Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Phys Eng Express ; 8(3)2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35038694

RESUMO

Quantification of physiological parameters in preclinical pharmacokinetic studies based on nuclear imaging requires the monitoring of arterial radioactivity over time, known as the arterial input function (AIF). Continuous derivation of the AIF in rodent models is very challenging because of the limited blood volume available for sampling. To address this challenge, an Ultra High Sensitivity Blood Counter (UHS-BC) was developed. The device detects beta particles in real-time using silicon photodiodes, custom low-noise electronics, and 3D-printed plastic cartridges to hold standard catheters. Two prototypes were built and characterized in two facilities. Sensitivities up to 39% for18F and 58% for11C-based positron emission tomography (PET) tracers were demonstrated.99mTc and125I based Single Photon Emission Computed Tomography (SPECT) tracers were detected with greater than 3% and 10% sensitivity, respectively, opening new applications in nuclear imaging and fundamental biology research. Measured energy spectra show all relevant peaks down to a minimum detectable energy of 20 keV. The UHS-BC was shown to be highly reliable, robust towards parasitic background radiation and electromagnetic interference in the PET or MRI environment. The UHS-BC provides reproducible results under various experimental conditions and was demonstrated to be stable over days of continuous operation. Animal experiments showed that the UHS-BC performs accurate AIF measurements using low detection volumes suitable for small animal models in PET, SPECT and PET/MRI investigations. This tool will help to reduce the time and number of animals required for pharmacokinetic studies, thus increasing the throughput of new drug development.


Assuntos
Radioatividade , Algoritmos , Animais , Partículas beta , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos
2.
J Nucl Med ; 57(9): 1460-6, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27151983

RESUMO

UNLABELLED: Small-animal nuclear imaging modalities have become essential tools in the development process of new drugs, diagnostic procedures, and therapies. Quantification of metabolic or physiologic parameters is based on pharmacokinetic modeling of radiotracer biodistribution, which requires the blood input function in addition to tissue images. Such measurements are challenging in small animals because of their small blood volume. In this work, we propose a microfluidic counting system to monitor rodent blood radioactivity in real time, with high efficiency and small detection volume (∼1 µL). METHODS: A microfluidic channel is built directly above unpackaged p-i-n photodiodes to detect ß-particles with maximum efficiency. The device is embedded in a compact system comprising dedicated electronics, shielding, and pumping unit controlled by custom firmware to enable measurements next to small-animal scanners. Data corrections required to use the input function in pharmacokinetic models were established using calibrated solutions of the most common PET and SPECT radiotracers. Sensitivity, dead time, propagation delay, dispersion, background sensitivity, and the effect of sample temperature were characterized. The system was tested for pharmacokinetic studies in mice by quantifying myocardial perfusion and oxygen consumption with (11)C-acetate (PET) and by measuring the arterial input function using (99m)TcO4 (-) (SPECT). RESULTS: Sensitivity for PET isotopes reached 20%-47%, a 2- to 10-fold improvement relative to conventional catheter-based geometries. Furthermore, the system detected (99m)Tc-based SPECT tracers with an efficiency of 4%, an outcome not possible through a catheter. Correction for dead time was found to be unnecessary for small-animal experiments, whereas propagation delay and dispersion within the microfluidic channel were accurately corrected. Background activity and sample temperature were shown to have no influence on measurements. Finally, the system was successfully used in animal studies. CONCLUSION: A fully operational microfluidic blood-counting system for preclinical pharmacokinetic studies was developed. Microfluidics enabled reliable and high-efficiency measurement of the blood concentration of most common PET and SPECT radiotracers with high temporal resolution in small blood volume.


Assuntos
Análise Química do Sangue/instrumentação , Dispositivos Lab-On-A-Chip , Tomografia por Emissão de Pósitrons/instrumentação , Radiometria/instrumentação , Compostos Radiofarmacêuticos/sangue , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Animais , Sistemas Computacionais , Avaliação Pré-Clínica de Medicamentos/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Camundongos Endogâmicos BALB C , Microquímica/instrumentação , Farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Lab Chip ; 12(22): 4683-92, 2012 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-23000896

RESUMO

New radiotracer developments for nuclear medicine imaging require the analysis of blood as a function of time in small animal models. A microfluidic device was developed to monitor the radioactivity concentration in the blood of rats and mice in real time. The microfluidic technology enables a large capture solid angle and a reduction in the separation distance between the sample and detector, thus increasing the detection efficiency. This in turn allows a reduction of the required detection volume without compromising sensitivity, an important advantage with rodent models having a small total blood volume (a few ml). A robust fabrication process was developed to manufacture the microchannels on top of unpackaged p-i-n photodiodes without altering detector performance. The microchannels were fabricated with KMPR, an epoxy-based photoresist similar to SU-8 but with improved resistance to stress-induced fissuring. Surface passivation of the KMPR enables non-diluted whole blood to flow through the channel for up to 20 min at low speed without clotting. The microfluidic device was embedded in a portable blood counter with dedicated electronics, pumping unit and computer control software for utilisation next to a small animal nuclear imaging scanner. Experimental measurements confirmed model predictions and showed a 4- to 19-fold improvement in detection efficiency over existing catheter-based devices, enabling a commensurate reduction in sampled blood volume. A linear dose-response relationship was demonstrated for radioactivity concentrations typical of experiments with rodents. The system was successfully used to measure the blood input function of rats in real time after radiotracer injection.


Assuntos
Sangue/metabolismo , Teste de Materiais , Técnicas Analíticas Microfluídicas/instrumentação , Compostos Radiofarmacêuticos/farmacocinética , Animais , Sangue/diagnóstico por imagem , Eletrodos , Desenho de Equipamento , Fluordesoxiglucose F18/farmacocinética , Camundongos , Tomografia por Emissão de Pósitrons , Radiografia , Ratos , Tomografia Computadorizada de Emissão de Fóton Único , Água/química
4.
J Nucl Med ; 48(7): 1197-206, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17574990

RESUMO

UNLABELLED: Radiotracer kinetic modeling in small animals with PET allows absolute quantification of physiologic and biochemical processes in vivo. It requires blood and tissue tracer concentrations as a function of time. Manual sampling, the reference method for blood tracer concentration measurements, requires fairly large amounts of blood besides being technically difficult and time-consuming. An automated microvolumetric beta blood counter (microBC) was designed to circumvent these limitations by measuring the blood activity in real time with PET scanning. METHODS: The microBC uses direct beta-particle detection to reduce its footprint and is entirely remote controlled for sampling protocol selection and real-time monitoring of measured parameters. Sensitivity has been determined for the most popular PET radioisotopes ((18)F, (13)N, (11)C, (64)Cu). Dispersion within the sampling catheter has been modeled to enable automatic correction. Blood curves obtained with the microBC were compared with manual samples and PET-derived data. The microBC was used to estimate the myocardial blood flow (MBF) of mice injected with (13)N-ammonia and to compare the myocardial metabolic rate of glucose (MMRG) of rats injected with (18)F-FDG for arterial and venous cannulation sites. RESULTS: The sensitivity limit ranges from 3 to 104 Bq/microL, depending on the isotope and the catheter used, and was found to be adequate for most small-animal studies. Automatic dispersion correction appears to be a good approximation of dispersion-free reference curves. Blood curves sampled with the microBC are well correlated with curves obtained from manual samples and PET images. With correction for dispersion, the MBF of anesthetized mice at rest was found to be 4.84 +/- 0.5 mL/g/min, which is comparable to values found in the literature for rats. MMRG values derived from the venous blood tracer concentration are underestimated by 60% as compared with those derived from arterial blood. CONCLUSION: The microBC is a compact automated counter allowing real-time measurement of blood radioactivity for pharmacokinetic studies in animals as small as mice. Reliable and reproducible, the device makes it possible to increase the throughput of pharmacokinetic studies with reduced blood sample handling and staff exposure, contributing to speed up new drug development and evaluation.


Assuntos
Compostos Radiofarmacêuticos/farmacocinética , Amônia/sangue , Amônia/farmacocinética , Animais , Partículas beta , Radioisótopos de Carbono , Radioisótopos de Cobre , Circulação Coronária , Feminino , Radioisótopos de Flúor , Fluordesoxiglucose F18/farmacocinética , Glucose/metabolismo , Coração/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos BALB C , Microfluídica , Modelos Biológicos , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...