Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Fr Ophtalmol ; 46(5): 510-517, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36890076

RESUMO

OBJECTIVE: To evaluate refractive, aberrometric, topographic, and topometric outcomes of asymmetric intracorneal ring segment (ICRS) implantation in snowman phenotype (asymmetric bow-tie) keratoconus. METHODS: This retrospective, interventional study included eyes with snowman phenotype keratoconus. Two asymmetric ICRSs (Keraring AS) were implanted after femtosecond laser-assisted tunnel formation. Visual, refractive, aberrometric, topographic, and topometric changes after asymmetric ICRS implantation were evaluated with a mean follow-up of 11 months (6-24 months). MAIN RESULTS: Seventy-one eyes were analyzed in the study. Keraring AS implantation corrected refractive errors significantly. The mean spherical error decreased from -5.06±4.23 D to -1.62±3.45 D (P=0.001), and the mean cylindrical error decreased from -5.43±2.48 D to -2.44±1.49 D (P=0.001). Uncorrected distance visual acuity improved from 0.98±0.80 to 0.46±0.46 Log MAR (P=0.001), and corrected distance visual acuity improved from 0.58±0.56 to 0.17±0.39 Log MAR (P=0.001). Keratometry (K) maximum, K1, K2, K mean, astigmatism, and corneal asphericity (Q-value) showed a significant decrease (P=0.001). Vertical coma aberration decreased significantly from -3.31±2.12µm to -2.56±1.94µm (P=0.001). All topometric indices of corneal irregularities were significantly reduced postoperatively (P=0.001). CONCLUSIONS: Keraring AS implantation in snowman phenotype keratoconus demonstrated good efficacy and safety. Clinical, topographic, topometric, and aberrometric parameters improved significantly after Keraring AS implantation.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Ceratocone/cirurgia , Implantação de Prótese , Substância Própria/cirurgia , Estudos Retrospectivos , Topografia da Córnea , Refração Ocular , Próteses e Implantes , Olho Artificial
2.
J Fr Ophtalmol ; 45(4): 377-383, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35093264

RESUMO

OBJECTIVE: To evaluate changes in biometric variables and intraocular lens (IOL) calculation results after posterior chamber phakic IOL (PCPIOL) implantation. METHODS: This retrospective, observational study included 65 eyes of 38 patients who underwent PCPIOL (EVO Visian ICL) implantation for correction of myopia. Prior to and a minimum of one year (mean 14.9 months) after EVO Visian ICL implantation, biometric variables and IOL calculation results were compared. Optical biometry, including anterior chamber depth, axial length, flat, steep, and mean keratometry values and IOL calculation results for the Holladay 2, Hoffer Q, Haigis, and SRK/T formulas were measured using the IOLMaster 700 SWEPT Source OCT biometer. MAIN RESULTS: The mean anterior chamber depth decreased from 3.70±0.22mm to 3.34±0.39mm, the mean axial length increased from 26.61±1.61mm to 26.71±1.66mm, and the mean flat keratometry changed from 42.82±1.86 D to 42.73±1.83 D. These changes were statistically significant. The mean IOL power calculation also revealed a statistically significant decrease with all four formulas (ranging from 0.19 D to 0.30 D) after PCPIOL implantation. CONCLUSIONS: Biometric variables and IOL calculation results showed statistically significant changes one year after EVO Visian ICL implantations. However, IOL power calculations yielded a decrease of less than 0.50 D, inducing much less refractive deviation in the spectacle plane; and the change was primarily related to an increase in AL measurements. IOL power calculations in eyes with EVO Visian ICL in situ provided satisfactory and reliable results.


Assuntos
Lentes Intraoculares , Facoemulsificação , Biometria/métodos , Córnea , Humanos , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Óptica e Fotônica , Facoemulsificação/métodos , Refração Ocular , Estudos Retrospectivos