Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Mycol Med ; 34(3): 101490, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38852225

RESUMO

Due to large outbreaks observed worldwide, Candida auris has emerged as a major threat to healthcare facilities. To prevent these phenomena, a systematic screening should be performed in patients transferred from regions where the pathogen is highly endemic. In this study, we recorded and analyzed French mycologists' current knowledge and practice regarding C. auris screening and diagnosis. Thirty-six centers answered an online questionnaire. Only 11 (30.6 %) participants were aware of any systematic screening for C. auris for patients admitted to their hospital. In the case of post-admission screening, axillae/groins (n = 21), nares (n = 7), rectum (n = 9), and mouth (n = 6) alone or various combinations were the body sites the most frequently sampled. Only six centers (8.3 %) reported using a commercially available plate allowing the differentiation of C. auris colonies from that of other Candida species, while five laboratories (13.8 %) had implemented a C. auris-specific qPCR. Considering the potential impact on infected patients and the risk of disorganization in the care of patients, it is crucial to remember to biologists and clinicians the utmost importance of systematic screening on admission.

2.
Eur Phys J C Part Fields ; 77(11): 785, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31997932

RESUMO

This paper reports on the development of a technology involving 100 Mo -enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ( ∼ 1 kg ), high optical quality, radiopure 100 Mo -containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2-0.4 kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the Q-value of the double-beta transition of 100 Mo (3034 keV) is 4-6 keV FWHM. The rejection of the α -induced dominant background above 2.6 MeV is better than 8 σ . Less than 10 µ Bq/kg activity of 232 Th ( 228 Th ) and 226 Ra in the crystals is ensured by boule recrystallization. The potential of 100 Mo -enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10 kg × d exposure: the two neutrino double-beta decay half-life of 100 Mo has been measured with the up-to-date highest accuracy as T 1 / 2 = [6.90 ± 0.15(stat.) ± 0.37(syst.)] × 10 18 years . Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of 100 Mo .

3.
Appl Radiat Isot ; 68(7-8): 1459-66; discussion 1466, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20106670

RESUMO

Sources of enriched (240)Pu were prepared by vacuum evaporation on quartz substrates. High-resolution alpha-particle spectrometry of (240)Pu was performed with high statistical accuracy using silicon detectors and with low statistical accuracy using a bolometer. The alpha-particle emission probabilities of six transitions were derived from the spectra and compared with literature values. Additionally, some alpha-particle emission probabilities were derived from gamma-ray intensity measurements with a high-purity germanium detector. The alpha-particle emission probabilities of the three main transitions at 5168.1, 5123.6 and 5021.2 keV were derived from seven aggregate spectra analysed with five different fit functions and the results were compatible with evaluated data. Two additional weak peaks at 4863.5 and 4492.0 keV were fitted separately, using the exponential of a polynomial function to represent the underlying tailing of the larger peaks. The peak at 4655 keV could not be detected by alpha-particle spectrometry, while gamma-ray spectrometry confirms that its intensity is much lower than expected from literature.

4.
Appl Radiat Isot ; 64(10-11): 1281-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16618545

RESUMO

Applications such as environment monitoring implying alpha emitters activity measurement associated with isotope identification, require high-energy resolution detectors. Conventional silicon detectors are inexpensive therefore widely used, although intrinsically limited in energy resolution. Thermal detection principle of cryogenic detectors introduces a breakthrough in alpha particle measurement. For the first time, spectra with 5.5 keV FWHM energy resolution have been obtained for several external alpha emitting sources using a copper-germanium bolometer specially developed for alpha spectrometry.


Assuntos
Partículas alfa , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Análise Espectral/instrumentação , Transdutores , Temperatura Baixa , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise Espectral/métodos
5.
Appl Radiat Isot ; 60(2-4): 363-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14987669

RESUMO

Cryogenic detectors offer remarkably better energy resolutions than those achievable with conventional semiconductor or scintillation detectors. With the additional asset of a detection efficiency close to unity for low-energy X-ray photons and electrons, these detectors have the potential to perform X-ray, gamma and electron spectroscopy of a hitherto unknown quality, in particular at low energies. Two types of cryogenic detectors are described and the results of prototype detectors are presented.


Assuntos
Calorimetria/instrumentação , Análise de Falha de Equipamento , Congelamento , Radioisótopos/análise , Radiometria/instrumentação , Análise Espectral/instrumentação , Termografia/instrumentação , Transdutores , Calorimetria/métodos , Desenho de Equipamento , Estudos de Viabilidade , Projetos Piloto , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria gama/instrumentação , Espectrometria gama/métodos , Espectrometria por Raios X/instrumentação , Espectrometria por Raios X/métodos , Análise Espectral/métodos , Integração de Sistemas , Termografia/métodos
6.
Appl Radiat Isot ; 56(1-2): 245-51, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11839023

RESUMO

Microcalorimeters (or bolometers) operated at temperatures below 100 mK allow individual counting of photons and electrons with a very low energy detection threshold. The physics is based on the pulse temperature increase of the target (or absorber) of the detector due to the complete absorption of both electrons and photons. Since this target can be constructed with a perfect 4-pi geometry, a bolometer offers potentially a new method for absolute activity measurements of radionuclides emitting low-energy radiation. In this paper we present our first results of a feasibility study of activity standardization of a 55Fe solution with a prototype 4-pi bolometer.

7.
Appl Radiat Isot ; 52(3): 403-6, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10724382

RESUMO

Due to the intrinsic performances of cryogenic detectors such as energy resolution, LPRI has decided to use these devices to improve the quality of the radioactive measurements usually obtained with classical semiconductor detectors. A bolometer with a 10 microg tin absorber has been developed at IAS (Institut d'Astrophysique Spatiale) and has been tested in the cryogenic installation of LPRI; an energy resolution (full width half maximum, FWHM) of 39 eV has been obtained on the Kalpha line of Mn. Besides these good spectrometry results, an absolute activity measurement using bolometers is proposed by adapting an absorber geometry for 4 pi counting.

8.
Phys Rev B Condens Matter ; 51(8): 5488-5490, 1995 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-9979439
9.
Icarus ; 76: 404-36, 1988.
Artigo em Inglês | MEDLINE | ID: mdl-11538667

RESUMO

The infrared instrument IKS flown on board the VEGA space probes was designed for the detection of emission bands of parent molecules, and for a measurement of the size and temperature of the thermal emitting nuclear region. The instrument had three channels with cooled detectors: an "imaging channel" designed to modulate the signal of the nucleus and two spectroscopic channels operating at 2.5-5 and 6-12 micrometers, respectively, equipped with circular variable filters of resolving power approximately 50. This paper presents and discusses the results from the spectral channels. On VEGA 1, usable spectra were obtained at distances D from the comet nucleus ranging from 250,000 to 40,000 km corresponding to fields of view 4000 and 700 km in diameter, respectively. The important internal background signal caused by the instrument itself, which could not be cooled, had to be eliminated. Since no sky chopping was performed, we obtain difference spectra between the current spectrum and a reference spectrum with little or no cometary signal taken at the beginning of the observing sequence (D approximately 200,000 km). Final discrimination between cometary signal and instrumental background is achieved using their different time evolution, since the instrumental background is proportional to the slow temperature drift of the instrument, and the cometary signal due to parent molecules or dust grains is expected to vary in first order as D-1. The 2.5-5 micrometers IKS spectra definitely show strong narrow signals at 2.7 and 4.25 micrometers, attributed to the nu 3 vibrational bands of H2O and CO2, respectively, and a broader signal in the region 3.2-3.5 micrometers, which may be attributed to CH-bearing molecules. All these signals present the expected D-1 intensity variation. Weaker emission features at 3.6 and 4.7 micrometers could correspond to the nu 1 and nu 5 bands of H2CO and the (1 - 0) band of CO, respectively. Molecular production rates are derived from the observed emissions, assuming that they are due to resonance fluorescence excited by the Sun's infrared radiation. For the strong bands of H2O and CO2, the rovibrational lines are optically thick, and radiative transfer is taken into account. We derive production rates, at the moment of the VEGA 1 flyby, of approximately 10(30) sec-1 for H2O, approximately 2.7 x 10(28) sec-1 for CO2, approximately 5 x 10(28) sec-1 for CO, and 4 x 10(28) sec-1 for H2CO, if attributions to CO and H2CO are correct. The production rate of carbon atoms in CH-bearing molecules is approximately 9 x 10(29) sec-1 assuming fluorescence of molecules in the gas phase, but could be much less if the 3.2-3.5 micrometers emission is attributed to C-H stretch in polycyclic aromatic hydrocarbons or small organic grains. In addition, marginal features are present at 4.85 and 4.45 micrometers, tentatively attributed to OCS and molecules with the CN group, respectively. Broad absorption at 2.8-3.0 micrometers, as well as a narrow emission at 3.15 micrometers, which follow well the D-1 intensity variation, might be due to water ice. Emission at 2.8 micrometers is also possibly present, and might be due to OH created in vibrationally excited states after water photodissociation. The 6-12 micrometers spectrum does not show any molecular emission, nor emission in the 7.5-micrometers region. The spectrum is dominated by silicate emission showing a double structure with maxima at 9.0 and 11.2 micrometers, which suggests the presence of olivine.


Assuntos
Astronomia/instrumentação , Meteoroides , Sistema Solar , Astronave/instrumentação , Espectrofotometria Infravermelho/métodos , Astronomia/métodos , Dióxido de Carbono/análise , Monóxido de Carbono/análise , Formaldeído/análise , Gelo/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Espectrofotometria Infravermelho/instrumentação , Análise Espectral , Temperatura , Água/análise
10.
Appl Opt ; 16(7): 1834-40, 1977 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-20168819

RESUMO

A Michelson interferometer has been built for use with the 91-cm telescope on NASA's Gerard P. Kuiper Airborne Observatory primarily to measure ir line emission from H 11 regions. Operation is in the rapid scan mode, and the achievable resolution is 0.02 cm(-1) in the wavelength range from 10 micro to around 300 micro. A minicomputer is used to provide on-line spectrum displays and to control and monitor the instrument performance. The design and use of the instrument is discussed, and a comparison is made between the theoretical performance and that actually achieved on the first flights when measurements of line emission from the Orion nebula and from the atmosphere were made.

11.
Appl Opt ; 12(12): 2863-8, 1973 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20125885

RESUMO

We present here a photometer and a low temperature calibration blackbody built to perform measurements of the submillimeter background emission of the sky (lambda > 500 micro).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...