Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 408(20): 4542-8, 2010 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20659757

RESUMO

Entry of contaminants, such as metals and non-metals, into rainwater harvesting systems can occur directly from rainfall with contributions from collection surfaces, accumulated debris and leachate from storage systems, pipes and taps. Ten rainwater harvesting systems on the east coast of Australia were selected for sampling of roof runoff, storage systems and tap outlets to investigate the variations in rainwater composition as it moved throughout the system, and to identify potential points of contribution to elemental loads. A total of 26 elements were screened at each site. Iron was the only element which was present in significantly higher concentrations in roof runoff samples compared with tank tap samples (P<0.05). At one case study site, results suggested that piping and tap material can contribute to contaminant loads of harvested rainwater. Increased loads of copper were observed in hot tap samples supplied by the rainwater harvesting system via copper piping and a storage hot water system (P<0.05). Similarly, zinc, lead, arsenic, strontium and molybdenum were significantly elevated in samples collected from a polyvinyl chloride pipe sampling point that does not supply household uses, compared with corresponding roof runoff samples (P<0.05). Elemental composition was also found to vary significantly between the tank tap and an internal cold tap at one of the sites investigated, with several elements fluctuating significantly between the two outlets of interest at this site, including potassium, zinc, manganese, barium, copper, vanadium, chromium and arsenic. These results highlighted the variability in the elemental composition of collected rainwater between different study sites and between different sampling points. Atmospheric deposition was not a major contributor to the rainwater contaminant load at the sites tested. Piping materials, however, were shown to contribute significantly to the total elemental load at some locations.


Assuntos
Conservação dos Recursos Naturais , Chuva/química , Oligoelementos/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental , Abastecimento de Água/análise
2.
Water Sci Technol ; 61(1): 25-36, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20057088

RESUMO

Chemical qualities of harvested rainwater were assessed at two residential study sites on the east coast of Australia in relation to coastal proximity and surrounding land uses over the course of a winter and summer month. Daily rainwater samples were collected from the base outlet and surface levels of stored water for chemical analyses. High resolution inductively coupled plasma-mass spectrometry (ICP-MS) was used to analyse 26 elements in all samples. The summer sampling regime for the industrial coastal Site 1 was dominated by wind gusts originating from the east with a total average elemental load of 25,900+/-17,000 microg/L compared to the significantly lower 10,600+/-3,370 microg/L measured during the winter month, where 84% of wind gust events originated from the west. Data for the inland Site 2, with no proximity to industry, revealed no significant changes in total average loads between the winter (4,870+/-578 microg/L) and summer (4,760+/-2,280 microg/L) months. The most abundant elements found at both sites included Na, K, Mg, and Zn. The rainwater storages at Site 2 fed from a relatively new concrete tiled roof catchment had significantly lower pH and conductivity measurements compared with those at Site 1 with an old galvanised iron roof catchment. It was concluded that seasonal differences in harvested water quality were likely influenced by prevailing wind direction and external influences such as surrounding land uses and proximity to the coast.


Assuntos
Estações do Ano , Abastecimento de Água/análise , Austrália , Clima , Magnésio/análise , Meteorologia , Potássio/análise , Chuva , Sódio/análise , Ressonância de Plasmônio de Superfície/métodos , Vento , Zinco/análise
3.
Water Sci Technol ; 55(4): 125-33, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17425079

RESUMO

The use of domestic rainwater tanks with back up from mains water supplies in urban areas can produce considerable reductions in mains water demands and stormwater runoff. It is commonplace to analyse the performance of rainwater tanks using continuous simulation with daily time steps and average water use assumptions. This paper compares this simplistic analysis to more detailed analysis that employs 6 minute time steps and climate dependent water demand. The use of daily time steps produced considerable under-estimation of annual rainwater yields that were dependent on tank size, rain depth, seasonal distribution of rainfall, water demand and tank configuration. It is shown that analysis of the performance of rainwater tanks is critically dependent on detailed inputs.


Assuntos
Simulação por Computador , Modelos Teóricos , Chuva , Conservação dos Recursos Naturais/métodos , Abastecimento de Água
4.
Water Sci Technol ; 55(4): 245-53, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17425092

RESUMO

Perceptions of the quality of roof harvested rainwater remain an impediment to widespread implementation of rainwater tanks on urban allotments. Previous literature reports on roof water quality have given little consideration to the relative significance of airborne environmental micro-organisms to roof catchment contamination and the issue of tank water quality. This paper outlines the findings of a recent study into the influence of weather on roof water contamination conducted at an urban housing development in Newcastle, on the east coast of Australia. Samples of direct roof run-off were collected during a number of separate rainfall events, and microbial counts were matched to climatic data corresponding to each of the monitored events. Roof run-off contamination was found to be under the strong influence of both wind speed and direction. The preliminary findings of an investigation currently under way into the microbial diversity of rainwater harvesting systems have also been presented. The results indicate that the composition of organisms present varied considerably from source to source and throughout the collection system. In all cases, evidence of faecal contamination was found to be negligible. The implications of these findings to the issues of tank water quality, health risk analysis and monitoring protocols have been discussed.


Assuntos
Chuva , Microbiologia da Água , Abastecimento de Água/normas , Conservação dos Recursos Naturais/métodos , Monitoramento Ambiental/métodos , Purificação da Água
5.
Water Res ; 40(1): 37-44, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16343588

RESUMO

The microbiological and chemical quality of tank-stored rainwater is impacted directly by roof catchment and subsequent run-off contamination, via direct depositions by birds and small mammals, decay of accumulated organic debris, and atmospheric deposition of airborne micro-organisms and chemical pollutants. Previous literature reports on roof water quality have given little consideration to the relative significance of airborne micro-organisms. This study involved analyses of direct roof run-off at an urban housing development in Newcastle, on the east coast of Australia. A total of 77 samples were collected during 11 separate rainfall events, and microbial counts and mean concentrations of several ionic contaminants were matched to climatic data corresponding to each of the monitored events. Conditions both antecedent to, and those prevailing during each event, were examined to investigate the influence of certain meteorological parameters on the bacterial composition of the roof water and indirectly assess the relative contribution of airborne micro-organisms to the total bacterial load. Results indicated that airborne micro-organisms represented a significant contribution to the bacterial load of roof water at this site, and that the overall contaminant load was influenced by wind velocities, while the profile (composition) of the load varied with wind direction. The implications of these findings to the issues of tank water quality and health risk analysis, appropriate usage and system design are discussed.


Assuntos
Bactérias/isolamento & purificação , Chuva , Abastecimento de Água/normas , Aerossóis , Monitoramento Ambiental , Habitação , Controle de Qualidade , Medição de Risco , Microbiologia da Água , Movimentos da Água
6.
Water Sci Technol ; 52(9): 1-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16445168

RESUMO

Integrated urban water cycle management presents a new framework in which solutions to the provision of urban water services can be sought. It enables new and innovative solutions currently constrained by the existing urban water paradigm to be implemented. This paper introduces the UrbanCycle model. The model is being developed in response to the growing and changing needs of the water management sector and in light of the need for tools to evaluate integrated watercycle management approaches. The key concepts underpinning the UrbanCycle model are the adoption of continuous simulation, hierarchical network modelling, and the careful management of computational complexity. The paper reports on the integration of modelling capabilities across the allotment, and subdivision scales, enabling the interactions between these scales to be explored. A case study illustrates the impacts of various mitigation measures possible under an integrated water management framework. The temporal distribution of runoff into ephemeral streams from a residential allotment in Western Sydney is evaluated and linked to the geomorphic and ecological regimes in receiving waters.


Assuntos
Conservação dos Recursos Naturais , Modelos Teóricos , Abastecimento de Água , Austrália , Cidades , Humanos , Estudos de Casos Organizacionais , Inovação Organizacional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...