J Perinatol ; 21(6): 399-401, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11593377

RESUMO

We report a premature infant with disseminated fungal infection identified as Bipolaris spicifera. The infant was born at 23 4/7 weeks' gestation, weighing 780 g. At day of life (DOL) 7 erythematous areas on the back were noticed that progressed to black, necrotic skin lesions. A shave biopsy showed invasive fungal organisms that were identified by culture as B. spicifera. The lesions progressed despite aggressive surgical debridement and antifungal therapy. On autopsy, fungal organisms found throughout the internal organs confirmed disseminated disease with B. spicifera. This organism is now more often recognized as a human pathogen; however, this is the first reported case in a neonate.


Assuntos
Ascomicetos , Dermatomicoses/diagnóstico , Doenças do Prematuro/microbiologia , Micoses/diagnóstico , Desbridamento , Dermatomicoses/terapia , Evolução Fatal , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/terapia , Recém-Nascido de muito Baixo Peso , Pulmão/patologia , Micoses/terapia , Necrose
2.
ASAIO J ; 45(1): 109-12, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-9952019

RESUMO

Physiologic clotting of a dialysis circuit was achieved using an in vitro method. The closed loop method used a circuit filled with defibrinated bovine blood. To achieve clotting, a slow infusion (5-15 ml/hr) of ACD bovine plasma was performed. The rate and amount of infusion of the plasma allowed for careful control of the amount of clotting in the circuit and dialyzer. By varying these, a range of clotting (10-40% dialyzer volume reduction) was achieved in a timeframe of approximately 100 minutes. The results of the technique closely mimicked clinical examples of dialysis circuits in appearance. Residual blood clots were present in the venous drip chamber filter, in nonstreamlined areas of the bloodline (e.g., bond joint gaps), and throughout the dialyzer fibers and header space. As an additional check of clotting distribution, the performance of the dialyzers compared favorably with previously reported effects of reuse. Solute clearances decreased with the fiber bundle volumes (FBV) of the devices. Correlations of small molecular weight (MW) (urea, creatinine) clearances with FBV were linear, whereas middle MW (vitamin B12) clearances and the ultrafiltration coefficient (kUF) had nonlinear correlations. The results indicate that this clotting method can be used as a valuable tool for a qualitative in vitro assessment of a hemodialysis extracorporeal circuit.


Assuntos
Coagulação Sanguínea , Diálise Renal/métodos , Animais , Bovinos , Desenho de Equipamento , Circulação Extracorpórea , Modelos Lineares , Modelos Biológicos , Dinâmica não Linear , Análise de Regressão