1.
JTCVS Open ; 19: 175-182, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39015460

RESUMO

Objective: There is a paucity of data assessing the impact of nutritional status on outcomes in patients supported with the HeartMate 3 (HM3) left ventricular assist device (LVAD). Methods: Patients ≥18 years of age who underwent HM3 LVAD implantation between 2015 and 2020 were identified from a single tertiary care center. The primary outcome assessed was death or device replacement. A secondary outcome of driveline infection was also evaluated. Kaplan-Meier survival analysis and a multivariate Cox-proportional hazards model were used to identify predictors of outcome. Results: Of the 289 patients identified, 94 (33%) experienced a primary outcome and 96 (33%) a secondary outcome during a median follow-up time of 2.3 years. Independent predictors of the primary outcome included peripheral vascular disease (hazard ratio [HR], 3.40; 95% confidence interval [CI], 1.66-6.97, P < .01), diabetes mellitus (HR, 0.46; 95% CI, 0.27-0.80, P < .01), body mass index ≥40 kg/m2 (HR, 2.63 per 1 kg/m2 increase; 95% CI, 1.22-5.70, P < .05), preoperative creatinine level (HR, 1.86 per 1 mg/dL increase; 95% CI, 1.31-2.65, P < .01), and preoperative prognostic nutritional index (PNI) score (HR, 0.88 per 1-point increase; 95% CI, 0.81-0.96, P < .01). Independent predictors of driveline infection included age at the time of implantation (HR, 0.97; 95% CI, 0.96-0.99, P < .01) and diabetes mellitus (HR, 1.79; 95% CI, 1.17-2.73, P < .01). Conclusions: Preoperative PNI scores may independently predict mortality and the need for device replacement in patients with HM3 LVAD. Routine use of the PNI score during preoperative evaluation and, when possible, supplementation to PNI >33, may be of value in this population.

2.
J Cardiovasc Transl Res ; 16(3): 748-750, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36344902

RESUMO

The porcine intra-abdominal heterotopic heart transplantation model allows for the assessment of immunologic effects on cardiac transplantation without relying on the allograft to maintain hemodynamic support for the animal. Historically, allograft function and histology is monitored by physical exam, echocardiogram evaluation, percutaneous core biopsy, and open biopsy. We performed transvenous endomyocardial biopsies in three pigs that had undergone heterotopic heart implantation. We describe the procedure to be feasible and reproducible, and that histologic results from these biopsies correlated with those from corresponding tissue collected by surgical dissection at the time of allograft explantation. The ability to perform endomyocardial biopsies in the heterotopic heart transplantation model allows for serial non-invasive monitoring of allograft histology.


Assuntos
Transplante de Coração , Suínos , Animais , Humanos , Transplante de Coração/efeitos adversos , Miocárdio/patologia , Doadores de Tecidos , Coração , Biópsia/métodos , Rejeição de Enxerto
3.
J Surg Res ; 259: 106-113, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33279835

RESUMO

BACKGROUND: The data that exists regarding multiorgan procurement outcomes is conflicted. Given the increasing demand for pulmonary allografts, it is critical to assess the impact of dual procurement on lung transplant recipient outcomes. METHODS: The United Network for Organ Sharing transplant registry was queried for all first-time adult (age ≥18) lung transplant recipients between 2006 and 2018 and stratified by concurrent heart donor status. Multiorgan transplant recipients and recipients with missing survival time were excluded. Donors were excluded if they were donating after circulatory death, did not consent or were not approached for heart donation, the heart was recovered for nontransplant purposes, or the heart was recovered for transplant but not transplanted. Post-transplant survival was analyzed using the Kaplan-Meier method and multivariable Cox proportional hazards regression. RESULTS: A total of 18,641 recipients met inclusion criteria, including 6230 (33.4%) in the nonheart donor group (NHD) and 12,409 (66.6%) in the heart donor group (HD). HD recipients demonstrated longer survival at 10 years posttransplant, with a median survival of 6.5 years as compared with 5.9 years in NHD recipients. On adjusted analysis, HD and NHD recipients demonstrated comparable survival (AHR 0.95, 95% CI 0.90-1.01). CONCLUSIONS: Concomitant heart and lung procurement was not associated with worse survival. This finding encourages maximizing the number of organs procured from each donor, particularly in the setting of urgency-driven thoracic transplantation.


Assuntos
Sobrevivência de Enxerto , Transplante de Pulmão/efeitos adversos , Insuficiência Respiratória/cirurgia , Doadores de Tecidos/estatística & dados numéricos , Obtenção de Tecidos e Órgãos/métodos , Adulto , Idoso , Aloenxertos , Feminino , Transplante de Coração/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Transplante de Pulmão/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/mortalidade , Estudos Retrospectivos , Índice de Gravidade de Doença , Obtenção de Tecidos e Órgãos/classificação , Obtenção de Tecidos e Órgãos/estatística & dados numéricos , Transplantados/estatística & dados numéricos , Resultado do Tratamento , Adulto Jovem