Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Ind Med ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38837413

RESUMO

BACKGROUND: Engineered nanomaterials (ENMs) may pose health risks to workers. Objectives were to characterize ENM applications in construction, identify exposure scenarios, and evaluate the quality of safety data sheets (SDSs) for nano-enabled construction products. METHODS: SDSs and product data were obtained from a public database of nano-enabled construction products. Descriptive statistics were calculated for affected trades, product categories, and types of ENMs. A sample of SDSs (n = 33) was evaluated using modified criteria developed by NIOSH researchers. Bulk analysis via transmission electron microscopy characterized nanoparticles in a subset of products. RESULTS: Companies report using >50 ENMs in construction products. ENM composition could not be determined via SDSs for 38.1% of the 907 products examined. Polymers and metal oxides tied for most frequently reported ENMs (n = 87, 9.6%). Nano silica, graphene, carbon nanotubes, and silver nanoparticles were also frequently reported. Most of the products were paints and coatings (n = 483, 53.3%), followed by pre-market additives, cementitious materials, insulation, and lubricants. Workers in twenty construction trades are likely to handle nano-enabled products, these particularly encompass cement and brick masons, painters, laborers, carpenters, glaziers, and insulators. A wide range of exposure scenarios were identified. SDSs were classified as satisfactory (18%), in need of improvement (12%), or in need of significant improvement (70%). Bulk analyses revealed discrepancies between actual ENM composition and those in SDSs. DISCUSSION AND CONCLUSION: There has been significant progress investigating risks to construction workers posed by ENMs, but SDSs need major improvements. This study provides new insights on the use of ENMs in construction, exposure risks, and hazard communication.

2.
J Occup Environ Hyg ; 18(6): 237-249, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33989130

RESUMO

The study assessed potential to exceed occupational exposure limits while spraying paint with and without a silver nanoparticle biocidal additive. A tradesperson performed the tasks in a sealed chamber with filtered air supply. Integrated air sampling entailed transmission electron microscopy with energy dispersive X-ray analysis, direct-reading of particle number concentrations, and determination of silver mass concentration by NIOSH Method 7300. Silver nanoparticles were primarily embedded in paint spray droplets but also observed as isolated particles. Using an α-level of 0.05, median nanoparticle number concentrations did not differ significantly when spraying conventional vs. biocidal paint, although statistically significant differences were observed at specific particle size ranges <100 nm. The geometric mean concentration of total silver while spraying biocidal paint (n = 6) was 2.1 µg/m3 (95% CI: 1.5-2.8 µg/m3), and no respirable silver was detected (<0.50 µg/m3). The results address a lack of silver nanoparticle exposure data in construction and demonstrate the feasibility of a practical sampling approach. Given similar conditions, the measurements suggest a low probability of exceeding a proposed silver nanoparticle exposure limit of 0.9 µg/m3 as an airborne 8-hr time-weighted average respirable mass concentration. A full workday of exposure to respirable silver at the highest possible level in this study (<0.50 µg/m3) would not exceed the exposure limit, although limitations in comparing short task-based exposures to an 8-hr exposure limit must be noted. There was airflow in the study chamber, whereas exposure levels could increase over time in work environments lacking adequate ventilation. Potential to exceed the exposure limit hinged upon the respirable fraction of the paint mist, which could vary by material and application method. Additional research would improve understanding of silver nanoparticle exposure risks among construction trades, and biological responses to these exposures. Given the potential for exposure variability on construction jobsites, safety and health professionals should be cognizant of methods to assess and control silver nanoparticle exposures.


Assuntos
Poluentes Ocupacionais do Ar , Nanopartículas Metálicas , Exposição Ocupacional , Poluentes Ocupacionais do Ar/análise , Poluentes Ocupacionais do Ar/toxicidade , Monitoramento Ambiental , Exposição por Inalação/análise , Nanopartículas Metálicas/toxicidade , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Pintura/toxicidade , Prata/toxicidade
3.
J Occup Environ Hyg ; 16(5): 336-340, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31013200

RESUMO

Drilling large holes (e.g., 10-20 mm diameter) into concrete for structural upgrades to buildings, highways, bridges, and airport runways can produce concentrations of respirable silica dust well above the ACGIH® Threshold Limit Value (TLV® = 0.025 mg/m3). The aim of this study was to evaluate a new method of local exhaust ventilation, hollow bit dust extraction, and compare it to a standard shroud local exhaust ventilation and to no local exhaust ventilation. A test bench system was used to drill 19 mm diameter x 100 mm depth holes every minute for one hour under three test conditions: no local exhaust ventilation, shroud local exhaust ventilation, and hollow bit local exhaust ventilation. There were two trials for each condition. Respirable dust sampling equipment was placed on a "sampling" mannequin fixed behind the drill and analysis followed ISO and NIOSH methods. Without local exhaust ventilation, mean respirable dust concentration was 3.32 (± 0.65) mg/m3 with a quartz concentration of 16.8% by weight and respirable quartz dust concentration was 0.55 (± 0.05) mg/m3; 22 times the ACGIH TLV. For both LEV conditions, respirable dust concentrations were below the limits of detection. Applying the 16.8% quartz value, respirable quartz concentrations for both local exhaust ventilation conditions were below 0.007 mg/m3. There was no difference in respirable quartz dust concentrations between the hollow bit and the shroud local exhaust ventilation systems; both were below the limits of detection and well below the ACGIH TLV. Contractors should consider using either local exhaust ventilation method for controlling respirable silica dust while drilling into concrete.


Assuntos
Poluentes Ocupacionais do Ar/análise , Quartzo/análise , Ventilação/métodos , Indústria da Construção/instrumentação , Poeira/análise , Exposição por Inalação/análise , Exposição Ocupacional/prevenção & controle
4.
Appl Ergon ; 74: 31-36, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30487106

RESUMO

OBJECTIVES: Both pneumatic rock drills and electric rotary hammer drills are used for drilling large holes (e.g., 10-20 mm diameter) into concrete for structural upgrades to buildings, highways, bridges, and airport tarmacs. However, little is known about the differences in productivity, and exposures to noise, handle vibration, and dust between the two types of drills. The aim of this study was to compare these outcomes with similar mass electric rotary and pneumatic rock drills drilling into concrete block on a test bench system. METHOD: Three experiments were conducted on a test bench system to compare an electric (8.3 kg) and pneumatic drill (8.6 kg) on (1) noise and handle vibration, (2) respirable silica dust, and (3) drilling productivity. The test bench system repeatedly drilled 19 mm diameter x 100 mm depth holes into cured concrete block while the respective exposure levels were measured following ISO standards. RESULTS: Productivity levels were similar between the electric and the pneumatic drill (9.09 mm/s vs. 8.69 mm/s ROP; p = 0.15). However, peak noise (LPeak: 117.7 vs. 139.4 dBC; p = 0.001), weighted total handle vibration (ahw: 7.15 vs. 39.14 m/s2; p = 0.002), and respirable silica dust levels (0.55 vs. 22.23 mg/m3; p = 0.003) were significantly lower for the electric than the pneumatic drill. DISCUSSION: While there were no differences in drilling productivity between an electric and pneumatic drill of similar mass, there were substantial differences in exposure levels of noise, handle vibration, and respirable silica dust. Structural contractors should switch from pneumatic rock drills to electric rotary hammer drills for structural drilling into concrete in order to reduce worker exposures to the hazards of noise, hand vibration, and silica dust.


Assuntos
Indústria da Construção/instrumentação , Materiais de Construção/efeitos adversos , Poeira/análise , Exposição Ocupacional/análise , Vibração/efeitos adversos , Eficiência , Monitoramento Ambiental/métodos , Humanos , Manequins , Ruído Ocupacional
5.
J Occup Environ Hyg ; 16(3): 218-228, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30451647

RESUMO

The objectives of the study were to measure and characterize exposure to airborne nanoscale titanium dioxide during airless spraying and sanding of a nano-enabled paint, and to evaluate the effectiveness of dust capture methods in reducing airborne nanoparticle concentrations. A tradesperson performed the work activities in an environmentally controlled chamber. Samples were collected in the tradesperson's breathing zone and in surrounding areas to assess bystander exposure. Filter-based samples were analyzed using gravimetric methods, scanning electron microscopy, and energy dispersive spectroscopy. Differential particle count data were obtained by means of a scanning mobility particle sizer. Local exhaust ventilation provided statistically significant reductions of airborne nanoparticle concentrations during sanding. Sanding the paint after drying with a handheld power sander generated relatively low levels of airborne titanium dioxide. In contrast, task-based exposure measurements collected during the initial airless spray application of the nano-enabled paint suggested a potential for occupational exposures to exceed the time-weighted average exposure limit for ultrafine titanium dioxide recommended by the National Institute for Occupational Safety and Health. Painters applying nano-enabled coatings may have little recourse but to rely, in some instances, on lower tiers of the hierarchy of controls, such as personal protective equipment. In light of these findings, employers and industrial hygienists should characterize exposures and implement the hierarchy of controls to ensure painters are sufficiently protected.


Assuntos
Poluentes Ocupacionais do Ar/análise , Poeira/análise , Exposição por Inalação/análise , Exposição Ocupacional/análise , Pintura/análise , Titânio/análise , Adulto , Indústria da Construção , Monitoramento Ambiental/métodos , Humanos , Exposição por Inalação/prevenção & controle , Masculino , Concentração Máxima Permitida , Microscopia Eletrônica de Varredura , Nanopartículas , Exposição Ocupacional/prevenção & controle , Análise Espectral/métodos , Ventilação
6.
Ann Work Expo Health ; 61(6): 700-710, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28595322

RESUMO

OBJECTIVES: Hammer drills are used extensively in commercial construction for drilling into concrete for tasks including rebar installation for structural upgrades and anchor bolt installation. This drilling task can expose workers to respirable silica dust and noise. The aim of this pilot study was to evaluate the effects of bit wear on respirable silica dust, noise, and drilling productivity. METHOD: Test bits were worn to three states by drilling consecutive holes to different cumulative drilling depths: 0, 780, and 1560 cm. Each state of bit wear was evaluated by three trials (nine trials total). For each trial, an automated laboratory test bench system drilled 41 holes 1.3 cm diameter, and 10 cm deep into concrete block at a rate of one hole per minute using a commercially available hammer drill and masonry bits. During each trial, dust was continuously captured by two respirable and one inhalable sampling trains and noise was sampled with a noise dosimeter. The room was thoroughly cleaned between trials. RESULTS: When comparing results for the sharp (0 cm) versus dull bit (1560 cm), the mean respirable silica increased from 0.41 to 0.74 mg m-3 in sampler 1 (P = 0.012) and from 0.41 to 0.89 mg m-3 in sampler 2 (P = 0.024); levels above the NIOSH recommended exposure limit of 0.05 mg m-3. Likewise, mean noise levels increased from 112.8 to 114.4 dBA (P < 0.00001). Drilling productivity declined with increasing wear from 10.16 to 7.76 mm s-1 (P < 0.00001). DISCUSSION: Increasing bit wear was associated with increasing respirable silica dust and noise and reduced drilling productivity. The levels of dust and noise produced by these experimental conditions would require dust capture, hearing protection, and possibly respiratory protection. The findings support the adoption of a bit replacement program by construction contractors.


Assuntos
Poluentes Ocupacionais do Ar/análise , Indústria da Construção/instrumentação , Poeira/análise , Exposição por Inalação/análise , Ruído Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Dióxido de Silício/análise , Desempenho Profissional/normas , Eficiência , Humanos , Projetos Piloto
7.
J Occup Environ Hyg ; 14(7): 510-522, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28406371

RESUMO

Nano-enabled construction products have entered into commerce. There are concerns about the safety of manufactured nanomaterials, and exposure assessments are needed for a more complete understanding of risk. This study assessed potential inhalation exposure to ZnO nanoparticles during spray application and power sanding of a commercially available wood sealant and evaluated the effectiveness of local exhaust ventilation in reducing exposure. A tradesperson performed the spraying and sanding inside an environmentally-controlled chamber. Dust control methods during sanding were compared. Filter-based sampling, electron microscopy, and real-time particle counters provided measures of exposure. Airborne nanoparticles above background levels were detected by particle counters for all exposure scenarios. Nanoparticle number concentrations and particle size distributions were similar for sanding of treated versus untreated wood. Very few unbound nanoparticles were detected in aerosol samples via electron microscopy, rather nano-sized ZnO was contained within, or on the surface of larger airborne particles. Whether the presence of nanoscale ZnO in these aerosols affects toxicity merits further investigation. Mass-based exposure measurements were below the NIOSH Recommended Exposure Limit for Zn, although there are no established exposure limits for nanoscale ZnO. Local exhaust ventilation was effective, reducing airborne nanoparticle number concentrations by up to 92% and reducing personal exposure to total dust by at least 80% in terms of mass. Given the discrepancies between the particle count data and electron microscopy observations, the chemical identity of the airborne nanoparticles detected by the particle counters remains uncertain. Prior studies attributed the main source of nanoparticle emissions during sanding to copper nanoparticles generated from electric sander motors. Potentially contrary results are presented suggesting the sander motor may not have been the primary source of nanoparticle emissions in this study. Further research is needed to understand potential risks faced by construction workers exposed to mixed aerosols containing manufactured nanomaterials. Until these risks are better understood, this study demonstrates that engineering controls can reduce exposure to manufactured nanomaterials; doing so may be prudent for protecting worker health.


Assuntos
Poluentes Ocupacionais do Ar/análise , Nanopartículas/análise , Exposição Ocupacional/análise , Óxido de Zinco/análise , Poluentes Ocupacionais do Ar/química , Materiais de Construção , Monitoramento Ambiental/métodos , Humanos , Exposição por Inalação/análise , Microscopia Eletrônica de Varredura , Nanopartículas/química , Nanopartículas/ultraestrutura , Tamanho da Partícula , Ventilação/métodos , Madeira
8.
J Med Chem ; 59(4): 1330-9, 2016 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-26815195

RESUMO

In recent years, inhibition of the interaction between the bromodomain and extra-terminal domain (BET) family of chromatin adaptors and acetyl-lysine residues on chromatin has emerged as a promising approach to regulate the expression of important disease-relevant genes, including MYC, BCL-2, and NF-κB. Here we describe the identification and characterization of a potent and selective benzoisoxazoloazepine BET bromodomain inhibitor that attenuates BET-dependent gene expression in vivo, demonstrates antitumor efficacy in an MV-4-11 mouse xenograft model, and is currently undergoing human clinical trials for hematological malignancies (CPI-0610).


Assuntos
Antineoplásicos/química , Antineoplásicos/uso terapêutico , Azepinas/química , Azepinas/uso terapêutico , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Leucemia Mieloide Aguda/tratamento farmacológico , Proteínas Nucleares/antagonistas & inibidores , Fatores de Transcrição/antagonistas & inibidores , Animais , Antineoplásicos/farmacocinética , Antineoplásicos/farmacologia , Azepinas/farmacocinética , Azepinas/farmacologia , Proteínas de Ciclo Celular , Linhagem Celular Tumoral , Ensaios Clínicos como Assunto , Cães , Genes myc/efeitos dos fármacos , Humanos , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/metabolismo , Camundongos , Proteínas Nucleares/química , Proteínas Nucleares/metabolismo , Proteínas Proto-Oncogênicas c-myc/genética , Ratos , Fatores de Transcrição/química , Fatores de Transcrição/metabolismo , Ensaios Antitumorais Modelo de Xenoenxerto
10.
Public Health Rep ; 124 Suppl 1: 101-11, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19618812

RESUMO

OBJECTIVES: A number of tasks in construction generate worker overexposures to respirable crystalline silica dust, which is a significant contributor to occupational mortality and morbidity. This study evaluated the performance of commercially available engineering controls used in dusty construction tasks commonly performed by bricklayers. METHODS: Local exhaust ventilation (LEV) controls for a portable abrasive cutter and for tuckpointing grinders were examined at a bricklayers' training center, as were two stationary wet saws. Personal breathing zone air samples were collected with and without the use of LEV or water suppression during simulated concrete block cutting, brick cutting, and tuckpointing. RESULTS: Compared with the use of no exposure control during block and brick cutting, the portable LEV unit significantly reduced mean respirable quartz exposures by 96% for block cutting and 91% for brick cutting (p < 0.01). The use of stationary wet saws was also associated with 91% reductions in exposure (p < 0.01). For tuckpointing, the reductions in mean respirable quartz concentrations were between 91% and 93% with the LEV controls (p < 0.05). CONCLUSIONS: Reductions of up to 96% in mean respirable quartz concentration were observed between control and no-control scenarios. These reductions with commercially available off-the-shelf tools demonstrate the effectiveness of engineering control interventions to reduce crystalline silica exposures in construction. Strategies to further improve control performance and approaches for increasing control interventions in construction are needed.


Assuntos
Poluentes Ocupacionais do Ar/intoxicação , Poluição do Ar/prevenção & controle , Materiais de Construção/intoxicação , Segurança de Equipamentos/métodos , Exposição por Inalação/prevenção & controle , Exposição Ocupacional/prevenção & controle , Dióxido de Silício/intoxicação , Silicose/prevenção & controle , Poeira/prevenção & controle , Engenharia/métodos , Desenho de Equipamento , Humanos , Exposição por Inalação/efeitos adversos , Exposição Ocupacional/efeitos adversos , Equipamentos de Proteção , Silicose/etiologia , Ventilação/métodos
12.
Blood ; 108(12): 3674-81, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-16902153

RESUMO

Tandutinib (MLN518/CT53518) is a novel quinazoline-based inhibitor of the type III receptor tyrosine kinases: FMS-like tyrosine kinase 3 (FLT3), platelet-derived growth factor receptor (PDGFR), and KIT. Because of the correlation between FLT3 internal tandem duplication (ITD) mutations and poor prognosis in acute myelogenous leukemia (AML), we conducted a phase 1 trial of tandutinib in 40 patients with either AML or high-risk myelodysplastic syndrome (MDS). Tandutinib was given orally in doses ranging from 50 mg to 700 mg twice daily The principal dose-limiting toxicity (DLT) of tandutinib was reversible generalized muscular weakness, fatigue, or both, occurring at doses of 525 mg and 700 mg twice daily. Tandutinib's pharmacokinetics were characterized by slow elimination, with achievement of steady-state plasma concentrations requiring greater than 1 week of dosing. Western blotting showed that tandutinib inhibited phosphorylation of FLT3 in circulating leukemic blasts. Eight patients had FLT3-ITD mutations; 5 of these were evaluable for assessment of tandutinib's antileukemic effect. Two of the 5 patients, treated at 525 mg and 700 mg twice daily, showed evidence of antileukemic activity, with decreases in both peripheral and bone marrow blasts. Tandutinib at the MTD (525 mg twice daily) should be evaluated more extensively in patients with AML with FLT3-ITD mutations to better define its antileukemic activity.


Assuntos
Leucemia Mieloide Aguda/tratamento farmacológico , Síndromes Mielodisplásicas/tratamento farmacológico , Piperazinas/efeitos adversos , Piperazinas/farmacocinética , Inibidores de Proteínas Quinases/efeitos adversos , Inibidores de Proteínas Quinases/farmacocinética , Quinazolinas/efeitos adversos , Quinazolinas/farmacocinética , Tirosina Quinase 3 Semelhante a fms/antagonistas & inibidores , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/metabolismo , Medula Óssea/patologia , Relação Dose-Resposta a Droga , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Feminino , Humanos , Leucemia Mieloide Aguda/sangue , Leucemia Mieloide Aguda/complicações , Leucemia Mieloide Aguda/genética , Leucemia Mieloide Aguda/patologia , Masculino , Pessoa de Meia-Idade , Mutação , Síndromes Mielodisplásicas/sangue , Síndromes Mielodisplásicas/complicações , Síndromes Mielodisplásicas/genética , Síndromes Mielodisplásicas/patologia , Fosforilação/efeitos dos fármacos , Piperazinas/administração & dosagem , Inibidores de Proteínas Quinases/administração & dosagem , Processamento de Proteína Pós-Traducional/efeitos dos fármacos , Proteínas Proto-Oncogênicas c-kit/metabolismo , Quinazolinas/administração & dosagem , Receptores do Fator de Crescimento Derivado de Plaquetas/antagonistas & inibidores , Receptores do Fator de Crescimento Derivado de Plaquetas/metabolismo , Tirosina Quinase 3 Semelhante a fms/genética , Tirosina Quinase 3 Semelhante a fms/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...