Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-35776829

RESUMO

Arm movement recovery after stroke can improve with sufficient exercise. However, rehabilitation therapy sessions are typically not enough. To address the need for effective methods of increasing arm exercise outside therapy sessions we developed a novel armrest, called Boost. It easily attaches to a standard manual wheelchair just like a conventional armrest and enables users to exercise their arm in a linear forward-back motion. This paper provides a detailed design description of Boost, the biomechanical analysis method to evaluate the joint torques required to operate it, and the results of pilot testing with five stroke patients. Biomechanics results show the required shoulder flexion and elbow extension torques range from -25% to +36% of the torques required to propel a standard pushrim wheelchair, depending on the direction of applied force. In pilot testing, all five participants were able to exercise the arm with Boost in stationary mode (with lower physical demand). Three achieved overground ambulation (with higher physical demand) exceeding 2 m/s after 2-5 practice trials; two of these could not propel their wheelchair with the pushrim. This simple to use, dynamic armrest provides people with hemiparesis a way to access repetitive arm exercise outside of therapy sessions, independently right in their wheelchair. Significantly, Boost removes the requirements to reach, grip, and release the pushrim to propel a wheelchair, an action many individuals with stroke cannot complete.


Assuntos
Acidente Vascular Cerebral , Cadeiras de Rodas , Braço , Fenômenos Biomecânicos , Humanos , Ombro
2.
Sensors (Basel) ; 18(1)2018 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-29324653

RESUMO

The closure of the abdominal wall after making a laparotomy is a major challenge for surgeons, since a significant percentage of closures fail and incisional hernias rise. The suture has to withstand the forces required to close the incision, while not hindering the adequate wound healing progression. Currently, there is no surgical measuring device that could be used to determine the required closing forces, which can be very different depending on the patient. This paper presents a dynamometer to measure the tension forces to be applied while closing a surgical incision, and it simultaneously measures the distance between wound edges. It is a compass-like instrument. A mechanism between the two legs incorporates a load cell, whose signal is read by an electronic device that computes the values of the tension forces between wound edges. An angular position sensor at the pin joint between legs provides the distance between both sides of the incision. Measuring capabilities of the instrument prototype were verified at the laboratory. Thereafter, its functionality was demonstrated in experimental surgery tests. Therefore, the instrument could be very useful in clinical applications, assisting personalized surgical techniques.


Assuntos
Laparotomia , Parede Abdominal , Humanos , Técnicas de Sutura , Suturas , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...