Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 8(2): 76-92, 2007 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-17592457

RESUMO

The present study evaluates the performance of a newly released photon-beam dose calculation algorithm that is incorporated into an established treatment planning system (TPS). We compared the analytical anisotropic algorithm (AAA) factory-commissioned with "golden beam data" for Varian linear accelerators with measurements performed at two institutions using 6-MV and 15-MV beams. The TG-53 evaluation regions and criteria were used to evaluate profiles measured in a water phantom for a wide variety of clinically relevant beam geometries. The total scatter factor (TSF) for each of these geometries was also measured and compared against the results from the AAA. At one institute, TLD measurements were performed at several points in the neck and thoracic regions of a Rando phantom; at the other institution, ion chamber measurements were performed in a CIRS inhomogeneous phantom. The phantoms were both imaged using computed tomography (CT), and the dose was calculated using the AAA at corresponding detector locations. Evaluation of measured relative dose profiles revealed that 97%, 99%, 97%, and 100% of points at one institute and 96%, 88%, 89%, and 100% of points at the other institution passed TG-53 evaluation criteria in the outer beam, penumbra, inner beam, and buildup regions respectively. Poorer results in the inner beam regions at one institute are attributed to the mismatch of the measured profiles at shallow depths with the "golden beam data." For validation of monitor unit (MU) calculations, the mean difference between measured and calculated TSFs was less than 0.5%; test cases involving physical wedges had, in general, differences of more than 1%. The mean difference between point measurements performed in inhomogeneous phantoms and Eclipse was 2.1% (5.3% maximum) and all differences were within TG-53 guidelines of 7%. By intent, the methods and evaluation techniques were similar to those in a previous investigation involving another convolution-superposition photon-beam dose calculation algorithm in another TPS, so that the current work permitted an independent comparison between the two algorithms for which results have been provided.


Assuntos
Algoritmos , Modelos Biológicos , Fótons/uso terapêutico , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Aceleradores de Partículas , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Espalhamento de Radiação
2.
Int J Radiat Oncol Biol Phys ; 55(3): 633-44, 2003 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-12573750

RESUMO

PURPOSE: To compare the partially wide tangent (PWT) technique of breast and internal mammary chain irradiation with photon/electron (P/E) and standard tangent (ST) techniques in terms of dose homogeneity within breast and the dose to critical structures such as the heart and lung. METHODS AND MATERIALS: Sixteen left breast cancer patients underwent CT simulation. The breasts, lungs, heart, and internal mammary chain were contoured and treatment plans generated on a three-dimensional planning system (Helax-TMS). RESULTS: The mean dose to the left breast volume with the ST, P/E, and PWT techniques was 94.7%, 98.4%, and 96.5%, respectively (p = 0.029). The left lung received the lowest mean dose with the ST technique (13.9%) compared with PWT (22.8%) and P/E (24.3%). The internal mammary chain volume was most consistently treated with the PWT (mean dose 99%) vs. P/E (86%) and ST (38.4%) techniques. The heart received the least dose with ST (mean dose 6.7%) vs. PWT (10.3%) and P/E (19%). The PWT treated the greatest amount of contralateral breast (mean dose 5.8%) vs. ST (3.2%) vs. P/E (2.8%). CONCLUSION: The PWT technique treats the internal mammary chain with acceptable toxicity to major organs, especially the heart, and with reasonable dose homogeneity in patients with mastectomy or intact breasts.


Assuntos
Neoplasias da Mama/radioterapia , Imageamento Tridimensional/métodos , Irradiação Linfática/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Doenças Mamárias/prevenção & controle , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Cardiopatias/prevenção & controle , Humanos , Pneumopatias/prevenção & controle , Mastectomia Segmentar , Doses de Radiação , Lesões por Radiação/prevenção & controle , Radioterapia/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...