Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 88(4): 043501, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28456222

RESUMO

A new collimated filtered thermoluminescent dosimeter (TLD) array has been developed at the Z facility to characterize warm x-rays (hν > 10 keV) produced by Z pinch radiation sources. This array includes a Kapton debris shield assembly to protect the TLDs from the source debris, a collimator array to limit the field of view of the TLDs to the source region, a filter wheel containing filters of aluminum, copper and tungsten up to 3 mm thick to independently filter each TLD, and a hermetically sealed cassette containing the TLDs as well as tungsten shielding on the sides and back of the array to minimize scattered radiation reaching the TLDs. Experimental results from a krypton gas puff and silver wire array shot are analyzed using two different functional forms of the energy spectrum to demonstrate the ability of this diagnostic to consistently extend the upper end of the x-ray spectrum characterization from ∼50 keV to >1 MeV.

2.
Phys Rev Lett ; 111(3): 035001, 2013 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-23909333

RESUMO

Detailed spectroscopic diagnostics of the stagnating plasma in two disparate z pinches allow, for the first time, the examination of the plasma properties within a 1D shock wave picture, demonstrating a good agreement with this picture. The conclusion is that for a wide range of imploding-plasma masses and current amplitudes, in experiments optimizing non-Planckian hard radiation yields, contrary to previous descriptions the stagnating plasma pressure is balanced by the implosion pressure, and the radiation energy is provided by the imploding-plasma kinetic energy, rather than by the magnetic-field pressure and magnetic-field-energy dissipation, respectively.

3.
Phys Rev E Stat Nonlin Soft Matter Phys ; 84(5 Pt 2): 056408, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22181529

RESUMO

The observation of Doppler splitting in K-shell x-ray lines emitted from optically thin dopants is used to infer implosion velocities of up to 70 cm/µs in wire-array and gas-puff Z pinches at drive currents of 15-20 MA. These data can benchmark numerical implosion models, which produce reasonable agreement with the measured velocity in the emitting region. Doppler splitting is obscured in lines with strong opacity, but red-shifted absorption produced by the cooler halo of material backlit by the hot core assembling on axis can be used to diagnose velocity in the trailing mass.


Assuntos
Física/métodos , Absorção , Algoritmos , Desenho de Equipamento , Magnetismo , Movimento (Física) , Espectrofotometria/métodos , Fatores de Tempo , Água/química , Raios X
4.
Rev Sci Instrum ; 82(6): 063113, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21721680

RESUMO

We describe a pair of time-integrated transmission spectrometers that are designed to survey 7-28 keV (1.9 to 0.43 Å) x-ray photons produced by experiments on the Sandia Z pulsed power facility. Each spectrometer uses a quartz 10-11 crystal in a Cauchois geometry with a slit to provide spatial resolution along one dimension. The spectrometers are located in the harsh environment of the Z vacuum chamber, which necessitates that their design be compact and rugged. Example data from calibration tests and Z experiments are shown that illustrate the utility of the instruments.

5.
Phys Rev Lett ; 104(12): 125001, 2010 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-20366539

RESUMO

An indirect drive configuration is proposed wherein multiple compact Z-pinch x-ray sources surround a secondary hohlraum. Planar compact wire arrays allow reduced primary hohlraum surface area compared to cylindrical loads. Implosions of planar arrays are studied at up to 15 TW x-ray power on Saturn with radiated yields exceeding the calculated kinetic energy, suggesting other heating paths. X-ray power and yield scaling studied from 1-6 MA motivates viewfactor modeling of four 6-MA planar arrays producing 90 eV radiation temperature in a secondary hohlraum.

6.
Phys Rev Lett ; 102(15): 155006, 2009 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-19518644

RESUMO

Experiments with cylindrical copper wire arrays at the 1-MA Zebra facility show that high temperatures exist in the precursor plasmas formed when ablated wire array material accretes on the axis prior to the stagnation of a z pinch. In these experiments, the precursor radiated approximately 20% of the >1000 eV x-ray output, and time-resolved spectra show substantial emission from Cu L-shell lines. Modeling of the spectra shows an increase in temperature as the precursor forms, up to approximately 450 eV, after which the temperature decreases to approximately 220-320 eV until the main implosion.

7.
Rev Sci Instrum ; 79(10): 10E315, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044477

RESUMO

Tracer aluminum alloyed wires (Al5056) are used to provide additional information for x-ray diagnostics of implosions of Cu planar wire arrays (PWAs). Specifically, the analysis of combined PWA experiments using the extensive set of x-ray diagnostics is presented. In these experiments, which were conducted at the 1MA pulsed power generator at University of Nevada, Reno, the Z-pinch load consisted of several (eight) Cu alloyed (main material) and one to two Al alloyed (tracer) wires mounted in a single plane row or double parallel plane rows, single planar wire array (SPWA) or double planar wire array (DPWA), respectively. The analysis of x-ray spatially resolved spectra from the main material indicates the increase in the electron temperature T(e) near the cathode. In general, the axial gradients in T(e) are more pronounced for SPWA than for DPWA due to the more "columnlike" plasma formation for SPWA compared to "hot-spot-like" plasma formation for DPWA. In addition, x-ray spectra from tracer wires are studied, and estimated plasma parameters are compared with those from the main material. It is observed that the x-ray K-shell Al spectra manifest more opacity features for the case of SPWA with about 18% of Al mass (to the total load mass) compared to the case of DPWA with about 11% of Al mass. The analysis of time-gated spectra shows that the relative intensity of the most intense K-shell Al line, small before the x-ray burst, increases with time and peaks close to the maximum of the sub-keV signal.

8.
Rev Sci Instrum ; 79(10): 10E906, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044561

RESUMO

A multicolor, time-gated, soft x-ray pinhole imaging instrument is fielded as part of the core diagnostic set on the 25 MA Z machine [M. E. Savage et al., in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, New York, 2007), p. 979] for studying intense wire array and gas puff Z-pinch soft x-ray sources. Pinhole images are reflected from a planar multilayer mirror, passing 277 eV photons with <10 eV bandwidth. An adjacent pinhole camera uses filtration alone to view 1-10 keV photons simultaneously. Overlaying these data provides composite images that contain both spectral as well as spatial information, allowing for the study of radiation production in dense Z-pinch plasmas. Cu wire arrays at 20 MA on Z show the implosion of a colder cloud of material onto a hot dense core where K-shell photons are excited. A 528 eV imaging configuration has been developed on the 8 MA Saturn generator [R. B. Spielman et al., and A. I. P. Conf, Proc. 195, 3 (1989)] for imaging a bright Li-like Ar L-shell line. Ar gas puff Z pinches show an intense K-shell emission from a zippering stagnation front with L-shell emission dominating as the plasma cools.

9.
Phys Rev Lett ; 100(10): 105003, 2008 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-18352197

RESUMO

Axially localized NaF dopants are coated onto Al cylindrical wire arrays in order to act as spectroscopic tracers in the stagnated z-pinch plasma. Non-local-thermodynamic-equilibrium kinetic models fit to Na K-shell lines provide an independent measurement of the density and temperature that is consistent with spectroscopic analysis of K-shell emissions from Al and an alloyed Mg dopant. Axial transport of the Na dopant is observed, enabling quantitative study of instabilities in dense z-pinch plasmas.

10.
Phys Rev Lett ; 97(12): 125001, 2006 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-17025975

RESUMO

The dynamics of mass transport were observed in a wire array implosion with multiframe laser probing. Plasma bubbles arise at breaks in the wires. Interferometry shows that the leading edge of the bubbles brings material to the axis of the array. The speed of this material was measured to be > or =3 x 10(7) cm/s during the wire array implosion. A shock was observed during the collision of the bubbles with the precursor. The Faraday effect indicates current flowing in breaks on the wires. The current switches from the imploding mass to the on-axis plasma column at the beginning of the x-ray pulse.

11.
Phys Rev Lett ; 96(7): 075003, 2006 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-16606100

RESUMO

Pulsed power driven metallic wire-array Z pinches are the most powerful and efficient laboratory x-ray sources. Furthermore, under certain conditions the soft x-ray energy radiated in a 5 ns pulse at stagnation can exceed the estimated kinetic energy of the radial implosion phase by a factor of 3 to 4. A theoretical model is developed here to explain this, allowing the rapid conversion of magnetic energy to a very high ion temperature plasma through the generation of fine scale, fast-growing m = 0 interchange MHD instabilities at stagnation. These saturate nonlinearly and provide associated ion viscous heating. Next the ion energy is transferred by equipartition to the electrons and thus to soft x-ray radiation. Recent time-resolved iron spectra at Sandia confirm an ion temperature Ti of over 200 keV (2 x 10(9) degrees), as predicted by theory. These are believed to be record temperatures for a magnetically confined plasma.

12.
Phys Rev Lett ; 93(15): 155001, 2004 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-15524890

RESUMO

Nested-wire array experiments have been conducted at the 7 MA level with 150 ns implosion times from an outer diameter of 40 mm. Analysis of spectral data indicates that material from the outer array preferentially occupies the high temperature core of the stagnated pinch independent of the interwire gap in the range of 1.1 to 4.5 mm.

13.
Phys Rev Lett ; 88(6): 065001, 2002 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-11863814

RESUMO

Experiments performed on the 8-MA Saturn accelerator to investigate the effects of interwire gap spacing on long-implosion-time Z pinches have resulted in the observation of a regime of optimal wire number. The experiments varied the wire number of 40 and 32 mm diam arrays, resulting in interwire gaps from 3.9 to 0.36 mm, with fixed mass and length. aluminum K-shell powers up to 3.4 TW were measured, with long, slow rising, lower power x-ray pulses for interwire gaps greater than 2.2 mm and less than 0.7 mm, and short, fast rising, higher power pulses for interwire gaps in the range 0.7-2.2 mm.

15.
Opt Lett ; 17(7): 523-5, 1992 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19794546

RESUMO

By measuring the spectrum of the backscattered light from a short-pulse laser-produced plasma in a gas jet, a direct and highly accurate measurement of the local electron density can be obtained. The measurement is based on the density-dependent spectral shift of the backscattered Raman wave.

16.
J Clin Pathol ; 42(4): 409-13, 1989 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2785534

RESUMO

Strains of Haemophilus influenzae (n = 161) were isolated from inpatients with symptoms of pulmonary infection. Conventional tests showed that 144 strains were non-serotypable and all belonged to one of eight biotypes. The common biotypes were 2 (41%), 3 (27.1%), 1 (13.2%) and 5 (10.4%). The outer membrane protein (OMP) profiles of 59 non-serotypable strains were examined by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE). A comparison of OMP profiles suggested a possible association between several strains belonging to biotype 2. Although no clear correlation was established between biotype or OMP profile cluster groups and the age or clinical state of the patients from whom the strains were isolated, SDS-PAGE analysis was a useful technique for the epidemiological study of non-serotypable H influenzae.


Assuntos
Proteínas da Membrana Bacteriana Externa/análise , Haemophilus influenzae/análise , Infecções Respiratórias/microbiologia , Fatores Etários , Eletroforese em Gel de Poliacrilamida , Humanos , Sorotipagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...