Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Legal Med ; 136(5): 1201-1210, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35355113

RESUMO

The present research assessed how the physical and chemical changes associated with decomposition affect the detection and identification of blood and semen evidence, as well as subsequent DNA analysis. A feeder pig (postmortem interval (PMI) < 3 h) was placed within the Boston University Outdoor Research Facility for a period of 22 days. Human blood and semen were individually dispensed onto multiple areas of two cotton t-shirts; one layer of fabric was placed above and below the pig and a control. One of each sample type was collected per day for a period of 22 days from each location. It was observed that both sample types when collected from beneath the pig exhibited the greatest decline in enzymatic activity over the course of testing, followed by samples from beneath the control, which can be inferred from the increase in negative screening results compared to the other samples. Spermatozoa were observed in nearly all semen samples, even when all screening results were negative, which lead to the generation of comparable DNA profiles for nearly all semen samples typed. Genetic typing of the blood samples beneath the pig and control rarely yielded comparable data while the samples from above yielded full profiles for all but a few samples tested.


Assuntos
Mudanças Depois da Morte , Sêmen , Animais , DNA/análise , Humanos , Masculino , Sêmen/química , Espermatozoides/química , Suínos
2.
Forensic Sci Int Genet ; 37: 235-240, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30261423

RESUMO

When DNA profiles contain a mixture of contributors (N), the maximum number of alleles observed at any locus is 2 N with the number of alleles varying between 1 and 2 N. The number of possible combinations of the genotypes of the N contributors increases as N increases. The number of possible combinations of genotypes that may occur among the N contributors can be enumerated using the mathematical concept of ordered partitions. Thus the number of possible genotype combinations which can exist at an STR locus in a DNA sample having N contributors and L observed alleles at the locus can be calculated. Development of the calculation and the resulting number of possible combinations which exist for N ≤ 8 contributors is presented. The results for ≥ three contributors indicate that deconvolution of contributing genotypes using manual methods is precluded except in circumstances where a clear major contributor can identified.


Assuntos
DNA/genética , Genótipo , Conceitos Matemáticos , Alelos , DNA/análise , Humanos
3.
Forensic Sci Int Genet ; 18: 66-77, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25817211

RESUMO

Forensic DNA testing is grounded in molecular biology and population genetics. The technologies that were the basis of restriction length polymorphism testing (RFLP) have given way to PCR based technologies. While PCR has been the pillar of short tandem repeat (STR) methods and will continue to be used as DNA sequencing and analysis of single nucleotide polymorphisms (SNPs) are introduced into human identification, the molecular biology techniques in use today represent significant advances since the introduction of STR testing. Large forensic laboratories with dedicated research teams and forensic laboratories which are part of academic institutions have the resources to keep track of advances which can then be considered for further research or incorporated into current testing methods. However, many laboratories have limited ability to keep up with research advances outside of the immediate area of forensic science and may not have access to a large university library systems. This review focuses on filling this gap with respect to areas of research that intersect with selected methods used in forensic biology. The review summarizes information collected from several areas of the scientific literature where advances in molecular biology have produced information relevant to DNA analysis of sexual assault evidence and methods used in presumptive and confirmatory identification of semen. Older information from the literature is also included where this information may not be commonly known and is relevant to current methods. The topics selected highlight (1) information from applications of proteomics to sperm biology and human reproduction, (2) seminal fluid proteins and prostate cancer diagnostics, (3) developmental biology of sperm from the fertility literature and (4) areas where methods are common to forensic analysis and research in contraceptive use and monitoring. Information and progress made in these areas coincide with the research interests of forensic biology and cross-talk between these disciplines may benefit both.


Assuntos
Anticoncepção/métodos , Reprodução/fisiologia , Sêmen/fisiologia , Espermatozoides/fisiologia , DNA/genética , Impressões Digitais de DNA/métodos , Genética Forense/métodos , Ciências Forenses/métodos , Humanos , Masculino , Repetições de Microssatélites , Reação em Cadeia da Polimerase/métodos , Polimorfismo de Nucleotídeo Único , Sêmen/química , Sêmen/citologia , Espermatozoides/química , Espermatozoides/citologia
4.
J Forensic Sci ; 58(3): 744-52, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23550664

RESUMO

The purpose of this study was to determine the effect Proteinase K, sodium dodecyl sulfate (SDS), incubation times, and temperatures had on differential extraction efficiencies and the premature lysis of spermatozoa. The effect was measured using Quantifiler® Duo and Identifiler™ PCR Amplification kits, where the resultant male and female DNA concentrations and their ratios within the nonsperm- and sperm fractions (SFs) were determined. Comparisons between expected and observed ratios illustrate the quantity of female DNA in the SF increased when Proteinase K was absent during the initial incubation. Additionally, there is no indication of simultaneous sperm and epithelial cell lysis in the absence of DTT at Proteinase K concentrations ranging from 10 to 300 µg/mL. All other conditions exhibited minimal variation in DNA concentration. Therefore, despite the various protocols used for the differential lysis of cell mixtures encountered in casework, the method is robust and successful at most conditions.


Assuntos
DNA/isolamento & purificação , Sêmen/química , Manejo de Espécimes/métodos , Espermatozoides/citologia , Sobrevivência Celular , Endopeptidase K , Células Epiteliais/citologia , Feminino , Genética Forense , Humanos , Masculino , Reação em Cadeia da Polimerase , Dodecilsulfato de Sódio , Tensoativos , Temperatura
5.
J Forensic Sci ; 58(1): 120-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23130820

RESUMO

Determining appropriate analytical thresholds (ATs) for forensic DNA analysis is critical to maximize allele detection. In this study, six methods to determine ATs for forensic DNA purposes were examined and compared. Four of the methods rely on analysis of the baseline noise of a number of negatives, while two utilize the relationship between relative fluorescence unit signal and DNA input in the polymerase chain reaction (PCR) derived from a dilution series ranging from 1 to 0.06 ng. Results showed that when a substantial mass of DNA (i.e., >1 ng) was amplified, the baseline noise increased, suggesting the application of an AT derived from negatives should only be applied to samples with low levels of DNA. Further, the number and intensity of these noise peaks increased with increasing injection times, indicating that to maximize the ability to detect alleles, ATs should be validated for each post-PCR procedure employed.


Assuntos
Impressões Digitais de DNA , Modelos Genéticos , Alelos , DNA/análise , DNA/genética , Eletroforese Capilar , Humanos , Reação em Cadeia da Polimerase , Razão Sinal-Ruído , Espectrofotometria Ultravioleta
6.
J Forensic Sci ; 55(5): 1331-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20629910

RESUMO

Reproducibility of quantitative PCR results is dependent on the generation of consistent calibration curves via accurate volume transfers and instrument performance. A review of 14 standard curves, using two different QuantDuo® standard DNA lots, showed variability of cycle threshold values between assays were larger than those of the Internal PCR Control (IPC). This prompted a set of experiments designed to determine the source of variability. Results showed that error introduced during DNA addition to the plate resulted in little variation. A comparison of seven independent series demonstrated cycle threshold variation between dilutions was larger than the variation expected from repeated samples. Modeling the influence of pipette errors on dilution series accuracy indicated that a more rigorous approach to external calibration curve production is required and showed that improvement in calibration curve stability is expected if the pipette conditions are carefully chosen and / or a single validated curve is utilized as the calibrator.


Assuntos
DNA/análise , Reação em Cadeia da Polimerase/instrumentação , Calibragem , Feminino , Humanos , Modelos Lineares , Masculino , Reprodutibilidade dos Testes
7.
J Forensic Sci ; 51(4): 758-65, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16882216

RESUMO

A duplex real-time quantitative PCR assay was developed for forensic DNA analysis, which provides simultaneous quantitation of total genomic human DNA and human male DNA. The assay utilizes two spectrally resolved fluorogenic probes in a 5' nuclease (TaqMantrade mark) assay. Within the range of organisms empirically tested and based upon theoretical specificity using National Center for Biotechnology Information GenBank sequences, primer and probe sequences were shown to be human specific, and the Y-chromosome probe, male-specific. A mixture-challenge study resulted in accurate quantitation of 25 pg male DNA in a mixture of up to 1:5000 (male:female DNA). Additional experimental results include comparisons with the slot blot method and commercial real-time PCR kits. The assay developed addresses the shortcomings of the traditional slot blot method as well as the commercial real-time PCR kits. This method is shown to be specific, relatively simple, rapid, has low limits of detection, and consumes limited sample in addition to reporting both the male and total genomic DNA concentrations present.


Assuntos
Impressões Digitais de DNA/métodos , DNA/análise , Reação em Cadeia da Polimerase/métodos , Cromossomos Humanos Y , Primers do DNA , Sondas de DNA , Humanos , Masculino , Sequências de Repetição em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...