1.
Cardiovasc Revasc Med ; 57: 18-24, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37400346

RESUMO

PURPOSE: To determine the frequency of medial arterial calcification (MAC) fracture following Auryon laser atherectomy using micro-CT and histologic evaluation in an atherosclerotic human cadaveric limb model. METHODS: Two below-the-knee calcified arterial segments from human cadaver limbs underwent treatment with the Auryon laser system with or without plain old balloon angioplasty (POBA). Micro-CT and angiography were performed before and after treatment followed by histological evaluation of regions showing calcium disruption. RESULTS: All treatment zones were successfully treated with the Auryon laser (n = 9). Six of 9 treatment zones showed calcium fracture on micro-CT. Each treatment zone was further subdivided using micro-CT analysis (36 evaluated sections) of which 18 sections revealed calcium fracture. Sections with calcium fracture had significantly more confluent and uninterrupted circumferential calcification than sections without calcium fracture (arc of calcification 360.0 [323.7-360.0] vs 312.8 [247.4-314.2] degree, p = 0.007), whereas there were no differences in size of calcium burden (3.4 [2.8-3.9] vs 2.8 [1.3-4.6] mm2, p = 0.46). No arterial dissection or rupture was seen. CONCLUSIONS: Auryon laser atherectomy produced fractures of medial arterial calcification in this cadaveric human atherosclerotic peripheral artery model. This effect was observed in arterial segments with a pattern of circumferential uninterrupted calcification (i.e. larger arc of calcification) regardless of calcium burden. Our pilot data suggests Auryon laser may be a promising therapy for calcified lesions.


Assuntos
Angioplastia com Balão , Aterosclerose , Doença Arterial Periférica , Calcificação Vascular , Humanos , Cálcio , Microtomografia por Raio-X , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Aterectomia/efeitos adversos , Angioplastia com Balão/efeitos adversos , Cadáver , Resultado do Tratamento , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia
2.
J Invasive Cardiol ; 34(7): E496-E498, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35714224

RESUMO

BACKGROUND: The Auryon 355-nm laser atherectomy system (AngioDynamics, Inc) showed a low rate of target-lesion revascularization (TLR) at 6-month follow-up in the EX-PAD-03 investigational device exemption study and the Auryon single-center experience (SCE) in treating infrainguinal arteries. In this study, we present the 1-year outcomes of the Auryon SCE study on TLR in all comers at a single center. METHODS: The Auryon SCE was a retrospective study that evaluated the outcomes of all comers treated with the Auryon laser for infrainguinal arterial disease. There was no TLR seen at 6-month follow-up. We present the TLR rate at 1 year in the same cohort of patients. TLR rates were obtained from medical record review of patients enrolled in the study who had completed office visit follow-up at 1 year. Secondary endpoints included unplanned major amputation and total mortality. Kaplan-Meier survival analysis was performed to estimate the freedom from TLR rate following index procedure. Statistical differences were analyzed for ankle-brachial index (ABI) between baseline and 1 year. RESULTS: A total of 56 patients (65 procedures, 70 lesions) were enrolled. The mean age was 70.9 ± 10 years, with 66.1% males, 48.2% diabetics, and 25% demonstrating limb ischemia. Of the 70 lesions, 31.4% had severe calcification, 38.6% were chronic total occlusions, and 48.6% were de novo disease (in-stent restenosis, 29.6%). Stenting was performed in 24/70 lesions (34.3%), with 11/70 (15.7%) bailout procedures. Embolic filters were used in 26/65 procedures (40%). The majority of treated lesions were femoropopliteal (90.0%); of all procedures, 29.2% had 2 or more prior interventions. Drug-coated balloon usage was 47.1% Lutonix (BD/Bard), 27.1% In.Pact (Boston Scientific), and 1.4% both in all lesions treated. Distal embolization occurred in 1/65 procedures (1.5%). At 1 year, mortality occurred in 3/56 patients (5.4%). Of 65 limbs treated, 2 (3.1%) had major amputation at 1 year. The probability of freedom from TLR was 83.7%. CONCLUSION: In a realworld cohort of patient with complex disease, the Auryon laser had excellent freedom from TLR at 1 year.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Feminino , Artéria Femoral/cirurgia , Humanos , Lasers , Salvamento de Membro , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular