Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38276812

RESUMO

Mercury (Hg) is a toxic metal that is easily released into the atmosphere as a gas or a particulate. Since Hg has serious health impacts based on human exposure, it is a major concern where it accumulates. Southern Florida is a region of high Hg deposition in the United States. It has entered the southern Florida environment for over 56 MY. For the past 3000 to 8000 years, Hg has accumulated in the Everglades peatlands, where approximately 42.3 metric tons of Hg was deposited. The pre-industrial source of mercury that was deposited into the Everglades was from the atmosphere, consisting of combined Saharan dust and marine evasion. Drainage and the development of the Everglades for agriculture, and other mixed land uses have caused a 65.7% reduction in the quantity of peat, therefore releasing approximately 28 metric tons of Hg into the southern Florida environment over a period of approximately 133 years. Both natural and man-made fires have facilitated the Hg release. The current range in mercury release into the southern Florida environment lies between 994.9 and 1249 kg/yr. The largest source of Hg currently entering the Florida environment is from combined atmospheric sources, including Saharan dust, aerosols, sea spray, and ocean flux/evasion at 257.1-514.2 kg/yr. The remobilization of Hg from the Everglades peatlands and fires is approximately 215 kg/yr. Other large contributors include waste to energy incinerators (204.1 kg/yr), medical waste and crematory incinerators (159.7+ kg/yr), and cement plant stack discharge (150.6 kg/yr). Minor emissions include fuel emissions from motorized vehicles, gas emissions from landfills, asphalt plants, and possible others. No data are available on controlled fires in the Everglades in sugar farming, which is lumped with the overall peatland loss of Hg to the environment. Hg has impacted wildlife in southern Florida with recorded excess concentrations in fish, birds, and apex predators. This bioaccumulation of Hg in animals led to the adoption of regulations (total maximum loads) to reduce the impacts on wildlife and warnings were given to consumers to avoid the consumption of fish that are considered to be contaminated. The deposition of atmospheric Hg in southern Florida has not been studied sufficiently to ascertain where it has had the greatest impacts. Hg has been found to accumulate on willow tree leaves in a natural environment in one recent study. No significant studies of the potential impacts on human health have been conducted in southern Florida, which should be started based on the high rates of Hg fallout in rainfall and known recycling for organic sediments containing high concentrations of Hg.


Assuntos
Mercúrio , Animais , Humanos , Mercúrio/análise , Saúde Pública , Florida , Monitoramento Ambiental , Peixes , Poeira
2.
Retina ; 41(6): 1242-1250, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33079789

RESUMO

PURPOSE: To evaluate the clinical course of patients with neovascular age-related macular degeneration (nAMD) after developing endophthalmitis during their treatment with intravitreal injections. METHODS: Multicenter, retrospective series. RESULTS: From April 2013 to October 2018, 196,598 intravitreal anti-vascular endothelial growth factor (VEGF) injections were performed, with 75 cases of endophthalmitis (incidence 0.0381%). There was no association between intravitreal anti-VEGF drug (P = 0.29), anesthetic method (P = 0.26), povidone concentration (P = 0.22), or any intraprocedure variable and endophthalmitis incidence. Seventy-two patients (96%) were treated with intravitreal tap and inject , while 3 underwent immediate pars plana vitrectomy. After endophthalmitis resolution, 17 patients (22.7%) were not re-treated for nAMD (in 10 cases due to inactive disease; follow-up, 115 ± 8.4 weeks). Patients required less frequent anti-VEGF injections after infection (7.4 ± 0.61 weeks vs. 11.5 ± 1.8 weeks; P = 0.004). Preinfection logarithm of the minimum angle of resolution visual acuity was 0.585 ± 0.053 (∼20/77). It worsened with endophthalmitis (1.67 ± 0.08, ∼20/935; P < 0.001) and again on postendophthalmitis treatment day 1 (1.94 ± 0.064; count fingers; P < 0.001), but improved after reinitiating nAMD therapy (1.02 ± 0.11; ∼20/209; P < 0.001). Better visual acuity on postendophthalmitis week 1 (P = 0.002) and reinitiation of nAMD treatment (P = 0.008) were associated with better final visual acuity, and streptococcal culture with worse visual acuity (P = 0.028). The postendophthalmitis treatment interval was associated with the anti-VEGF drug used (aflibercept = ranibizumab > bevacizumab; P < 0.001). CONCLUSION: Patients with nAMD required fewer injections after endophthalmitis, suggesting a biological change in disease activity. Neovascular age-related macular degeneration became quiescent in 13.3% of eyes. Most achieved better outcomes with anti-VEGF reinitiation.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Endoftalmite/etiologia , Medição de Risco/métodos , Degeneração Macular Exsudativa/tratamento farmacológico , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/efeitos adversos , Endoftalmite/epidemiologia , Feminino , Humanos , Incidência , Injeções Intravítreas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Tomografia de Coerência Óptica/métodos , Estados Unidos/epidemiologia , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual , Degeneração Macular Exsudativa/diagnóstico
3.
Artigo em Inglês | MEDLINE | ID: mdl-33198342

RESUMO

Isopropylbenzene (cumene) is commonly encountered in groundwater at petroleum release sites due to its natural occurrence in crude oil and historical use as a fuel additive. The cumene concentrations detected at these sites often exceed regulatory guidelines or standards for states with stringent groundwater regulations. Recent laboratory analytical data collected at historical petroleum underground storage tank (UST) release sites have revealed that cumene persists at concentrations exceeding the default cleanup criterion, while other common petroleum constituents are below detection limits or low enough to allow natural attenuation as a remediation strategy. This effectively makes cumene the driver for active remediation at some sites. An insignificant amount of research has been conducted for the in-situ remediation of cumene. Sulfate Enhanced Biodegradation (SEB) is evaluated in a field case study. The results from the field case study show an approximate 92% decrease in plume area following three rounds of SEB injections. An additional objective of this research was to determine the cumene concentration in fuels currently being used to determine future impacts. A review of safety data sheets from several fuel suppliers revealed that cumene concentrations in gasoline are reported typically as wide ranges due to the proprietary formulations. Several fuels from different suppliers were analyzed to determine a baseline of cumene concentration in modern fuels. The results of the analysis indicated that cumene accounts for approximately 0.01% (diesel) to 0.13% (premium gasoline) of the overall fuel composition. Cumene generally is considered to be of low human health toxicity, with the principal concern being eye, skin, and respiratory irritation following inhalation of vapors in an occupational setting, but it has been regulated in Florida at very low concentrations based on organoleptic considerations.


Assuntos
Derivados de Benzeno , Biodegradação Ambiental , Monitoramento Ambiental , Água Subterrânea , Saúde Pública , Sulfatos , Derivados de Benzeno/análise , Derivados de Benzeno/metabolismo , Florida , Água Subterrânea/química , Humanos , Sulfatos/química , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química
4.
Artigo em Inglês | MEDLINE | ID: mdl-31117171

RESUMO

Southern Florida is underlain by rocks and sediments that naturally contain radioactive isotopes. The primary origin of the radioactive isotopes is Miocene-aged phosphate deposits that can be enriched in uranium-238 and its daughter isotopes. Nodular phosphate containing radionuclides from the Miocene has been reworked into younger formations and is ubiquitous in southern Florida. When the nodular phosphate is exposed to groundwater with geochemical conditions favorable for its dissolution, uranium, radium, and radon may be released into the groundwater system. Uranium concentrations have been measured above the 30 µg/L drinking water standard at only one location in Lee County. Radium226/228 exceedances of the drinking water standard have been documented in numerous wells in Sarasota County. Indoor radon activities have exceeded the 4 piC/L guideline in five southern Florida counties. The exceedance of radioactivity standards in drinking water does not occur in municipal drinking water supplies, but rather only in some domestic self-supply wells. Health risks for exposure to radiation from domestic self-supply wells could be mitigated by testing of well water and, if necessary, switching to the use of a different aquifer or treatment process. While the risk of exposure to radon in indoor air in southern Florida is generally low, some areas are enriched in soil radon that migrates into structures, which could be addressed by improved ventilation.


Assuntos
Radiação de Fundo , Geologia , Água Subterrânea/química , Poluentes Radioativos do Solo/análise , Urânio/análise , Poluentes Radioativos da Água/análise , Florida , Monitoramento de Radiação , Rádio (Elemento)/análise , Radônio/análise
5.
Ophthalmol Retina ; 3(1): 3-7, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30929813

RESUMO

PURPOSE: To determine the incidence of endophthalmitis after anti-vascular endothelial growth factor (VEGF) therapy at our institution and to identify potential risk factors for endophthalmitis occurring after injection. DESIGN: Retrospective, single-center cohort study. PARTICIPANTS: All patients who received an intravitreal injection of an anti-VEGF medication between January 1, 2014, and March 31, 2017. METHODS: Current Procedural Terminology and International Classification of Diseases billing codes were used to identify instances of anti-VEGF administration and cases of endophthalmitis. Medical records and injection technique were reviewed carefully in each case. Multivariable logistic regression analysis was performed in a stepwise fashion to determine independent predictors of endophthalmitis based on injection protocol. MAIN OUTCOME MEASURES: Incidence of endophthalmitis after injection and odds of endophthalmitis by injection technique with 95% confidence intervals (CIs). RESULTS: A total of 154 198 anti-VEGF injections were performed during the period of interest, resulting in 58 cases of endophthalmitis (0.038% [1:2659]). After adjustment for confounders, both 2% lidocaine jelly (odds ratio [OR], 11.28; 95% CI, 3.39-37.46; P < 0.001) and 0.5% Tetravisc (Ocusoft, Richmond, TX; OR, 3.95; 95% CI, 1.15-13.50; P = 0.03) use were independent risk factors for endophthalmitis after injection. Lid speculum use, povidone iodine strength (5% vs. 10%), injection location (superior or inferior), conjunctival displacement, use of provider gloves, use of a strict no-talking policy, use of subconjunctival lidocaine, and topical antibiotic use were not statistically significant predictors of endophthalmitis after injection. There was no difference in endophthalmitis rate among the anti-VEGF agents (bevacizumab, ranibizumab 0.3 mg, ranibizumab 0.5 mg, and aflibercept). CONCLUSIONS: The incidence of endophthalmitis after anti-VEGF injections is low. Use of lidocaine jelly or Tetravisc may increase the risk of endophthalmitis after injection.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Endoftalmite/epidemiologia , Infecções Oculares Bacterianas/epidemiologia , Injeções Intravítreas/efeitos adversos , Povidona-Iodo/administração & dosagem , Adulto , Bevacizumab/administração & dosagem , Endoftalmite/diagnóstico , Endoftalmite/microbiologia , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/microbiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Ranibizumab/administração & dosagem , Doenças Retinianas/tratamento farmacológico , Estudos Retrospectivos , Fatores de Risco , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
6.
Artigo em Inglês | MEDLINE | ID: mdl-30336588

RESUMO

Florida geologic units and soils contain a wide range in concentrations of naturally-occurring arsenic. The average range of bulk rock concentrations is 1 to 13.1 mg/kg with concentrations in accessary minerals being over 1000 mg/kg. Florida soils contain natural arsenic concentrations which can exceed 10 mg/kg in some circumstances, with organic-rich soils often having the highest concentrations. Anthropogenic sources of arsenic have added about 610,000 metric tons of arsenic into the Florida environment since 1970, thereby increasing background concentrations in soils. The anthropogenic sources of arsenic in soils include: pesticides (used in Florida beginning in the 1890's), fertilizers, chromated copper arsenate (CCA)-treated wood, soil amendments, cattle-dipping vats, chicken litter, sludges from water treatment plants, and others. The default Soil Cleanup Target Level (SCTL) in Florida for arsenic in residential soils is 2.1 mg/kg which is below some naturally-occurring background concentrations in soils and anthropogenic concentrations in agricultural soils. A review of risk considerations shows that adverse health impacts associated with exposure to arsenic is dependent on many factors and that the Florida cleanup levels are very conservative. Exposure to arsenic in soils at concentrations that exceed the Florida default cleanup level set specifically for residential environments does not necessarily pose a meaningful a priori public health risk, given important considerations such as the form of arsenic present, the route(s) of exposure, and the actual circumstances of exposure (e.g., frequency, duration, and magnitude).


Assuntos
Arsênio , Exposição Ambiental , Água Subterrânea/química , Poluentes do Solo , Solo/química , Animais , Arseniatos , Fertilizantes , Florida , Praguicidas , Risco , Esgotos , Água , Poluentes Químicos da Água , Purificação da Água , Madeira
9.
Retina ; 33(2): 387-91, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23064425

RESUMO

PURPOSE: To describe the effect of scleral buckle (SB) removal on preoperative symptoms and signs prompting removal and to assess the risk of recurrent retinal detachment (RD) after SB removal. METHODS: A retrospective study of 36 patients who underwent SB removal between August 1988 and December 2007 was performed. Indications for SB removal, presence or absence of pain or diplopia, and recurrence of RD were recorded. Composite RD rates were estimated from previously published studies and stratified into those occurring during the previtrectomy era versus later (1980 to present). RESULTS: Mean follow-up time was 75.5 months after SB removal. Thirty-two of 33 patients (97%) who had preoperative pain had symptom relief. Twelve of 12 patients who had clinical infection had resolution. Of the four patients with diplopia, two experienced complete resolution and two reported substantial improvement but required prisms to obtain single vision. Four of 34 patients (12%) whose retinas were attached at the time of SB removal developed recurrent RD but were successfully repaired without significant visual loss from the RD. CONCLUSION: Scleral buckle removal is effective in eliminating SB-related pain and infection. Symptomatic diplopia can sometimes improve after SB removal. The rates of RD after SB removal observed in this study (12%) and in others performed in the era of vitrectomy were notably lower than those of previous reports.


Assuntos
Remoção de Dispositivo , Diplopia/terapia , Infecções Oculares/terapia , Dor Ocular/terapia , Descolamento Retiniano/cirurgia , Recurvamento da Esclera/efeitos adversos , Vitrectomia , Diplopia/etiologia , Infecções Oculares/etiologia , Dor Ocular/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Descolamento Retiniano/etiologia , Estudos Retrospectivos , Fatores de Tempo
10.
Arch Ophthalmol ; 130(2): 186-9, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22332210

RESUMO

OBJECTIVE: To compare 20-gauge standard pars plana vitrectomy (PPV) with transconjunctival cannulated PPV in the development of intraoperative retinal breaks and postoperative rhegmatogenous retinal detachments (RRDs) in a large series of patients undergoing PPV for macular pucker or macular hole. METHODS: This study was conducted at an academic tertiary care vitreoretinal practice in Milwaukee, Wisconsin. Patients undergoing 3-port PPV with standard 20-gauge instrumentation were compared with patients undergoing 3-port PPV with transconjunctival cannulated systems, including 20 gauge, 23 gauge, and 25 gauge, from January 1, 2003, through December 31, 2009. The main outcome measures were rates of intraoperative retinal breaks and postoperative RRD. RESULTS: Four hundred twenty-six unique eyes met inclusion criteria. Fifty-four of 426 eyes (12.7%) were diagnosed as having new retinal tears intraoperatively as follows: 47 of 204 patients (23.0%) undergoing the standard 20-gauge procedure developed intraoperative retinal tears compared with 7 of 211 patients (3.3%) undergoing the transconjunctival cannulated procedure (risk ratio [RR], 0.12; 95% CI, 0.05-0.26; P < .001). Patients experiencing intraoperative retinal tears were not at increased risk of developing postoperative RRD (RR, 1.4; 95% CI, 0.39-5.0; P = .61). Although a trend was present, transconjunctival cannulated vitrectomy was not significantly protective against the development of postoperative RRD (RR, 0.60; 95% CI, 0.17-1.3; P = .14). CONCLUSION: Transconjunctival cannulated PPV, including 20-gauge, 23-gauge, and 25-gauge systems, is associated with significantly reduced rates of intraoperative retinal tear formation compared with standard 20-gauge PPV.


Assuntos
Complicações Intraoperatórias , Complicações Pós-Operatórias , Descolamento Retiniano/etiologia , Perfurações Retinianas/etiologia , Vitrectomia/efeitos adversos , Cateterismo/métodos , Túnica Conjuntiva/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Microcirurgia/métodos , Doenças Retinianas/cirurgia , Fatores de Risco , Acuidade Visual/fisiologia , Vitrectomia/métodos
11.
Br J Ophthalmol ; 96(5): 723-9, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22328813

RESUMO

PURPOSE: To evaluate the utility of ring ratios in detecting hydroxychloroquine (HCQ) related retinal toxicity using the 103-hexagon multifocal electroretinogram (mfERG). DESIGN: Retrospective cross-sectional study. METHODS: 23 patients taking HCQ were consecutively evaluated for retinal toxicity and divided into those without (HCQ-non-toxic group) and with documented visual field loss (HCQ-toxic group). A control patient group without retinal disease and not on HCQ was used for comparison. 103-hexagon P(1) mfERG amplitude response densities were analysed by averaging the 103 responses into six (age-corrected) concentric rings (R(1)-R(6)), calculating standard ring ratios (R(1):R(2)-R(1):R(6)) and R(5) ring ratios (R(5):R(1)-R(5):R(6)). Receiver operating characteristic curves were used to compare these tests for detecting toxicity. RESULTS: Relative to HCQ-non-toxic and control groups, the HCQ-toxic group showed generalised reduction of the 103-hexagon mfERG absolute responses most prominent in the foveal/pericentral regions. R(5) ring ratios were superior to standard ring ratios in discriminating the HCQ-toxic from the HCQ-non-toxic and control groups and were approximately equivalent to pericentral absolute ring responses in detecting HCQ retinal toxicity by receiver operating characteristic criteria, with R(5):R(4) and R(5):R(3) ratios performing best. However, R(5) ring ratios revealed improved sensitivity over absolute ring responses (89% vs 73%) at a 95% specificity threshold. CONCLUSIONS: Ring ratio analysis using the R(5) ring response as the 'internal reference ring' appeared equivalent to pericentral absolute ring responses in detecting HCQ retinal toxicity, and possibly superior at clinically desirable specificity thresholds. R(5) ring ratios did not require age correction, a potential clinical advantage over absolute ring responses.


Assuntos
Antirreumáticos/efeitos adversos , Eletrorretinografia/efeitos dos fármacos , Hidroxicloroquina/efeitos adversos , Retina/patologia , Doenças Retinianas/diagnóstico , Adolescente , Adulto , Idoso , Área Sob a Curva , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Retina/efeitos dos fármacos , Doenças Retinianas/induzido quimicamente , Estudos Retrospectivos , Campos Visuais
13.
Invest Ophthalmol Vis Sci ; 51(8): 3909-12, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20335608

RESUMO

PURPOSE: To investigate whether the use of the best of multiple measures of visual acuity as an endpoint introduces bias into study results. METHODS: Mathematical models and Monte Carlo simulations were used. A model was designed in which a hypothetical intervention did not influence the visual acuity. The best of one or more postintervention measures was used as the outcome variable and was compared to the baseline measure. Random test-retest variability was included in the model. RESULTS: When the better of two postintervention measures was used as the outcome variable with a sample size of 25, the model falsely rejected the null hypothesis 55% of the time. When the best of three measures was used, the false-positive rate increased to 90%. The probability of falsely rejecting the null hypothesis increased with increasing sample size, also increasing the number of measures used to select the outcome variable. CONCLUSIONS: Using the best of multiple measures as an outcome variable introduces a systematic bias resulting in false conclusions of improvement in that variable. The use of best of multiple measures of visual acuity as an outcome variable should be avoided.


Assuntos
Viés , Determinação de Ponto Final , Acuidade Visual/fisiologia , Humanos , Modelos Teóricos , Método de Monte Carlo , Avaliação de Resultados em Cuidados de Saúde , Probabilidade
14.
Cornea ; 29(1): 13-8, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19907297

RESUMO

PURPOSE: To measure corneal sensation after Descemet stripping and automated endothelial keratoplasty (DSAEK). METHODS: Prospective comparative case series involving 52 eyes of 29 patients in the early postoperative period (<6 months) after small-incision DSAEK. Patients' contralateral eye served as a control. The sample size calculation was calculated assuming an alpha error of 0.05 and a beta error of 0.2. This determined that a sample size of 11 patients would be sufficient to detect a difference in corneal sensation of 5 mm as measured with the Cochet-Bonnet esthesiometer. The nylon filament was used to measure threshold sensation at 9 points on the operative eye and 5 points on the control. The data were analyzed using the paired samples test. RESULTS: Although the results demonstrated mild hypesthesia of the corneal epithelium overlying the donor lenticule, we found no statistically significant difference in corneal sensation at the central point when comparing the DSAEK cornea with the control (57 vs 59 mm, P = 0.13.) In addition, when comparing corresponding points on the epithelium overlying the DSAEK graft and host cornea, no significant difference was found (57 vs 58 mm, P = 0.32). A difference was detected when comparing the average corneal sensation of the DSAEK eye with the control, but careful analysis of the data shows that this was driven by the slight decrease in sensitivity at the temporal incisional point (57 vs 59 mm, P = 0.002). CONCLUSIONS: The results of this prospective study demonstrate the relative preservation of corneal sensitivity after DSAEK. Preservation of corneal sensation may provide another advantage of DSAEK over traditional penetrating keratoplasty.


Assuntos
Córnea/fisiologia , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs/cirurgia , Sensação/fisiologia , Idoso , Idoso de 80 Anos ou mais , Técnicas de Diagnóstico Oftalmológico , Feminino , Distrofia Endotelial de Fuchs/fisiopatologia , Humanos , Hipestesia/prevenção & controle , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Prospectivos
15.
Ophthalmology ; 117(1): 49-54, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19815281

RESUMO

PURPOSE: To determine if the 1-month postoperative error of predicted refraction of the first eye can be used to alter intraocular lens (IOL) power selection and improve refractive results for the second eye in patients undergoing bilateral, sequential phacoemulsification with IOL implantation (phaco/IOL). DESIGN: Retrospective, consecutive, case series. PARTICIPANTS: Three hundred consecutive patients who underwent uncomplicated bilateral, sequential phaco/IOL between January 1, 2006, and December 31, 2007, by a single surgeon using a single IOL platform. METHODS: The observed second eye 1-month postoperative spherical equivalent refractive error was compared with calculations of the hypothetic 1-month postoperative spherical equivalent refractive error if the first eye error had been fully or partially incorporated into the choice of IOL power for the second eye. The optimal amount of partial adjustment was determined. MAIN OUTCOME MEASURES: The error of predicted refraction: the difference between the actual or hypothetic spherical equivalent refractive errors and those predicted by preoperative calculations. RESULTS: A total of 206 patients met inclusion criteria. The average of the absolute value of the unadjusted second eye error (|E(UNADJ)|) was +0.44 diopters (D) compared with +0.42 D for the fully adjusted second eye error (|E(FULL)|). The optimal amount of adjustment of the second eye IOL power was determined to be 50%; the average of the absolute value of this partially adjusted second eye error (|E(PARTIAL,50%)|) was +0.36 D; this was statistically different from |E(UNADJ)| (P<0.0001) and |E(FULL)| (P = 0.001). The statistically significant benefit was observed for patients with either myopic or hyperopic errors in the first eye. The percentages of patients achieving postoperative refractions within 0.5 D and 1.0 D of the predicted refraction were 66.5% and 90.3%, respectively, for the unadjusted second eye, 67.0% and 90.8%, respectively, for the hypothetic fully adjusted second eye, and 74.3% and 93.7%, respectively, for the hypothetic partially adjusted (50%) second eye. CONCLUSIONS: Accounting for 50% of the observed error of predicted refraction of the first eye reduced the error of predicted refraction in the second eye. This novel methodology has the potential to improve the refractive outcomes in the second eye of patients with cataract. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Refração Ocular/fisiologia , Erros de Refração/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Cuidados Pré-Operatórios , Erros de Refração/diagnóstico , Estudos Retrospectivos , Adulto Jovem
16.
Ophthalmic Surg Lasers Imaging ; 40(6): 554-60, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19928720

RESUMO

BACKGROUND AND OBJECTIVE: To quantify the interpretation of fluorescein angiograms of evolving predominantly classic choroidal neovascularization in age-related macular degeneration. PATIENTS AND METHODS: Thirty-six fluorescein angiograms of predominantly classic choroidal neovascularization were used to define 22 fluorescein angiogram pairs. Imaging software was used to measure surface area and greatest linear dimension (GLD). Six retina physicians estimated the change in surface area and GLD for each pair before and after demarcation of the lesions' borders and GLD. RESULTS: For enlarging lesions, the smallest changes consistently detected by physicians were a 5% to 15% increase in surface area and a 5% to 15% increase in GLD; for shrinking lesions, they were a 5% to 15% decrease in surface area and a 5% to 15% decrease in GLD. Linear regression demonstrated moderate correlation between physician and software estimates of surface area and GLD change (r(2) = 0.50 and 0.67, respectively; P < .001), which was higher with lesion demarcation (r(2) = 0.91 and 0.93, respectively; P < .001). CONCLUSION: Computer-assisted demarcation of lesion surface area and GLD reduced variability in physicians' estimates of choroidal neovascularization size change and improved correlation with software measurements.


Assuntos
Neovascularização de Coroide/diagnóstico , Competência Clínica , Angiofluoresceinografia/métodos , Degeneração Macular/diagnóstico , Neovascularização de Coroide/etiologia , Fundo de Olho , Humanos , Processamento de Imagem Assistida por Computador/métodos , Degeneração Macular/complicações , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Cornea ; 28(5): 597-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19421030

RESUMO

PURPOSE: To report the diagnosis and management of a patient with a well-tolerated, long-standing retained intracorneal foreign body. METHODS: We describe the case of a 62-year-old man with a 40-year-old retained wood foreign body within the posterior stroma of the cornea. To the authors' knowledge, this is the longest standing intracorneal foreign body reported in the literature. RESULTS: The foreign body was asymptomatic, well tolerated, and appeared encapsulated, so the patient was carefully observed. One year later, the examination remained stable. CONCLUSIONS: Our case seems to violate the classic teaching that some inorganic intracorneal foreign bodies are well tolerated, whereas organic foreign bodies are poorly tolerated. It is possible that foreign organic material--if early infection is avoided--can be well tolerated by the eye.


Assuntos
Substância Própria/lesões , Corpos Estranhos no Olho/fisiopatologia , Madeira , Corpos Estranhos no Olho/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
18.
Cornea ; 28(4): 471-3, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19411972

RESUMO

PURPOSE: To report the donor-to-host transmission of Candida albicans after Descemet stripping and automated endothelial keratoplasty (DSAEK). METHODS: An 80-year-old woman with pseudophakic bullous keratopathy developed an infiltrate in the donor corneal lenticule after DSAEK. RESULTS: Donor corneoscleral rim cultures grew C. albicans. Gram stain of the removed corneal lenticule demonstrated budding yeast and pseudohyphae, and cultures yielded C. albicans. Despite topical and systemic antifungal therapy and therapeutic penetrating keratoplasty, the patient developed a blind painful eye and underwent enucleation. CONCLUSIONS: This case report indicates that fungal keratitis may occur from donor-to-host transmission after DSAEK. The location of the infected tissue poses diagnostic and therapeutic challenges for the surgeon.


Assuntos
Candidíase/transmissão , Córnea/microbiologia , Transplante de Córnea/efeitos adversos , Transmissão de Doença Infecciosa , Endotélio Corneano/transplante , Infecções Oculares Fúngicas/transmissão , Ceratite/microbiologia , Idoso de 80 Anos ou mais , Candida albicans/isolamento & purificação , Candidíase/microbiologia , Candidíase/cirurgia , Lâmina Limitante Posterior/cirurgia , Infecções Oculares Fúngicas/microbiologia , Infecções Oculares Fúngicas/cirurgia , Feminino , Humanos , Ceratite/cirurgia , Ceratoplastia Penetrante , Doadores de Tecidos
19.
Ophthalmic Surg Lasers Imaging ; 40(2): 201-2, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19320315

RESUMO

Scleral buckle removal is an uncommon procedure performed for various reasons. Microbiological information on explanted scleral buckles remains limited. The authors identified 37 cases of scleral buckle removal during an 18-year period. Bacterial cultures isolated an organism in 4 of 9 patients (44%) with clinical infection. Organisms identified included methicillin-resistant Staphylococcus aureus, Pseudomonas aeruginosa, Mycobacterium abscessus, and coagulase-negative Staphylococcus species. Bacterial cultures isolated an organism in 3 of 11 patients (27%) without clinical infection. Organisms identified included Nocardia species, Alcaligenes xylosoxidans, and Mycobacterium chelonae. Scleral buckles appearing clinically infected may be associated with more virulent organisms and a greater chance of identifying an organism. Bacterial cultures may be of value for scleral buckles upon removal.


Assuntos
Bactérias/isolamento & purificação , Infecções Oculares Bacterianas/microbiologia , Próteses e Implantes , Recurvamento da Esclera/efeitos adversos , Remoção de Dispositivo , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Am J Ophthalmol ; 146(6): 930-4.e1, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18775528

RESUMO

PURPOSE: To assess short-term trends and the need to monitor intraocular pressure (IOP) changes immediately after intravitreal injections of ranibizumab, bevacizumab, pegaptanib, and triamcinolone acetonide. DESIGN: Retrospective, interventional case series. METHODS: Charts of 213 consecutive injections to 120 eyes of 112 patients were reviewed. Pressures were measured before injection, immediately after injection (T0), and at five-minute intervals until IOP was less than 30 mm Hg. Optic nerve perfusion was assessed by testing for hand movement vision and by indirect ophthalmoscopic examination. Kaplan-Meier and Chi-square analyses of IOP after injections and correlation of IOP spikes to drug, needle bore size, injection volume, and history of glaucoma were performed. RESULTS: Mean preinjection IOP was 14 mm Hg (range, 7 to 22 mm Hg). Mean IOP at T0 was 44 mm Hg (range, 4 to 87 mm Hg). All but one eye had at least hand movement vision and a perfused optic nerve at T0. IOP was reduced to less than 30 mm Hg in 96% of injections by 15 minutes and in 100% by 30 minutes. Eyes with a history of glaucoma took longer to normalize the IOP (P = .002). Statistically significant IOP spikes were observed with a smaller needle bore size (P < .0001) and in eyes with a history of glaucoma (P = .001). CONCLUSIONS: Elevations in IOP immediately after intravitreal injections are common, but are transient. Prolonged monitoring of IOP may not be necessary on the day of injection in most cases if hand movement vision, optic nerve perfusion, and lack of intraocular complications have been verified. However, cautious monitoring should be considered in select cases.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Pressão Intraocular/efeitos dos fármacos , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais Humanizados , Aptâmeros de Nucleotídeos/administração & dosagem , Bevacizumab , Monitoramento de Medicamentos , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Ranibizumab , Doenças Retinianas/tratamento farmacológico , Estudos Retrospectivos , Fatores de Tempo , Tonometria Ocular , Triancinolona Acetonida/administração & dosagem , Corpo Vítreo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...