1.
Sci Rep ; 13(1): 14470, 2023 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-37660227

RESUMO

Lentiviral vectors (LV) have proven to be powerful tools for stable gene delivery in both dividing and non-dividing cells. Approval of these LVs for use in clinical applications has been achieved by improvements in LV design. Critically important characteristics concerning quality control are LV titer quantification and the detection of impurities. However, increasing evidence concerning high variability in titration assays indicates poor harmonization of the methods undertaken to date. In this study, we developed a direct reverse transcription droplet digital PCR (Direct RT-ddPCR) approach without RNA extraction and purification for estimation of LV titer and RNA genome integrity. The RNA genome integrity was assessed by RT-ddPCR assays targeted to four distant regions of the LV genome. Results of the analyses showed that direct RT-ddPCR without RNA extraction and purification performs similarly to RT-ddPCR on purified RNA from 3 different LV samples, in terms of robustness and assay variance. Interestingly, these RNA titer results were comparable to physical titers by p24 antigen ELISA (enzyme-linked immunosorbent assay). Moreover, we confirmed the partial degradation or the incomplete RNA genomes in the prepared 3 LV samples. These results may partially explain the discrepancy of the LV particle titers to functional titers. This work not only demonstrates the feasibility of direct RT-ddPCR in determining LV titers, but also provides a method that can be easily adapted for RNA integrity assessment.


Assuntos
RNA , Transcrição Reversa , Bioensaio , Ensaio de Imunoadsorção Enzimática , Reação em Cadeia da Polimerase
2.
iScience ; 25(7): 104554, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35800774

RESUMO

Plasma cell-free DNA is being widely explored as a biomarker for clinical screening. Currently, methods are optimized for the extraction and detection of double-stranded mononucleosomal cell-free DNA of ∼160bp in length. We introduce uscfDNA-seq, a single-stranded cell-free DNA next-generation sequencing pipeline, which bypasses previous limitations to reveal a population of ultrashort single-stranded cell-free DNA in human plasma. This species has a modal size of 50nt and is distinctly separate from mononucleosomal cell-free DNA. Treatment with single-stranded and double-stranded specific nucleases suggests that ultrashort cell-free DNA is primarily single-stranded. It is distributed evenly across chromosomes and has a similar distribution profile over functional elements as the genome, albeit with an enrichment over promoters, exons, and introns, which may be suggestive of a terminal state of genome degradation. The examination of this cfDNA species could reveal new features of cell death pathways or it can be used for cell-free DNA biomarker discovery.

3.
Artigo em Inglês | MEDLINE | ID: mdl-34250423

RESUMO

We report the results from a Foundation for the National Institutes of Health Biomarkers Consortium project to address the absence of well-validated quality control materials (QCMs) for circulating tumor DNA (ctDNA) testing. This absence is considered a cause of variance and inconsistencies in translating ctDNA results into clinical actions. METHODS: In this phase I study, QCMs with 14 clinically relevant mutations representing single nucleotide variants, insertions or deletions (indels), translocations, and copy number variants were sourced from three commercial manufacturers with variant allele frequencies (VAFs) of 5%, 2.5%, 1%, 0.1%, and 0%. Four laboratories tested samples in quadruplicate using two allele-specific droplet digital polymerase chain reaction and three (amplicon and hybrid capture) next-generation sequencing (NGS) panels. RESULTS: The two droplet digital polymerase chain reaction assays reported VAF values very close to the manufacturers' claimed concentrations for all QCMs. NGS assays reported most single nucleotide variants and indels, but not translocations, close to the expected VAF values. Notably, two NGS assays reported lower VAF than expected for all translocations in all QCM mixtures, possibly related to technical challenges detecting these variants. The ability to call ERBB2 copy number amplifications varied across assays. All three QCMs provided valuable insight into assay precision. Each assay across all variant types demonstrated dropouts at 0.1%, suggesting that the QCM can serve for testing of an assay's limit of detection with confidence claims for specific variants. CONCLUSION: These results support the utility of the QCM in testing ctDNA assay analytical performance. However, unique designs and manufacturing methods for the QCM, and variations in a laboratory's testing configuration, may require testing of multiple QCMs to find the best reagents for accurate result interpretation.


Assuntos
DNA Tumoral Circulante/genética , Sequenciamento de Nucleotídeos em Larga Escala , Neoplasias/genética , Reação em Cadeia da Polimerase , Controle de Qualidade , Biomarcadores Tumorais/genética , DNA Tumoral Circulante/sangue , Variações do Número de Cópias de DNA , Frequência do Gene , Humanos , Mutação/genética , National Institutes of Health (U.S.) , Neoplasias/sangue , Estados Unidos
4.
Sci Rep ; 11(1): 389, 2021 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-33431989

RESUMO

Lentiviral vectors (LV) have emerged as a robust technology for therapeutic gene delivery into human cells as advanced medicinal products. As these products are increasingly commercialized, there are concomitant demands for their characterization to ensure safety, efficacy and consistency. Standards are essential for accurately measuring parameters for such product characterization. A critical parameter is the vector copy number (VCN) which measures the genetic dose of a transgene present in gene-modified cells. Here we describe a set of clonal Jurkat cell lines with defined copy numbers of a reference lentiviral vector integrated into their genomes. Genomic DNA was characterized for copy number, genomic integrity and integration coordinates and showed uniform performance across independent quantitative PCR assays. Stability studies during continuous long-term culture demonstrated sustained renewability of the reference standard source material. DNA from the Jurkat VCN standards would be useful for control of quantitative PCR assays for VCN determination in LV gene-modified cellular products and clinical samples.


Assuntos
Dosagem de Genes , Lentivirus/genética , Transdução Genética , Calibragem/normas , Técnicas de Transferência de Genes/normas , Vetores Genéticos/genética , Humanos , Células Jurkat , Mutagênese Insercional/genética , Padrões de Referência , Reprodutibilidade dos Testes , Transdução Genética/métodos , Transdução Genética/normas , Transfecção/métodos , Transfecção/normas , Estudos de Validação como Assunto , Integração Viral/genética
5.
Clin Chem Lab Med ; 57(8): 1142-1152, 2019 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-31112502

RESUMO

Background The National Institute of Standards and Technology (NIST) Reference Material RM 8366 was developed to improve the quality of gene copy measurements of EGFR (epidermal growth factor receptor) and MET (proto-oncogene, receptor tyrosine kinase), important targets for cancer diagnostics and treatment. The reference material is composed of genomic DNA prepared from six human cancer cell lines with different levels of amplification of the target genes. Methods The reference values for the ratios of the EGFR and MET gene copy numbers to the copy numbers of reference genes were measured using digital PCR. The digital PCR measurements were confirmed by two additional laboratories. The samples were also characterized using Next Generation Sequencing (NGS) methods including whole genome sequencing (WGS) at three levels of coverage (approximately 1 ×, 5 × and greater than 30 ×), whole exome sequencing (WES), and two different pan-cancer gene panels. The WES data were analyzed using three different bioinformatic algorithms. Results The certified values (digital PCR) for EGFR and MET were in good agreement (within 20%) with the values obtained from the different NGS methods and algorithms for five of the six components; one component had lower NGS values. Conclusions This study shows that NIST RM 8366 is a valuable reference material to evaluate the performance of assays that assess EGFR and MET gene copy number measurements.


Assuntos
Sequenciamento de Nucleotídeos em Larga Escala/normas , Proteínas Proto-Oncogênicas c-met/genética , DNA de Neoplasias/genética , Receptores ErbB/genética , Receptores ErbB/normas , Dosagem de Genes , Humanos , Reação em Cadeia da Polimerase , Proto-Oncogene Mas , Proteínas Proto-Oncogênicas c-met/normas , Padrões de Referência , Células Tumorais Cultivadas
6.
J Mol Diagn ; 21(4): 658-676, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31055023

RESUMO

We conducted a multilaboratory assessment to determine the suitability of a new commercially available reference material with 40 cancer variants in a background of wild-type DNA at four different variant allele frequencies (VAFs): 2%, 0.50%, 0.125%, and 0%. The variants include single nucleotides, insertions, deletions, and two structural variations selected for their clinical importance and to challenge the performance of next-generation sequencing (NGS) methods. Fragmented DNA was formulated to simulate the size distribution of circulating wild-type and tumor DNA in a synthetic plasma matrix. DNA was extracted from these samples and characterized with different methods and multiple laboratories. The various extraction methods had differences in yield, perhaps because of differences in chemistry. Digital PCR assays were used to measure VAFs to compare results from different NGS methods. Comparable VAFs were observed across the different NGS methods. This multilaboratory assessment demonstrates that the new reference material is an appropriate tool to determine the analytical parameters of different measurement methods and to ensure their quality assurance.


Assuntos
Biomarcadores Tumorais , DNA Tumoral Circulante , DNA de Neoplasias , Biópsia Líquida , Neoplasias/diagnóstico , Neoplasias/genética , Alelos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Sequenciamento de Nucleotídeos em Larga Escala/normas , Humanos , Biópsia Líquida/métodos , Biópsia Líquida/normas , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/normas , Garantia da Qualidade dos Cuidados de Saúde , Padrões de Referência
7.
Clin Chem ; 64(9): 1296-1307, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29903874

RESUMO

BACKGROUND: Genetic testing of tumor tissue and circulating cell-free DNA for somatic variants guides patient treatment of many cancers. Such measurements will be fundamental in the future support of precision medicine. However, there are currently no primary reference measurement procedures available for nucleic acid quantification that would support translation of tests for circulating tumor DNA into routine use. METHODS: We assessed the accuracy of digital PCR (dPCR) for copy number quantification of a frequently occurring single-nucleotide variant in colorectal cancer (KRAS c.35G>A, p.Gly12Asp, from hereon termed G12D) by evaluating potential sources of uncertainty that influence dPCR measurement. RESULTS: Concentration values for samples of KRAS G12D and wild-type plasmid templates varied by <1.2-fold when measured using 5 different assays with varying detection chemistry (hydrolysis, scorpion probes, and intercalating dyes) and <1.3-fold with 4 commercial dPCR platforms. Measurement trueness of a selected dPCR assay and platform was validated by comparison with an orthogonal method (inductively coupled plasma mass spectrometry). The candidate dPCR reference measurement procedure showed linear quantification over a wide range of copies per reaction and high repeatability and interlaboratory reproducibility (CV, 2%-8% and 5%-10%, respectively). CONCLUSIONS: This work validates dPCR as an SI-traceable reference measurement procedure based on enumeration and demonstrates how it can be applied for assignment of copy number concentration and fractional abundance values to DNA reference materials in an aqueous solution. High-accuracy measurements using dPCR will support the implementation and traceable standardization of molecular diagnostic procedures needed for advancements in precision medicine.


Assuntos
Reação em Cadeia da Polimerase/métodos , Medicina de Precisão , Variações do Número de Cópias de DNA , Humanos , Espectrometria de Massas , Reprodutibilidade dos Testes
8.
Biotechniques ; 64(2): 59-68, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29571283

RESUMO

We compared different methods (absorbance, fluorescent dye-binding, and digital PCR) for measuring the concentrations of human genomic DNA from cultured cells and absorbance measurements of a synthetic DNA oligonucleotide. NIST Standard Reference Material (SRM) 2082, a pathlength absorbance standard, was used to benchmark the absorbance measurements done with microvolume spectrophotometers and a microvolume plate reader. Control absorbance values were measured on a high accuracy spectrophotometer and a NIST calibrated pathlength cuvette. Measurements of the human genomic DNA sample were done with several types of fluorescent dye binding assays using different DNA calibrators. The fluorescent dye binding methods gave different results for genomic DNA depending upon the type of DNA calibrator and the fluorescent dye that was used. The human genomic DNA sample was also characterized by using six different droplet digital PCR assays (amplicons located on different chromosomes) to measure the average copy number. Conversion of the digital PCR data to copy numbers was sensitive to the droplet size used for calculations and conversion to mass concentration was dependent upon the molecular weight of the human genome used for the calculations. The results from the different methods were compared and the caveats for each measurement method were discussed.


Assuntos
DNA/análise , Oligonucleotídeos/análise , Fluorometria , Humanos , Reação em Cadeia da Polimerase , Espectrofotometria
9.
Biopharm Int ; 31(4): 22-34, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30996711

RESUMO

Ultraviolet (UV) absorbance measurements provide a rapid and reliable method to determine protein concentrations. the National Institute of standards and technology (NIST) has developed Standard Reference Material (SRM) 2082 as a pathlength standard for UV absorbance measurements for use with the new generation of microvolume spectrophotometers and short-pathlength cuvettes. short pathlengths are used with high-concentration targets to ensure that absorbance values are within the optimal range. the short-pathlength instruments and cuvettes also reduce the required volumes to conserve valuable samples. the authors compared the results obtained with high-quality dual-beam spectrophotometers and short-pathlength cuvettes to the results obtained from a microvolume spectrophotometer and a microvolume plate reader. SRM 2082 can be used to accurately calculate pathlength values, thereby increasing the accuracy in subsequent measurements using the short-pathlength cuvettes and microvolume absorbance instruments. RM 8671 (reference material, the NISTmAb) can then be used to ensure the accuracy and reproducibility of protein concentration measurements by providing an industrially relevant reference material, a well-characterized monoclonal antibody.

10.
PLoS One ; 12(11): e0188085, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29145448

RESUMO

Droplet digital PCR (ddPCR) is being advocated as a reference method to measure rare genomic targets. It has consistently been proven to be more sensitive and direct at discerning copy numbers of DNA than other quantitative methods. However, one of the largest obstacles to measuring microRNA (miRNA) using ddPCR is that reverse transcription efficiency depends upon the target, meaning small RNA nucleotide composition directly effects primer specificity in a manner that prevents traditional quantitation optimization strategies. Additionally, the use of reagents that are optimized for miRNA measurements using quantitative real-time PCR (qRT-PCR) appear to either cause false positive or false negative detection of certain targets when used with traditional ddPCR quantification methods. False readings are often related to using inadequate enzymes, primers and probes. Given that two-step miRNA quantification using ddPCR relies solely on reverse transcription and uses proprietary reagents previously optimized only for qRT-PCR, these barriers are substantial. Therefore, here we outline essential controls, optimization techniques, and an efficacy model to improve the quality of ddPCR miRNA measurements. We have applied two-step principles used for miRNA qRT-PCR measurements and leveraged the use of synthetic miRNA targets to evaluate ddPCR following cDNA synthesis with four different commercial kits. We have identified inefficiencies and limitations as well as proposed ways to circumvent identified obstacles. Lastly, we show that we can apply these criteria to a model system to confidently quantify miRNA copy number. Our measurement technique is a novel way to quantify specific miRNA copy number in a single sample, without using standard curves for individual experiments. Our methodology can be used for validation and control measurements, as well as a diagnostic technique that allows scientists, technicians, clinicians, and regulators to base miRNA measures on a single unit of measurement rather than a ratio of values.


Assuntos
MicroRNAs/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , Linhagem Celular , DNA Complementar/biossíntese , Humanos , Temperatura
11.
Biotechnol Prog ; 33(3): 677-686, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28371560

RESUMO

Differential scanning calorimetry (DSC) and differential scanning fluorimetry (DSF) were used to measure the transition temperatures of four proteins: RNase A, invertase, rituximab, and the NISTmAb (NIST Reference Material, RM 8671). The proteins were combined with several different fluorescent dyes for the DSF measurements. This study compares the results of DSC and DSF measurements of transition temperatures with different types of proteins, dye combinations, and thermal scan rates. As protein unfolding is often influenced by kinetic effects, we measured the transition temperatures of the proteins using DSC over a range of temperature scan rates and compared them to the data obtained from DSF over comparable temperature scan rates. The results when the proteins were combined with Sypro Orange® and bis-ANS for the DSF measurements had the best correlations with the transition temperatures determined by calorimetry. The scan rate was found to be an important variable when comparing results between DSC and DSF. The van't Hoff enthalpy changes for the transitions were calculated from the DSC data by using a non-two-state model and from the DSF values using a two-state model. The calculated van't Hoff enthalpy changes did not show a good correlation between the two methods. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:677-686, 2017.


Assuntos
Anticorpos Monoclonais/química , Varredura Diferencial de Calorimetria/métodos , Fluorometria/métodos , Desdobramento de Proteína , Termodinâmica , Temperatura de Transição , beta-Frutofuranosidase/química , beta-Frutofuranosidase/metabolismo
12.
Artigo em Inglês | MEDLINE | ID: mdl-34877099

RESUMO

New spectrophotometers and cuvettes have been designed to allow the measurement of absorbance values from samples using microliter volume sizes. These measurements are done using short pathlengths to decrease the sample volumes required. The major applications for these spectrophotometers and cuvettes are samples that are difficult to obtain in large amounts, such as proteins and nucleic acids that absorb light in the ultraviolet range. Existing ultraviolet absorbance standards have been designed for longer pathlength measurements. Standard Reference Material (SRM) 2082 was developed to validate the pathlengths of short-pathlength cuvettes and instruments using materials with absorbance spectra that are similar to the most commonly used samples. SRM 2082 consists of three individual components: a blank buffer solution, a solution of the amino acid tryptophan in the buffer, and a solution of the nucleobase uracil in the buffer. The tryptophan solution has an absorbance spectrum (peak at 280 nm) similar to proteins, and the uracil has an absorbance spectrum (peak at 260 nm) similar to nucleic acids. The absorbance values of these solutions were determined using a series of cuvettes with pathlengths from 0.1 mm to 2 mm. The pathlengths of the cuvettes used for the absorbance measurements were determined at the National Institute of Standards and Technology by physical and optical measurements. The effects of temperature and spectral bandwidth variations on the absorbance values of SRM 2082 were also investigated.

13.
J Mol Diagn ; 18(5): 753-761, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27455875

RESUMO

The National Institute of Standards and Technology (NIST) Standard Reference Materials 2373 is a set of genomic DNA samples prepared from five breast cancer cell lines with certified values for the ratio of the HER2 gene copy number to the copy numbers of reference genes determined by real-time quantitative PCR and digital PCR. Targeted-amplicon, whole-exome, and whole-genome sequencing measurements were used with the reference material to compare the performance of both the laboratory steps and the bioinformatic approaches of the different methods using a range of amplification ratios. Although good reproducibility was observed in each next-generation sequencing method, slightly different HER2 copy numbers associated with platform-specific biases were obtained. This study clearly demonstrates the value of Standard Reference Materials 2373 as reference material and as a calibrator for evaluating assay performance as well as for increasing confidence in reporting HER2 amplification for clinical applications.


Assuntos
Amplificação de Genes , Sequenciamento de Nucleotídeos em Larga Escala , Receptor ErbB-2/genética , Padrões de Referência , Linhagem Celular Tumoral , Exoma , Feminino , Dosagem de Genes , Genoma Humano , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Sequenciamento de Nucleotídeos em Larga Escala/normas , Humanos , Masculino , Neoplasias/diagnóstico , Neoplasias/genética , Reação em Cadeia da Polimerase em Tempo Real
14.
PLoS Biol ; 14(6): e1002476, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27300367

RESUMO

Different genomic technologies have been applied to cell line authentication, but only one method (short tandem repeat [STR] profiling) has been the subject of a comprehensive and definitive standard (ASN-0002). Here we discuss the power of this document and why standards such as this are so critical for establishing the consensus technical criteria and practices that can enable progress in the fields of research that use cell lines. We also examine other methods that could be used for authentication and discuss how a combination of methods could be used in a holistic fashion to assess various critical aspects of the quality of cell lines.


Assuntos
Perfilação da Expressão Gênica/métodos , Técnicas de Genotipagem/métodos , Repetições de Microssatélites/genética , Polimorfismo de Nucleotídeo Único , Animais , Linhagem Celular , Código de Barras de DNA Taxonômico/métodos , Código de Barras de DNA Taxonômico/normas , Perfilação da Expressão Gênica/normas , Técnicas de Genotipagem/normas , Humanos , Padrões de Referência , Reprodutibilidade dos Testes
15.
Biomol Detect Quantif ; 8: 1-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27335805

RESUMO

NIST standard reference material (SRM) 2373 was developed to improve the measurements of the HER2 gene amplification in DNA samples. SRM 2373 consists of genomic DNA extracted from five breast cancer cell lines with different amounts of amplification of the HER2 gene. The five components are derived from the human cell lines SK-BR-3, MDA-MB-231, MDA-MB-361, MDA-MB-453, and BT-474. The certified values are the ratios of the HER2 gene copy numbers to the copy numbers of selected reference genes DCK, EIF5B, RPS27A, and PMM1. The ratios were measured using quantitative polymerase chain reaction and digital PCR, methods that gave similar ratios. The five components of SRM 2373 have certified HER2 amplification ratios that range from 1.3 to 17.7. The stability and homogeneity of the reference materials were shown by repeated measurements over a period of several years. SRM 2373 is a well characterized genomic DNA reference material that can be used to improve the confidence of the measurements of HER2 gene copy number.

16.
Biotechnol Prog ; 31(1): 62-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25270911

RESUMO

We have used differential scanning calorimetry (DSC) to determine the unfolding properties of commercial products of human serum albumin (HSA) prepared from pooled human blood, transgenic yeast, and transgenic rice. The initial melting temperatures (Tm1 ) for the unfolding transitions of the HSA products varied from 62°C to 75°C. We characterized the samples for purity, fatty acid content, and molecular weight. The effects of adding fatty acids, heat pasteurization, and a low pH defatting technique on the transition temperatures were measured. Defatted HSA has a structure with the lowest stability (Tm of ∼62°C). When fatty acids are bound to HSA, the structure is stabilized (Tm of ∼64-72°C), and prolonged heating (pasteurization at 60°C) results in a heat-stabilized structural form containing fatty acids (Tm of ∼75-80°C). This process was shown to be reversible by a low pH defatting step. This study shows that the fatty acid composition and bioprocessing history of the HSA commercial products results in the large differences in the thermal stability.


Assuntos
Desdobramento de Proteína , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Albumina Sérica/química , Albumina Sérica/metabolismo , Biotecnologia , Varredura Diferencial de Calorimetria , Dicroísmo Circular , Ácidos Graxos/química , Humanos , Concentração de Íons de Hidrogênio , Oryza/genética , Oryza/metabolismo , Proteínas Recombinantes/genética , Albumina Sérica/genética , Temperatura , Termodinâmica , Leveduras/genética , Leveduras/metabolismo
17.
Cytotechnology ; 66(1): 133-47, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23430347

RESUMO

The scientific community has responded to the misidentification of human cell lines with validated methods to authenticate these cells; however, few assays are available for nonhuman cell line identification. We have developed a multiplex polymerase chain reaction assay that targets nine tetranucleotide short tandem repeat (STR) markers in the mouse genome. Unique profiles were obtained from seventy-two mouse samples that were used to determine the allele distribution for each STR marker. Correlations between allele fragment length and repeat number were determined with DNA Sanger sequencing. Genotypes for L929 and NIH3T3 cell lines were shown to be stable with increasing passage numbers as there were no significant differences in fragment length with samples of low passage when compared to high passage samples. In order to detect cell line contaminants, primers for two human STR markers were incorporated into the multiplex assay to facilitate detection of human and African green monkey DNA. This multiplex assay is the first of its kind to provide a unique STR profile for each individual mouse sample and can be used to authenticate mouse cell lines.

18.
Clin Proteomics ; 11(1): 43, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25593565

RESUMO

BACKGROUND: In our previous study that characterized different human CD4+ lymphocyte preparations, it was found that both commercially available cryopreserved peripheral blood mononuclear cells (PBMC) and a commercially available lyophilized PBMC (Cyto-Trol™) preparation fulfilled a set of criteria for serving as biological calibrators for quantitative flow cytometry. However, the biomarker CD4 protein expression level measured for T helper cells from Cyto-Trol was about 16% lower than those for cryopreserved PBMC and fresh whole blood using flow cytometry and mass cytometry. A primary reason was hypothesized to be due to steric interference in anti- CD4 antibody binding to the smaller sized lyophilized control cells. METHOD: Targeted multiple reaction monitoring (MRM) mass spectrometry (MS) is used to quantify the copy number of CD4 receptor protein per CD4+ lymphocyte. Scanning electron microscopy (SEM) is utilized to assist searching the underlying reasons for the observed difference in CD4 receptor copy number per cell determined by MRM MS and CD4 expression measured previously by flow cytometry. RESULTS: The copy number of CD4 receptor proteins on the surface of the CD4+ lymphocyte in cryopreserved PBMCs and in lyophilized control cells is determined to be (1.45 ± 0.09) × 10(5) and (0.85 ± 0.11) × 10(5), respectively, averaged over four signature peptides using MRM MS. In comparison with cryopreserved PBMCs, there are more variations in the CD4 copy number in lyophilized control cells determined based on each signature peptide. SEM images of CD4+ lymphocytes from lyophilized control cells are very different when compared to the CD4+ T cells from whole blood and cryopreserved PBMC. CONCLUSION: Because of the lyophilization process applied to Cyto-Trol control cells, a lower CD4 density value, defined as the copy number of CD4 receptors per CD4+ lymphocyte, averaged over three different production lots is most likely explained by the loss of the CD4 receptors on damaged and/or broken microvilli where CD4 receptors reside. Steric hindrance of antibody binding and the association of CD4 receptors with other biomolecules likely contribute significantly to the nearly 50% lower CD4 receptor density value for cryopreserved PBMC determined from flow cytometry compared to the value obtained from MRM MS.

19.
Proteomics Clin Appl ; 7(1-2): 17-29, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23341234

RESUMO

Cancer is a heterogeneous disease characterized by changes in the levels and activities of important cellular proteins, including oncogenes and tumor suppressors. Genetic mutations cause changes in protein activity and protein expression levels that result in the altered metabolism, proliferation, and metastasis seen in cancer cells. The identification of the critical biochemical changes in cancer has led to advances in its detection and treatment. An important example of this is the measurement of human epidermal growth factor receptor 2 (HER2), where increased expression occurs in approximately 20-30% of breast cancer tumors. HER2 is a member of the epidermal growth factor receptor family and is an important biomarker expressed on the cell surface. Measurement of the HER2 levels in tumor cells provides diagnostic, prognostic, and treatment information, because a targeted therapeutic is available. The most common methods to measure HER2 levels are immunohistochemistry and in situ hybridization assays. The accurate and reliable measurements of the specific changes in protein biomarkers for detection and treatment of cancer are important challenges. This review is focused on efforts to improve the quantitation and reliability of cancer biomarkers by using standards and reference materials.


Assuntos
Biomarcadores Tumorais/análise , Biomarcadores Tumorais/normas , Neoplasias da Mama/diagnóstico , Receptor ErbB-2/análise , Neoplasias da Mama/terapia , Humanos , Imuno-Histoquímica , Hibridização In Situ
20.
Cytometry A ; 81(7): 567-75, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22539147

RESUMO

To transform the linear fluorescence intensity scale obtained with fluorescent microspheres to an antibody bound per cell (ABC) scale, a biological cell reference material is needed. Optimally, this material should have a reproducible and tight ABC value for the expression of a known clinical reference biomarker. In this study, we characterized commercially available cryopreserved peripheral blood mononuclear cells (PBMCs) and two lyophilized PBMC preparations, Cyto-Trol and PBMC-National Institute for Biological Standard and Control (NIBSC) relative to freshly prepared PBMC and whole blood samples. It was found that the ABC values for CD4 expression on cryopreserved PBMC were consistent with those of freshly obtained PBMC and whole blood samples. By comparison, the ABC value for CD4 expression on Cyto-Trol is lower and the value on PBMC-NIBSC is much lower than those of freshly prepared cell samples using both conventional flow cytometry and CyTOF™ mass cytometry. By performing simultaneous surface and intracellular staining measurements on these two cell samples, we found that both cell membranes are mostly intact. Moreover, CD4(+) cell diameters from both lyophilized cell preparations are smaller than those of PBMC and whole blood. This could result in steric interference in antibody binding to the lyophilized cells. Further investigation of the fixation effect on the detected CD4 expression suggests that the very low ABC value obtained for CD4(+) cells from lyophilized PBMC-NIBSC is largely due to paraformaldehyde fixation; this significantly decreases available antibody binding sites. This study provides confirmation that the results obtained from the newly developed mass cytometry are directly comparable to the results from conventional flow cytometry when both methods are standardized using the same ABC approach.


Assuntos
Antígenos/metabolismo , Linfócitos T CD4-Positivos/metabolismo , Citometria de Fluxo , Calibragem , Membrana Celular/metabolismo , Separação Celular , Fixadores/química , Formaldeído/química , Humanos , Permeabilidade , Polímeros/química , Coloração e Rotulagem , Fixação de Tecidos