1.
Artigo em Inglês | MEDLINE | ID: mdl-12705978

RESUMO

A selective, accurate, and reproducible LC-MS-MS assay was developed for the determination of the HIV protease inhibitor atazanavir (BMS-232632) in human plasma samples. The method involved automated solid-phase extraction of atazanavir and a stable isotope analog internal standard (I.S.) using Oasis HLB 10 mg 96-well SPE plates. A portion of the reconstituted sample residue was injected onto a C(18) HDO analytical column which was configured with a triple quad mass spectrometer for analyte determination by positive ion electrospray. The assay was linear from 1.00 to 1,000 ng/ml with a lower limit of quantitation of 1.00 ng/ml. The inter- and intra-day coefficients of variation (C.V.) for the assay were <4%, and the accuracy was 99-102%. Atazanavir was stable in human plasma for at least 109 h at room temperature and for at least 1 year at -20 degrees C.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Inibidores da Protease de HIV/sangue , Espectrometria de Massas/métodos , Oligopeptídeos/sangue , Piridinas/sangue , Sulfato de Atazanavir , Automação , Calibragem , Humanos , Padrões de Referência , Sensibilidade e Especificidade