3.
J Biomech Eng ; 132(12): 121007, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21142321

RESUMO

Migration of stent-grafts (SGs) after endovascular aneurysm repair of abdominal aortic aneurysms is a serious complication that may require secondary intervention. Experimental, analytical, and computational studies have been carried out in the past to understand the factors responsible for migration. In an experimental setting, it can be very challenging to correctly capture and understand the interaction between a SG and an artery. Quantities such as coefficient of friction (COF) and contact pressures that characterize this interaction are difficult to measure using an experimental approach. This behavior can be investigated with good accuracy using finite element modeling. Although finite element models are able to incorporate frictional behavior of SGs, the absence of reliable values of coefficient of friction make these simulations unreliable. The aim of this paper is to demonstrate a method for determining the coefficients of friction of a self-expanding endovascular stent-graft. The methodology is demonstrated by considering three commercially available self-expanding SGs, labeled as A, B, and C. The SGs were compressed, expanded, and pulled out of polymeric cylinders of varying diameters and the pullout force was recorded in each case. The SG geometries were recreated using computer-aided design modeling and the entire experiment was simulated in ABAQUS 6.8/STANDARD. An optimization procedure was carried out for each SG oversize configuration to determine the COF that generated a frictional force corresponding to that measured in the experiment. The experimental pullout force and analytically determined COF for SGs A, B, and C were in the range of 6-9 N, 3-12 N, and 3-9 N and 0.08-0.16, 0.22-0.46, and 0.012-0.018, respectively. The computational model predicted COFs in the range of 0.00025-0.0055, 0.025-0.07, and 0.00025-0.006 for SGs A, B, and C, respectively. Our results suggest that for SGs A and B, which are exoskeleton based devices, the pullout forces increase upto a particular oversize beyond which they plateau, while pullout forces showed a continuous increase with oversize for SG C, which is an endoskeleton based device. The COF decreased with oversizing for both types of SGs. The proposed methodology will be useful for determining the COF between self-expanding stent-grafts from pullout tests on human arterial tissue.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Stents , Aneurisma da Aorta Abdominal/fisiopatologia , Materiais Biocompatíveis , Fenômenos Biomecânicos , Engenharia Biomédica , Implante de Prótese Vascular , Força Compressiva , Simulação por Computador , Análise de Elementos Finitos , Fricção , Humanos , Teste de Materiais , Modelos Cardiovasculares , Pressão , Desenho de Prótese
4.
J Endovasc Ther ; 17(1): 95-107, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20199275

RESUMO

PURPOSE: To develop an improved methodology for investigating the parameters influencing stent-graft migration, with particular focus on the limitations of existing methods. METHODS: A physiological silicone rubber abdominal aortic aneurysm (AAA) model for fixation studies was manufactured based on an idealized AAA geometry: the model had a 24-mm neck, a 50-mm aneurysm, 12-mm-diameter legs, a 60 degrees bifurcation angle, and 2-mm-thick walls. The models were authenticated in neck fixation experiments. The displacement force required to migrate stent-grafts in physiological pulsatile flow was tested dynamically in water at 37 degrees C. A commercially available longitudinally rigid stent-graft (AneuRx) and a homemade device with little longitudinal rigidity were studied in a number of different configurations to investigate the effect of neck fixation length and systolic pressure on displacement force. RESULTS: The AneuRx (6.95+/-0.49 to 8.52+/-0.5 N) performed significantly better than the homemade device (2.57+/-0.11 to 4.62+/-0.25 N) in pulsatile flow. The opposite was true in the neck fixation tests because the longitudinal stiffness of the AneuRx was not accounted for. Increasing pressure or decreasing fixation length compromised the fixation of the homemade device. This relationship was not as clear for the AneuRx because decreasing proximal fixation resulted in an increase in iliac fixation, which could assist fixation in this device. CONCLUSION: Assessing the migration resistance of stent-grafts based solely on proximal fixation discriminates against devices that are longitudinally stiff. Current in vivo models may give inaccurate displacement forces due to the high degree of oversizing in these studies. A novel in vitro approach, accounting for longitudinal rigidity and realistic graft oversizing, was developed to determine the resistance of aortic stent-grafts to migration in the period immediately after device implantation.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Migração de Corpo Estranho/prevenção & controle , Stents , Aorta Abdominal/patologia , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Análise de Falha de Equipamento , Migração de Corpo Estranho/etiologia , Humanos , Teste de Materiais , Modelos Anatômicos , Falha de Prótese , Fluxo Pulsátil , Estresse Mecânico
5.
J Endovasc Ther ; 16(3): 322-35, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19642790

RESUMO

PURPOSE: To identify the rupture locations of idealized physical models of abdominal aortic aneurysm (AAA) using an in-vitro setup and to compare the findings to those predicted numerically. METHODS: Five idealized AAAs were manufactured using Sylgard 184 silicone rubber, which had been mechanically characterized from tensile tests, tear tests, and finite element analysis. The models were then inflated to the point of rupture and recorded using a high-speed camera. Numerical modeling attempted to confirm these rupture locations. Regional variations in wall thickness of the silicone models was also quantified and applied to numerical models. RESULTS: Four of the 5 models tested ruptured at inflection points in the proximal and distal regions of the aneurysm sac and not at regions of maximum diameter. These findings agree with high stress regions computed numerically. Wall stress appears to be independent of wall thickness, with high stress occurring at regions of inflection regardless of wall thickness variations. CONCLUSION: According to these experimental and numerical findings, AAAs experience higher stresses at regions of inflection compared to regions of maximum diameter. Ruptures of the idealized silicone models occurred predominantly at the inflection points, as numerically predicted. Regions of inflection can be easily identified from basic 3-dimensional reconstruction; as ruptures appear to occur at inflection points, these findings may provide a useful insight into the clinical significance of inflection regions. This approach will be applied to patient-specific models in a future study.


Assuntos
Aneurisma Roto/etiologia , Aneurisma Roto/patologia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/patologia , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Análise de Elementos Finitos , Humanos , Reprodutibilidade dos Testes , Silicones , Estresse Mecânico , Resistência à Tração
6.
Med Eng Phys ; 31(8): 1002-12, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19595622

RESUMO

A range of silicone rubbers were created based on existing commercially available materials. These silicones were designed to be visually different from one another and have distinct material properties, in particular, ultimate tensile strengths and tear strengths. In total, eleven silicone rubbers were manufactured, with the materials designed to have a range of increasing tensile strengths from approximately 2 to 4 MPa, and increasing tear strengths from approximately 0.45 to 0.7 N/mm. The variations in silicones were detected using a standard colour analysis technique. Calibration curves were then created relating colour intensity to individual material properties. All eleven materials were characterised and a 1st order Ogden strain energy function applied. Material coefficients were determined and examined for effectiveness. Six idealised abdominal aortic aneurysm models were also created using the two base materials of the study, with a further model created using a new mixing technique to create a rubber model with randomly assigned material properties. These models were then examined using videoextensometry and compared to numerical results. Colour analysis revealed a statistically significant linear relationship (p<0.0009) with both tensile strength and tear strength, allowing material strength to be determined using a non-destructive experimental technique. The effectiveness of this technique was assessed by comparing predicted material properties to experimentally measured methods, with good agreement in the results. Videoextensometry and numerical modelling revealed minor percentage differences, with all results achieving significance (p<0.0009). This study has successfully designed and developed a range of silicone rubbers that have unique colour intensities and material strengths. Strengths can be readily determined using a non-destructive analysis technique with proven effectiveness. These silicones may further aid towards an improved understanding of the biomechanical behaviour of aneurysms using experimental techniques.


Assuntos
Aneurisma Aórtico , Modelos Anatômicos , Elastômeros de Silicone , Biomimética , Calibragem , Cor , Resistência à Tração
7.
J Endovasc Ther ; 15(4): 468-84, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18729555

RESUMO

Endovascular repair of abdominal aortic aneurysms has generated widespread interest since the procedure was first introduced two decades ago. It is frequently performed in patients who suffer from substantial comorbidities that may render them unsuitable for traditional open surgical repair. Although this minimally invasive technique substantially reduces operative risk, recovery time, and anesthesia usage in these patients, the endovascular method has been prone to a number of failure mechanisms not encountered with the open surgical method. Based on long-term results of second- and third-generation devices that are currently becoming available, this study sought to identify the most serious failure mechanisms, which may have a starting point in the morphological changes in the aneurysm and stent-graft. To investigate the "behavior" of the aneurysm after stent-graft repair, i.e., how its length, angulation, and diameter change, we utilized state-of-the-art ex vivo methods, which researchers worldwide are now using to recreate these failure modes.