Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Equine Vet J ; 50(6): 865-869, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29518268

RESUMO

BACKGROUND: In dogs, due to better alignment with the aortic outflow, the subcostal (SC) transducer site provides greater Doppler-derived velocities than those obtained from the left parasternal view. The feasibility of this imaging approach has never been described in equine echocardiography. OBJECTIVES: The objective of this study was to evaluate the feasibility of the SC view in newborn foals and compare aortic two-dimensional and Doppler-derived velocity measurements with those of standard parasternal long-axis (LAX) views. STUDY DESIGN: A prospective observational study. METHODS: Twenty-three newborn healthy Standardbred and Warmblood foals, aged from 7 h to 6 days, underwent transthoracic two-dimensional (2DE), M-mode and Doppler echocardiography that was performed in lateral recumbency. Right and left parasternal long-axis (R-LAX, L-LAX) and SC views were obtained to perform 2DE and Doppler assessments of the aortic valve (AoV). Aortic diameter at the sinus of Valsalva (AoS D) was measured from R-LAX and SC images. Aortic maximal velocity (AoV Velmax ), velocity time integral (AoV VTI) and pressure gradient (AoV PG) were obtained by pulsed wave Doppler spectra from SC and L-LAX views. RESULTS: The SC view was feasible in all foals. No significant difference was found in AoS D between different views (P = 0.06), and no significant correlation was detected for bodyweight (BW). AoV Velmax , VTI and PG obtained from the SC view were greater than from the L-LAX view (P<0.0001, P = 0.0001 and P<0.0001 respectively), especially in foals with lower BW. MAIN LIMITATIONS: The order of the transducer site was not randomised among foals, and the observer was not blinded during offline measurement. CONCLUSIONS: The SC view can be easily obtained in recumbent newborn foals and provides optimal alignment with aortic outflow, leading to more reliable Doppler flow velocity than the conventional L-LAX view. Further investigations of the potential use of this view in Doppler estimation of aortic outflow and cardiac assessment of sick foals are recommended.


Assuntos
Animais Recém-Nascidos/anatomia & histologia , Aorta/diagnóstico por imagem , Aorta/fisiologia , Ecocardiografia Doppler/veterinária , Cavalos/anatomia & histologia , Animais , Animais Recém-Nascidos/fisiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiologia , Velocidade do Fluxo Sanguíneo/veterinária , Ecocardiografia Doppler/métodos , Estudos de Viabilidade , Feminino , Cavalos/fisiologia , Masculino , Estudos Prospectivos
2.
BMC Vet Res ; 13(1): 141, 2017 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-28545570

RESUMO

BACKGROUND: This study describes the feasibility of Contrast Enhanced Ultrasonography (CEUS) in the diagnostic work-up of non-cardiac thoracic disorders of small animals. The second aim is to assess the usefulness of CEUS as a direct guide for sample procedures. RESULTS: Forty animals, 28 dogs and 12 cats, were included in the study. Thoracic disorders included 23 pulmonary lesions [primary carcinoma (14), lymphoma (1), sarcoma (1), histiocytic sarcoma (1), abscess (1) and pneumonia (5)] and 17 mediastinal lesions [lymphoma (8), thymoma (3), mesothelioma (1), melanoma (1), carcinomatous lymphadenopathy (1), mixsosarcoma (1), lipoma (1), and abscess (1)]. The majority of neoplastic pulmonary lesions showed an inhomogeneous distribution of contrast medium, whereas inflammatory lesions had a homogenous distribution with typical pulmonary vessels ramification. The majority of mediastinal malignant lesions showed an inhomogeneous distribution pattern. The lung and mediastinal abscesses had peripheral enhancement of the wall with an avascular center. All cytological and biopsy samples obtained after CEUS were diagnostic. Quantitative analysis, performed in 19/23 pulmonary lesions, showed a statistically significant difference (P < 0.0001) between the arrival time of the malignant (7.27 s - range 4.46-13.52 s) and benign (4.52 s - range 2.87-6.06 s) pulmonary lesions. CONCLUSIONS: CEUS may be a useful tool for the evaluation of non-cardiac thoracic lesions. The contrast medium allows for the precise definition of lesion edges, the presence of necrotic areas, and the distribution of pulmonary vessels. Based on our preliminary results, the use of ultrasonographic contrast medium can be recommended for improving the diagnostic usefulness of cytology and biopsy sampling, because CEUS may help to define necrotic areas from viable tissue.


Assuntos
Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Pneumopatias/veterinária , Doenças do Mediastino/veterinária , Ultrassonografia/veterinária , Animais , Gatos , Meios de Contraste , Cães , Estudos de Viabilidade , Feminino , Pneumopatias/diagnóstico por imagem , Masculino , Doenças do Mediastino/diagnóstico por imagem , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...