Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38803387

RESUMO

INTRODUCTION: Cytisine is a smoking cessation drug now used worldwide. Most of the data available in the literature predict a 25-day treatment, accepted on the basis of previous clinical experience in Eastern Europe. There are few studies on dosing, and only recently some researchers have tried a longer treatment period. METHODS: This real-world retrospective cross-sectional study analyzed data collected consecutively from 2015 to 2021, in seven smoking cessation centers in north-central Italy. The aim of this study is to evaluate the effectiveness and tolerability of a 40-day cytisine treatment with an induction phase and a slower reduction schedule. Data were collected from a group of 871 patients treated with cysteine, varenicline, and nicotine replacement therapy (NRT). The sample was not randomized. Behavioral support (4-6 sessions, each lasting 20-30 min, plus the evaluation session) was delivered to all patients. RESULTS: Subgroups taking cytisine (n=543 for 40 days), varenicline (n=281 for 12 weeks), and NRT (n=47 for eight weeks) showed biochemically confirmed smoking abstinence at 6 months of 50.5%, 55.9%, and 51.0%, respectively, with a statistically significant difference between cytisine versus varenicline (p<0.01) but not between cytisine versus NRT (p=0.5597). Adverse events were 4.4% with cytisine and 33.3% with varenicline. Behavioral support was an important factor in effectiveness. CONCLUSIONS: This study produced preliminary evidence that the 40-day regimen of cytisine, appears to have less effectiveness in comparison to varenicline but the magnitude of the effect is comparable. The results and tolerability seem to be better than in most other studies.

2.
Radiol Med ; 122(5): 353-360, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28197872

RESUMO

PURPOSE: To compare the diagnostic accuracy of three-dimensional (3D) fast spin echo (FSE) intermediate-weighed (IW-3D) and 3D hybrid double-echo steady-state T1-weighted sequences (Hy-3D) and two-dimensional (FSE) images (2D) at shoulder MR arthrography (MRA). MATERIALS AND METHODS: Institutional review board approval was obtained and informed consent was waived for this retrospective study. From September 2011 to October 2014, 102 patients who had undergone 1.5 Tesla MRA of the shoulder, including conventional 2D-FSE and IW-3D and Hy-3D images were included in our study. The mean interval between MRA and surgery was 21 days (range 2-70 days). MR images were retrospectively and independently reviewed by two experienced radiologists blinded to the clinical and surgical data. Supraspinatus tendon (SST), infraspinatus tendon (IST) and subscapularis tendon (SCT) tears, as well as antero-inferior, superior and posterior labral lesions were assessed, using surgery as the reference standard. Each reader's performance in assessing rotator cuff and labrum abnormalities was evaluated using the area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CIs). The difference was evaluated using a univariate z test. The sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and accuracy (Acc) for all types of rotator cuff tears and labral lesions were calculated. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated using kappa statistics. RESULTS: The difference of diagnostic accuracy achieved was not significant (p > 0.05). In particular, differences in AUC values ranged from 0.002 (p = 0.98) to 0.014 (p = 0.82) as regards the comparison between 2D and IW-3D images, from 0.002 (p = 0.98) to 0.034 (p = 0.08) concerning the comparison between 2D and Hy-3D images and from 0.010 (p = 0.82) to 0.032 (p = 0.09) when comparing Hy-3D to IW-3D images. Accuracy values in evaluating RC lesions and labral lesions were 95.1, 92.1, 91.2, 93.1, 93.1 and 94.1% by reading 2D, Hy-3D and IW-3D images, respectively. The difference of diagnostic accuracy achieved using the datasets analyzed was not significant (p > 0.05). Inter-observer agreement was very good for each of the datasets that were evaluated, with near-perfect agreement for 2D dataset (k = 0.86), Hy-3D (k = 0.81) and IW-3D (k = 0.83). CONCLUSIONS: The accuracy of IW-3D and Hy-3D images was not significantly higher than the 2D sequences in evaluating RC and labral lesions.


Assuntos
Artrografia/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Lesões do Ombro , Articulação do Ombro/diagnóstico por imagem , Adolescente , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
3.
Drug Alcohol Depend ; 158: 147-53, 2016 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-26679060

RESUMO

BACKGROUND: Addiction is associated with dorso-lateral prefrontal cortex (DLPFC) dysfunction and altered brain-oscillations. High frequency repetitive transcranial magnetic stimulation (HFrTMS) over DLPFC reportedly reduces drug craving. Its effects on neuropsychological, behavioural and neurophysiological are unclear. METHODS: We assessed psychological, behavioural and neurophysiological effects of 4 sessions of 10-min adjunctive HFrTMS over the left DLPFC during two weeks during a residential programme for alcohol detoxification. Participants were randomized to active HFrTMS (10 Hz, 100% motor threshold) or sham. Immediately before the first and after the last session, 32-channels EEG was recorded and alcohol craving Visual Analogue Scale, Symptom Check List-90-R, Numeric Stroop task and Go/No-go task administered. Tests were repeated at 1-month follow-up. RESULTS: 17 subjects (mean age 44.7 years, 4 F) were assessed. Active rTMS subjects performed better at Stroop test at end of treatment (p=0.036) and follow up (p=0.004) and at Go-NoGo at end of treatment (p=0.05) and follow up (p=0.015). Depressive symptoms decreased at end of active treatment (p=0.036). Active-TMS showed an overall decrease of fast EEG frequencies after treatment compared to sham (p=0.026). No significant modifications over time or group emerged for craving and number of drinks at follow up. CONCLUSION: 4 HFrTMS sessions over two weeks on the left DLPFC can improve inhibitory control task and selective attention and reduce depressive symptoms. An overall reduction of faster EEG frequencies was observed. Nonetheless, this schedule is ineffective in reducing craving and alcohol intake.


Assuntos
Alcoolismo/psicologia , Alcoolismo/terapia , Comportamento Aditivo/psicologia , Comportamento Aditivo/terapia , Córtex Pré-Frontal , Estimulação Magnética Transcraniana/métodos , Adulto , Alcoolismo/fisiopatologia , Atenção/fisiologia , Comportamento Aditivo/fisiopatologia , Fissura/fisiologia , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Pré-Frontal/fisiopatologia , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
4.
World J Radiol ; 7(10): 319-28, 2015 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-26516428

RESUMO

Magnetic resonance imaging (MRI) is a reliable and accurate imaging method for the evaluation of patients with pancreatic ductal adenocarcinoma (PDAC). Diffusion-weighted imaging (DWI) is a relatively recent technological improvement that expanded MRI capabilities, having brought functional aspects into conventional morphologic MRI evaluation. DWI can depict the random diffusion of water molecules within tissues (the so-called Brownian motions). Modifications of water diffusion induced by different factors acting on the extracellular and intracellular spaces, as increased cell density, edema, fibrosis, or altered functionality of cell membranes, can be detected using this MR sequence. The intravoxel incoherent motion (IVIM) model is an advanced DWI technique that consent a separate quantitative evaluation of all the microscopic random motions that contribute to DWI, which are essentially represented by molecular diffusion and blood microcirculation (perfusion). Technological improvements have made possible the routine use of DWI during abdominal MRI study. Several authors have reported that the addition of DWI sequence can be of value for the evaluation of patients with PDAC, especially improving the staging; nevertheless, it is still unclear whether and how DWI could be helpful for identification, characterization, prognostic stratification and follow-up during treatment. The aim of this paper is to review up-to-date literature data regarding the applications of DWI and IVIM to PDACs.

5.
Australas J Ultrasound Med ; 17(3): 96-109, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28191218

RESUMO

Indication/purpose: To review contrast-enhanced ultrasound features of the most common pancreatic tumours. Methods: Contrast-enhanced ultrasound (CEUS) can provide distinctive features of pancreatic tumours that are reported in the present paper, providing radiologic-pathological correlations and clarifying the main differential diagnosis. Conclusion: Contrast-enhanced ultrasound plays a well-established role in the evaluation of pancreatic tumours. When possible, CEUS should be always performed after the initial US diagnosis, in order to improve the accuracy of the first line examination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...