Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Chem A ; 118(37): 8158-62, 2014 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-24512169

RESUMO

The alanate anion, AlH4(-), was generated in the gas phase using a pulsed arc cluster ionization source. Its photoelectron spectrum was then measured with 193 nm photons. The spectrum consists of a broad feature, spanning electron binding energies from 3.8 eV to over 5.3 eV. This band reflects the photodetachment transitions between the ground state of the AlH4(-) anion and the ground state of its thermodynamically unstable neutral counterpart, AlH4. The vertical detachment energy (VDE) of AlH4(-) was measured to be 4.4 eV. Additionally, VDE values were also computed in a comprehensive theoretical study and compared both with the previously computed value and with our experimentally determined value.

2.
Pacing Clin Electrophysiol ; 21(8): 1517-30, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9725149

RESUMO

The purpose of this study was to assess the feasibility of stent dilation of venous obstructions/occlusions to permit transvenous pacing lead implantation. Innominate vein or superior vena cava (SVG) obstruction may preclude the implantation of transvenous pacing leads. Patients with d-transposition of the great arteries, after a Mustard or Senning procedure, and children with previously placed transvenous pacing leads are at higher risk for this vascular complication. From May 1993 to January 1996, eight pediatric patients who underwent transvenous pacing lead implantation or replacement were found to have significant innominate vein or SVC obstruction or occlusion. Utilizing intravascular stents, a combined interventional and electrophysiological approach was used to relieve the venous obstruction and to permit implantation of a new transvenous pacing lead. Two patients had complete SVC occlusion requiring puncture through the obstruction with a transseptal needle. Vessel recanalization was achieved with balloon dilation and stent implantation. The remaining six patients had severe venous obstruction with a mean minimum diameter of 3.1 +/- 3.3 mm. The mean pressure gradient across the obstructed veins was 8.6 +/- 7.3 mmHg. Following implantation of 15 Palmaz P308 stents in eight vessels, the mean diameter increased to 14.2 +/- 1.9 mm and the mean pressure gradient across the stented vessels decreased to 1.0 +/- 2.0 mmHg. A transvenous pacing lead was implanted successfully through the stent(s) immediately or 6-8 weeks later. Innominate vein and SVC obstruction can be safely and effectively relieved with intravascular stents and permit immediate or subsequent transvenous pacing lead implantation.


Assuntos
Implante de Prótese Vascular , Veias Braquiocefálicas , Estimulação Cardíaca Artificial/métodos , Cateterismo/métodos , Eletrodos Implantados , Stents , Síndrome da Veia Cava Superior/terapia , Adolescente , Adulto , Veias Braquiocefálicas/diagnóstico por imagem , Cateterismo Cardíaco , Criança , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/etiologia , Constrição Patológica/terapia , Seguimentos , Humanos , Masculino , Flebografia , Estudos Retrospectivos , Síndrome da Veia Cava Superior/diagnóstico por imagem , Síndrome da Veia Cava Superior/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...