Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 17(8): e0272248, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35913951

RESUMO

BACKGROUND: Healthcare facilities reprocess and sterilize reusable medical devices before each invasive clinical procedure, such as surgery, to prevent person-to-person or environmental transmission of pathogens through medical devices. We conducted a nationwide multi-centre cross-sectional survey in primary and secondary-care public hospitals in Nepal to assess the knowledge and attitudes of healthcare workers towards sterilization and reuse of medical devices. METHODS: We carried out a multi-centre cross-sectional survey comprising eleven primary-care (two district-level and nine district hospitals) and two secondary-care (zonal hospitals) public hospitals which covered all seven provinces of Nepal. Survey questionnaires were distributed to 234 healthcare workers including doctors, nurses, paramedics, and office assistants (involved in medical device reprocessing); 219 (93.6%) returned the completed questionnaire. Descriptive analyses of demographic information, knowledge and attitude responses of survey participants were performed. Logistic regression and ordinal regression models for complex samples were used to investigate associations between responses and independent variables. RESULTS: Except for a few areas, more than 70% of healthcare workers had proper knowledge about different aspects of sterilization and reuse of medical devices. Paramedics and office assistants were less likely to have the correct knowledge in different aspects compared to nurses. Permanent staff were more likely to give correct answers to some knowledge questions compared to temporary staff. Previous infection control training was positively associated with correct responses to some knowledge items. Most of the healthcare workers had positive attitudes towards different aspects of sterilization and reuse of medical devices, and nurses were more likely to have positive attitudes compared with other staff categories. CONCLUSIONS: Most of the healthcare workers had correct knowledge and positive attitudes towards most areas of sterilization and reuse of medical devices. However, they need proper education and training in some areas such as sterilization procedures, storage of sterilized devices, prion decontamination and standard precautions.


Assuntos
Pessoal de Saúde , Atenção Secundária à Saúde , Atitude , Estudos Transversais , Conhecimentos, Atitudes e Prática em Saúde , Hospitais Públicos , Humanos , Nepal , Esterilização/métodos , Inquéritos e Questionários
2.
BMC Health Serv Res ; 20(1): 923, 2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-33028325

RESUMO

BACKGROUND: Reusable medical devices in healthcare facilities are decontaminated and reprocessed following standard practices before each clinical procedure. Reprocessing of critical medical devices (those used for invasive clinical procedures) comprises several processes including sterilization, which provides the highest level of decontamination. Steam sterilization is the most used sterilization procedure across the globe. Noncompliance with standards addressing reprocessing of medical devices may lead to inadequate sterilization and thus increase the risk of person-to-person or environmental transmission of pathogens in healthcare facilities. We conducted nationwide multicenter clustered audits to understand the compliance of primary- and secondary-care public hospitals in Nepal with the standard practices for medical device reprocessing, including steam sterilization. METHODS: We developed an audit tool to assess compliance of hospitals with the standard practices for medical device reprocessing including steam sterilization. Altogether, 189 medical device reprocessing cycles which included steam sterilization were assessed in 13 primary and secondary care public hospitals in Nepal using the audit tool. Percentage compliance was calculated for each standard practice. Mean percentage compliances were obtained for overall primary and secondary care hospitals and for each hospital type, specific hospital and process involved. RESULTS: For all primary and secondary care hospitals in Nepal, the mean percentage compliance with the standard practices for medical device reprocessing including steam sterilization was 25.9% (95% CI 21.0-30.8%). The lower the level of care provided by the hospitals, the lower was the mean percentage compliance, and the difference in the means across the hospital types was statistically significant (p < 0.01). The mean percentage compliance of individual hospitals ranged from 14.7 to 46.0%. The hospitals had better compliance with the practices for cleaning of used devices and transport and storage of sterilized devices compared with the practices for other processes of the medical device reprocessing cycle. CONCLUSION: The primary and secondary care hospitals in Nepal had poor compliance with the standard practices for steam sterilization and reprocessing of medical devices. Interventions to improve compliance of the hospitals are immediately required to minimize the risks of person-to-person or environmental transmission of pathogens through inadequately reprocessed medical devices.


Assuntos
Reutilização de Equipamento , Equipamentos e Provisões , Fidelidade a Diretrizes/estatística & dados numéricos , Hospitais Públicos , Esterilização/normas , Guias como Assunto , Humanos , Auditoria Médica , Nepal , Atenção Primária à Saúde , Atenção Secundária à Saúde , Vapor , Esterilização/métodos
3.
PLoS One ; 14(11): e0225595, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31751421

RESUMO

BACKGROUND: Inadequate sterilization of reusable medical devices can lead to healthcare associated infections (HAIs) through person-to-person or environmental transmission of pathogens. Autoclaving (steam sterilization) is most commonly used for sterilizing medical devices in healthcare facilities. We conducted a nation-wide cross-sectional study to evaluate the effectiveness of steam sterilization practices in primary and secondary care public hospitals in Nepal and to identify factors associated with ineffective sterilization. METHODS: Using a stratified clustered random sampling, 13 primary- and secondary-care public hospitals in Nepal were selected. 189 steam sterilization cycles from these hospitals were evaluated for their effectiveness using self-contained biological indicators, class-5 chemical indicators, autoclave indicator tape and physical parameters. Information about the hospitals and the types of autoclaves being used was also collected. Data were analysed to estimate the proportion of ineffective steam sterilization cycles. Logistic regression was used to identify factors associated with ineffective sterilization. FINDINGS: In primary and secondary care public hospitals in Nepal, 71.0% (95% CI 46.8% - 87.2%) of the autoclave cycles were ineffective (i.e. showed positive results) when tested with biological indicators and 69.8% (95% CI 44.4% - 87.0%) showed 'reject' results with class 5 chemical indicators. There was no statistically significant difference in proportions showing positive or reject results by hospital types for either biological (p = 0.51) or class 5 chemical (p = 0.87) indicators. Autoclave type and pressure achieved during sterilization were statistically significantly associated with steam sterilization failures, adjusted for holding period, evenness of pressure and barrier system used. CONCLUSION: Primary and secondary care hospitals in Nepal have a high proportion of steam sterilization failure, indicating a risk of person-to-person transmission of pathogens through reusable medical devices. There is an urgent need to improve steam sterilization processes in these hospitals.


Assuntos
Contaminação de Equipamentos/prevenção & controle , Esterilização/métodos , Estudos Transversais , Equipamentos e Provisões , Hospitais Públicos , Humanos , Modelos Logísticos , Nepal , Centros de Cuidados de Saúde Secundários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...