Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Food Chem Toxicol ; 76: 116-24, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25530104

RESUMO

Aflatoxin B1 (AFB1) and Ochratoxin A (OTA) are genotoxic mycotoxins that can contaminate a variety of foodstuffs, the liver and the kidney being their target organs, respectively. The micronucleus (MN) assay (bone marrow) and the comet assay (liver and kidney) were performed simultaneously in F344 rats, treated with AFB1 (0.25 mg/kg b.w.), OTA (0.5 mg/kg b.w.) or both mycotoxins. After AFB1 treatment, histopathology and biochemistry analysis showed liver necrosis, focal inflammation and an increase in Alanine Aminotransferase and Aspartate Aminotransferase. OTA alone did not cause any alteration. The acute hepatotoxic effects caused by AFB1 were less pronounced in animals treated with both mycotoxins. With regard to the MN assay, after 24 h, positive results were obtained for AFB1 and negative results were obtained for OTA, although both toxins caused bone marrow toxicity. In the combined treatment, OTA reduced the toxicity and the number of MN produced by AFB1. In the comet assay, after 3 h, positive results were obtained for AFB1 in the liver and for OTA in the kidney. The combined treatment reduced DNA damage in the liver and had no influence in the kidney. Altogether, these results may be indicative of an antagonistic relationship regarding the genotoxicity of both mycotoxins.


Assuntos
Aflatoxina B1/toxicidade , Dano ao DNA/efeitos dos fármacos , Ocratoxinas/toxicidade , Aflatoxina B1/sangue , Animais , Ensaio Cometa , Relação Dose-Resposta a Droga , Hepatócitos/efeitos dos fármacos , Rim/efeitos dos fármacos , Rim/metabolismo , Fígado/citologia , Fígado/efeitos dos fármacos , Masculino , Testes para Micronúcleos , Ocratoxinas/sangue , Ratos , Ratos Endogâmicos F344
2.
Mutagenesis ; 28(3): 279-86, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23446176

RESUMO

The alkaline comet assay is an established, sensitive method extensively used in biomonitoring studies. This method can be modified to measure a range of different types of DNA damage. However, considerable differences in the protocols used by different research groups affect the inter-laboratory comparisons of results. The aim of this study was to assess the inter-laboratory, intra-laboratory, sample and residual (unexplained) variations in DNA strand breaks and formamidopyrimidine DNA glycosylase (FPG)-sensitive sites measured by the comet assay by using a balanced Latin square design. Fourteen participating laboratories used their own comet assay protocols to measure the level of DNA strand breaks and FPG-sensitive sites in coded samples containing peripheral blood mononuclear cells (PBMC) and the level of DNA strand breaks in coded calibration curve samples (cells exposed to different doses of ionising radiation) on three different days of analysis. Eleven laboratories found dose-response relationships in the coded calibration curve samples on two or three days of analysis, whereas three laboratories had technical problems in their assay. In the coded calibration curve samples, the dose of ionising radiation, inter-laboratory variation, intra-laboratory variation and residual variation contributed to 60.9, 19.4, 0.1 and 19.5%, respectively, of the total variation. In the coded PBMC samples, the inter-laboratory variation explained the largest fraction of the overall variation of DNA strand breaks (79.2%) and the residual variation (19.9%) was much larger than the intra-laboratory (0.3%) and inter-subject (0.5%) variation. The same partitioning of the overall variation of FPG-sensitive sites in the PBMC samples indicated that the inter-laboratory variation was the strongest contributor (56.7%), whereas the residual (42.9%), intra-laboratory (0.2%) and inter-subject (0.3%) variations again contributed less to the overall variation. The results suggest that the variation in DNA damage, measured by comet assay, in PBMC from healthy subjects is assay variation rather than variation between subjects.


Assuntos
Ensaio Cometa , Quebras de DNA , DNA-Formamidopirimidina Glicosilase/metabolismo , Leucócitos Mononucleares/metabolismo , Adulto , Ensaio Cometa/métodos , Quebras de DNA/efeitos da radiação , Relação Dose-Resposta à Radiação , Feminino , Raios gama/efeitos adversos , Humanos , Leucócitos Mononucleares/efeitos da radiação , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
3.
Mutagenesis ; 27(6): 665-72, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22844078

RESUMO

There are substantial inter-laboratory variations in the levels of DNA damage measured by the comet assay. The aim of this study was to investigate whether adherence to a standard comet assay protocol would reduce inter-laboratory variation in reported values of DNA damage. Fourteen laboratories determined the baseline level of DNA strand breaks (SBs)/alkaline labile sites and formamidopyrimidine DNA glycosylase (FPG)-sensitive sites in coded samples of mononuclear blood cells (MNBCs) from healthy volunteers. There were technical problems in seven laboratories in adopting the standard protocol, which were not related to the level of experience. Therefore, the inter-laboratory variation in DNA damage was only analysed using the results from laboratories that had obtained complete data with the standard comet assay protocol. This analysis showed that the differences between reported levels of DNA SBs/alkaline labile sites in MNBCs were not reduced by applying the standard assay protocol as compared with the laboratory's own protocol. There was large inter-laboratory variation in FPG-sensitive sites by the laboratory-specific protocol and the variation was reduced when the samples were analysed by the standard protocol. The SBs and FPG-sensitive sites were measured in the same experiment, indicating that the large spread in the latter lesions was the main reason for the reduced inter-laboratory variation. However, it remains worrying that half of the participating laboratories obtained poor results using the standard procedure. This study indicates that future comet assay validation trials should take steps to evaluate the implementation of standard procedures in participating laboratories.


Assuntos
Ensaio Cometa/métodos , Ensaio Cometa/normas , Dano ao DNA , Laboratórios/normas , Calibragem , DNA-Formamidopirimidina Glicosilase/análise , Determinação de Ponto Final , Humanos , Leucócitos Mononucleares/química , Leucócitos Mononucleares/citologia , Modelos Lineares
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(26): 2733-40, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21868292

RESUMO

A rapid and simple method for the simultaneous quantification of AFB1 and OTA in rat plasma, liver and kidney by UHPLC-FLD has been successfully validated according to the following criteria: selectivity, stability, linearity, precision, accuracy, recovery, robustness and limits of quantification and detection. The extraction method, calibration curves and chromatographic conditions are common for the three matrices. Plasma and homogenized tissue samples (100 µL) were extracted with acetonitrile:formic acid mixture (99:1) (300 µL). Chromatographic separation was performed with a mixture of water and acetonitrile:methanol (50:50), both acidified with 0.5% of formic acid using a gradient profile. The method avoids the use of immunoaffinity columns and allows reduction of sample and solvent volumes as well as toxic wastes. The detection is based on a photochemical reaction which enhances the AFB1 response without affecting the OTA signal before reaching the fluorescent detector. The mycotoxin recovery for each matrix was very efficient, between 93% and 96% for AFB1 and between 94% and 96% for OTA. For both mycotoxins the LOQs were 2µg/L in plasma and 8µg/kg in liver and kidney. The method has successfully been applied to rat samples after a single oral administration of a mixture of AFB1 and OTA and it could be a useful tool in toxicokinetic and toxicological studies.


Assuntos
Aflatoxina B1/análise , Cromatografia Líquida de Alta Pressão/métodos , Ocratoxinas/análise , Testes de Toxicidade Aguda/métodos , Acetonitrilas/química , Aflatoxina B1/administração & dosagem , Aflatoxina B1/sangue , Animais , Feminino , Imunoensaio , Rim/química , Fígado/química , Masculino , Ocratoxinas/administração & dosagem , Ocratoxinas/sangue , Ratos , Ratos Endogâmicos F344 , Reprodutibilidade dos Testes , Distribuição Tecidual
5.
Food Chem Toxicol ; 49(9): 1935-42, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21571028

RESUMO

The impact of age and gender on Ochratoxin A (OTA) distribution in kidney and liver were studied. OTA was quantified in kidney and liver of young and mature rats of both sexes. Data was fit simultaneously using the population approach with NONMEM program. Fed and fasted mature males showed a 30% decrease and an 11% increase in relative bioavailability, respectively, in comparison with the rest of the groups. The OTA concentrations reached in kidney and liver were very similar between both organs. The models that best fit to data were the ones that considered that distribution of OTA to kidney and liver occurs from the central compartment and that elimination occurs mainly from the liver compartment. The kinetic analysis revealed that both, the apparent volume of distribution of the central compartment (V/F) and the apparent volume of distribution of the liver and kidney compartments (V(L,K)/F) increased significantly with body weight. Thus, the sex differences observed in organs distribution are a reflection of the differences in relative bioavailability observed in adult males, as a consequence of the fed and fasted conditions and to the significant higher body weight of mature males which directly affected the V/F and V(L,K)/F.


Assuntos
Rim/metabolismo , Fígado/metabolismo , Ocratoxinas/farmacocinética , Animais , Feminino , Masculino , Ratos , Ratos Endogâmicos F344 , Distribuição Tecidual
6.
J Chromatogr A ; 1215(1-2): 100-6, 2008 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-19027908

RESUMO

A fast and simple HPLC-FLD (high-performance liquid chromatography-fluorescence detection) analytical method has been developed and validated for the determination of ochratoxin A in rat plasma, kidney and liver. The extraction method, calibration curves and chromatographic conditions are common for the three matrices. Plasma and homogenized tissue samples (250 microL) were extracted with ethanol (400 microL) and trichloroacetic acid 20% (w/v) (50 microL). Supernatants were directly injected into the HPLC system, analyzed on a 5-microm (25 cm x 0.4 cm) Tracer Extrasil ODS2 column using FLD (excitation wavelength=225 nm, emission wavelength=461 nm). The mobile phase was 29:29:42 (v/v) methanol-acetonitrile-sodium acetate. The small volume of sample needed which allows the obtaining of ochratoxin A levels in individual tissue samples from small animals and the wide range of concentrations that could be analyzed make this method easy to apply in toxicology and toxicokinetic studies of this mycotoxin, even in low dose carcinogenic studies. This method was linear and selective for all the matrices. Precision and accuracy were always <10% and recovery was very efficient in each case. Limits of detection and quantification were also calculated in plasma (1 and 8.4 microg/L), kidney (14.3 and 55.8 microg/kg) and liver (4.1 and 52.8 microg/kg). Stability of the tissue homogenates was assured for at least 10 months at -80 degrees C. The method has been successfully applied to the analysis of rat samples after 7 days of ochratoxin A (0.5mg/kg b.w. dissolved in an aqueous NaHCO(3) solution) administration by oral gavage.


Assuntos
Análise Química do Sangue , Cromatografia Líquida de Alta Pressão/métodos , Rim/química , Fígado/química , Testes de Toxicidade , Animais , Masculino , Ratos , Ratos Endogâmicos F344 , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...