Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Law Biosci ; 11(1): lsae008, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855036

RESUMO

Researchers are rapidly developing and deploying highly portable MRI technology to conduct field-based research. The new technology will widen access to include new investigators in remote and unconventional settings and will facilitate greater inclusion of rural, economically disadvantaged, and historically underrepresented populations. To address the ethical, legal, and societal issues raised by highly accessible and portable MRI, an interdisciplinary Working Group (WG) engaged in a multi-year structured process of analysis and consensus building, informed by empirical research on the perspectives of experts and the general public. This article presents the WG's consensus recommendations. These recommendations address technology quality control, design and oversight of research, including safety of research participants and others in the scanning environment, engagement of diverse participants, therapeutic misconception, use of artificial intelligence algorithms to acquire and analyze MRI data, data privacy and security, return of results and managing incidental findings, and research participant data access and control.

2.
Sci Rep ; 13(1): 189, 2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36604467

RESUMO

Non-contrast head CT (NCCT) is extremely insensitive for early (< 3-6 h) acute infarct identification. We developed a deep learning model that detects and delineates suspected early acute infarcts on NCCT, using diffusion MRI as ground truth (3566 NCCT/MRI training patient pairs). The model substantially outperformed 3 expert neuroradiologists on a test set of 150 CT scans of patients who were potential candidates for thrombectomy (60 stroke-negative, 90 stroke-positive middle cerebral artery territory only infarcts), with sensitivity 96% (specificity 72%) for the model versus 61-66% (specificity 90-92%) for the experts; model infarct volume estimates also strongly correlated with those of diffusion MRI (r2 > 0.98). When this 150 CT test set was expanded to include a total of 364 CT scans with a more heterogeneous distribution of infarct locations (94 stroke-negative, 270 stroke-positive mixed territory infarcts), model sensitivity was 97%, specificity 99%, for detection of infarcts larger than the 70 mL volume threshold used for patient selection in several major randomized controlled trials of thrombectomy treatment.


Assuntos
Aprendizado Profundo , Acidente Vascular Cerebral , Humanos , Tomografia Computadorizada por Raios X , Acidente Vascular Cerebral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Infarto da Artéria Cerebral Média
3.
Sci Rep ; 12(1): 2154, 2022 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-35140277

RESUMO

Stroke is a leading cause of death and disability. The ability to quickly identify the presence of acute infarct and quantify the volume on magnetic resonance imaging (MRI) has important treatment implications. We developed a machine learning model that used the apparent diffusion coefficient and diffusion weighted imaging series. It was trained on 6,657 MRI studies from Massachusetts General Hospital (MGH; Boston, USA). All studies were labelled positive or negative for infarct (classification annotation) with 377 having the region of interest outlined (segmentation annotation). The different annotation types facilitated training on more studies while not requiring the extensive time to manually segment every study. We initially validated the model on studies sequestered from the training set. We then tested the model on studies from three clinical scenarios: consecutive stroke team activations for 6-months at MGH, consecutive stroke team activations for 6-months at a hospital that did not provide training data (Brigham and Women's Hospital [BWH]; Boston, USA), and an international site (Diagnósticos da América SA [DASA]; Brazil). The model results were compared to radiologist ground truth interpretations. The model performed better when trained on classification and segmentation annotations (area under the receiver operating curve [AUROC] 0.995 [95% CI 0.992-0.998] and median Dice coefficient for segmentation overlap of 0.797 [IQR 0.642-0.861]) compared to segmentation annotations alone (AUROC 0.982 [95% CI 0.972-0.990] and Dice coefficient 0.776 [IQR 0.584-0.857]). The model accurately identified infarcts for MGH stroke team activations (AUROC 0.964 [95% CI 0.943-0.982], 381 studies), BWH stroke team activations (AUROC 0.981 [95% CI 0.966-0.993], 247 studies), and at DASA (AUROC 0.998 [95% CI 0.993-1.000], 171 studies). The model accurately segmented infarcts with Pearson correlation comparing model output and ground truth volumes between 0.968 and 0.986 for the three scenarios. Acute infarct can be accurately detected and segmented on MRI in real-world clinical scenarios using a machine learning model.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...