Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Am J Sports Med ; 50(12): 3244-3255, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36113005

RESUMO

BACKGROUND: Young patients undergoing anterior cruciate ligament (ACL) reconstruction (ACLR) are at a particularly high risk of graft ruptures compared with adults. Recent studies have demonstrated significant reductions in ACL graft rupture rates in high-risk adult populations when a lateral extra-articular procedure is performed, but comparative studies in pediatric and adolescent populations are currently lacking in the literature. PURPOSE/HYPOTHESIS: The purpose of this study was to compare the clinical outcomes of isolated ACLR versus combined ACLR and lateral extra-articular tenodesis (LET) when using the Arnold-Coker modification of the MacIntosh procedure in early adolescent patients. The hypothesis was that combined procedures would be associated with a significantly reduced risk of graft ruptures. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A retrospective analysis of consecutive early adolescent patients who underwent ACLR using a hamstring tendon autograft with or without the Arnold-Coker modification of the MacIntosh procedure was conducted. Patients with ≥1 additional risk factors for a graft rupture were offered LET in addition to ACLR (pivot-shift grade 2 or 3, high level of sporting activity defined as Tegner activity score ≥7, participation in pivoting sports, and Segond fractures). Clinical outcomes including graft rupture rates, patient-reported outcome measure scores (Knee injury and Osteoarthritis Outcome Score and subjective International Knee Documentation Committee), knee stability, return-to-sports rates, reoperation rates, and complications were assessed. Comparisons between variables were assessed with the chi-square or Fisher exact test for categorical variables and the Student or Wilcoxon test for quantitative variables. Multivariate analyses were undertaken to evaluate risk factors for a graft rupture. RESULTS: A total of 111 patients with a mean follow-up of 43.8 ± 17.6 months (range, 24-89 months) were included in the study; 40 patients underwent isolated ACLR, and 71 underwent ACLR + LET. The addition of LET to ACLR was associated with a significantly lower graft rupture rate compared with isolated ACLR (0.0% vs 15.0%, respectively; odds ratio, 15.91 [95% CI, 1.81-139.44]; P = .012). It was also associated with significantly better knee stability (pivot-shift grade 3: 0.0% vs 11.4%, respectively; P = .021) (side-to-side anteroposterior laxity difference >5 mm: 0.0% vs 17.1%, respectively; P = .003) and Tegner activity scores (7 vs 6, respectively; P = .010). There were no significant differences between the groups regarding the Patient Acceptable Symptom State for the patient-reported outcome measures, nor for any of the other outcome measures evaluated, and no differences in the rate of non-graft rupture related reoperations or complications. The ACLR + LET group exceeded the minimal clinically important difference with respect to the Tegner activity scale. CONCLUSION: In a retrospective comparative cohort study of adolescents, combined ACLR and LET was associated with a significantly lower graft rupture rate and no difference in non-graft rupture related reoperations or complications compared with isolated ACLR.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Tenodese , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Criança , Estudos de Coortes , Humanos , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Tenodese/métodos
2.
Am J Sports Med ; 50(2): 404-414, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34939890

RESUMO

BACKGROUND: Interest in the role of lateral extra-articular tenodesis (LET) in preventing rotatory instability and the pivot-shift phenomenon after anterior cruciate ligament reconstruction (ACLR) has been recently renewed. Nevertheless, there is still concern about overconstraint of the lateral compartment of the knee and the risk of subsequent osteoarthritis (OA). PURPOSE: The purpose of this retrospective study was to compare long-term subjective and objective outcomes and the rate of OA development between patients undergoing isolated ACLR (iACLR) with a hamstring tendon autograft and those with a combined Arnold-Coker modification of the McIntosh extra-articular procedure. Risk factors for long-term OA were evaluated. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: The study included 165 consecutive patients treated at a single center by ACLR. A total of 86 patients underwent iACLR (iACLR group) and 79 received combined intra- and extra-articular reconstruction (ACLR+LET). The International Knee Documentation Committee (IKDC), Lysholm, and Tegner activity scores were administered. Knee stability was tested through the Lachman test, the pivot-shift test, and the KT-1000 knee arthrometer test. A positive pivot-shift test (++/+++), laxity on the KT-1000, and referred giving-way episodes or revision ACLR were considered failures. Radiographic results were assessed according to the Fairbank, IKDC, and Kellgren-Lawrence scales. Radiographic evaluation included both the overall tibiofemoral joint and the medial and lateral compartment separately. A univariate and a multivariate logistic regression with penalized maximum likelihood was used to identify risks factors associated with long-term OA. RESULTS: The mean follow-up was 15.7 years. There were no statistically significant differences in subjective scores between the 2 groups. A side-to-side difference >5 mm on the KT-1000 arthrometer evaluation was found in 8 patients in the iACLR group and in 1 patient in the ACLR+LET group (P = .01). Nine cases of failure were found in the iACLR group and only 1 case was found in the ACLR+LET group (P = .0093). Patients in the iACLR group had a significantly higher OA grades than those in the ACLR+LET group for the overall tibiofemoral joint and the lateral compartment of the knee. No differences were found in the medial compartment. A higher level of lateral compartment OA was found in patients who received partial lateral meniscectomy in the iACLR group compared with those in the ACLR+LET group. Univariate and multivariate analysis results demonstrated that meniscectomy was the most significant factor for long-term OA development. CONCLUSION: A significantly higher risk of long-term OA was found with iACLR than with ACLR combined with the Arnold-Coker modification of the McIntosh extra-articular procedure. Knees with combined ACLR also had a significantly lower OA grade after partial lateral meniscectomy. Additionally, those undergoing combined ACLR had better knee stability and lower graft rupture rates at the long-term follow-up. Partial meniscectomy was the main risk factor negatively associated with OA changes.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Instabilidade Articular , Tenodese , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Reconstrução do Ligamento Cruzado Anterior/métodos , Estudos de Coortes , Humanos , Instabilidade Articular/etiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Tenodese/métodos
3.
J Orthop Case Rep ; 11(10): 53-57, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35415095

RESUMO

Introduction: The open-wedge high tibial osteotomy (OWHTO) is a common technique for the treatment of medial compartmental osteoarthritis of the knee. There are many options to fill the osteotomy site gap. The autologous graft donor site morbidity can be avoided using heterologous bone grafts which represent a valid alternative. Case Presentation: This case report is about a 52-year-old male with knee osteoarthritis and varus deformity. Due to stiffness, swelling, and painful limitation during daily life activities, the patient underwent OWHTO. The osteotomy gap was filled with an equine cancellous bone wedge and nanohydroxyapatite (NHA) bone paste augmentation. After 3 years, the OWTHO was converted to total knee arthroplasty and a bone biopsy of the previous graft site was performed. The histological examination presented non-viable bone areas surrounded by viable bone without inflammatory cells, suggesting the presence of residual non-viable bone from the bone substitute graft. Conclusion: The in vivo histology of the graft site after 3 years has shown that heterologous bone is a safe and valid choice as a scaffold for bone regeneration. Augmentation with NHA bone paste achieved good osteoinduction without an inflammatory reaction and good integration of the bone substitute insert.

4.
Knee ; 27(4): 1167-1175, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32711878

RESUMO

BACKGROUND: The aim of the present study was to confirm the effectiveness of adding nanohydroxyapatite (NHA) to a heterologous bone graft in open-wedge high tibial osteotomy (OWHTO) by measuring the bone density via multislice computed tomography (CT) of the tibial osteotomy gap in a mid-term follow-up (five years). METHODS: Twenty-six patients undergoing OWHTO were randomly assigned to two groups: a pure graft group (Group A), in which the osteotomy gap was filled with only heterologous bone graft, and an NHA group (Group B), in which the osteotomy gap was filled with heterologous bone graft and NHA. CT was performed within one week of the operation, after two months, after 12 months and after five years. CT volume acquired in Hounsfield units (HU) was measured on three planes. RESULTS: The normal bone density was 110.2 ± 11.7 HU. The value of mean density at five years in Group A was 296.8 ± 81.8 HU, while in Group B, it was 202.2 ± 45.1 HU, showing a density more similar to normal bone and greater bone uniformity inside the osteotomy. The difference between the two groups was statistically significant (p < 0.05). Furthermore, both groups showed excellent mid-term clinical outcomes without significant differences. CONCLUSIONS: This study revealed that absorbability and bone formation at the osteotomy site in the NHA group was significantly higher as compared with the pure graft group at five years postoperatively.


Assuntos
Substitutos Ósseos/uso terapêutico , Transplante Ósseo/métodos , Durapatita/uso terapêutico , Osteoartrite do Joelho/cirurgia , Osteotomia/métodos , Tíbia/cirurgia , Adulto , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nanopartículas , Osteoartrite do Joelho/diagnóstico por imagem , Tomografia Computadorizada por Raios X
5.
Knee Surg Sports Traumatol Arthrosc ; 28(10): 3142-3148, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31773203

RESUMO

PURPOSE: As the population ages, it is important to determine whether total knee arthroplasties (TKA)s are safe and beneficial in the octogenarian population. The aims of the present study were: (1) to assess the effect of comorbidities and age on the incidence of postoperative complications following TKA and (2) to evaluate the mid-term outcome of octogenarian patients. METHODS: A retrospective matched-paired analysis by gender, BMI and duration of follow-up was conducted on 206 patients older than 80 years and younger than 75 years between 2009 and 2016, undergoing primary TKA. The mean follow-up was 5 years. Outcome measures including Oxford Knee Score (OKS), Knee Society Score (KSS), Knee Society Function Score (KSFS), postoperative complications, length of stay (LOS) and survivorship were analysed. The association between complications and comorbidities was assessed using multivariable logistic regression after adjusting for age, Deyo-Charlson Comorbidity Index (D-CCI) and the American Society of Anesthesiologist's (ASA) physical status classification. RESULTS: In the multivariable models, D-CCI class is an independent predictor for postoperative cardiac complications, delirium and transfusion rate (OR ranging from 1.2 to 69.5 in respect to D-CCI reference class 0). Being ≥ 80 years old was associated with an increased risk of transfusion (OR 3.4; 95% CI 1.7-6.8) and 1.7-day increase in LOS (p < 0.001). Both groups showed significant improvement in postoperative knee scores following TKA. CONCLUSION: Octogenarians experienced good clinical results when compared to their younger counterparts. Comorbidities, rather than age itself, are responsible for the increase in postoperative morbidity. Preoperative risk assessment has to be optimized in order to reduce complications.


Assuntos
Artroplastia do Joelho/efeitos adversos , Transfusão de Sangue/estatística & dados numéricos , Comorbidade , Tempo de Internação/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/mortalidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Articulação do Joelho/cirurgia , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/etiologia , Período Pós-Operatório , Recuperação de Função Fisiológica , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Resultado do Tratamento
6.
Case Rep Orthop ; 2019: 9192347, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30956832

RESUMO

INTRODUCTION: Intra-articular ganglion cysts of the knee joint are rare and mostly incidental findings in magnetic resonance imaging (MRI) or arthroscopy. Posterior cruciate ligament (PCL) ganglion cyst in a child is an extremely rare finding, and to the best of our knowledge, only one case has been described in the literature. We report a case of a large intra-articular ganglion cyst of the knee arising from the PCL in an autistic child. CASE PRESENTATION: An 8-year-old Caucasian boy affected by autism presented with nontraumatic knee pain. His parents, observing child's gait, reported recurrent limp while walking, sometimes accompanied by knee locking. Clinical examination was hindered by the noncompliance of the patient and revealed painful limitation of terminal flexion and extension. MRI scans showed a large ganglion cyst located in the intercondylar notch. Arthroscopy confirmed an intrasubstance PCL ganglion cyst, extending both anteriorly and posteriorly. Complete excision of the cyst was performed, with full recovery of the child and no recurrence. CONCLUSION: In pediatric patients with pain or limited knee range of motion, physicians should consider the possibility of a ganglion cyst arising from the PCL, despite its rarity. Arthroscopic excision is a safe and effective procedure that guarantees a complete recovery of the patient with the lowest rate of recurrence.

7.
Int Orthop ; 43(1): 223-228, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30276447

RESUMO

AIM OF THE STUDY: To describe the surgical findings of the anterolateral complex in patients with the "unhappy triad" lesion of the knee. METHOD: One hundred and twenty-five consecutive patients presenting with acute anterior cruciate ligament (ACL) tears were selected for this study. Only cases, evaluated with a valgus stress test under fluoroscopy, with a medial opening more than 5 mm of the medial collateral ligament (MCL) were included in the study (11 patients). For the included cases, open MCL surgical repair was performed only in cases with a valgus stress test more than 10 mm as revealed by fluoroscopy (3 patients). All included cases (11 patients) underwent ACL reconstruction and exploration of the anterolateral complex that was then assessed, photographed, classified, and eventually repaired. RESULTS: At clinical evaluation under anaesthesia, all patients presented a positive Lachman test and a pivot shift test graded as ++ in four cases and +++ in five cases, not valuable in two cases. At surgical exploration, the anterolateral complex was involved in all cases (11 patients): one case demonstrated a type I injury, eight cases a type II injury, two cases a type III injury, and no patient with a type IV injury (Segond's fracture). All anterolateral complex lesions were repaired by direct suture and re-tensioning. DISCUSSION: On the basis of a recent analysis performed by other authors, we could speculate that injuries of ACL and anterolateral compartment occur in the very early phase of the injury when the knee is forced into internal rotation. The MRI evidence of bone bruising in the lateral compartment in most cases of the present series support the hypothesis of an internal rotation torque. CONCLUSIONS: The unhappy triad of injuries to the knee is actually a tetrad involving not just the ACL, MCL, and medial/lateral meniscus but also involved the anterolateral complex.


Assuntos
Instabilidade Articular/cirurgia , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/cirurgia , Feminino , Humanos , Instabilidade Articular/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Ligamentos Articulares/cirurgia , Masculino , Amplitude de Movimento Articular , Lesões do Menisco Tibial/diagnóstico por imagem , Lesões do Menisco Tibial/cirurgia , Adulto Jovem
8.
Int Orthop ; 42(5): 1043-1049, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29532113

RESUMO

PURPOSE: To evaluate functional and radiological results in patients older than 50 years who underwent an anatomic anterior cruciate ligament (ACL) reconstruction with semitendinosus and gracilis tendons and to compare these results with those of patients younger than 40 years. METHODS: Thirty-six patients over the age of 50 years with a diagnosis of ACL complete lesion and 36 consecutive patients under 40 years were included in this prospective study. Follow-up included clinical evaluation using Lysholm, IKDC, and Tegner scores and a KT-1000 arthrometric evaluation. Bilateral weight-bearing radiographs were obtained before surgery and at final follow-up of five years to evaluate the degree of osteoarthritis. All patients were evaluated at a one year follow-up (T1) (range 13-17 months) and at final follow-up (T2) (range 60-72 months). RESULTS: No statistically significant difference was found between the two groups at the subjective and objective evaluations. At a KT-1000 arthrometric evaluation, the mean side to side maximum manual difference was 1.6 mm in the over 50 (group I) and 2.7 mm in the under 40 (group II) (p = 0.009). At 30 lb, the mean side to side difference was 1.7 mm in the over 50 group and 2.6 mm in the under 40 group (p = 0.040). No statistically significant increase in the degree of osteoarthritis was found at follow-up in the over 50 group. CONCLUSIONS: The results of this study seems to confirm that ACL reconstruction in patients older than 50 years is a safe procedure with good to excellent subjective, objective, and radiological outcomes that are comparable to those for younger patients.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Adulto , Fatores Etários , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Traumatismos em Atletas/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
9.
Orthop J Sports Med ; 6(8): 2325967118792263, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31457062

RESUMO

BACKGROUND: Increased femoral tunnel widening and weakness of the hamstring muscles postoperatively have been described as potential adverse events after anterior cruciate ligament (ACL) reconstruction (ACLR) with a hamstring graft. Meniscectomy and cartilage lesions are important factors for the development of degenerative osteoarthritis. PURPOSE: To compare 15-year follow-up data with 5-year follow-up data from the same cohort of patients after ACLR with a hamstring autograft using an outside-in technique. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A total of 72 patients who underwent anatomic ACLR with a quadruple hamstring graft and an outside-in technique were selected for this prospective study. Patients were reviewed at a minimum follow-up of 15 years. Results were compared with the same series of patients previously reviewed at 5 years after surgery. Lysholm, International Knee Documentation Committee (IKDC), and Tegner scores as well as KT-1000 arthrometer measurements were obtained at final follow-up. Comparative weightbearing radiographs were obtained and analyzed according to the Fairbank, Kellgren-Lawrence, and IKDC classifications and used for the tunnel evaluation. RESULTS: No significant difference was detected on the subjective evaluation. Objectively, patients categorized as A or B according to the IKDC score were not significantly different at 5 and 15 years (P < .01). A KT-1000 arthrometer side-to-side manual maximum difference >5 mm, a pivot shift >2+, any giving-way episode, and ACL revision surgery were considered as failures, and these were noted in 6 patients at 5 years and 6 patients at 15 years. The radiological evaluation at 15 years showed a higher rate of osteoarthritis in 2 of 3 radiological scales used in the study compared with results at 5-year follow-up (P < .01). At 15-year follow-up, there was a statistically significant reduction in the mean tibial tunnel diameter (P < .01). CONCLUSION: Endoscopic single-bundle ACLR using hamstring grafts and an outside-in technique demonstrated good results at 15-year follow-up in terms of subjective, objective, and radiographic evaluations. As compared with 5-year follow-up, clinical results remained stable both subjectively and objectively. However, a progression of osteoarthritis changes was observed, especially in patients in whom meniscectomy had been performed.

10.
Arthroscopy ; 32(10): 2039-2047, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27157658

RESUMO

PURPOSE: To determine whether an anterior cruciate ligament (ACL)-reconstructed knee with hamstring autograft has a greater incidence of degenerative changes when an extra-articular reconstruction is added and to determine the effect of the combined reconstruction on knee stability and function at long-term follow-up. METHODS: For this retrospective study, patients who underwent ACL reconstruction between January 2002 and December 2003 were selected and classified into 2 groups, I and II. Group I consisted of patients operated by a standard ACL reconstruction, and group II consisted of patients in whom, owing to the presence of risk factors (severe pivot shift graded +++ or high-risk sports), an extra-articular reconstruction performed with ileo-tibial tract according to McIntosh as modified by Cocker Arnold technique, was used in conjunction with intra-articular ACL reconstruction. At final follow-up, Lysholm, International Knee Documentation Committee (IKDC), and Tegner scores were used. An arthrometric KT-1000 evaluation was done. Comparative weight-bearing radiographs were taken, including a skyline view for the patellofemoral joint and analyzed according to Fairbank, Kellgren, and IKDC classification. RESULTS: Seventy-two of the 75 (96%) patients in group I and 68 of the 75 patients in group II were available at the final follow-up (minimum 10 years). Subjective scores improved significantly in both groups, with no significant difference. Objectively, the number of patients receiving C and D IKDC objective activity scores in group I (7/56; 12.5%) was significantly higher than in group II (0/60) (P = .01). Considering as a failure a side-to-side arthrometric difference more than 5 mm or a pivot shift test graded as ++ or +++, or any giving way episode occurring postoperatively, we found 8 cases in group I and no cases in group II (P = .01) despite the presence of risk factors that group I did not include. Radiologic evaluation showed less arthritic changes in group II in both tibiofemoral and patellofemoral joints. CONCLUSIONS: On the basis of the results of this study, adding an extra-articular reconstruction to an anatomically placed intra-articular ACL reconstruction, followed by a modern rehabilitation protocol, does not increase the risk of osteoarthritis and may be able to reduce the rate of failure. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Músculos Isquiossurais/transplante , Articulação do Joelho/cirurgia , Adolescente , Adulto , Artrometria Articular , Autoenxertos , Feminino , Seguimentos , Humanos , Escore de Lysholm para Joelho , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Avaliação de Resultados da Assistência ao Paciente , Modalidades de Fisioterapia , Cuidados Pós-Operatórios , Estudos Retrospectivos , Adulto Jovem
11.
Int Orthop ; 39(3): 461-6, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25300395

RESUMO

PURPOSE: The accelerometer-based system is a portable surgical navigation system for TKA that does not require the use of a large computer console for registration and alignment feedback as required in computer-assisted surgery (CAS). The purpose of this prospective study was to determine the accuracy of the accelerometer-based system in the tibial component positioning and also to evaluate clinical outcomes. METHODS: Between December 2011 and July 2012, a total of 53 consecutive patients with primary gonarthrosis were prospectively enrolled for unilateral TKA using a handheld surgical navigation system to perform the tibial resection. Pre-operatively and postoperatively, patients were asked to fill out a visual analogue scale for pain (VAS) and a knee injury and osteoarthritis outcome score (KOOS). Standing antero-posterior (AP) hip-knee-ankle (HKA) and lateral knee-to-ankle radiographs were performed to determine the varus/valgus alignment and the posterior slope of the tibial components relative to the mechanical axis. RESULTS: The mean duration of follow-up was 23 months. Average preoperative VAS was 8.3 ± 0.67, which significantly improved to a mean 1.2 ± 0.57 at final follow up (P < 0.001). All scores significantly increased compared with pre-operative scores, except for the KOOS sport component (P = 0.075) and quality of life (P = 0.19). Intra-operatively, the average reading provided by the system with regard to varus/valgus alignment before performing the tibial resection was 0.55° ± 0.43. The average postoperative radiographic alignment of the tibial component in the coronal plane was 0.65° ± 0.59 of deviation by the ideal alignment (P > 0.05). CONCLUSION: This study demonstrates that the OrthAlign navigation system combines the accuracy of the computer-assisted surgery systems with the ease of use and familiarity of the traditional instruments while avoiding the drawbacks of the CAS technique and disadvantages of conventional IM femoral alignment systems. The system could demonstrate an improvement in the incidence of outliers in final coronal alignment, as compared with a patient-specific cutting guide.


Assuntos
Acelerometria/métodos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Cirurgia Assistida por Computador/métodos , Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Radiografia
12.
Int Orthop ; 38(10): 2197-9, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25005461

RESUMO

PURPOSE: The use of available mechanical methods to measure anterior tibial translation (ATT) in anterior cruciate ligament (ACL)-deficient knees are limited by size and costs. This study evaluated the performance of a portable device based on a downloadable electronic smartphone application to measure ATT in ACL-deficient knees. METHODS: A specific smartphone application (SmartJoint) was developed for this purpose. Two independent observers nonsequentially measured the amount of ATT during execution of a maximum manual Lachman test in 35 patients with an ACL-deficient knee using KT 1000 and SmartJoint on both involved and uninvolved knees. As each examiner performed the test three times on each knee, a total of 840 measurements were collected. Statistical analysis compared intertest, interobserver and intra-observer reliability using the interclass correlation coefficient (ICC). An ICC > 0.75 indicates excellent reproducibility among measurements. RESULTS: Mean amount of ATT on uninvolved knees was 6.1 mm [standard deviation (SD = 2)] with the KT 1000 and 6.4 mm (SD = 2) with SmartJoint. Mean side-to-side difference was 8.1 mm. (SD = 4) with KT 1000 and 8.3 mm (SD = 3) with SmartJoint. Intertest reliability between the two methods yielded an ICC 0.797 [95 % confidence interval (CI) 0.717-0.857] for the uninvolved knee and of 0.987 (CI 0.981-0.991) for the involved knee. Interobserver ICC for SmartJoint and KT 1000 was 0.957 (CI 0.927-0.976) for the uninvolved knee and 0.992 (CI 0.986-0.996) for the involved knee and 0.973 (CI 0.954-0.985) for the uninvolved knee and 0.989 (CI 0.981-0.994) for involved knee, respectively. CONCLUSION: The performance of SmartJoint is comparable and highly correlated with measurements obtained from KT 1000. SmartJoint may provide a truly portable, noninvasive, accurate, reliable, inexpensive and widely accessible method to characterize ATT in ACL-deficient knee.


Assuntos
Lesões do Ligamento Cruzado Anterior , Artrometria Articular/instrumentação , Telefone Celular , Instabilidade Articular/diagnóstico , Traumatismos do Joelho/diagnóstico , Aplicativos Móveis , Reconstrução do Ligamento Cruzado Anterior , Humanos , Instabilidade Articular/cirurgia , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Exame Físico , Tíbia
13.
Am J Sports Med ; 42(7): 1669-74, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24799424

RESUMO

BACKGROUND: The pivot-shift test is considered a reliable examination to evaluate the results of anterior cruciate ligament (ACL) reconstruction, as it strongly correlates with patient satisfaction, giving-way episodes, and activity level. The addition of lateral tenodesis (LT) to current techniques of intra-articular reconstruction with a hamstring graft could potentially improve knee laxity in cases of severe rotational instability. PURPOSE: To biomechanically investigate the effect of intra- and extra-articular ACL reconstructions on knee laxity and the pivot-shift phenomenon. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty patients underwent anatomic single-bundle ACL reconstruction with doubled semitendinosus and gracilis tendons with the addition of extra-articular reconstruction. In patients in group A, intra-articular reconstruction was performed first and LT thereafter; in patients in group B, LT was performed first and intra-articular reconstruction thereafter. A navigator equipped with software designed for both static and dynamic evaluations was used to measure maximum anterior tibial translation (ATT) and axial tibial rotation (ATR) at 30° of flexion (static evaluation) and during the pivot-shift test (dynamic evaluation). Measurements were performed before reconstruction, after the first procedure, and after the second procedure. RESULTS: For the static evaluation, in group A, the mean ATT significantly decreased from 14.1 ± 3.7 mm in the preoperative (ACL-deficient) condition to 6.0 ± 1.9 mm after ACL reconstruction and to 5.3 ± 1.6 mm after LT. The mean ATR at 30° of knee flexion significantly decreased from 35.7° ± 4.8° to 28.9° ± 4.1° and to 20.9° ± 4.8°, respectively. In group B, the mean ATT significantly decreased from 13.5 ± 6.5 mm in the preoperative (ACL-deficient) condition to 10.2 ± 3.2 mm after LT and to 4.0 ± 1.6 mm after ACL reconstruction. The mean ATR at 30° of knee flexion significantly decreased from 36.7° ± 4.8° to 26.2° ± 6.2° and to 23.5° ± 4.9°, respectively. For the dynamic evaluation (pivot-shift test), in group A, the mean ATT significantly decreased from 15.0 ± 6.8 mm in the preoperative (ACL-deficient) condition to 9.4 ± 6.4 mm after ACL reconstruction and to 8.5 ± 5.4 mm after LT. The mean ATR significantly decreased from 16.9° ± 4.7° to 11.6° ± 4.1° and to 6.1° ± 2.2°, respectively. In group B, the mean ATT significantly decreased from 12.5 ± 3.3 mm in the preoperative (ACL-deficient) condition to 9.1 ± 5.9 mm after LT and to 8.1 ± 5.4 mm after ACL reconstruction. The mean ATR significantly decreased from 16.0° ± 4.5° to 9.2° ± 4.3° and to 7.5° ± 4.0°, respectively. CONCLUSION/CLINICAL RELEVANCE: Extra-articular reconstruction had little effect in reducing the anterior displacement of the tibia at 30° of flexion, but it was more effective than intra-articular reconstruction in reducing ATR. Anatomic ACL reconstruction and LT were synergic in controlling the pivot-shift phenomenon.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia , Tenodese/métodos , Adulto , Lesões do Ligamento Cruzado Anterior , Feminino , Humanos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Tíbia/cirurgia
15.
Int Orthop ; 38(2): 259-65, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24390008

RESUMO

PURPOSE: In recent years, patient-specific instruments (PSI) has been introduced with the aim of reducing the overall costs of the implants, minimising the size and number of instruments required, and also reducing surgery time. The purpose of this study was to perform a review of the current literature, as well as to report about our personal experience, to assess reliability of patient specific instrument system in total knee arthroplasty (TKA). METHODS: A literature review was conducted of PSI system reviewing articles related to coronal alignment, clinical knee and function scores, cost, patient satisfaction and complications. RESULTS: Studies have reported incidences of coronal alignment ≥3° from neutral in TKAs performed with patient-specific cutting guides ranging from 6% to 31%. CONCLUSIONS: PSI seem not to be able to result in the same degree of accuracy as the CAS system, while comparing well with standard manual technique with respect to component positioning and overall lower axis, in particular in the sagittal plane. In cases in which custom-made cutting jigs were used, we recommend performing an accurate control of the alignment before and after any cuts and in any further step of the procedure, in order to avoid possible outliers.


Assuntos
Artroplastia do Joelho/instrumentação , Prótese do Joelho/normas , Osteoartrite do Joelho/cirurgia , Pacientes , Ajuste de Prótese/normas , Cirurgia Assistida por Computador/instrumentação , Artroplastia do Joelho/métodos , Mau Alinhamento Ósseo/epidemiologia , Mau Alinhamento Ósseo/prevenção & controle , Análise Custo-Benefício , Humanos , Incidência , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Satisfação do Paciente , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
16.
Int Orthop ; 37(11): 2265-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23995333

RESUMO

PURPOSE: The aim of this study was to compare clinical and arthrometrical results of a series of patients older than 40 years with those of younger patients following anterior cruciate ligament (ACL) reconstruction. The hypothesis of this study was that certain biological and biomechanical factors related to middle-aged patients, ACL reconstruction would provide different results compared with younger patients. METHODS: Thirty-six patients >40 years operated for ACL reconstruction between 2002 and 2010 were selected for this retrospective study, and results were compared with patients in two other age groups (<30 years and 30-40 years). At a minimum follow-up of two years, patients were reviewed and clinically examined subjectively and objectively according to Tegner, International Knee Documentation Committee (IKDC) classification and Lysholm evaluation scales. An arthrometric evaluation with KT-1000 was also performed. RESULTS: No statistically significant difference was found among the three different age groups at the subjective and objective evaluations. However, the KT-1000 arthrometric study showed a statistically significant mean side-to-side difference at 30 lb with 1.8 mm [standard deviation (SD) 2.4] for patients >40 years, 2.7 mm (SD 1.8) for patients aged 30-40 years and 2.6 mm (SD 1.8) for patients <30 years. CONCLUSIONS: Our results seem to show that ACL reconstruction is a safe and valid option for patients of all age groups, even for those >40 years. Moreover, in that group, greater knee stability was found when compared with the younger patient groups.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Adulto , Fatores Etários , Artrometria Articular , Fenômenos Biomecânicos/fisiologia , Feminino , Seguimentos , Humanos , Instabilidade Articular/fisiopatologia , Articulação do Joelho/fisiologia , Masculino , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento
17.
Knee Surg Sports Traumatol Arthrosc ; 21(10): 2194-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22735977

RESUMO

PURPOSE: The aim of this study is to evaluate the accuracy of a patient-specific instrumentation (PSI) as assessed by the intraoperative use of knee navigation software during the surgical procedure. METHODS: Fifteen patients with primary gonarthrosis were selected for unilateral total knee arthroplasty. The first three patients were excluded from this study, as they were considered to be a warm up to set-up the procedure. All patients were operated on with a cemented posterior-stabilised prosthesis cruciate ligament-sacrificing by the same surgeon using the patient matched cutting jigs. The size of the implant, level of resection, and alignment in the coronal and sagittal planes were evaluated. An unsatisfactory result was considered an error ≥2° in both planes for each component as a possible error of 4° could result in aggravation. RESULTS: On the coronal plane the mean deviation of the tibial guide from the ideal alignment was 1.2 ± 1.5 (range 0-5°) and in the sagittal plane was 3.8 ± 2.4 (range 0-7.5°). On the coronal plane the mean deviation of the femoral guide from the ideal alignment was 1.2 ± 0.6 and in the sagittal was 3.7 ± 2. CONCLUSION: On the basis of this preliminary experience the PSI system based only on data acquisition with A-P radiograms and RMN cannot be defined as accurate. In cases of the use of the custom made cutting jigs it is recommended to perform an accurate control of the alignment before making the cuts, for any step of the procedure. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia do Joelho/métodos , Mau Alinhamento Ósseo/prevenção & controle , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Mau Alinhamento Ósseo/etiologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Ligamento Cruzado Posterior/cirurgia , Reprodutibilidade dos Testes , Software , Cirurgia Assistida por Computador/instrumentação , Resultado do Tratamento
18.
Knee Surg Sports Traumatol Arthrosc ; 21(3): 690-5, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22572869

RESUMO

PURPOSE: Due to the increasing number of primary anterior cruciate ligament (ACL) reconstructions, the need for revision surgery has risen. The aim of this study was to evaluate the use of contralateral doubled semitendinosus and gracilis tendon (DGST) for revision anterior cruciate ligament reconstruction. METHODS: Twelve patients undergoing revision ACL reconstruction with hamstring tendon were examined at an average follow-up of 3 years. All patients underwent a thorough subjective and objective evaluation, which included a KT-1000 arthrometric evaluation, and a radiographic examination. RESULTS: Subjective evaluation yielded a median score of 5.5 (range 2-9) on the Tegner activity scale. The mean Lysholm score was 95 (SD 9.5), and the mean subjective IKDC 2000 score was 95.4 (SD 7.8). At physical examination, a negative Lachman test was found in ten patients; one patient had a positive Lachman test with a firm end-point, and one other patient had a clearly positive Lachman test. Two patients had a grade 1+ on pivot shift testing. Only 1 patient showed a side-to-side difference more than 5 mm at the maximum manual KT-1000 arthrometer. Three patients (25 %) showed initial signs of osteoarthritis. CONCLUSIONS: The results of the study show that the use of hamstring tendons harvested from the unaffected knee represents a valid option for revision surgery following a failed primary ACL reconstruction using DGST grafts. LEVEL OF EVIDENCE: IV.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia , Tendões/transplante , Lesões do Ligamento Cruzado Anterior , Feminino , Humanos , Masculino , Reoperação , Transplante Autólogo , Adulto Jovem
19.
Int Orthop ; 36(8): 1589-93, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22426932

RESUMO

PURPOSE: The aim of this study is to evaluate the accuracy of VISIONAIRE (Smith & Nephew Inc., Memphis, TN, USA) Patient Matched cutting tibial jigs in comparison with extramedullary (EM) tibial instrumentation by analysing data as detected by intra-operative use of VectorVision knee navigation software from BrainLAB (Redwood City, CA, USA). METHODS: Twelve patients were selected for unilateral total knee replacement (TKR). They underwent a full-length weight-bearing anteroposterior (AP) radiograph and magnetic resonance imaging (MRI). During surgery, once the EM guides were placed and fixed on the tibia, the orientation in the coronal and sagittal planes was checked by the navigator and then compared with the data obtained by measuring the orientation of VISIONAIRE Patient Matched cutting tibial jigs. An unsatisfactory result was considered an error ≥2° in both coronal and sagittal planes for the tibial component as a possible error of 4° could result. RESULTS: In the coronal plane the mean deviation of the EM tibial guides from the ideal alignment (0°) was 0.7 ± 0.39° and of the VISIONAIRE was 129 ± 1.55° (P = 0.22). In the sagittal plane the mean deviation of the EM tibial guides from 3° of posterior slope was -1.62 ± 1.78° and of the VISIONAIRE was +1.16 ± 4.29° (P < 0.05). Negative values indicate a more posterior slope from the ideal and positive values an anterior slope. CONCLUSIONS: This preliminary study documented only a fair accuracy of the method with a consistent risk of error of more of 3° especially in the sagittal plane. We could speculate that the problem in the sagittal plane was due to the fact that the pre-operative protocol does not include a lateral X-ray projection of the knee and only includes an AP standing X-ray of the straight leg and MRI.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética/métodos , Software , Cirurgia Assistida por Computador/métodos , Tíbia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Mau Alinhamento Ósseo/epidemiologia , Mau Alinhamento Ósseo/prevenção & controle , Humanos , Incidência , Articulação do Joelho/diagnóstico por imagem , Masculino , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Suporte de Carga
20.
Knee Surg Sports Traumatol Arthrosc ; 19(3): 473-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20602086

RESUMO

This paper reports the results of our approach to ACL tears and knee laxity, based on 30 years of experience in ACL reconstruction with hamstrings and founded on the following cornerstones: the use of doubled semitendinosus and gracilis as a free graft; the use of an out-in technique for femoral drilling and of very strong and stiff fixation devices; the careful examination and repair or reconstruction of the lateral compartment in selected patients; and the use of unaggressive rehabilitation. We prospectively evaluated a series of 100 consecutive patients who underwent ACL reconstruction between 2001 and 2002. A clinical and radiological follow-up was performed at a minimum of 6 years. After 6 years, the International Knee Documentation Committee score demonstrated good-to-excellent results (A and B) in 98% of patients. However, arthrometric results using the KT-1000 demonstrated that 6/80 patients (7.5%) had >5 mm manual maximum side-to-side difference. The median Tegner activity score was 5 (range 1-9); the median Lysholm score was 96 (range 81-100); and the median subjective IKDC score was 94 (range 66-100). We reported 6/80 failures as revealed by a 2+ or 3+ pivot-shift test result and/or KT-1000 side-to-side difference of more than 5 mm. The IKDC score revealed excellent results in all women who underwent extra-articular tenodesis. Radiographic evaluation demonstrated early signs of osteoarthritis in 9% of patients.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Músculo Esquelético/transplante , Procedimentos de Cirurgia Plástica/métodos , Amplitude de Movimento Articular/fisiologia , Tendões/transplante , Adulto , Análise de Variância , Lesões do Ligamento Cruzado Anterior , Estudos de Coortes , Intervalos de Confiança , Feminino , Seguimentos , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Traumatismos do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Medição da Dor , Estudos Prospectivos , Procedimentos de Cirurgia Plástica/reabilitação , Recuperação de Função Fisiológica , Tenodese/métodos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...