Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Phys Rev Lett ; 132(12): 122701, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38579210

RESUMO

^{140}Ce(n,γ) is a key reaction for slow neutron-capture (s-process) nucleosynthesis due to being a bottleneck in the reaction flow. For this reason, it was measured with high accuracy (uncertainty ≈5%) at the n_TOF facility, with an unprecedented combination of a high purity sample and low neutron-sensitivity detectors. The measured Maxwellian averaged cross section is up to 40% higher than previously accepted values. Stellar model calculations indicate a reduction around 20% of the s-process contribution to the Galactic cerium abundance and smaller sizeable differences for most of the heavier elements. No variations are found in the nucleosynthesis from massive stars.

2.
Eur Phys J A Hadron Nucl ; 58(12): 239, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36514540

RESUMO

Neutron capture reaction cross sections on 74 Ge are of importance to determine 74 Ge production during the astrophysical slow neutron capture process. We present new resonance data on 74 Ge( n , γ ) reactions below 70 keV neutron energy. We calculate Maxwellian averaged cross sections, combining our data below 70 keV with evaluated cross sections at higher neutron energies. Our stellar cross sections are in agreement with a previous activation measurement performed at Forschungszentrum Karlsruhe by Marganiec et al., once their data has been re-normalised to account for an update in the reference cross section used in that experiment.

3.
Phys Rev Lett ; 125(14): 142701, 2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33064503

RESUMO

The neutron capture cross sections of several unstable nuclides acting as branching points in the s process are crucial for stellar nucleosynthesis studies. The unstable ^{171}Tm (t_{1/2}=1.92 yr) is part of the branching around mass A∼170 but its neutron capture cross section as a function of the neutron energy is not known to date. In this work, following the production for the first time of more than 5 mg of ^{171}Tm at the high-flux reactor Institut Laue-Langevin in France, a sample was produced at the Paul Scherrer Institute in Switzerland. Two complementary experiments were carried out at the neutron time-of-flight facility (n_TOF) at CERN in Switzerland and at the SARAF liquid lithium target facility at Soreq Nuclear Research Center in Israel by time of flight and activation, respectively. The result of the time-of-flight experiment consists of the first ever set of resonance parameters and the corresponding average resonance parameters, allowing us to make an estimation of the Maxwellian-averaged cross sections (MACS) by extrapolation. The activation measurement provides a direct and more precise measurement of the MACS at 30 keV: 384(40) mb, with which the estimation from the n_TOF data agree at the limit of 1 standard deviation. This value is 2.6 times lower than the JEFF-3.3 and ENDF/B-VIII evaluations, 25% lower than that of the Bao et al. compilation, and 1.6 times larger than the value recommended in the KADoNiS (v1) database, based on the only previous experiment. Our result affects the nucleosynthesis at the A∼170 branching, namely, the ^{171}Yb abundance increases in the material lost by asymptotic giant branch stars, providing a better match to the available pre-solar SiC grain measurements compared to the calculations based on the current JEFF-3.3 model-based evaluation.

4.
Phys Rev Lett ; 124(20): 206402, 2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32501104

RESUMO

Lead-halide perovskite (LHP) semiconductors are emergent optoelectronic materials with outstanding transport properties which are not yet fully understood. We find signatures of large polaron formation in the electronic structure of the inorganic LHP CsPbBr_{3} by means of angle-resolved photoelectron spectroscopy. The experimental valence band dispersion shows a hole effective mass of 0.26±0.02 m_{e}, 50% heavier than the bare mass m_{0}=0.17 m_{e} predicted by density functional theory. Calculations of the electron-phonon coupling indicate that phonon dressing of the carriers mainly occurs via distortions of the Pb-Br bond with a Fröhlich coupling parameter α=1.81. A good agreement with our experimental data is obtained within the Feynman polaron model, validating a viable theoretical method to predict the carrier effective mass of LHPs ab initio.

5.
Phys Rev Lett ; 121(4): 042701, 2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30095928

RESUMO

We report on the measurement of the ^{7}Be(n,p)^{7}Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n_TOF facility at CERN. This reaction plays a key role in the lithium yield of the big bang nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and they showed a large discrepancy between each other. The measurement was performed with a Si telescope and a high-purity sample produced by implantation of a ^{7}Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low energy, relative to current evaluations, in the region of BBN interest, the present results are consistent with the values inferred from the time-reversal ^{7}Li(p,n)^{7}Be reaction, thus yielding only a relatively minor improvement on the so-called cosmological lithium problem. The relevance of these results on the near-threshold neutron production in the p+^{7}Li reaction is also discussed.

6.
J Phys Condens Matter ; 29(46): 465901, 2017 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-29064822

RESUMO

Quantum EXPRESSO is an integrated suite of open-source computer codes for quantum simulations of materials using state-of-the-art electronic-structure techniques, based on density-functional theory, density-functional perturbation theory, and many-body perturbation theory, within the plane-wave pseudopotential and projector-augmented-wave approaches. Quantum EXPRESSO owes its popularity to the wide variety of properties and processes it allows to simulate, to its performance on an increasingly broad array of hardware architectures, and to a community of researchers that rely on its capabilities as a core open-source development platform to implement their ideas. In this paper we describe recent extensions and improvements, covering new methodologies and property calculators, improved parallelization, code modularization, and extended interoperability both within the distribution and with external software.

7.
Phys Rev Lett ; 117(15): 152701, 2016 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-27768364

RESUMO

The energy-dependent cross section of the ^{7}Be(n,α)^{4}He reaction, of interest for the so-called cosmological lithium problem in big bang nucleosynthesis, has been measured for the first time from 10 meV to 10 keV neutron energy. The challenges posed by the short half-life of ^{7}Be and by the low reaction cross section have been overcome at n_TOF thanks to an unprecedented combination of the extremely high luminosity and good resolution of the neutron beam in the new experimental area (EAR2) of the n_TOF facility at CERN, the availability of a sufficient amount of chemically pure ^{7}Be, and a specifically designed experimental setup. Coincidences between the two alpha particles have been recorded in two Si-^{7}Be-Si arrays placed directly in the neutron beam. The present results are consistent, at thermal neutron energy, with the only previous measurement performed in the 1960s at a nuclear reactor. The energy dependence reported here clearly indicates the inadequacy of the cross section estimates currently used in BBN calculations. Although new measurements at higher neutron energy may still be needed, the n_TOF results hint at a minor role of this reaction in BBN, leaving the long-standing cosmological lithium problem unsolved.

8.
Rev Sci Instrum ; 86(7): 073509, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233385

RESUMO

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing (6)Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

9.
Phys Rev Lett ; 110(2): 022501, 2013 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-23383895

RESUMO

The 63Ni(n,γ) cross section has been measured for the first time at the neutron time-of-flight facility n_TOF at CERN from thermal neutron energies up to 200 keV. In total, capture kernels of 12 (new) resonances were determined. Maxwellian averaged cross sections were calculated for thermal energies from kT=5-100 keV with uncertainties around 20%. Stellar model calculations for a 25M⊙ star show that the new data have a significant effect on the s-process production of 63Cu, 64Ni, and 64Zn in massive stars, allowing stronger constraints on the Cu yields from explosive nucleosynthesis in the subsequent supernova.

10.
Appl Radiat Isot ; 68(4-5): 643-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20096595

RESUMO

In 2002, an innovative neutron time-of-flight facility started operation at CERN: n_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n_TOF is presented, together with plans for new measurements related to nuclear industry.


Assuntos
Terapia por Captura de Nêutron/instrumentação , Terapia por Captura de Nêutron/métodos , Reatores Nucleares , Desenho de Equipamento , Análise de Falha de Equipamento , Nêutrons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Radiat Prot Dosimetry ; 137(3-4): 223-6, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19837683

RESUMO

An integrated system to evaluate the magnetic field generated by power lines exposure has been developed using a specific simulation model (PLEIA-EMF). This is part of a software toolset, subjected to internal suitability verifications and in-field validations. A state indicator related to each span has been determined using the data extracted from digital cartography, the magnetic field calculated by PLEIA and the number of people living in the nearest buildings. In this way, it is possible to determine eventual criticalities in the considered area, focusing attention on those cases with more considerable exposure levels and involving a higher number of people. A campaign of inspections has been planned using PLEIA simulations. The reliability of stored technical data and the real population exposure levels have been evaluated in critical cases, individuated through the following described methodology. The procedures leading to the indicator determination and the modalities of in situ inspections are here presented.


Assuntos
Instalação Elétrica/normas , Eletricidade , Exposição Ambiental/análise , Análise de Falha de Equipamento/normas , Guias como Assunto , Monitoramento de Radiação/métodos , Monitoramento de Radiação/normas , Carga Corporal (Radioterapia) , Campos Eletromagnéticos , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Humanos , Itália , Doses de Radiação
12.
Appl Radiat Isot ; 67(7-8 Suppl): S292-5, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19406649

RESUMO

The boron neutron capture therapy is mainly suited in the treatment of some tumor kinds which revealed ineffective to the traditional radiotherapy. In order to take advantage of such a therapeutic modality in hospital environments, neutron beams of suitable energy and flux levels provided by compact size facilities are needed. The advantages and drawbacks of several neutron beams are here analysed in terms of therapeutic gains. In detail the GEANT-3/MICAP simulations show that high tumor control probability, with sub-lethal dose at healthy tissues, can be achieved by using neutron beams of few keV energy having a flux of about 10(9) neutrons/(cm(2)s). To produce such a neutron beam, the feasibility of a proton accelerator is investigated. In particular an appropriate choice of the radiofrequency parameters (modulation, efficiency of acceleration, phase shift, etc.) allows the development of relatively compact accelerators, having a proton beam current of 30 mA and an energy of 2 MeV, which could eventually lead to setting up of hospital-based neutron facilities.


Assuntos
Terapia por Captura de Nêutron de Boro/instrumentação , Nêutrons/uso terapêutico , Aceleradores de Partículas , Fenômenos Biofísicos , Neoplasias Encefálicas/radioterapia , Desenho de Equipamento , Nêutrons Rápidos/uso terapêutico , Humanos , Método de Monte Carlo , Imagens de Fantasmas/estatística & dados numéricos , Prótons
13.
Phys Rev Lett ; 93(16): 161103, 2004 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-15524972

RESUMO

The151Sm(n,gamma)152Sm cross section has been measured at the spallation neutron facility n_TOF at CERN in the energy range from 1 eV to 1 MeV. The new facility combines excellent resolution in neutron time-of-flight, low repetition rates, and an unsurpassed instantaneous luminosity, resulting in rather favorable signal/background ratios. The 151Sm cross section is of importance for characterizing neutron capture nucleosynthesis in asymptotic giant branch stars. At a thermal energy of kT=30 keV the Maxwellian averaged cross section of this unstable isotope (t(1/2)=93 yr) was determined to be 3100+/-160 mb, significantly larger than theoretical predictions.

14.
Phys Rev Lett ; 91(9): 092701, 2003 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-14525177

RESUMO

The emission time chronology of neutrons, protons, and deuterons from the E/A=61 MeV 36Ar+27Al reaction is deduced from two-particle correlation functions.

15.
Health Phys ; 82(6): 840-6, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12046756

RESUMO

The use of the simulation tool GEANT for neutron transport at energies below 20 MeV is discussed, in particular with regard to shielding and dose calculations. The reliability of the GEANT/MICAP package for neutron transport in a wide energy range has been verified by comparing the results of simulations performed with this package in a wide energy range with the prediction of MCNP-4B, a code commonly used for neutron transport at low energy. A reasonable agreement between the results of the two codes is found for the neutron flux through a slab of material (iron and ordinary concrete), as well as for the dose released in soft tissue by neutrons. These results justify the use of the GEANT/MICAP code for neutron transport in a wide range of applications, including health physics problems.


Assuntos
Simulação por Computador , Nêutrons Rápidos , Materiais de Construção , Humanos , Ferro , Método de Monte Carlo , Física Nuclear , Imagens de Fantasmas , Doses de Radiação
16.
Phys Rev Lett ; 87(10): 102701, 2001 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-11531477

RESUMO

Experimental information has been derived from the neutron-proton correlation function in order to deduce the time sequence of neutrons and protons emitted at 45 degrees in the E/A = 45 MeV 58Ni + 27Al reaction.

17.
Phys Rev Lett ; 87(7): 072701, 2001 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-11497888

RESUMO

The energetic proton emission has been investigated as a function of the reaction centrality for the system (58)Ni + (58)Ni at 30A MeV. Extremely energetic protons (E(NN)(p) > or = 130 MeV) were measured and their multiplicity is found to increase almost quadratically with the number of participant nucleons, thus indicating the onset of a mechanism beyond one- and two-body dynamics.

18.
Phys Med ; 17 Suppl 1: 124-7, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11770527

RESUMO

The use of existing detecting systems developed for nuclear physics studies allows collecting data on particle and ion production cross-sections in reactions induced by Oxygen and Carbon beams, of interest for hadrontherapy and heavy-ion risk assessment. The MULTICS and GARFIELD apparatus, together with the foreseen experiments, are reviewed.


Assuntos
Carbono , Íons Pesados , Oxigênio , Monitoramento de Radiação/instrumentação , Desenho de Equipamento , Raios gama , Itália , Física Nuclear , Monitoramento de Radiação/métodos , Radioterapia , Medição de Risco , Voo Espacial
19.
Radiat Prot Dosimetry ; 97(4): 401-4, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11878428

RESUMO

For some years, the Italian Regional Agencies for Environmental Protection (ARPA) have been engaged in the evaluation of long-term exposure to 50 Hz magnetic fields for receptors close to power lines. In this study, experiences and procedures are suggested in order to estimate long-term exposure levels in the case of magnetic induction produced contemporaneously by different power lines. In the simplest cases, the influence of a single line is evaluated by verifying the correlation factor between the variation of the current in each line and the measured magnetic induction. When the prevalence of a single line is not clear and systematic, much additional data (voltage, current, phases and geometrical configuration) have to be considered. The case of a school in Livomo near two lines. placed on the same supports, is described and a range of the most probable exposure values is given, corresponding to the phase change of the two current fluxes.


Assuntos
Instalação Elétrica , Campos Eletromagnéticos , Exposição Ambiental/análise , Humanos
20.
Phys Med Biol ; 45(1): 49-58, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10661582

RESUMO

The optimal neutron energy for the treatment of deep-seated tumours using boron neutron capture therapy is studied by analysing various figures of merit. In particular, analysis of the therapeutic gain as a function of the neutron energy indicates that, with the currently available 10B carriers, the most useful neutrons for the treatment of deep-seated tumours, in particular glioblastoma multiforme, are those with an energy of a few keV. Based on the results of the simulations, a method is presented which allows us to evaluate the quality of epithermal neutron beams of known energy spectrum, thus allowing us to compare different neutron-producing reactions and beam-shaping assembly configurations used for accelerator-based neutron sources.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Encefálicas/radioterapia , Glioblastoma/radioterapia , Boro , Simulação por Computador , Humanos , Método de Monte Carlo , Nêutrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...