Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Atmos Pollut Res ; 11(6): 81-86, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32699520

RESUMO

Select volatile organic compounds (VOCs) were measured in the vicinity of chemical facilities and other operations in the Rubbertown industrial area of Louisville, Kentucky (USA) using modified EPA Methods 325A/B passive sampler tubes. Two-week, time-integrated passive samplers were deployed at ten sites which were aggregated into three site groups of varying distances from the Rubbertown area facilities. In comparison to canister data from 2001 to 2005, two of the sites suggested generally lower current VOC levels. Good precision was obtained from the duplicate tubes (≤ 12%) for benzene, toluene, ethylbenzene, and xylene isomers (BTEX), styrene, 1,3-butadiene, perchloroethylene, and other trace VOCs. BTEX, styrene, and 1,3-butadiene concentrations were statistically significantly higher at two site groups near Rubbertown sources than the site group farther away. As found in a similar study in South Philadelphia, BTEX concentrations were also lower for sites farther from a source, though the decline was less pronounced on a percentage basis in Rubbertown. These results suggest that EPA Methods 325A/B can be useful to assess VOC gradients for emissions from chemical facilities besides fenceline benzene levels from refineries.

2.
Artigo em Inglês | MEDLINE | ID: mdl-31181783

RESUMO

Industrial facilities and other sources can emit air pollutants from fugitive leaks, process malfunctions and area sources that can be difficult to understand and to manage. Next generation emissions measurement (NGEM) approaches executed near facilities are enabling new ways to assess these sources and their impacts to nearby populations. This paper describes complementary uses of emerging NGEM systems in a Louisville, KY industrial district (Rubbertown), focusing on an important area air toxic, 1,3-butadiene. Over a one-year deployment starting in September 2017, two-week average passive samplers (PSs) at 11 sites showed both geospatial and temporal trends. At 0.24 ppbv annual average 1,3-butadiene concentration, a group of PSs located near facility fence lines was elevated compared to a PS group located in the community and upwind from facilities (0.07 ppbv average). Two elevated PS periods capturing emission events were examined using time-resolved NGEM approaches as case studies. In one event a 1.18 ppbv PS reading was found to be relatively localized and was caused by a multiday emission from a yet to be identified, non-facility source. In the other event, the airshed was more broadly impacted with PS concentrations ranging from 0.71 ppbv for the near-facility group to 0.46 ppbv for the community group. This case was likely influenced by a known emission event at an industrial facility. For both case studies, air pollutant and wind data from prototype NGEM systems were combined with source location models to inform the emission events. This research illustrates the power of applying NGEM approaches to improve both the understanding of emissions near sources and knowledge of impacts to near-source communities.


Assuntos
Poluentes Atmosféricos/análise , Butadienos/análise , Monitoramento Ambiental/métodos , Indústrias , Kentucky , Vento
3.
J Air Waste Manag Assoc ; 68(2): 170-175, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29244616

RESUMO

Select volatile organic compounds (VOCs) in ambient air were measured at four fenceline sites at a petroleum refinery in Whiting, IN, using modified EPA Method 325 A/B with passive tubes and EPA Compendium Method TO-15 with canister samplers. One-week, time-integrated samplers were deployed for 8 weeks with tubes and canister samplers deployed in duplicate. Good precision was obtained from the duplicate tubes (<7%) and duplicate canisters (≤10%) for BTEX, perchloroethylene, and styrene. The tubes yielded statistically significantly higher concentrations than canisters for benzene, toluene, ethylbenzene, and m,p-xylene. However, all differences were estimated to be <0.1 ppbv. No concentration differences among the four Whiting sites were found for any of the VOCs. IMPLICATIONS: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at refinery fenceline locations. This pilot study presents VOC data applying a modified version of EPA Method 325 A/B and its comparison to EPA Compendium Method TO-15 canister samplers at four refinery fenceline sites. The findings from this study provide additional confidence in application of the tube method at refineries to ascertain VOC source influence since tube and canister samplers were comparable and good precision was obtained from duplicate sampling for both methods. No overall difference in these reported VOC concentrations was found between Whiting sites for tubes or canisters.


Assuntos
Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Indústria de Petróleo e Gás , Compostos Orgânicos Voláteis/análise , Indiana , Projetos Piloto , Compostos Orgânicos Voláteis/química
4.
Atmos Environ (1994) ; 163: 99-106, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30505204

RESUMO

A sample integrity evaluation and an interlaboratory comparison were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A and 325B for diffusively monitoring benzene and other selected volatile organic compounds (VOCs) using Carbopack X sorbent tubes. To evaluate sample integrity, VOC samples were refrigerated for up to 240 days and analyzed using thermal desorption/gas chromatography-mass spectrometry at the EPA Office of Research and Development laboratory in Research Triangle Park, NC, USA. For the interlaboratory comparison, three commercial analytical laboratories were asked to follow Method 325B when analyzing samples of VOCs that were collected in field and laboratory settings for EPA studies. Overall results indicate that the selected VOCs collected diffusively on sorbent tubes generally were stable for 6 months or longer when samples were refrigerated. This suggests the specified maximum 30-day storage time of VOCs collected diffusively on Carbopack X passive samplers and analyzed using Method 325B might be able to be relaxed. Interlaboratory comparison results were in agreement for the challenge samples collected diffusively in an exposure chamber in the laboratory, with most measurements within ±25% of the theoretical concentration. Statistically significant differences among laboratories for ambient challenge samples were small, less than 1 part per billion by volume (ppbv). Results from all laboratories exhibited good precision and generally agreed well with each other.

5.
J Air Waste Manag Assoc ; 66(10): 959-70, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27192142

RESUMO

UNLABELLED: From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/°C, R(2) = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv. IMPLICATIONS: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.


Assuntos
Poluentes Atmosféricos/análise , Benzeno/análise , Monitoramento Ambiental , Philadelphia , Estações do Ano , Tempo (Meteorologia)
6.
J Air Waste Manag Assoc ; 66(5): 492-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26828464

RESUMO

UNLABELLED: Select volatile organic compounds (VOCs) were measured in the vicinity of a petroleum refinery and related operations in South Philadelphia, Pennsylvania, USA, using passive air sampling and laboratory analysis methods. Two-week, time-integrated samplers were deployed at 17 sites, which were aggregated into five site groups of varying distances from the refinery. Benzene, toluene, ethylbenzene, and xylene isomers (BTEX) and styrene concentrations were higher near the refinery's fenceline than for groups at the refinery's south edge, mid-distance, and farther removed locations. The near fenceline group was significantly higher than the refinery's north edge group for benzene and toluene but not for ethylbenzene or xylene isomers; styrene was lower at the near fenceline group versus the north edge group. For BTEX and styrene, the magnitude of estimated differences generally increased when proceeding through groups ever farther away from the petroleum refining. Perchloroethylene results were not suggestive of an influence from refining. These results suggest that emissions from the refinery complex contribute to higher concentrations of BTEX species and styrene in the vicinity of the plant, with this influence declining as distance from the petroleum refining increases. IMPLICATIONS: Passive sampling methodology for VOCs as discussed here is employed in recently enacted U.S. Environmental Protection Agency Methods 325A/B for determination of benzene concentrations at refinery fenceline locations. Spatial gradients of VOC concentration near the refinery fenceline were discerned in an area containing traffic and other VOC-related sources. Though limited, these findings can be useful in application of the method at such facilities to ascertain source influence.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Análise Espacial , Compostos Orgânicos Voláteis/análise , Monitoramento Ambiental/instrumentação , Philadelphia
7.
J Air Waste Manag Assoc ; 66(4): 412-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26771215

RESUMO

UNLABELLED: A pilot study was conducted in application of the U.S. Environmental Protection Agency (EPA) Methods 325A/B variant for monitoring volatile organic compounds (VOCs) near two oil and natural gas (ONG) production well pads in the Texas Barnett Shale formation and Colorado Denver-Julesburg Basin (DJB), along with a traffic-dominated site in downtown Denver, CO. As indicated in the EPA method, VOC concentrations were measured for 14-day sampling periods using passive-diffusive tube samplers with Carbopack X sorbent at fenceline perimeter and other locations. VOCs were significantly higher at the DJB well pad versus the Barnett well pad and were likely due to higher production levels at the DJB well pad during the study. Benzene and toluene were significantly higher at the DJB well pad versus downtown Denver. Except for perchloroethylene, VOCs measured at passive sampler locations (PSs) along the perimeter of the Barnett well pad were significantly higher than PSs farther away. At the DJB well pad, most VOC concentrations, except perchloroethylene, were significantly higher prior to operational changes than after these changes were made. Though limited, the results suggest passive samplers are precise (duplicate precision usually ≤10%) and that they can be useful to assess spatial gradients and operational conditions at well pad locations over time-integrated periods. IMPLICATIONS: Recently enacted EPA Methods 325A/B use passive-diffusive tube samplers to measure benzene at multiple fenceline locations at petrochemical refineries. This pilot study presents initial data demonstrating the utility of Methods 325A/B for monitoring at ONG facilities. Measurements revealed elevated concentrations reflective of production levels and spatial gradients of VOCs relative to source proximity at the Barnett well pad, as well as operational changes at the DJB well pad. Though limited, these findings indicate that Methods 325A/B can be useful in application to characterize VOCs at well pad boundaries.


Assuntos
Monitoramento Ambiental/métodos , Campos de Petróleo e Gás , Compostos Orgânicos Voláteis/análise , Colorado , Projetos Piloto , Texas
8.
Artigo em Inglês | MEDLINE | ID: mdl-32636605

RESUMO

From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/°C, R2 = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv. IMPLICATIONS: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...