 370-381, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29131343

RESUMO

PURPOSE: The average energy expended by an energetic electron to create an ion pair in dry air, Wair , is a key quantity in radiation dosimetry. Although Wair is well established for electron energies up to about 3 MeV, there is limited data for higher energies. The measurements by Domen and Lamperti [Med. Phys. 3, 294-301 (1976)] using electron beams in the energy range from 15 to 50 MeV can, in principle, be used to deduce values for Wair , if the electron stopping power of graphite and air are known. A previous analysis of these data revealed an anomalous variation of 2% in Wair as a function of the electron energy. We use Monte Carlo simulation techniques to reanalyze the original data and obtain new estimates for Wair , and to investigate the source of the reported anomaly. METHODS: Domen and Lamperti (DL) reported the ratio of the response of a graphite calorimeter to that of a graphite ionization chamber for broad beams of electrons with energies between 15 and 50 MeV and at different depths in graphite (including depths well beyond the range of the primary electrons, i.e., in the bremsstrahlung photon regime). Using a detailed EGSnrc model of the DL apparatus, as well as up-to-date stopping powers, we compute the dose ratio between the ionization chamber cavity and the calorimeter core, for plane-parallel electron beams. This dose ratio, multiplied by the DL measured ratio, provides a direct estimate for Wair . RESULTS: Despite an improved analysis of the original work, the extracted values of Wair still exhibit an increase as the mean electron energy at the point of measurement decreases below about 15 MeV. This anomalous trend is dubious physically, and inconsistent with extensive data for Wair obtained at lower energies. A thorough sensitivity analysis indicates that this trend is unlikely to stem from errors in extrapolation and correction procedures, uncertainties in electron stopping powers, or bias in calorimetry or ionization chamber measurements. However, we find that results are quite sensitive to the intrinsic graphite mass thickness of the detectors and to the incident beam energy. CONCLUSIONS: The DL experiment provides data in an energy regime where the electron stopping power is insensitive to the mean excitation energy of graphite - an issue plaguing Wair experiments at lower energies. Unfortunately, state-of-the-art scrutiny of the original data cannot explain the anomalous trend in terms of perturbation effects or extrapolation bias. It can only be understood in terms of speculative offsets in graphite mass thickness or beam energy. Therefore higher accuracy measurements for electron energies above 15 MeV are recommended to further resolve the value of Wair .


Assuntos
Elétrons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Ar , Simulação por Computador , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/instrumentação
2.
Med Phys ; 44(10): 5433-5444, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28688120

RESUMO

PURPOSE: To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, kQ , for several ion chamber types. METHODS: Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator. Ion chamber measurements are made as a function of depth for cylindrical and plane-parallel ion chambers over a period of five years to investigate the stability of ion chamber response and for indirect calibration. Water calorimetry measurements are made in 18 MeV and 22 MeV beams. An insulated enclosure with fine temperature control is used to maintain a constant temperature (drifts less than 0.1 mK/min) of the calorimeter phantom at 4°C to minimize effects from convection. Two vessels of different designs are used with calibrated thermistor probes to measure radiation induced temperature rise. The vessels are filled with high-purity water and saturated with H2 or N2 gas to minimize the effect of radiochemical reactions on the measured temperature rise. A set of secondary standard ion chambers are calibrated directly against the calorimeter. Finally, several other ion chambers are calibrated in the NRC 60 Co reference field and then cross-calibrated against the secondary standard chambers in electron beams to realize kQ factors. RESULTS: The long-term stability of the cylindrical ion chambers in electron beams is better (always <0.15%) than plane-parallel chambers (0.2% to 0.4%). Calorimetry measurements made at 22 MeV with two different vessel geometries are consistent within 0.2% after correction for the vessel perturbation. Measurements of absorbed dose calibration coefficients for the same secondary standard chamber separated in time by 10 yr are within 0.2%. Drifts in linac output that would affect the transfer of the standard are mitigated to the 0.1% level by performing daily ion chamber normalization measurements. Calibration coefficients for secondary standard ion chambers can be achieved with uncertainties less than 0.4% (k = 1) in high-energy electron beams. The additional uncertainty in deriving calibration coefficients for well-behaved chambers indirectly against the secondary standard reference chambers is negligible. The kQ factors measured here differ by up to 1.3% compared to those in TG-51, an important change for reference dosimetry measurements. CONCLUSIONS: The measurements made here of kQ factors for eight plane-parallel and six cylindrical ion chambers will impact future updates of reference dosimetry protocols by providing some of the highest quality measurements of this crucial dosimetric parameter.


Assuntos
Calorimetria , Elétrons , Água , Calibragem , Controle de Qualidade , Radiometria , Temperatura , Incerteza