1.
Lab Med ; 50(1): 73-77, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30085261

RESUMO

BACKGROUND: The PIFA PLUSS PF4 Rapid Assay (PIFA) is a rapid screening test used for the diagnosis of heparin-induced thrombocytopenia (HIT). OBJECTIVE: To determine the usefulness of this assay as a screening method in our institution. METHODS: A total of 159 specimens from patients with suspected HIT were included in our study. We simultaneously performed PIFA assay and confirmatory polyspecific enzyme-linked immunosorbent assay (ELISA). We subjected most of the specimens with false-negative results to serotonin release assay (SRA). RESULTS: The initial sensitivity and specificity of the PIFA assay were calculated as 27.3% and 71.5%, respectively. A total of 12 of 16 false-negative results were further tested using the SRA method. The revised sensitivity and specificity were 50.0% and 73.5%, respectively. CONCLUSIONS: Despite its appealing feature of yielding rapid results, the PIFA assay is inadequate as a sole screening test for HIT because of its high probability of missing many true cases of HIT.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Testes Hematológicos/métodos , Fator Plaquetário 4/sangue , Trombocitopenia/sangue , Ensaio de Imunoadsorção Enzimática/normas , Fibrinolíticos/efeitos adversos , Testes Hematológicos/normas , Heparina/efeitos adversos , Humanos , Fator Plaquetário 4/imunologia , Sensibilidade e Especificidade , Trombocitopenia/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...