Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(7): 2255-9, 2016 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-30036002

RESUMO

In order to realize real-time, online monitoring of the component of steel and other metal smelting process, we designed a remote double-pulse laser-induced breakdown spectroscopy (LIBS) analysis system which can realize non-contact remote measurement and component analysis for long distance sample. The paper first tests the system on solid standard steel samples, which provides basis for online monitoring the component of molten steel. The experimental results show:laser focal spot is about 1mm in long distance; double-pulse ablation depth is deeper than single pulse's; the optimum delay of double-pulse is non-consistent in different distances; the enhancement effect of double- pulse in 3.1 m is better than that in 2.1 m,and the maximum enhancement is 5.19 of Ti(Ⅰ) 319.99 nm; the calibration curve of R2 is about 0.99, RSD being less than 5%, RMSE being less than 0.021%, LOD being less than 500 ppm for most elements in 2.1 m, which is better than that in 3.1 m.

2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(2): 542-7, 2014 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-24822436

RESUMO

In the present paper both the partial least squares (PLS) method and the calibration curve (CC) method are used to quantitatively analyze the laser induced breakdown spectroscopy data obtained from the standard alloy steel samples. Both the major and trace elements were quantitatively analyzed. By comparing the results of two different calibration methods some useful results were obtained: for major elements, the PLS method is better than the CC method in quantitative analysis; more importantly, for the trace elements, the CC method can not give the quantitative results due to the extremely weak characteristic spectral lines, but the PLS method still has a good ability of quantitative analysis. And the regression coefficient of PLS method is compared with the original spectral data with background interference to explain the advantage of the PLS method in the LIBS quantitative analysis. Results proved that the PLS method used in laser induced breakdown spectroscopy is suitable for quantitative analysis of trace elements such as C in the metallurgical industry.

3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 32(4): 876-80, 2012 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-22715743

RESUMO

To realize auto-selection of analytical lines for quantitative analysis of materials with laser-induced breakdown spectroscopy, two parameters, i. e. the relative detected-to-theory intensity ratio (RDTIR) and wavelength difference of detected and theory (WDDT) were defined. The spectral lines seriously disturbed by self-absorption and spectral interference were excluded automatically by setting reasonable thresholds of RDTIR and WDDT. By analyzing the experimental data of high-alloy steel (GBW01605), the analytical lines of iron (Fe), chromium (Cr), nickel (Ni), manganese (Mn) and copper (Cu) were selected, and the results were in line with the principle of lines selection.

4.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(12): 3186-90, 2010 Dec.
Artigo em Chinês | MEDLINE | ID: mdl-21322202

RESUMO

The concentration of Mn and Si in different kinds of steels was determined by laser-induced breakdown spectroscopy (LIBS). The multivariate quadratic nonlinear function was adopted for calibration. Samples including common alloy steels, stainless steels and carbon tool steels were analyzed. The matrix effect was serious because of large difference in compositions of different kinds of steels and strong line overlaps in steel spectra. Therefore, the common calibration methods that only use one analytical line to calibrate the complex chemical compositions of alloy steels will lose much information. The multivariate calibration methods, however, can utilize more information of spectra, successfully reduce the matrix effect and improve the measurement repeatability and accuracy of LIBS. Compared with the common calibration method based on one analytical line, the relative standard deviation was reduced from above 20% to below 10%, and the accuracy was increased by more than 5 times for Mn and more than 6 times for Si.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...