1.
J AOAC Int ; 91(4): 833-52, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18727544

RESUMO

A collaborative study was conducted to validate the quantitative Three Step Method (TSM), a method designed to measure the performance of liquid sporicides on a hard nonporous surface. Ten laboratories agreed to participate in the collaborative study; data from 8 of 10 participating laboratories were used in the final statistical analysis. The TSM uses 5 x 5 x 1 mm glass coupons (carriers) upon which spores have been inoculated and which are introduced into liquid sporicidal agent contained in a microcentrifuge tube. Following exposure to a test chemical and a neutralization agent, spores are removed from carriers in 3 fractions: passive removal (Fraction A), sonication (Fraction B), and gentle agitation (Fraction C). Liquid from each fraction is serially diluted and plated on a recovery medium for spore enumeration. Control counts are compared to the treated counts, and the level of efficacy is determined by calculating the log10 reduction (LR) of spores. The main statistical goals were to evaluate the repeatability and reproducibility of the LR values, to estimate the components of variance for LR, and to assess method responsiveness. AOAC Method 966.04-Method II was used as a reference method. The scope of the validation was limited to testing liquid formulations against spores of Bacillus subtilis, a surrogate for virulent strains of B. anthracis, on a hard nonporous surface (glass). The test chemicals used in the study were sodium hypochlorite, a combination of peracetic acid and hydrogen peroxide, and glutaraldehyde. Each test chemical was evaluated at 3 levels of presumed efficacy: high, medium, and low. Three replications were required. The TSM was validated as it successfully met the statistical parameters for quantitative test methods. Satisfactory validation parameters, such as the repeatability standard deviation (Sr) and reproducibility standard deviation (SR), were obtained for control carrier counts and LR values. Both the TSM and the reference method were responsive to the efficacy levels of the test chemicals. For the 72 total TSM tests conducted, the mean (+/- standard error of the mean) log density of spores per control carrier was 6.86 (+/- 0.08); the Sr and SR were low at 0.15 and 0.27, respectively. Across the range of test chemicals, the Sr and SR estimates associated with LR were also acceptably low. The Sr ranged from 0.17 to 0.72 and the SR ranged from 0.34 to 1.43. Overall, the Sr and SR estimates associated with the efficacy data were within the ranges published for other quantitative methods and meet the performance characteristics necessary for validation.


Assuntos
Antibacterianos/farmacologia , Bacillus subtilis/efeitos dos fármacos , Esporos Bacterianos/efeitos dos fármacos , Análise de Variância , Bacillus anthracis/efeitos dos fármacos , Bioensaio , Calibragem , Meios de Cultura , Desinfetantes/farmacologia , Glutaral/farmacologia , Ácido Clorídrico/farmacologia , Indicadores e Reagentes , Oxidantes/farmacologia , Ácido Peracético/farmacologia , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Hipoclorito de Sódio/farmacologia , Propriedades de Superfície , Microbiologia da Água
2.
J AOAC Int ; 89(6): 1629-34, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17225612

RESUMO

The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.


Assuntos
Contagem de Colônia Microbiana/métodos , Pseudomonas aeruginosa , Staphylococcus aureus , Meios de Cultura , Técnicas de Diluição do Indicador , Indicadores e Reagentes , Controle de Qualidade , Estados Unidos , United States Environmental Protection Agency